Deland Hu Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Deland Hu Liu has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- José del R. Millán
The University of Texas at Austin
5 shared publications - Frigyes Samuel Racz
Department of Neurology, The University of Texas at Austin, Austin, USA
3 shared publications Hussein Alawieh
Chandra Family Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, TX, USA
3 shared publicationsSatyam Kumar
Chandra Family Department of Electrical and Computer Engineering, The University of Texas at Austin, 301 E. Dean Keeton St. C2100, Austin, Texas, 78712-1139, UNITED STATES
2 shared publications- Satyam Kumar
Chandra Family Department of Electrical and Computer Engineering, The University of Texas at Austin, 301 E. Dean Keeton St. C2100, Austin, Texas, 78712-1139, UNITED STATES
2 shared publications - Ashish D. Deshpande
Walker Department of Mechanical Engineering, The University of Texas at Austin, Austin, TX, USA
1 shared publication
Latest Publications
- Open Access
- 15 July 2026
- Published by Wiley in Advanced Science
- Vol. 13 (55) , e76153
Brain‐Computer Interface Training Fosters Perceptual Skills to Detect Errors
Accurate perception of subtle visuo‐motor errors is essential for perceptual and sensorimotor learning, and supports timely corrective actions in precision‐based task. However, conventional perceptual training, typically based on response‐accuracy feedback, is limited in improving sensitivity to small, subtle errors. While prior approaches have focused on modulating sensory regions to enhance perceptual learning, we propose an alternative approach that targets a cognitive neural marker: the error positivity (Pe), a component of the error‐related potential (ErrP) originating in the anterior cingulate cortex, a key decision‐making region. We hypothesize that the Pe, which reflects conscious awareness of errors, serves as a modifiable neural correlate of error perception. In a five‐day longitudinal study, we show that providing real‐time feedback on the presence or absence of ErrPs during perceptual training accelerates perceptual learning at errors and enhances perceptual performance at errors without accelerating the learning rate, relative to behavioral training alone. These behavioral gains were accompanied by increase in Pe amplitude. Together, these findings offer new neurophysiological insights into the mechanisms of error perception, and establish ErrP‐based brain‐computer interface interventions as a promising approach for fostering perceptual learning in domains where detecting subtle errors is critical.
- 15 July 2026
- Published by Wiley in Advanced Science
- Vol. 13 (55) , e76153
Open AccessBrain‐Computer Interface Training Fosters Perceptual Skills to Detect Errors
Accurate perception of subtle visuo‐motor errors is essential for perceptual and sensorimotor learning, and supports timely corrective actions in precision‐based task. However, conventional perceptual training, typically based on response‐accuracy feedback, is limited in improving sensitivity to small, subtle errors. While prior approaches have focused on modulating sensory regions to enhance perceptual learning, we propose an alternative approach that targets a cognitive neural marker: the error positivity (Pe), a component of the error‐related potential (ErrP) originating in the anterior cingulate cortex, a key decision‐making region. We hypothesize that the Pe, which reflects conscious awareness of errors, serves as a modifiable neural correlate of error perception. In a five‐day longitudinal study, we show that providing real‐time feedback on the presence or absence of ErrPs during perceptual training accelerates perceptual learning at errors and enhances perceptual performance at errors without accelerating the learning rate, relative to behavioral training alone. These behavioral gains were accompanied by increase in Pe amplitude. Together, these findings offer new neurophysiological insights into the mechanisms of error perception, and establish ErrP‐based brain‐computer interface interventions as a promising approach for fostering perceptual learning in domains where detecting subtle errors is critical.
- 19 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (1) , 762-769
Characterizing Expectation Mismatch in a Brain-Controlled Upper-Body Rehabilitation Exoskeleton
Robot-assisted therapy has long promised to advance stroke rehabilitation by delivering intensive and personalized training, yet its clinical impact remains limited. Closing the sensorimotor loop with brain–computer interfaces offers a better strategy than passive mobilization, directly linking user intent to robotic assistance and potentially driving neuroplasticity. However, a brain-computer interface requires subject-specific calibration that is time-consuming and often impractical. Moreover, brain decoding remains error-prone due to variability of neural signals, thus resulting in unintended robot actions that could reduce engagement during closed-loop control. Here, we demonstrate that a decoder trained on an expert subject can be transferred to naïve users for online control of a rehabilitation exoskeleton in a rest-versus-reaching paradigm, a functional task with clinical relevance. We then characterize error-related potentials arising from expectation mismatches between brain commands and robot actions during closed-loop control. Finally, we show that these mismatches can be reliably decoded in a subject-independent framework (mean area under the receiver operating characteristic curve: 0.77), a crucial step toward rehabilitation scenarios where collecting subject-specific error-related potential data is challenging. Our findings highlight the potential for integrating real-time error-detection to enhance human–robot interaction by correcting unintended robot behaviors, which could significantly improve rehabilitation outcomes where accurate and contingent feedback is essential.
