Jai Prakash Saini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jai Prakash Saini has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Yogendra Kumar Prajapati
Department of Electronics and Communication Engineering, Motilal Nehru National Institute of Technology Allahabad, Prayagraj, India
8 shared publications - Sarika Pal
Department of Electronics Engineering, National Institute of Technology Uttarakhand, Srinagar, India
7 shared publications - Alka Verma
Department of Electronics Engineering, Institute of Engineering and Rural Technology, Prayagraj, India
4 shared publications - Rajeev Kumar
National Institute of Technology
2 shared publications - Rajeev Kumar
Department of Electronics and Communication Engineering, Graphic Era (Deemed to be University), Dehradun 248001, Uttarakhand, India
2 shared publications - Anurag Upadhyay
Department of Applied Sciences & Humanities, Rajkiya Engineering College Azamgarh, Azamgarh, India
1 shared publication
Latest Publications
- 3 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (5) , 8375-8382
MXene-Enhanced Plasmonic Sensor Utilizing Planar Waveguide Modes and Long-Range Surface Plasmon Polaritons for Ultrasensitive Detection
In this article, a new hybrid structure of planar waveguide (PWG) and long-range surface plasmon resonance (LRSPR) sensor is analyzed analytically. The proposed sensor design comprised of 2S2G/Cytop/Silicon (Si)/Cytop/Silver(Ag)/MXene/sensing medium (SM). The proposed structure demonstrates normal mode splitting condition on strong coupling of PWG mode at Cytop-Si-Cytop interface and the LRSPR mode obtained at the Cytop-Ag-MXene-SM interface. The proposed PWG-LRSPR sensor accomplishes 42564 /RIU maximum imaging sensitivity when wave vector of both PWG and LRSPPs is matched. The imaging sensitivity and propagations length (PL) of the proposed PWG-LRSPR sensor is much higher than that of the conventional SPR and LRSPR sensor. The proposed sensor demonstrates a remarkable improvement in imaging sensitivity, outperforming sensor structures 1–5 and 7 by 97%, 22%, 96%, 56%, 47%, and 25%, respectively, while showing only a minor 1.7% reduction compared to sensor structure 6. Notably, it achieves the highest PL value of 1.0671 μm among all seven structures, maintaining exceptional sensitivity with minimal compromise. Transverse component of electric field (EF) variations at various layer interface of the proposed sensor design and other comparable seven sensor structures have also been analyzed. Hence, the proposed refractive index sensor can be suitably used for chemical and biochemical application whose RI lies in the vicinity of 1.33 to 1.34.
- 3 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (5) , 8375-8382
MXene-Enhanced Plasmonic Sensor Utilizing Planar Waveguide Modes and Long-Range Surface Plasmon Polaritons for Ultrasensitive Detection
In this article, a new hybrid structure of planar waveguide (PWG) and long-range surface plasmon resonance (LRSPR) sensor is analyzed analytically. The proposed sensor design comprised of 2S2G/Cytop/Silicon (Si)/Cytop/Silver(Ag)/MXene/sensing medium (SM). The proposed structure demonstrates normal mode splitting condition on strong coupling of PWG mode at Cytop-Si-Cytop interface and the LRSPR mode obtained at the Cytop-Ag-MXene-SM interface. The proposed PWG-LRSPR sensor accomplishes 42564 /RIU maximum imaging sensitivity when wave vector of both PWG and LRSPPs is matched. The imaging sensitivity and propagations length (PL) of the proposed PWG-LRSPR sensor is much higher than that of the conventional SPR and LRSPR sensor. The proposed sensor demonstrates a remarkable improvement in imaging sensitivity, outperforming sensor structures 1–5 and 7 by 97%, 22%, 96%, 56%, 47%, and 25%, respectively, while showing only a minor 1.7% reduction compared to sensor structure 6. Notably, it achieves the highest PL value of 1.0671 μm among all seven structures, maintaining exceptional sensitivity with minimal compromise. Transverse component of electric field (EF) variations at various layer interface of the proposed sensor design and other comparable seven sensor structures have also been analyzed. Hence, the proposed refractive index sensor can be suitably used for chemical and biochemical application whose RI lies in the vicinity of 1.33 to 1.34.
