Elke Vanlaere
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Elke Vanlaere has a total of 113 co-authors. Here are the top co-authors by number of shared publications:
- Marijke Reynders
Department of Medical Microbiology, AZ Sint-Jan Brugge AV , Brugge
2 shared publications - Aline Huwart
Clinique André Renard, 4040 Herstal, Belgium
1 shared publication - Amelie Heinrichs
Laboratory of Clinical Biology, Hospital Arlon—Vivalia, 6700 Arlon, Belgium
1 shared publication An Boel
Clinical Laboratory of Microbiology, OLVZ Aalst, Moorselbaan 164, 9300 Aalst, Belgium
1 shared publication- Ann Lemmens
Laboratory of Clinical Biology, AZ Sint-Maarten Hospital, 2800 Mechelen, Belgium
1 shared publication - Annaelle Collin
Vivalia, Site Marche-en-Famenne, 6900 Marche, Belgium
1 shared publication
Latest Publications
- Open Access
Nationwide Harmonization Effort for Semi-Quantitative Reporting of SARS-CoV-2 PCR Test Results in Belgium
From early 2020, a high demand for SARS-CoV-2 tests was driven by several testing indications, including asymptomatic cases, resulting in the massive roll-out of PCR assays to combat the pandemic. Considering the dynamic of viral shedding during the course of infection, the demand to report cycle threshold (Ct) values rapidly emerged. As Ct values can be affected by a number of factors, we considered that harmonization of semi-quantitative PCR results across laboratories would avoid potential divergent interpretations, particularly in the absence of clinical or serological information. A proposal to harmonize reporting of test results was drafted by the National Reference Centre (NRC) UZ/KU Leuven, distinguishing four categories of positivity based on RNA copies/mL. Pre-quantified control material was shipped to 124 laboratories with instructions to setup a standard curve to define thresholds per assay. For each assay, the mean Ct value and corresponding standard deviation was calculated per target gene, for the three concentrations (107, 105 and 103 copies/mL) that determine the classification. The results of 17 assays are summarized. This harmonization effort allowed to ensure that all Belgian laboratories would report positive PCR results in the same semi-quantitative manner to clinicians and to the national database which feeds contact tracing interventions.
Open AccessNationwide Harmonization Effort for Semi-Quantitative Reporting of SARS-CoV-2 PCR Test Results in Belgium
From early 2020, a high demand for SARS-CoV-2 tests was driven by several testing indications, including asymptomatic cases, resulting in the massive roll-out of PCR assays to combat the pandemic. Considering the dynamic of viral shedding during the course of infection, the demand to report cycle threshold (Ct) values rapidly emerged. As Ct values can be affected by a number of factors, we considered that harmonization of semi-quantitative PCR results across laboratories would avoid potential divergent interpretations, particularly in the absence of clinical or serological information. A proposal to harmonize reporting of test results was drafted by the National Reference Centre (NRC) UZ/KU Leuven, distinguishing four categories of positivity based on RNA copies/mL. Pre-quantified control material was shipped to 124 laboratories with instructions to setup a standard curve to define thresholds per assay. For each assay, the mean Ct value and corresponding standard deviation was calculated per target gene, for the three concentrations (107, 105 and 103 copies/mL) that determine the classification. The results of 17 assays are summarized. This harmonization effort allowed to ensure that all Belgian laboratories would report positive PCR results in the same semi-quantitative manner to clinicians and to the national database which feeds contact tracing interventions.