- 19 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (1) , 762-769
Characterizing Expectation Mismatch in a Brain-Controlled Upper-Body Rehabilitation Exoskeleton
Robot-assisted therapy has long promised to advance stroke rehabilitation by delivering intensive and personalized training, yet its clinical impact remains limited. Closing the sensorimotor loop with brain–computer interfaces offers a better strategy than passive mobilization, directly linking user intent to robotic assistance and potentially driving neuroplasticity. However, a brain-computer interface requires subject-specific calibration that is time-consuming and often impractical. Moreover, brain decoding remains error-prone due to variability of neural signals, thus resulting in unintended robot actions that could reduce engagement during closed-loop control. Here, we demonstrate that a decoder trained on an expert subject can be transferred to naïve users for online control of a rehabilitation exoskeleton in a rest-versus-reaching paradigm, a functional task with clinical relevance. We then characterize error-related potentials arising from expectation mismatches between brain commands and robot actions during closed-loop control. Finally, we show that these mismatches can be reliably decoded in a subject-independent framework (mean area under the receiver operating characteristic curve: 0.77), a crucial step toward rehabilitation scenarios where collecting subject-specific error-related potential data is challenging. Our findings highlight the potential for integrating real-time error-detection to enhance human–robot interaction by correcting unintended robot behaviors, which could significantly improve rehabilitation outcomes where accurate and contingent feedback is essential.
- Open Access
- 1 February 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (1) , 016037
Personalized µ-transcranial alternating current stimulation improves online brain–computer interface control
Objective. A motor imagery (MI)-based brain–computer interface (BCI) enables users to engage with external environments by capturing and decoding electroencephalography (EEG) signals associated with the imagined movement of specific limbs. Despite significant advancements in BCI technologies over the past 40 years, a notable challenge remains: many users lack BCI proficiency, unable to produce sufficiently distinct and reliable MI brain patterns, hence leading to low classification rates in their BCIs. The objective of this study is to enhance the online performance of MI-BCIs in a personalized, biomarker-driven approach using transcranial alternating current stimulation (tACS). Approach. Previous studies have identified that the peak power spectral density value in sensorimotor idling rhythms is a neural correlate of participants’ upper limb MI-BCI performances. In this active-controlled, single-blind study, we applied 20 min of tACS at the participant-specific, peak µ frequency in resting-state sensorimotor rhythms (SMRs), with the goal of enhancing resting-state µ SMRs. Main results. After tACS, we observed significant improvements in event-related desynchronizations (ERDs) of µ SMRs, and in the performance of an online MI-BCI that decodes left versus right hand commands in healthy participants (N = 10)—but not in an active control-stimulation control group (N = 10). Lastly, we showed a significant correlation between the resting-state µ SMRs and µ ERD, offering a mechanistic interpretation behind the observed changes in online BCI performances. Significance. Our research lays the groundwork for future non-invasive interventions designed to enhance BCI performances, thereby improving the independence and interactions of individuals who rely on these systems.
- 1 February 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (1) , 016037
Open AccessPersonalized µ-transcranial alternating current stimulation improves online brain–computer interface control
Objective. A motor imagery (MI)-based brain–computer interface (BCI) enables users to engage with external environments by capturing and decoding electroencephalography (EEG) signals associated with the imagined movement of specific limbs. Despite significant advancements in BCI technologies over the past 40 years, a notable challenge remains: many users lack BCI proficiency, unable to produce sufficiently distinct and reliable MI brain patterns, hence leading to low classification rates in their BCIs. The objective of this study is to enhance the online performance of MI-BCIs in a personalized, biomarker-driven approach using transcranial alternating current stimulation (tACS). Approach. Previous studies have identified that the peak power spectral density value in sensorimotor idling rhythms is a neural correlate of participants’ upper limb MI-BCI performances. In this active-controlled, single-blind study, we applied 20 min of tACS at the participant-specific, peak µ frequency in resting-state sensorimotor rhythms (SMRs), with the goal of enhancing resting-state µ SMRs. Main results. After tACS, we observed significant improvements in event-related desynchronizations (ERDs) of µ SMRs, and in the performance of an online MI-BCI that decodes left versus right hand commands in healthy participants (N = 10)—but not in an active control-stimulation control group (N = 10). Lastly, we showed a significant correlation between the resting-state µ SMRs and µ ERD, offering a mechanistic interpretation behind the observed changes in online BCI performances. Significance. Our research lays the groundwork for future non-invasive interventions designed to enhance BCI performances, thereby improving the independence and interactions of individuals who rely on these systems.