- 5 October 2022
- Published by Springer Nature
- p. 467-477
Performance Analysis of LiF and Graphene Based Long-Range SPR Sensor
- 5 October 2022
- Published by Springer Nature
- p. 467-477
Performance Analysis of LiF and Graphene Based Long-Range SPR Sensor
- 5 October 2022
- Published by Springer Nature
- p. 151-164
Sensitivity Enhancement of Ti3C2Tx Based Bimetallic SPR Biosensor Using SiO2
- 5 October 2022
- Published by Springer Nature
- p. 151-164
Sensitivity Enhancement of Ti3C2Tx Based Bimetallic SPR Biosensor Using SiO2
- Top Cited Papers
- 24 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (7) , 6536-6543
Sensitivity Improvement of a MXene- Immobilized SPR Sensor With Ga-Doped-ZnO for Biomolecules Detection
This work presents a surface plasmon resonance (SPR) sensor based on Gallium (Ga)-doped-Zinc oxide (ZnO) and Ti 3 C 2 T x (MXene) for sensitivity enhancement. The smaller resistivity and high conductivity of the pulsed layer deposited Ga-doped-ZnO are used to improve the sensitivity up to (264.59 °/RIU). The detection accuracy (0.1152°) and figure of merit (30.48 RIU −1 ) are also evaluated for the proposed sensor. The effects of using different prisms (SiO 2 , BaF 2 , CsF, and BK7), plasmonic metals (Au, Ag, Cu, and Al) and doping in ZnO (intermediate layer) on the performance parameters of the proposed SPR sensor are investigated for comparative analysis. The comparative performance analysis presents the maximum sensitivity for the SPR sensor structure: Prism SiO 2 /Au/Ga-doped-ZnO/MXene. The field distribution at different layer interfaces of the SPR sensor configurations has also been analyzed using FEM simulations. This work is suitable for the detection of biomolecules and biochemicals
- 24 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (7) , 6536-6543
Top Cited PapersSensitivity Improvement of a MXene- Immobilized SPR Sensor With Ga-Doped-ZnO for Biomolecules Detection
This work presents a surface plasmon resonance (SPR) sensor based on Gallium (Ga)-doped-Zinc oxide (ZnO) and Ti 3 C 2 T x (MXene) for sensitivity enhancement. The smaller resistivity and high conductivity of the pulsed layer deposited Ga-doped-ZnO are used to improve the sensitivity up to (264.59 °/RIU). The detection accuracy (0.1152°) and figure of merit (30.48 RIU −1 ) are also evaluated for the proposed sensor. The effects of using different prisms (SiO 2 , BaF 2 , CsF, and BK7), plasmonic metals (Au, Ag, Cu, and Al) and doping in ZnO (intermediate layer) on the performance parameters of the proposed SPR sensor are investigated for comparative analysis. The comparative performance analysis presents the maximum sensitivity for the SPR sensor structure: Prism SiO 2 /Au/Ga-doped-ZnO/MXene. The field distribution at different layer interfaces of the SPR sensor configurations has also been analyzed using FEM simulations. This work is suitable for the detection of biomolecules and biochemicals
- 20 April 2021
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 53 (5) , 1-15
Figure of merit enhancement of Ti3C2Tx-graphene based long-range surface plasmon sensor at telecommunication wavelength
- 20 April 2021
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 53 (5) , 1-15
Figure of merit enhancement of Ti3C2Tx-graphene based long-range surface plasmon sensor at telecommunication wavelength
- 11 January 2021
- Published by Springer Nature in Applied Physics A
- Vol. 127 (2) , 1-8
2D-antimonene-based surface plasmon resonance sensor for improvement of sensitivity
- 11 January 2021
- Published by Springer Nature in Applied Physics A
- Vol. 127 (2) , 1-8
2D-antimonene-based surface plasmon resonance sensor for improvement of sensitivity
- 24 September 2020
- Published by Springer Nature in Applied Physics A
- Vol. 126 (10) , 1-10
Sensitive detection using heterostructure of black phosphorus, transition metal di-chalcogenides and MXene in SPR sensor
- 24 September 2020
- Published by Springer Nature in Applied Physics A
- Vol. 126 (10) , 1-10
Sensitive detection using heterostructure of black phosphorus, transition metal di-chalcogenides and MXene in SPR sensor
- 10 July 2020
- Published by Springer Nature in Silicon
- Vol. 13 (6) , 1887-1894
Sensitivity Enhancement of MXene Based SPR Sensor Using Silicon: Theoretical Analysis
- 10 July 2020
- Published by Springer Nature in Silicon
- Vol. 13 (6) , 1887-1894
Sensitivity Enhancement of MXene Based SPR Sensor Using Silicon: Theoretical Analysis
- 30 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 4 (7) , 1-4
Sensitivity Improvement of Surface Plasmon Resonance Sensor on Using BlueP/MoS2 Heterostructure and Antimonene
Here, an ultrasensitive SPR sensor based on angular interrogation using antimonene and BlueP/MoS2 heterostructure is proposed. Antimonene is used as interacting layer due to its higher binding energy for analytes than graphene. BlueP/MoS2 enhances sensitivity by manipulating charge transfer to metal/dielectric interface. Sensitivity is analyzed by tuning of heterostructure, antimonene layers and for wide range of analyte refractive index. Highest sensitivity of 198.4/RIU is achieved for three layers of BlueP/MoS2. Results show significant sensitivity for proposed design than conventional and graphene based SPR sensor. Proposed SPR sensor can be successfully developed as SPR chip for biomolecule/analyte detection in visible range.
- 30 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 4 (7) , 1-4
Sensitivity Improvement of Surface Plasmon Resonance Sensor on Using BlueP/MoS2 Heterostructure and Antimonene
Here, an ultrasensitive SPR sensor based on angular interrogation using antimonene and BlueP/MoS2 heterostructure is proposed. Antimonene is used as interacting layer due to its higher binding energy for analytes than graphene. BlueP/MoS2 enhances sensitivity by manipulating charge transfer to metal/dielectric interface. Sensitivity is analyzed by tuning of heterostructure, antimonene layers and for wide range of analyte refractive index. Highest sensitivity of 198.4/RIU is achieved for three layers of BlueP/MoS2. Results show significant sensitivity for proposed design than conventional and graphene based SPR sensor. Proposed SPR sensor can be successfully developed as SPR chip for biomolecule/analyte detection in visible range.
- 1 August 2015
- Published by Elsevier in Optics Communications
- Vol. 348, 71-76
Comprehensive study of reverse index waveguide based sensor with metamaterial as a guiding layer
- 1 August 2015
- Published by Elsevier in Optics Communications
- Vol. 348, 71-76
Comprehensive study of reverse index waveguide based sensor with metamaterial as a guiding layer