Brajesh K. Shukla
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Brajesh K. Shukla has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- David J. Hewson
Institute for Health Research University of Bedfordshire Luton UK
3 shared publications - Sandeep Kumar Yadav
Department of Electrical Engineering, Indian Institute of Technology Jodhpur, Jodhpur, India
3 shared publications - Arvind Mathur
Ex-Principal, Dr S N Medical College, Jodhpur, Rajasthan, India
2 shared publications - Jennifer N. C. Bassement
Human and Life Sciences, Laboratoire d’Automatique, de Mécanique et d’Informatique industrielles et Humaines, Université Polytechnique Hauts-de-France, 59300 Valenciennes, France
2 shared publications - Vivek Vijay
Indian Institute of Technology Jodhpur
2 shared publications - Hiteshi Jain
Mercedes Benz R&D, Bengaluru, India
1 shared publication
Latest Publications
- Open Access
- 6 November 2020
- Published by MDPI AG in Bioengineering
- Vol. 7 (4) , 139
Instrumented Analysis of the Sit-to-Stand Movement for Geriatric Screening: A Systematic Review
The Sit-to-Stand (STS) is a widely used test of physical function to screen older people at risk of falls and frailty and is also one of the most important components of standard screening for sarcopenia. There have been many recent studies in which instrumented versions of the STS (iSTS) have been developed to provide additional parameters that could improve the accuracy of the STS test. This systematic review aimed to identify whether an iSTS is a viable alternative to a standard STS to identify older people at risk of falling, frailty, and sarcopenia. A total of 856 articles were found using the search strategy developed, with 12 articles retained in the review after screening based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Six studies evaluated the iSTS in fallers, five studies in frailty and only one study in both fallers and frailty. The results showed that power and velocity parameters extracted from an iSTS have the potential to improve the accuracy of screening when compared to a standard STS. Future work should focus on standardizing the segmentation of the STS into phases to enable comparison between studies and to develop devices integrated into the chair used for the test to improve usability.
- 6 November 2020
- Published by MDPI AG in Bioengineering
- Vol. 7 (4) , 139
Open AccessInstrumented Analysis of the Sit-to-Stand Movement for Geriatric Screening: A Systematic Review
The Sit-to-Stand (STS) is a widely used test of physical function to screen older people at risk of falls and frailty and is also one of the most important components of standard screening for sarcopenia. There have been many recent studies in which instrumented versions of the STS (iSTS) have been developed to provide additional parameters that could improve the accuracy of the STS test. This systematic review aimed to identify whether an iSTS is a viable alternative to a standard STS to identify older people at risk of falling, frailty, and sarcopenia. A total of 856 articles were found using the search strategy developed, with 12 articles retained in the review after screening based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Six studies evaluated the iSTS in fallers, five studies in frailty and only one study in both fallers and frailty. The results showed that power and velocity parameters extracted from an iSTS have the potential to improve the accuracy of screening when compared to a standard STS. Future work should focus on standardizing the segmentation of the STS into phases to enable comparison between studies and to develop devices integrated into the chair used for the test to improve usability.
- 17 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 28 (6) , 1317-1324
A Comparison of Four Approaches to Evaluate the Sit-to-Stand Movement
The sit-to-stand test (STS) is a simple test of function in older people that can identify people at risk of falls. The aim of this study was to develop two novel methods of evaluating performance in the STS using a low-cost RGB camera and another an instrumented chair containing load cells in the seat of the chair to detect center of pressure movements and ground reaction forces. The two systems were compared to a Kinect and a force plate. Twenty-one younger subjects were tested when performing two 5STS movements at self-selected slow and normal speeds while 16 older fallers were tested when performing one 5STS at a selfselected pace. All methods had acceptable limits of agreement with an expert for total STS time for younger subjects and older fallers, with smaller errors observed for the chair (-0.18 ± 0.17 s) and force plate (-0.19 ± 0.79 s) than for the RGB camera (-0.30 ± 0.51 s) and the Kinect (-0.38 ± 0.50 s) for older fallers. The chair had the smallest limits of agreement compared to the expert for both younger and older participants. The new device was also able to estimate movement velocity, which could be used to estimate muscle power during the STS movement. Subsequent studies will test the device against opto-electronic systems, incorporate additional sensors, and then develop predictive equations for measures of physical function.