- Open Access
- 13 January 2025
- Published by IOP Publishing in Journal of Neural Engineering
Personalized μ-transcranial alternating current stimulation improves online brain-computer interface control
Objective. A motor imagery (MI)-based brain-computer interface (BCI) enables users to engage with external environments by capturing and decoding electroencephalography (EEG) signals associated with the imagined movement of specific limbs. Despite significant advancements in BCI technologies over the past 40 years, a notable challenge remains: many users lack BCI proficiency, unable to produce sufficiently distinct and reliable MI brain patterns, hence leading to low classification rates in their BCIs. The objective of this study is to enhance the online performance of MI-BCIs in a personalized, biomarker-driven approach using transcranial alternating current stimulation (tACS). Approach. Previous studies have identified that the peak power spectral density (PSD) value in sensorimotor idling rhythms is a neural correlate of participants’ upper limb MI-BCI performances. In this active-controlled, single-blind study, we applied 20 minutes of tACS at the participant-specific, peak µ frequency in resting-state sensorimotor rhythms (SMRs), with the goal of enhancing resting-state µ SMRs. Main Results. After tACS, we observed significant improvements in event-related desynchronizations (ERDs) of µ sensorimotor rhythms (SMRs), and in the performance of an online MI-BCI that decodes left versus right hand commands in healthy participants (N=10) —but not in an active control-stimulation control group (N=10). Lastly, we showed a significant correlation between the resting-state µ SMRs and µ ERD, offering a mechanistic interpretation behind the observed changes in online BCI performances. Significance. Our research lays the groundwork for future non-invasive interventions designed to enhance BCI performances, thereby improving the independence and interactions of individuals who rely on these systems.
- 13 January 2025
- Published by IOP Publishing in Journal of Neural Engineering
Open AccessPersonalized μ-transcranial alternating current stimulation improves online brain-computer interface control
Objective. A motor imagery (MI)-based brain-computer interface (BCI) enables users to engage with external environments by capturing and decoding electroencephalography (EEG) signals associated with the imagined movement of specific limbs. Despite significant advancements in BCI technologies over the past 40 years, a notable challenge remains: many users lack BCI proficiency, unable to produce sufficiently distinct and reliable MI brain patterns, hence leading to low classification rates in their BCIs. The objective of this study is to enhance the online performance of MI-BCIs in a personalized, biomarker-driven approach using transcranial alternating current stimulation (tACS). Approach. Previous studies have identified that the peak power spectral density (PSD) value in sensorimotor idling rhythms is a neural correlate of participants’ upper limb MI-BCI performances. In this active-controlled, single-blind study, we applied 20 minutes of tACS at the participant-specific, peak µ frequency in resting-state sensorimotor rhythms (SMRs), with the goal of enhancing resting-state µ SMRs. Main Results. After tACS, we observed significant improvements in event-related desynchronizations (ERDs) of µ sensorimotor rhythms (SMRs), and in the performance of an online MI-BCI that decodes left versus right hand commands in healthy participants (N=10) —but not in an active control-stimulation control group (N=10). Lastly, we showed a significant correlation between the resting-state µ SMRs and µ ERD, offering a mechanistic interpretation behind the observed changes in online BCI performances. Significance. Our research lays the groundwork for future non-invasive interventions designed to enhance BCI performances, thereby improving the independence and interactions of individuals who rely on these systems.
- Open Access
- 7 January 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (1) , 016002
Novel AIRTrode-based wearable electrode supports long-term, online brain–computer interface operations
Objective. Non-invasive electroencephalograms (EEG)-based brain–computer interfaces (BCIs) play a crucial role in a diverse range of applications, including motor rehabilitation, assistive and communication technologies, holding potential promise to benefit users across various clinical spectrums. Effective integration of these applications into daily life requires systems that provide stable and reliable BCI control for extended periods. Our prior research introduced the AIRTrode, a self-adhesive (A), injectable (I), and room-temperature (RT) spontaneously-crosslinked hydrogel electrode (AIRTrode). The AIRTrode has shown lower skin-contact impedance and greater stability than dry electrodes and, unlike wet gel electrodes, does not dry out after just a few hours, enhancing its suitability for long-term application. This study aims to demonstrate the efficacy of AIRTrodes in facilitating reliable, stable and long-term online EEG-based BCI operations. Approach. In this study, four healthy participants utilized AIRTrodes in two BCI control tasks–continuous and discrete–across two sessions separated by six hours. Throughout this duration, the AIRTrodes remained attached to the participants’ heads. In the continuous task, participants controlled the BCI through decoding of upper-limb motor imagery (MI). In the discrete task, the control was based on decoding of error-related potentials (ErrPs). Main Results. Using AIRTrodes, participants demonstrated consistently reliable online BCI performance across both sessions and tasks. The physiological signals captured during MI and ErrPs tasks were valid and remained stable over sessions. Lastly, both the BCI performances and physiological signals captured were comparable with those from freshly applied, research-grade wet gel electrodes, the latter requiring inconvenient re-application at the start of the second session. Significance. AIRTrodes show great potential promise for integrating non-invasive BCIs into everyday settings due to their ability to support consistent BCI performances over extended periods. This technology could significantly enhance the usability of BCIs in real-world applications, facilitating continuous, all-day functionality that was previously challenging with existing electrode technologies.
