Kelmo L. Braga
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kelmo L. Braga has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Edson Ramos Andrade
Military Institute of Engineering
6 shared publications - Marcos Paulo C. Medeiros
Nuclear Engineering Graduate Program, Military Institute of Engineering (IME)
3 shared publications - Wilson F. Rebello
Rio de Janeiro State University, Faculty of Engineering and IBRAG, Rio de Janeiro, Brazil
3 shared publications Ademir X. Silva
Nuclear Engineering Graduate Program, Federal University of Rio de Janeiro (COPPE/UFRJ), Rio de Janeiro, Brazil
2 shared publications- Ademir Xavier Da Silva
Nuclear Engineering Graduate Program, Federal University of Rio de Janeiro (COPPE/UFRJ), Rio de Janeiro, Brazil
2 shared publications - Delson Braz
Nuclear Engineering Graduate Program, Federal University of Rio de Janeiro (COPPE/UFRJ), Av. Horácio Macedo, 2030, Bloco G - Sala 206 - CT, Fundão, 21941-914, Rio de Janeiro, Brazil
2 shared publications
Latest Publications
- 5 January 2022
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 181, 110095
Influence of radiotherapy room shielding on ambient dose equivalent due to photons H*(10)p and neutrons H*(10)n in the patient’s plane
- 5 January 2022
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 181, 110095
Influence of radiotherapy room shielding on ambient dose equivalent due to photons H*(10)p and neutrons H*(10)n in the patient’s plane
- 1 December 2021
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 178, 109967
MCNPX computational modeling applied to the potential dose rates calculation of cargo scanning
- 1 December 2021
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 178, 109967
MCNPX computational modeling applied to the potential dose rates calculation of cargo scanning
- 1 November 2020
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 165, 109332
Modeling of a neutron irradiator using Monte Carlo
- 1 November 2020
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 165, 109332
Modeling of a neutron irradiator using Monte Carlo
- 30 September 2020
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 6 (6) , 065016
Brazilian regulatory authority contribution to the shielding dimensioning model of radiotherapy rooms proposed by the NCRP 151
The National Council on Radiation Protection and Measurements (NCRP) Report No. 151 is an essential document for bunker design commonly applied for radiotherapy treatment rooms. This document is used as a reference by several countries, including Brazil. The objective of this study is to evaluate the shielding dimensioning methodology recommended by NCRP 151, and compare it with the one adopted by the Brazilian regulatory authority. Radiotherapy rooms and respective doors were designed to use linear accelerators operating at 6, 10, 15, and 18 MeV under two different ways: (a) applying exclusively the methodology recommended by the NCRP 151, and (b) taking into consideration the complementary recommendations from the Brazilian authorities. The results suggest that designers in Brazil can count on at least 4 and 11% safety margin for dimensioning primary barriers in controlled and free areas respectively. Also 8% for secondary barriers in controlled areas, 9.7% for secondary barriers adjacent to the primary belt of free areas, and 6.6% for the lead of the doors.
- 30 September 2020
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 6 (6) , 065016
Brazilian regulatory authority contribution to the shielding dimensioning model of radiotherapy rooms proposed by the NCRP 151
The National Council on Radiation Protection and Measurements (NCRP) Report No. 151 is an essential document for bunker design commonly applied for radiotherapy treatment rooms. This document is used as a reference by several countries, including Brazil. The objective of this study is to evaluate the shielding dimensioning methodology recommended by NCRP 151, and compare it with the one adopted by the Brazilian regulatory authority. Radiotherapy rooms and respective doors were designed to use linear accelerators operating at 6, 10, 15, and 18 MeV under two different ways: (a) applying exclusively the methodology recommended by the NCRP 151, and (b) taking into consideration the complementary recommendations from the Brazilian authorities. The results suggest that designers in Brazil can count on at least 4 and 11% safety margin for dimensioning primary barriers in controlled and free areas respectively. Also 8% for secondary barriers in controlled areas, 9.7% for secondary barriers adjacent to the primary belt of free areas, and 6.6% for the lead of the doors.
- 1 September 2020
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 163, 109163
Shielding implications on secondary radiation doses in prostate cancer treatment
- 1 September 2020
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 163, 109163
Shielding implications on secondary radiation doses in prostate cancer treatment
- 1 June 2020
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 160, 109130
Study on radiation dosimetry and radioprotection applied to Seaport Cargo Inspection Activity
- 1 June 2020
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 160, 109130
Study on radiation dosimetry and radioprotection applied to Seaport Cargo Inspection Activity
- 1 January 2018
- Published by EDP Sciences in Radioprotection
- Vol. 53 (1) , 27-31
Selective contribution of concrete shielding on the equivalent and effective doses in a prostate radiotherapy treatment
Within a radiotherapy room, in addition to the primary beam, there is also secondary radiation that leaks from the accelerator head and scattering caused by surrounding objects, the patient’s body and even the walls of the shielded room itself, designed to protect the external individuals, disregarding effects on the patient. The aim of this work is to study the radiation effect on the patient’s healthy tissues caused by scattering from a concrete shield expressed as equivalent and effective doses. MCNPX simulations of the linear accelerator Varian 2100/2300C/D were performed for a MAX phantom of a patient in a typical radiotherapy room. In addition, calculations were made with and without shielding. It was concluded that the concrete shielding affects in 5% the effective dose absorbed by the patient.
- 1 January 2018
- Published by EDP Sciences in Radioprotection
- Vol. 53 (1) , 27-31
Selective contribution of concrete shielding on the equivalent and effective doses in a prostate radiotherapy treatment
Within a radiotherapy room, in addition to the primary beam, there is also secondary radiation that leaks from the accelerator head and scattering caused by surrounding objects, the patient’s body and even the walls of the shielded room itself, designed to protect the external individuals, disregarding effects on the patient. The aim of this work is to study the radiation effect on the patient’s healthy tissues caused by scattering from a concrete shield expressed as equivalent and effective doses. MCNPX simulations of the linear accelerator Varian 2100/2300C/D were performed for a MAX phantom of a patient in a typical radiotherapy room. In addition, calculations were made with and without shielding. It was concluded that the concrete shielding affects in 5% the effective dose absorbed by the patient.