Anna Miyayasu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Anna Miyayasu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Manabu Kanazawa
Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Tokyo 113-8549, Japan
3 shared publications - Shunsuke Minakuchi
Gerodontology and Oral Rehabilitation, Institute of Science Tokyo, Tokyo 113-8510, Japan
3 shared publications - Sahaprom Namano
Gerodontology and Oral Rehabilitation, Institute of Science Tokyo, Tokyo 113-8510, Japan
2 shared publications - Yuriko Komagamine
Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Tokyo 113-8549, Japan
2 shared publications - Ayami Jo
Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo, Japan
1 shared publication - Bui Ngoc Huyen Trang
Gerodontology and Oral Rehabilitation, Institute of Science Tokyo, Tokyo 113-8510, Japan
1 shared publication
Latest Publications
- Open Access
- 19 April 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (8) , 3958
Cost-Effectiveness of Immediately and Conventionally Loaded Two-Implant Mandibular Overdentures: A 24-Month Exploratory Pilot Study
Background: The cost-effectiveness of immediate versus conventional loading of two-implant overdentures (2-IODs) remains unclear. This exploratory randomized clinical trial compared the economic and clinical outcomes of these protocols over 24 months. Methods: Seventeen edentulous patients were randomly assigned to conventional (CL, n = 7) or immediate loading (IL, n = 10). Outcomes included longitudinal changes (Δ) in Oral Health-Related Quality of Life (OHIP-EDENT-J), Patient Denture Assessment (PDA), and satisfaction. Costs were analyzed from a healthcare provider perspective. Between-group comparisons of Δ scores were performed using Mann–Whitney U tests to adjust for baseline imbalances. Results: Both protocols showed trends toward clinical improvement. However, between-group analysis of longitudinal change scores (Δ) revealed no statistically significant differences (p > 0.05). The immediate loading protocol incurred 44.7% higher direct costs without demonstrating statistically superior patient-reported benefits. Individual-level analysis via a cost-effectiveness plane showed high variability and significant overlap between groups. Conclusions: Within the limitations of this exploratory pilot study, no statistically significant differences in clinical outcomes were found between loading protocols. Descriptively, conventionally loaded 2-IODs were associated with lower resource intensity and a more stable clinical trajectory in this cohort. These preliminary findings suggest that immediate loading may not offer a clear economic advantage, though larger multicenter trials are required for a definitive assessment.
- 19 April 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (8) , 3958
Open AccessCost-Effectiveness of Immediately and Conventionally Loaded Two-Implant Mandibular Overdentures: A 24-Month Exploratory Pilot Study
Background: The cost-effectiveness of immediate versus conventional loading of two-implant overdentures (2-IODs) remains unclear. This exploratory randomized clinical trial compared the economic and clinical outcomes of these protocols over 24 months. Methods: Seventeen edentulous patients were randomly assigned to conventional (CL, n = 7) or immediate loading (IL, n = 10). Outcomes included longitudinal changes (Δ) in Oral Health-Related Quality of Life (OHIP-EDENT-J), Patient Denture Assessment (PDA), and satisfaction. Costs were analyzed from a healthcare provider perspective. Between-group comparisons of Δ scores were performed using Mann–Whitney U tests to adjust for baseline imbalances. Results: Both protocols showed trends toward clinical improvement. However, between-group analysis of longitudinal change scores (Δ) revealed no statistically significant differences (p > 0.05). The immediate loading protocol incurred 44.7% higher direct costs without demonstrating statistically superior patient-reported benefits. Individual-level analysis via a cost-effectiveness plane showed high variability and significant overlap between groups. Conclusions: Within the limitations of this exploratory pilot study, no statistically significant differences in clinical outcomes were found between loading protocols. Descriptively, conventionally loaded 2-IODs were associated with lower resource intensity and a more stable clinical trajectory in this cohort. These preliminary findings suggest that immediate loading may not offer a clear economic advantage, though larger multicenter trials are required for a definitive assessment.
- Open Access
- 25 October 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (21) , 11687
Immediate Versus Conventional Loading of Two-Implant Overdenture with Magnetic Attachments: A 5-Year Follow-Up on Patient-Reported Outcomes
Comprehensive, long-term studies on patient-reported outcomes for two-implant overdentures with magnetic attachments using immediate or conventional loading methods are lacking. This study aimed to provide 5-year follow-up data comparing patient-reported outcomes for mandibular overdentures supported by two implants with magnetic attachments under immediate or conventional loading. Nineteen edentulous mandible patients were randomly assigned to immediate (IG) or conventional loading groups (CG). Two implants were placed with prostheses, loaded on the same day (immediate) or three months later (conventional). Participants completed questionnaires (oral health-related quality of life (OHRQoL), patient general satisfaction, and patient’s denture assessment (PDA)) at baseline and yearly intervals for 5 years. Results showed no significant differences between IG and CG throughout the study. However, the within-group analysis revealed significant improvements in OHRQoL, patient satisfaction, and all PDA domains from the baseline to years 1–5. Regarding patient satisfaction, significant differences were observed between T1, T2, and T3 when compared with T0 of IG and T1-T0 of CG. Regarding PDA results of T4-T5, IG exhibited several significant differences compared to CG. In conclusion, this study suggests that two-implant overdentures with magnetic attachments, whether immediately or conventionally loaded, improve patient-reported outcomes. Immediate loading may have prolonged effects on the improvement of patient-reported outcomes.
- 25 October 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (21) , 11687
Open AccessImmediate Versus Conventional Loading of Two-Implant Overdenture with Magnetic Attachments: A 5-Year Follow-Up on Patient-Reported Outcomes
Comprehensive, long-term studies on patient-reported outcomes for two-implant overdentures with magnetic attachments using immediate or conventional loading methods are lacking. This study aimed to provide 5-year follow-up data comparing patient-reported outcomes for mandibular overdentures supported by two implants with magnetic attachments under immediate or conventional loading. Nineteen edentulous mandible patients were randomly assigned to immediate (IG) or conventional loading groups (CG). Two implants were placed with prostheses, loaded on the same day (immediate) or three months later (conventional). Participants completed questionnaires (oral health-related quality of life (OHRQoL), patient general satisfaction, and patient’s denture assessment (PDA)) at baseline and yearly intervals for 5 years. Results showed no significant differences between IG and CG throughout the study. However, the within-group analysis revealed significant improvements in OHRQoL, patient satisfaction, and all PDA domains from the baseline to years 1–5. Regarding patient satisfaction, significant differences were observed between T1, T2, and T3 when compared with T0 of IG and T1-T0 of CG. Regarding PDA results of T4-T5, IG exhibited several significant differences compared to CG. In conclusion, this study suggests that two-implant overdentures with magnetic attachments, whether immediately or conventionally loaded, improve patient-reported outcomes. Immediate loading may have prolonged effects on the improvement of patient-reported outcomes.
- 1 January 2018
- Published by Elsevier in Journal of Dentistry
- Vol. 68, 98-103
Cost-effectiveness analysis of two impression methods for the fabrication of mandibular complete dentures
- 1 January 2018
- Published by Elsevier in Journal of Dentistry
- Vol. 68, 98-103
Cost-effectiveness analysis of two impression methods for the fabrication of mandibular complete dentures