- 17 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 28 (6) , 1317-1324
A Comparison of Four Approaches to Evaluate the Sit-to-Stand Movement
The sit-to-stand test (STS) is a simple test of function in older people that can identify people at risk of falls. The aim of this study was to develop two novel methods of evaluating performance in the STS using a low-cost RGB camera and another an instrumented chair containing load cells in the seat of the chair to detect center of pressure movements and ground reaction forces. The two systems were compared to a Kinect and a force plate. Twenty-one younger subjects were tested when performing two 5STS movements at self-selected slow and normal speeds while 16 older fallers were tested when performing one 5STS at a selfselected pace. All methods had acceptable limits of agreement with an expert for total STS time for younger subjects and older fallers, with smaller errors observed for the chair (-0.18 ± 0.17 s) and force plate (-0.19 ± 0.79 s) than for the RGB camera (-0.30 ± 0.51 s) and the Kinect (-0.38 ± 0.50 s) for older fallers. The chair had the smallest limits of agreement compared to the expert for both younger and older participants. The new device was also able to estimate movement velocity, which could be used to estimate muscle power during the STS movement. Subsequent studies will test the device against opto-electronic systems, incorporate additional sensors, and then develop predictive equations for measures of physical function.
- Open Access
- 13 April 2020
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 142 (9)
A Pilot Study to Detect Balance Impairment in Older Adults Using an Instrumented One-Leg Stance Test
The aim of this study was to investigate whether parameters from an instrumented one-leg stance (OLS) on a force plate could provide relevant information related to fall risk in older people. Forty-two community dwelling older people including 17 fallers and 25 nonfallers, and 25 young subjects performed a OLS while standing on a force plate, with parameters related to transferring weight onto one leg and postural sway in singe-leg stance evaluated. No differences were observed between older fallers and nonfallers and the younger participants for any of the weight transfer parameters. The younger participants were able to reduce their postural sway during the OLS test after the first 0–2 s period, unlike older participants who swayed the same amount throughout the test. The older fallers swayed significantly more than both nonfallers and younger participants throughout the 10-s of OLS evaluated. When the tests were used to classify older participants as fallers, the instrumented OLS achieved 100% accuracy, compared to 69.0% classification accuracy for the five times sit-to-stand test, 61.9% for the standard OLS, and 47.6% for the timed-up-and-go test. These findings suggest that the standard OLS test might not be suitable to detect fall risk. In contrast, an instrumented version of the OLS could provide valuable additional information that could identify older fallers. Future work will include a prospective study of the instrumented OLS in a larger population of older people.
- 13 April 2020
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 142 (9)
Open AccessA Pilot Study to Detect Balance Impairment in Older Adults Using an Instrumented One-Leg Stance Test
The aim of this study was to investigate whether parameters from an instrumented one-leg stance (OLS) on a force plate could provide relevant information related to fall risk in older people. Forty-two community dwelling older people including 17 fallers and 25 nonfallers, and 25 young subjects performed a OLS while standing on a force plate, with parameters related to transferring weight onto one leg and postural sway in singe-leg stance evaluated. No differences were observed between older fallers and nonfallers and the younger participants for any of the weight transfer parameters. The younger participants were able to reduce their postural sway during the OLS test after the first 0–2 s period, unlike older participants who swayed the same amount throughout the test. The older fallers swayed significantly more than both nonfallers and younger participants throughout the 10-s of OLS evaluated. When the tests were used to classify older participants as fallers, the instrumented OLS achieved 100% accuracy, compared to 69.0% classification accuracy for the five times sit-to-stand test, 61.9% for the standard OLS, and 47.6% for the timed-up-and-go test. These findings suggest that the standard OLS test might not be suitable to detect fall risk. In contrast, an instrumented version of the OLS could provide valuable additional information that could identify older fallers. Future work will include a prospective study of the instrumented OLS in a larger population of older people.