Chong Yeh Sai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chong Yeh Sai has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Norrima Mokhtar
University of Malaya
3 shared publications Hamzah Arof
Department of Electrical Engineering Faculty of Engineering University of Malaya Kuala Lumpur Malaysia
2 shared publicationsMasahiro Iwahashi
Department of Electrical Engineering Faculty of Technology Nagaoka University of Technology Nagaoka Japan
2 shared publications- Paul Cumming
School of Psychology and Counselling, Queensland University of Technology, Brisbane, Australia
2 shared publications - Hamzah Arof
Department of Electrical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
1 shared publication - Hing Wa Yip
Department of Anaesthesiology, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia
1 shared publication
Latest Publications
- Open Access
- 12 June 2021
- Published by Institution of Engineering and Technology (IET) in IET Signal Processing
- Vol. 15 (8) , 535-542
Fully automated unsupervised artefact removal in multichannel electroencephalogram using wavelet‐independent component analysis with density‐based spatial clustering of application with noise
Electroencephalography (EEG) is a method for recording electrical activities arising from the cortical surface of the brain, which has found wide applications not just in clinical medicine, but also in neuroscience research and studies of Brain‐Computer Interface (BCI). However, EEG recordings often suffer from distortions due to artefactual components that degrade the true EEG signals. Artefactual components are any unwanted signals recorded in the EEG spectrum that originate from sources other than the neurophysiological activity of the human brain. Examples of the origin of artefactual components include eye blinking, facial or scalp muscles activities, and electrode slippage. Techniques for automated artefact removal such as Wavelet Transform and Independent Component Analysis (ICA) have been used to remove or reduce the effect of artefactual components on the EEG signals. However, detecting or identifying the signal artefacts to be removed presents a great challenge, as EEG signal properties vary between individuals and age groups. Techniques that rely on some arbitrarily defined threshold often fail to identify accurately the signal artefacts in a given dataset. In this study, a method is proposed using unsupervised machine learning coupled with Wavelet‐ICA to remove EEG artefacts. Using Density‐Based Spatial Clustering of Application with Noise (DBSCAN), a classification accuracy of 97.9% is achieved in identifying artefactual components. DBSCAN achieved excellent and robust performance in identifying artefactual components during the Wavelet‐ICA process, especially in consideration of the low‐density nature of typical artefactual signals. This new hybrid method provides a scalable and unsupervised solution for automated artefact removal that should be applicable for a wide range of EEG data types.
- 12 June 2021
- Published by Institution of Engineering and Technology (IET) in IET Signal Processing
- Vol. 15 (8) , 535-542
Open AccessFully automated unsupervised artefact removal in multichannel electroencephalogram using wavelet‐independent component analysis with density‐based spatial clustering of application with noise
Electroencephalography (EEG) is a method for recording electrical activities arising from the cortical surface of the brain, which has found wide applications not just in clinical medicine, but also in neuroscience research and studies of Brain‐Computer Interface (BCI). However, EEG recordings often suffer from distortions due to artefactual components that degrade the true EEG signals. Artefactual components are any unwanted signals recorded in the EEG spectrum that originate from sources other than the neurophysiological activity of the human brain. Examples of the origin of artefactual components include eye blinking, facial or scalp muscles activities, and electrode slippage. Techniques for automated artefact removal such as Wavelet Transform and Independent Component Analysis (ICA) have been used to remove or reduce the effect of artefactual components on the EEG signals. However, detecting or identifying the signal artefacts to be removed presents a great challenge, as EEG signal properties vary between individuals and age groups. Techniques that rely on some arbitrarily defined threshold often fail to identify accurately the signal artefacts in a given dataset. In this study, a method is proposed using unsupervised machine learning coupled with Wavelet‐ICA to remove EEG artefacts. Using Density‐Based Spatial Clustering of Application with Noise (DBSCAN), a classification accuracy of 97.9% is achieved in identifying artefactual components. DBSCAN achieved excellent and robust performance in identifying artefactual components during the Wavelet‐ICA process, especially in consideration of the low‐density nature of typical artefactual signals. This new hybrid method provides a scalable and unsupervised solution for automated artefact removal that should be applicable for a wide range of EEG data types.
- 21 March 2019
- Published by Springer Nature in Sādhanā
- Vol. 44 (4) , 1-12
Objective identification of pain due to uterine contraction during the first stage of labour using continuous EEG signals and SVM
- 21 March 2019
- Published by Springer Nature in Sādhanā
- Vol. 44 (4) , 1-12
Objective identification of pain due to uterine contraction during the first stage of labour using continuous EEG signals and SVM
- Top Cited Papers
- 4 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 22 (3) , 664-670
Automated Classification and Removal of EEG Artifacts With SVM and Wavelet-ICA
Brain electrical activity recordings by electroencephalography (EEG) are often contaminated with signal artifacts. Procedures for automated removal of EEG artifacts are frequently sought for clinical diagnostics and brain-computer interface applications. In recent years, a combination of independent component analysis (ICA) and discrete wavelet transform has been introduced as standard technique for EEG artifact removal. However, in performing the wavelet-ICA procedure, visual inspection or arbitrary thresholding may be required for identifying artifactual components in the EEG signal. We now propose a novel approach for identifying artifactual components separated by wavelet-ICA using a pretrained support vector machine (SVM). Our method presents a robust and extendable system that enables fully automated identification and removal of artifacts from EEG signals, without applying any arbitrary thresholding. Using test data contaminated by eye blink artifacts, we show that our method performed better in identifying artifactual components than did existing thresholding methods. Furthermore, wavelet-ICA in conjunction with SVM successfully removed target artifacts, while largely retaining the EEG source signals of interest. We propose a set of features including kurtosis, variance, Shannon's entropy, and range of amplitude as training and test data of SVM to identify eye blink artifacts in EEG signals. This combinatorial method is also extendable to accommodate multiple types of artifacts present in multichannel EEG. We envision future research to explore other descriptive features corresponding to other types of artifactual components.
- 4 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 22 (3) , 664-670
Top Cited PapersAutomated Classification and Removal of EEG Artifacts With SVM and Wavelet-ICA
Brain electrical activity recordings by electroencephalography (EEG) are often contaminated with signal artifacts. Procedures for automated removal of EEG artifacts are frequently sought for clinical diagnostics and brain-computer interface applications. In recent years, a combination of independent component analysis (ICA) and discrete wavelet transform has been introduced as standard technique for EEG artifact removal. However, in performing the wavelet-ICA procedure, visual inspection or arbitrary thresholding may be required for identifying artifactual components in the EEG signal. We now propose a novel approach for identifying artifactual components separated by wavelet-ICA using a pretrained support vector machine (SVM). Our method presents a robust and extendable system that enables fully automated identification and removal of artifacts from EEG signals, without applying any arbitrary thresholding. Using test data contaminated by eye blink artifacts, we show that our method performed better in identifying artifactual components than did existing thresholding methods. Furthermore, wavelet-ICA in conjunction with SVM successfully removed target artifacts, while largely retaining the EEG source signals of interest. We propose a set of features including kurtosis, variance, Shannon's entropy, and range of amplitude as training and test data of SVM to identify eye blink artifacts in EEG signals. This combinatorial method is also extendable to accommodate multiple types of artifacts present in multichannel EEG. We envision future research to explore other descriptive features corresponding to other types of artifactual components.