BCBing-Sheng Cao

Bing-Sheng Cao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Bing-Sheng Cao has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Xiao-Lin Li

    Department of Ultrasound, 309th Hospital of the Chinese PLA, Beijing, China

    3 shared publications
  • G.-C. Zhang

    1 shared publication
  • Geng-Chen Zhang Bd

    Department of Ultrasound, 309th Hospital of the Chinese PLA, Beijing, China

    1 shared publication
  • Gengchen Zhang

    Department of Ultrasound, Eighth Medical Center of Chinese PLA General Hospital, Beijing, China

    1 shared publication
  • Guo-Qing Liao

    Department of Oncology (G.-Q.L.), 309th Hospital of the Chinese PLA, Beijing, China; and Department of Pathology, 306th Hospital of the Chinese PLA, Beijing, China (J.-H.W.).

    1 shared publication
  • J. Deng

    1 shared publication

Latest Publications

  • Open Access

    Application of ultrasound-guided percutaneous nephrostomy in the treatment of a solitary kidney with hydronephrosis due to renal tuberculosis

    by Bingsong Zhang, Lei Li, Gengchen Zhang, Jinshan Wang, Bingsheng Cao, Zhuo Li

    Purpose: To investigate the value of ultrasound-guided percutaneous nephrostomy and nephrostomy tube replacement for treating a solitary kidney with hydronephrosis due to renal tuberculosis. Methods: Clinical data of patients with a solitary kidney with hydronephrosis caused by renal tuberculosis who underwent ultrasound-guided percutaneous nephrostomy in our hospital from January 2011 to December 2022 were retrospectively analyzed. The associated success rate and complications were statistically analyzed, pre- and post-catheterization changes in serum creatinine and blood urea nitrogen levels were compared, success rate and complications of nephrostomy tube replacement in patients with long-term catheterization were statistically analyzed, and the impact of long-term catheterization on patient life was investigated. Results: Overall, 32 patients aged 17–75 years (average age: 44.1 ± 16.9 years) underwent ultrasound-guided percutaneous nephrostomy. Sixty-three punctures were performed; the puncture success rate was 100%. The levels of serum creatinine and blood urea nitrogen of patients decreased after catheterization, and the differences between the pre-catheterization and post-catheterization were significant (P < 0.05). There were 1, 3, and 12 cases of serious, minor, and fistula-related complications, respectively. The mean duration of the indwelling catheter was 56.7 ± 36.2 (range, 13–120) months. The number of nephrostomy tube replacements was 344 times, and the success rate was 100%. All patients could take care of the puncture point by themselves. Conclusion: Ultrasound-guided percutaneous nephrostomy and nephrostomy tube replacement have a high success rate and few complications, which can improve the renal function of patients. It is of great value for treating a solitary kidney with hydronephrosis caused by renal tuberculosis.


  • Contrast-Enhanced Sonography of Juxtapleural Pulmonary Tuberculoma

    by J. Deng, G.-C. Zhang, Bing-Sheng Cao, Yu-Mei Liang, Xiao-Lin Li, Juan Deng Bd, Geng-Chen Zhang Bd


  • Open Access

    Sonographically Guided Transthoracic Biopsy of Peripheral Lung and Mediastinal Lesions

    by Bing-Sheng Cao, Ji-Hua Wu, Xiao-Lin Li, Juan Deng, Guo-Qing Liao

    Objectives The purpose of this study was to assess the impact of contrast‐enhanced sonography on sonographically guided transthoracic needle biopsy of lung lesions. Methods A total of 121 patients underwent sonographically guided transthoracic needle cutting biopsy. Of the 121 patients, 62 (contrast‐enhanced sonography group) underwent contrast‐enhanced sonography before biopsy, and the information from contrast‐enhanced sonography was used to optimize the biopsy procedure. The remaining 59 patients constituted the non–contrast‐enhanced sonography group. The enhancement patterns and echogenicity were evaluated by the consensus of 2 sonographers. The diagnostic efficacy was compared between the contrast‐enhanced and non–contrast‐enhanced sonography groups. Results The enhancement intensity and extent varied greatly among different thoracic lesions, and an anechoic area (necrosis) was revealed in 26 of 62 lesions (41.9%) lesions after administration of the contrast agent. The overall diagnostic accuracy of sonographically guided transthoracic biopsy in this study was 85.9% (104 of 121). In the contrast‐enhanced sonography group, the initial biopsy led to correct diagnosis in 58 of 62 lesions (93.6%). In the non–contrast‐enhanced sonography group, the initial biopsy led to correct diagnosis in 46 of 59 lesions (78.0%). The difference in the diagnostic accuracy between the contrast‐enhanced and non–contrast‐enhanced sonography groups was statistically significant (P < .05). Conclusions Contrast‐enhanced sonography enables differentiation of viable from necrotic portions of thoracic lesions and has a positive impact on the diagnostic efficacy of sonographically guided transthoracic needle biopsy.


  • The Nodular Form of Hepatic Tuberculosis

    by Bing-Sheng Cao, Xiao-Lin Li, Ning Li, Zhong-Yuan Wang

    Objective. The purposes of this study were to describe the ultrasonographic findings in hepatic tuberculosis (TB) after administration of a second-generation sulfur hexafluoride–filled microbubble co...