Burkhard Dumler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Burkhard Dumler has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Bjoern Michael Eskofier
Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU)
2 shared publications Andreas Kraft
1 shared publication- Arne Küderle
Machine Learning and Data Analytics Lab (MaD Lab), Department Artificial Intelligence in Biomedical Engineering (AIBE), Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91052 Erlangen, Germany
1 shared publication - Bernhard Nebel
University of Freiburg
1 shared publication Boris Szerbakowski
Sick AG
1 shared publicationChiara Herbener
1 shared publication
Latest Publications
- Open Access
- 30 June 2025
- Published by Frontiers Media SA in Frontiers in Sports and Active Living
- Vol. 7, 1627820
Performance tracking in female youth soccer through wearables and subjective assessments
This study investigates performance development and the relationship between subjective and objective training assessments in female youth soccer using wearable sensor technology. The aim of this study was to assess how subjective post-training ratings (intensity and happiness) relate to high-percentile performance outputs, and to identify longitudinal trends in female youth soccer players using IMU-based wearable data. Data were collected over a 14-month period from 46 players (U17 and U20 teams) equipped with foot-mounted inertial measurement units (IMUs) during regular training sessions. Objective performance metrics, including 95th percentile of ball speed, peak speed, and absolute distance, were derived using a multi-stage machine learning pipeline, while subjective metrics (intensity and happiness) were collected via post-session Likert-scale questionnaires using an app. Using the modified Mann-Kendall test, we found 30 significant longitudinal trends, with 14 positive and 16 negative trends across key performance metrics. Peak speed showed the highest number of trends (13), followed by absolute distance (10) and ball speed (7). Correlation analyses based on the Spearman coefficient (with False Discovery Rate correction) revealed meaningful associations between subjective self-assessments and high-percentile performance metrics, with notable differences across player positions and age groups. A robustness check confirmed these patterns also hold when analyzing the 99th percentile of performance outputs. Our findings underscore the value of combining wearable sensor data with subjective evaluations for individualized, role-specific performance monitoring and training optimization in youth soccer. However, as an exploratory study with a single cohort, findings require further validation in broader populations.
- 30 June 2025
- Published by Frontiers Media SA in Frontiers in Sports and Active Living
- Vol. 7, 1627820
Open AccessPerformance tracking in female youth soccer through wearables and subjective assessments
This study investigates performance development and the relationship between subjective and objective training assessments in female youth soccer using wearable sensor technology. The aim of this study was to assess how subjective post-training ratings (intensity and happiness) relate to high-percentile performance outputs, and to identify longitudinal trends in female youth soccer players using IMU-based wearable data. Data were collected over a 14-month period from 46 players (U17 and U20 teams) equipped with foot-mounted inertial measurement units (IMUs) during regular training sessions. Objective performance metrics, including 95th percentile of ball speed, peak speed, and absolute distance, were derived using a multi-stage machine learning pipeline, while subjective metrics (intensity and happiness) were collected via post-session Likert-scale questionnaires using an app. Using the modified Mann-Kendall test, we found 30 significant longitudinal trends, with 14 positive and 16 negative trends across key performance metrics. Peak speed showed the highest number of trends (13), followed by absolute distance (10) and ball speed (7). Correlation analyses based on the Spearman coefficient (with False Discovery Rate correction) revealed meaningful associations between subjective self-assessments and high-percentile performance metrics, with notable differences across player positions and age groups. A robustness check confirmed these patterns also hold when analyzing the 99th percentile of performance outputs. Our findings underscore the value of combining wearable sensor data with subjective evaluations for individualized, role-specific performance monitoring and training optimization in youth soccer. However, as an exploratory study with a single cohort, findings require further validation in broader populations.
- Open Access
Does the Position of Foot-Mounted IMU Sensors Influence the Accuracy of Spatio-Temporal Parameters in Endurance Running?
