Seongjin Choi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Seongjin Choi has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Byungwhan Kim
Sejong University
1 shared publication - Hyeong-Cheol Oh
Departement of Electronics and Information Engineering, Korea University Sejong Campus, Sejong, South Korea
1 shared publication J. Robert Boston
Department of Electrical Engineering, University of Pittsburgh; and
1 shared publicationJames F. Antaki
Department of Biomedical Engineering and Computer Science, Carnegie Mellon University, Pittsburgh, PA, USA
1 shared publication
Latest Publications
- 28 December 2024
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 20 (4) , 1975-1982
Estimating Operating Points in Wind Power Systems Using Cluster Centers
- 28 December 2024
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 20 (4) , 1975-1982
Estimating Operating Points in Wind Power Systems Using Cluster Centers
- 13 June 2012
- Published by Springer Nature in International Journal of Control, Automation, and Systems
- Vol. 10 (3) , 644-650
Regulation of plasma discharge using fuzzy logic and an in-situ plasma sensor
- 13 June 2012
- Published by Springer Nature in International Journal of Control, Automation, and Systems
- Vol. 10 (3) , 644-650
Regulation of plasma discharge using fuzzy logic and an in-situ plasma sensor
- 12 February 2007
- Published by Wiley in Artificial Organs
- Vol. 31 (2) , 114-125
Hemodynamic Controller for Left Ventricular Assist Device Based on Pulsatility Ratio
Abstract: Hemodynamic control of left ventricular assist devices (LVADs) is generally a complicated problem due to diverse operating environments and the variability of the patients: both the changes in the circulatory and metabolic parameters as well as disturbances that require adjustment to the operating point. This challenge is especially acute with control of turbodynamic blood pumps. This article presents a pulsatility ratio controller for LVAD that provides a proper perfusion according to the physiological demands of the patient, while avoiding adverse conditions. It utilizes the pulsatility ratio of the flow through the pump and pressure difference across the pump as a control index and adjusts the pump speed according to the reference pulsatility ratio under the different operating conditions. The simulation studies were performed to evaluate the controller in consideration of the sensitivity to afterload and preload, influence of the contractility, and effect of suction sensitivity. The controller successfully adjusts the pump speed according to the reference pulsatility ratio, and supports the natural heart under diverse pump operating conditions. The resulting safe pump operations demonstrate the solid performance of the controller in terms of sensitivity to afterload and preload, influence of the contractility, and effect of suction sensitivity.
- 12 February 2007
- Published by Wiley in Artificial Organs
- Vol. 31 (2) , 114-125
Hemodynamic Controller for Left Ventricular Assist Device Based on Pulsatility Ratio
Abstract: Hemodynamic control of left ventricular assist devices (LVADs) is generally a complicated problem due to diverse operating environments and the variability of the patients: both the changes in the circulatory and metabolic parameters as well as disturbances that require adjustment to the operating point. This challenge is especially acute with control of turbodynamic blood pumps. This article presents a pulsatility ratio controller for LVAD that provides a proper perfusion according to the physiological demands of the patient, while avoiding adverse conditions. It utilizes the pulsatility ratio of the flow through the pump and pressure difference across the pump as a control index and adjusts the pump speed according to the reference pulsatility ratio under the different operating conditions. The simulation studies were performed to evaluate the controller in consideration of the sensitivity to afterload and preload, influence of the contractility, and effect of suction sensitivity. The controller successfully adjusts the pump speed according to the reference pulsatility ratio, and supports the natural heart under diverse pump operating conditions. The resulting safe pump operations demonstrate the solid performance of the controller in terms of sensitivity to afterload and preload, influence of the contractility, and effect of suction sensitivity.