S. Saitoh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
S. Saitoh has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
K. Harada
1 shared publicationS. Shimanuki
1 shared publicationT. Kobayashi
1 shared publicationT. Takeuchi
1 shared publicationY. Yamashita
1 shared publication
Latest Publications
- 1 March 1999
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 46 (2) , 414-421
A 3.7 MHz phased array probe using 0.91Pb(Zn/sub 1/3/Nb/sub 2/3/)O/sub 3/-0.09PbTiO/sub 3/
A novel 128-channel phased array probe for echocardiography with a center frequency of 3.7 MHz using 0.91Pb(Zn/sub 1/3/Nb/sub 2/3/)O/sub 3/-0.09PbTiO/sub 3/ (PZN-9%PT) single crystal has been fabricated to realize greater sensitivity and broader bandwidth properties. The echo amplitude of the PZN-9%PT single-crystal probe is about 5 dB higher than that of the conventional lead airconate titanate (PZT) ceramic probe, and the fractional bandwidth is about 25 percentage points broader. The quality of B mode images obtained by the PZN-9%PT probe satisfies the performance of the two types of conventional PZT ceramic probes that have center frequencies of 2.5 and 3.75 MHz. At the reference frequency of 3 MHz, the Doppler sensitivity of the PZN-9%PT probe is about 5 dB higher than that of the 3.75 MHz PZT probe; the blood flow of a pulmonary vein in a hard-to-image patient is much more clearly imaged than in the case of using the PZT probe. These superior images are attributable to the use of sufficiently large PZN-9%PT single crystals obtained by the self-flux method.
- 1 March 1999
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 46 (2) , 414-421
A 3.7 MHz phased array probe using 0.91Pb(Zn/sub 1/3/Nb/sub 2/3/)O/sub 3/-0.09PbTiO/sub 3/
A novel 128-channel phased array probe for echocardiography with a center frequency of 3.7 MHz using 0.91Pb(Zn/sub 1/3/Nb/sub 2/3/)O/sub 3/-0.09PbTiO/sub 3/ (PZN-9%PT) single crystal has been fabricated to realize greater sensitivity and broader bandwidth properties. The echo amplitude of the PZN-9%PT single-crystal probe is about 5 dB higher than that of the conventional lead airconate titanate (PZT) ceramic probe, and the fractional bandwidth is about 25 percentage points broader. The quality of B mode images obtained by the PZN-9%PT probe satisfies the performance of the two types of conventional PZT ceramic probes that have center frequencies of 2.5 and 3.75 MHz. At the reference frequency of 3 MHz, the Doppler sensitivity of the PZN-9%PT probe is about 5 dB higher than that of the 3.75 MHz PZT probe; the blood flow of a pulmonary vein in a hard-to-image patient is much more clearly imaged than in the case of using the PZT probe. These superior images are attributable to the use of sufficiently large PZN-9%PT single crystals obtained by the self-flux method.