U. Anushree
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
U. Anushree has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Sachin Shetty
Department of Nuclear Medicine, Manipal College of Health Professions, Manipal Academy of Higher Education
2 shared publications - Sanjay Bharati
Manipal Academy of Higher Education
2 shared publications - Deepika Pai
Department of Pedodontics & Preventive Dentistry, Manipal College of Dental Sciences, Manipal, India
1 shared publication - Kalyana Chakravarthy Pentapati
Department of Public Health Dentistry, Manipal College of Dental Sciences, Manipal Academy of Higher Education, Manipal, India
1 shared publication - Priyanka Dedhia
Pediatric Dentist, The Smile Suite, Children and Family Dental Care, Mumbai, India
1 shared publication Rajesh Kumar
Nuclear Medicine, All India Institute of Medical Sciences Jodphur, Jodhpur, Rajasthan, INDIA
1 shared publication
Latest Publications
- Open Access
- 9 June 2022
- Published by Hindawi Limited in The Scientific World Journal
- Vol. 2022, 1-8
Analysis of Erosive Nature of Fruit Beverages Fortified with Calcium Ions: An In Vitro Study Evaluating Dental Erosion in Primary Teeth
Background. Since children frequently consume acidic fruit beverages, dental erosion is common in children. The erosive effects on primary teeth are more profound due to the lesser thickness of enamel and dentin. This study evaluated if calcium fortification of fruit beverages could reduce their erosive potential. Methodology. Tropicana Orange Delight was the fruit beverage chosen and fortified with calcium carbonate. Forty noncarious extracted primary teeth were equally distributed into four groups. Samples in group A were exposed to calcium-fortified fruit beverages and group B to nonfortified fruit beverages for 1, 2, and 3min. The pH and calcium ion concentration of both the fruit beverages were evaluated from baseline through the test period. Samples in groups C and D were then exposed to fortified and nonfortified fruit beverages for 10, 20, and 30min. The surface roughness and microhardness of these samples were analysed. Results. Due to fortification, the pH and calcium ion concentration of fortified beverages was higher compared to nonfortified beverages at baseline. The calcium ion concentration of fortified beverages decreased from baseline in contrast to an increase in the nonfortified beverage group. This indicates that fortified beverage is less erosive in nature. The surface roughness of samples in the fortified beverage group did not decrease significantly from baseline. In the nonfortified beverage group, surface roughness values at 20 and 30min of exposure were higher than baseline, suggesting that significant erosive changes occur at the prolonged duration of exposure. The microhardness values of samples in the fortified beverage group increased from baseline through the test period, suggestive of resistance to erosion offered by calcium fortification. The microhardness values of samples in the nonfortified beverage group decreased through the test period, suggestive of erosion. Conclusion. Calcium fortification of this fruit beverage significantly reduces its erosive potential on primary teeth.
- 9 June 2022
- Published by Hindawi Limited in The Scientific World Journal
- Vol. 2022, 1-8
Open AccessAnalysis of Erosive Nature of Fruit Beverages Fortified with Calcium Ions: An In Vitro Study Evaluating Dental Erosion in Primary Teeth
Background. Since children frequently consume acidic fruit beverages, dental erosion is common in children. The erosive effects on primary teeth are more profound due to the lesser thickness of enamel and dentin. This study evaluated if calcium fortification of fruit beverages could reduce their erosive potential. Methodology. Tropicana Orange Delight was the fruit beverage chosen and fortified with calcium carbonate. Forty noncarious extracted primary teeth were equally distributed into four groups. Samples in group A were exposed to calcium-fortified fruit beverages and group B to nonfortified fruit beverages for 1, 2, and 3min. The pH and calcium ion concentration of both the fruit beverages were evaluated from baseline through the test period. Samples in groups C and D were then exposed to fortified and nonfortified fruit beverages for 10, 20, and 30min. The surface roughness and microhardness of these samples were analysed. Results. Due to fortification, the pH and calcium ion concentration of fortified beverages was higher compared to nonfortified beverages at baseline. The calcium ion concentration of fortified beverages decreased from baseline in contrast to an increase in the nonfortified beverage group. This indicates that fortified beverage is less erosive in nature. The surface roughness of samples in the fortified beverage group did not decrease significantly from baseline. In the nonfortified beverage group, surface roughness values at 20 and 30min of exposure were higher than baseline, suggesting that significant erosive changes occur at the prolonged duration of exposure. The microhardness values of samples in the fortified beverage group increased from baseline through the test period, suggestive of resistance to erosion offered by calcium fortification. The microhardness values of samples in the nonfortified beverage group decreased through the test period, suggestive of erosion. Conclusion. Calcium fortification of this fruit beverage significantly reduces its erosive potential on primary teeth.