- Open Access
- 19 October 2021
- Published by Microbiology Society in Journal of Medical Microbiology
- Vol. 70 (10) , 001438
Multicenter evaluation of the FilmArray Meningitis/Encephalitis assay in a routine setting
Introduction.The FilmArray Meningitis/Encephalitis (FA-ME) Panel (Biofire, Salt Lake City, Utah, US) enables fast and automated detection of 14 pathogens in cerebrospinal fluid (CSF).Gap statement.The performance of the FA-ME panel in a real routine setting has not yet been described and could lead to better patient management in cases of good performance.Aim.This multicenter study verified the FA-ME panel analytical performance in a routine hospital setting.Methodology.Between April 2016 and April 2018, 454 CSF samples were analysed with the FA-ME panel and compared with routine diagnostics. In cases of discrepancy or lack of a comparator result, a profound analysis based on patient records and other laboratory results was performed.Results.A first analysis of 65 frozen samples, suspicious for meningitis had a 89 % concordance with routine diagnostics. The limit of detection (LOD) was confirmed for all pathogens except forStreptococcus agalactiaeand a strain ofHaemophilus influenzae (Escherichia coli K1andCryptococcus gattiiLOD experiments were not performed). The routine evaluation showed a positive result in 114 (25 %) clinical samples for at least one target. In three samples co-infections were found. After discrepancy analysis, overall sensitivity was 98 % (false negative FA-ME results for one HSV2, two HSV1 and two parechovirus). Four FA-ME results were considered false positive (two HHV6, one VZV and oneE. coli K1), resulting in an overall specificity of >99 %. A clinical added value of the assay was seen in the diagnosis of eight cases of bacterial meningitis.Conclusion.Because of its rapidity and ease of use, the FA-ME panel has great potential in the diagnosis of central nervous infections. Implementation can improve clinical management, but costs and analytical limitations need to be addressed to convince clinicians and laboratories of its value.
- 19 October 2021
- Published by Microbiology Society in Journal of Medical Microbiology
- Vol. 70 (10) , 001438
Open AccessMulticenter evaluation of the FilmArray Meningitis/Encephalitis assay in a routine setting
Introduction.The FilmArray Meningitis/Encephalitis (FA-ME) Panel (Biofire, Salt Lake City, Utah, US) enables fast and automated detection of 14 pathogens in cerebrospinal fluid (CSF).Gap statement.The performance of the FA-ME panel in a real routine setting has not yet been described and could lead to better patient management in cases of good performance.Aim.This multicenter study verified the FA-ME panel analytical performance in a routine hospital setting.Methodology.Between April 2016 and April 2018, 454 CSF samples were analysed with the FA-ME panel and compared with routine diagnostics. In cases of discrepancy or lack of a comparator result, a profound analysis based on patient records and other laboratory results was performed.Results.A first analysis of 65 frozen samples, suspicious for meningitis had a 89 % concordance with routine diagnostics. The limit of detection (LOD) was confirmed for all pathogens except forStreptococcus agalactiaeand a strain ofHaemophilus influenzae (Escherichia coli K1andCryptococcus gattiiLOD experiments were not performed). The routine evaluation showed a positive result in 114 (25 %) clinical samples for at least one target. In three samples co-infections were found. After discrepancy analysis, overall sensitivity was 98 % (false negative FA-ME results for one HSV2, two HSV1 and two parechovirus). Four FA-ME results were considered false positive (two HHV6, one VZV and oneE. coli K1), resulting in an overall specificity of >99 %. A clinical added value of the assay was seen in the diagnosis of eight cases of bacterial meningitis.Conclusion.Because of its rapidity and ease of use, the FA-ME panel has great potential in the diagnosis of central nervous infections. Implementation can improve clinical management, but costs and analytical limitations need to be addressed to convince clinicians and laboratories of its value.
- 1 September 2015
- Published by Elsevier in Diagnostic Microbiology and Infectious Disease
- Vol. 83 (1) , 37-40
Multicenter evaluation of BD Veritor System and RSV K-SeT for rapid detection of respiratory syncytial virus in a diagnostic laboratory setting
- 1 September 2015
- Published by Elsevier in Diagnostic Microbiology and Infectious Disease
- Vol. 83 (1) , 37-40
Multicenter evaluation of BD Veritor System and RSV K-SeT for rapid detection of respiratory syncytial virus in a diagnostic laboratory setting