- 7 January 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (1) , 016002
Open AccessNovel AIRTrode-based wearable electrode supports long-term, online brain–computer interface operations
Objective. Non-invasive electroencephalograms (EEG)-based brain–computer interfaces (BCIs) play a crucial role in a diverse range of applications, including motor rehabilitation, assistive and communication technologies, holding potential promise to benefit users across various clinical spectrums. Effective integration of these applications into daily life requires systems that provide stable and reliable BCI control for extended periods. Our prior research introduced the AIRTrode, a self-adhesive (A), injectable (I), and room-temperature (RT) spontaneously-crosslinked hydrogel electrode (AIRTrode). The AIRTrode has shown lower skin-contact impedance and greater stability than dry electrodes and, unlike wet gel electrodes, does not dry out after just a few hours, enhancing its suitability for long-term application. This study aims to demonstrate the efficacy of AIRTrodes in facilitating reliable, stable and long-term online EEG-based BCI operations. Approach. In this study, four healthy participants utilized AIRTrodes in two BCI control tasks–continuous and discrete–across two sessions separated by six hours. Throughout this duration, the AIRTrodes remained attached to the participants’ heads. In the continuous task, participants controlled the BCI through decoding of upper-limb motor imagery (MI). In the discrete task, the control was based on decoding of error-related potentials (ErrPs). Main Results. Using AIRTrodes, participants demonstrated consistently reliable online BCI performance across both sessions and tasks. The physiological signals captured during MI and ErrPs tasks were valid and remained stable over sessions. Lastly, both the BCI performances and physiological signals captured were comparable with those from freshly applied, research-grade wet gel electrodes, the latter requiring inconvenient re-application at the start of the second session. Significance. AIRTrodes show great potential promise for integrating non-invasive BCIs into everyday settings due to their ability to support consistent BCI performances over extended periods. This technology could significantly enhance the usability of BCIs in real-world applications, facilitating continuous, all-day functionality that was previously challenging with existing electrode technologies.
- Open Access
- 14 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 168486-168501
Studying the Effects of Compression in EEG-Based Wearable Sleep Monitoring Systems
Long-term sleep monitoring through the use of wearable EEG-based systems generates large volumes of data that need to be either locally stored or wireless transmitted. Compression of data can play a vital role to reduce the power consumption of these already resource-constrained systems. While compression methods can result in significantly reduced data storage and transmission requirements, the loss in signal information can have an impact on the algorithms used to extract the key sleep parameters. This paper studies the impact of six different state-of-the-art compression methods, including wavelet, SPIHT, filter and predictor-based methods, analysing their effects on the reconstructed signal quality particularly for automatic sleep staging applications. It looks at how the overall sleep staging accuracy as well as the detection accuracy of different sleep stages is reduced as a result of different EEG compression methods. It shows that the SPIHT and predictor-based compression methods outperform wavelet and filter-based methods in preserving the relevant signal features. It also shows that compression ratios of up to 65 can be achieved using the QSPIHT method with less than 10% loss in overall sleep staging accuracy.
- 14 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 168486-168501
Open AccessStudying the Effects of Compression in EEG-Based Wearable Sleep Monitoring Systems
Long-term sleep monitoring through the use of wearable EEG-based systems generates large volumes of data that need to be either locally stored or wireless transmitted. Compression of data can play a vital role to reduce the power consumption of these already resource-constrained systems. While compression methods can result in significantly reduced data storage and transmission requirements, the loss in signal information can have an impact on the algorithms used to extract the key sleep parameters. This paper studies the impact of six different state-of-the-art compression methods, including wavelet, SPIHT, filter and predictor-based methods, analysing their effects on the reconstructed signal quality particularly for automatic sleep staging applications. It looks at how the overall sleep staging accuracy as well as the detection accuracy of different sleep stages is reduced as a result of different EEG compression methods. It shows that the SPIHT and predictor-based compression methods outperform wavelet and filter-based methods in preserving the relevant signal features. It also shows that compression ratios of up to 65 can be achieved using the QSPIHT method with less than 10% loss in overall sleep staging accuracy.