F. Linming
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
F. Linming has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
C. Yuanyu
Department of Dermatovenereology, West China Hospital, Sichuan University, Chengdu, China
1 shared publicationH. Wei
Department of Dermatovenereology, West China Hospital, Sichuan University, Chengdu, China
1 shared publicationL. Anqi
Department of Dermatovenereology, West China Hospital, Sichuan University, Chengdu, China
1 shared publicationL. Yiming
Department of Dermatovenereology, West China Hospital, Sichuan University, Chengdu, China
1 shared publication- Li Li
Department of Dermatology West China Hospital Sichuan University Chengdu China
1 shared publication P. Sushmita
Department of Dermatovenereology, West China Hospital, Sichuan University, Chengdu, China
1 shared publication
Latest Publications
- 5 June 2017
- Published by Wiley in Skin Research and Technology
- Vol. 24 (1) , 3-8
Comparison of two skin imaging analysis instruments: TheVISIA®from Canfield vs theANTERA3D®CSfrom Miravex
Background: The skin imaging analysis instruments are widely used to record and measure the surface and subsurface skin conditions. The main aim of this study is to reveal the differences and correlations in measuring wrinkle, skin texture, coloration/evenness, vascular features, and pore between two commercially available instruments.Methods: Twenty‐eight subjects were enrolled in the study. A 2*2 cm cardboard was used to make sure the two instruments analyze the same area. Pictures were taken and analyzed by theVISIA®from Canfield and theANTERA3D®CSfrom Miravex, in sequence.Results: The spot, ultraviolet spot, brown spot, red area, texture values measured withVISIA®were positively correlated with age, while the pore and wrinkle values showed no significance. The wrinkle, texture, melanin, hemoglobin, pore index, pore volume values measured withANTERA3D®had a significantly positive correlation with age. The spot, brown spot values fromVISIA®were positively correlated with the melanin value fromANTERA3D®. Texture value measured with the two instruments revealed positive linear correlation. Strong correlation was found between the red area value fromVISIA®and the hemoglobin value fromANTERA3D®. Ultraviolet spot fromVISIA®showed no linear correlation with the melanin value fromANTERA3D®. Neither of the wrinkle and pore measured with the two instruments showed linear correlation.Conclusions: ANTERA3D®relies on multidirectional illumination obtained byLEDs of different wavelengths from different directions which make it advanced at the qualitative evaluation of various dermatologic conditions. Compared withVISIA®,ANTERA3D®is more sensitive in the assessment of wrinkle and it may also be available to evaluate the aging‐related enlarged pore.
- 5 June 2017
- Published by Wiley in Skin Research and Technology
- Vol. 24 (1) , 3-8
Comparison of two skin imaging analysis instruments: TheVISIA®from Canfield vs theANTERA3D®CSfrom Miravex
Background: The skin imaging analysis instruments are widely used to record and measure the surface and subsurface skin conditions. The main aim of this study is to reveal the differences and correlations in measuring wrinkle, skin texture, coloration/evenness, vascular features, and pore between two commercially available instruments.Methods: Twenty‐eight subjects were enrolled in the study. A 2*2 cm cardboard was used to make sure the two instruments analyze the same area. Pictures were taken and analyzed by theVISIA®from Canfield and theANTERA3D®CSfrom Miravex, in sequence.Results: The spot, ultraviolet spot, brown spot, red area, texture values measured withVISIA®were positively correlated with age, while the pore and wrinkle values showed no significance. The wrinkle, texture, melanin, hemoglobin, pore index, pore volume values measured withANTERA3D®had a significantly positive correlation with age. The spot, brown spot values fromVISIA®were positively correlated with the melanin value fromANTERA3D®. Texture value measured with the two instruments revealed positive linear correlation. Strong correlation was found between the red area value fromVISIA®and the hemoglobin value fromANTERA3D®. Ultraviolet spot fromVISIA®showed no linear correlation with the melanin value fromANTERA3D®. Neither of the wrinkle and pore measured with the two instruments showed linear correlation.Conclusions: ANTERA3D®relies on multidirectional illumination obtained byLEDs of different wavelengths from different directions which make it advanced at the qualitative evaluation of various dermatologic conditions. Compared withVISIA®,ANTERA3D®is more sensitive in the assessment of wrinkle and it may also be available to evaluate the aging‐related enlarged pore.