Wearable sensor technology already has a great impact on the endurance running community. Smartwatches and heart rate monitors are heavily used to evaluate runners’ performance and monitor their training progress. Additionally, foot-mounted inertial measurement units (IMUs) have drawn the attention of sport scientists due to the possibility to monitor biomechanically relevant spatio-temporal parameters outside the lab in real-world environments. Researchers developed and investigated algorithms to extract various features using IMU data of different sensor positions on the foot. In this work, we evaluate whether the sensor position of IMUs mounted to running shoes has an impact on the accuracy of different spatio-temporal parameters. We compare both the raw data of the IMUs at different sensor positions as well as the accuracy of six endurance running-related parameters. We contribute a study with 29 subjects wearing running shoes equipped with four IMUs on both the left and the right shoes and a motion capture system as ground truth. The results show that the IMUs measure different raw data depending on their position on the foot and that the accuracy of the spatio-temporal parameters depends on the sensor position. We recommend to integrate IMU sensors in a cavity in the sole of a running shoe under the foot’s arch, because the raw data of this sensor position is best suitable for the reconstruction of the foot trajectory during a stride.
Open AccessDoes the Position of Foot-Mounted IMU Sensors Influence the Accuracy of Spatio-Temporal Parameters in Endurance Running?
Wearable sensor technology already has a great impact on the endurance running community. Smartwatches and heart rate monitors are heavily used to evaluate runners’ performance and monitor their training progress. Additionally, foot-mounted inertial measurement units (IMUs) have drawn the attention of sport scientists due to the possibility to monitor biomechanically relevant spatio-temporal parameters outside the lab in real-world environments. Researchers developed and investigated algorithms to extract various features using IMU data of different sensor positions on the foot. In this work, we evaluate whether the sensor position of IMUs mounted to running shoes has an impact on the accuracy of different spatio-temporal parameters. We compare both the raw data of the IMUs at different sensor positions as well as the accuracy of six endurance running-related parameters. We contribute a study with 29 subjects wearing running shoes equipped with four IMUs on both the left and the right shoes and a motion capture system as ground truth. The results show that the IMUs measure different raw data depending on their position on the foot and that the accuracy of the spatio-temporal parameters depends on the sensor position. We recommend to integrate IMU sensors in a cavity in the sole of a running shoe under the foot’s arch, because the raw data of this sensor position is best suitable for the reconstruction of the foot trajectory during a stride.
- 8 October 2018
- Published by Walter de Gruyter GmbH
- p. 140-147
Das Design digitaler Kleidung
- 1 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Sleeve based knee angle calculation for rehabilitation
The knee flexion-extension angle is an important criterion for the rehabilitation process after a rupture of the anterior cruciate ligament (ACL), which is a typical sports injury. This paper describes the development and evaluation of a smart knee sleeve, which is capable of calculating the knee flexion-extension angle based on inertial sensors. The output is to be used to supervise and speed up rehabilitation by guiding patients through exercises and giving feedback about the execution. The accuracy of the knee angle calculation was evaluated in a study with twelve healthy subjects performing six different exercises with an optical system as reference. The effects of different functional alignment movements, knee sleeve material and recalibration on the final knee angle were evaluated. The mean absolute error (MAE) of all maxima and minima was calculated and averaged over all subjects and exercises. An MAE of 5.2° compared to the gold standard was achieved while the Pearson correlation was 0.96 for 30 minutes training without recalibration or restart of the system.
- 1 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Sleeve based knee angle calculation for rehabilitation
The knee flexion-extension angle is an important criterion for the rehabilitation process after a rupture of the anterior cruciate ligament (ACL), which is a typical sports injury. This paper describes the development and evaluation of a smart knee sleeve, which is capable of calculating the knee flexion-extension angle based on inertial sensors. The output is to be used to supervise and speed up rehabilitation by guiding patients through exercises and giving feedback about the execution. The accuracy of the knee angle calculation was evaluated in a study with twelve healthy subjects performing six different exercises with an optical system as reference. The effects of different functional alignment movements, knee sleeve material and recalibration on the final knee angle were evaluated. The mean absolute error (MAE) of all maxima and minima was calculated and averaged over all subjects and exercises. An MAE of 5.2° compared to the gold standard was achieved while the Pearson correlation was 0.96 for 30 minutes training without recalibration or restart of the system.