- 18 February 2022
- Published by Wiley in Bioelectromagnetics
- Vol. 43 (3) , 193-210
Adjunctive Diagnostic Methods for Skin Cancer Detection: A Review of Electrical Impedance‐Based Techniques
Skin cancer is among the fastest‐growing cancers with an excellent prognosis, if detected early. However, the current method of diagnosis by visual inspection has several disadvantages such as overlapping tumor characteristics, subjectivity, low sensitivity, and specificity. Hence, several adjunctive diagnostic techniques such as thermal imaging, optical imaging, ultrasonography, tape stripping methods, and electrical impedance imaging are employed along with visual inspection to improve the diagnosis. Electrical impedance‐based skin cancer detection depends upon the variations in electrical impedance characteristics of the transformed cells. The information provided by this technique is fundamentally different from other adjunctive techniques and thus has good prospects. Depending on the stage, type, and location of skin cancer, various impedance‐based devices have been developed. These devices when used as an adjunct to visual methods have increased the sensitivity and specificity of skin cancer detection up to 100% and 87%, respectively, thus demonstrating their potential to minimize unnecessary biopsies. In this review, the authors track the advancements and progress made in this technique for the detection of skin cancer, focusing mainly on the advantages and limitations in the clinical setting. © 2022 Bioelectromagnetics Society.
- 18 February 2022
- Published by Wiley in Bioelectromagnetics
- Vol. 43 (3) , 193-210
Adjunctive Diagnostic Methods for Skin Cancer Detection: A Review of Electrical Impedance‐Based Techniques
Skin cancer is among the fastest‐growing cancers with an excellent prognosis, if detected early. However, the current method of diagnosis by visual inspection has several disadvantages such as overlapping tumor characteristics, subjectivity, low sensitivity, and specificity. Hence, several adjunctive diagnostic techniques such as thermal imaging, optical imaging, ultrasonography, tape stripping methods, and electrical impedance imaging are employed along with visual inspection to improve the diagnosis. Electrical impedance‐based skin cancer detection depends upon the variations in electrical impedance characteristics of the transformed cells. The information provided by this technique is fundamentally different from other adjunctive techniques and thus has good prospects. Depending on the stage, type, and location of skin cancer, various impedance‐based devices have been developed. These devices when used as an adjunct to visual methods have increased the sensitivity and specificity of skin cancer detection up to 100% and 87%, respectively, thus demonstrating their potential to minimize unnecessary biopsies. In this review, the authors track the advancements and progress made in this technique for the detection of skin cancer, focusing mainly on the advantages and limitations in the clinical setting. © 2022 Bioelectromagnetics Society.
- 7 October 2020
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 6 (6) , 065019
Electrical conductivity spectra of hepatic tumors reflect hepatocellular carcinoma progression in mice
Background: Electrical impedance spectroscopy is a technique which evaluates differences in dielectric properties of tissues for cancer identification. Methods: Murine hepatic cancer model was developed by intraperitoneal administration of N-nitrosodiethylamine to male BALB/c mice. Tumors obtained were evaluated for their conductivity in frequency range of (4 Hz–5 MHz). All tumors were subjected to histopathological grading and parameters such as free spacing, necrosis, and cell density were estimated on histological slides. The status of gap junctions and gap junction intercellular communication (GJIC) were studied using enzyme-linked immunosorbent assay, immunohistochemistry, dye transfer assay, and electron microscopy. Results: Histopathological investigation revealed the presence of moderately to poorly-differentiated hepatocellular carcinoma (HCC) in mice. All types of tumors showed higher electrical conductivity than normal liver tissue in frequency range (4 Hz–1 kHz). However, in frequency range (10 kHz–5 MHz) only poorly-differentiated tumors showed higher conductivity compared to normal tissue. The most prominent findings in moderately-differentiated and poorly-differentiated HCC were increased visible free spaces and necrosis respectively. The status of cell gap junctions were significantly deteriorated in tumors and a corresponding significant reduction in GJIC was also observed. These biological indicators were correlated with electrical conductivity of hepatic tumors. Conclusion: Variations in electrical conductivity spectra of hepatic tumors reflect progression of HCC. General significance: Future studies can be planned to perform hierarchical clustering of dielectric parameters with more number of tumor samples to establish dielectric spectroscopy-based classification or staging of hepatic tumors.
- 7 October 2020
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 6 (6) , 065019
Electrical conductivity spectra of hepatic tumors reflect hepatocellular carcinoma progression in mice
Background: Electrical impedance spectroscopy is a technique which evaluates differences in dielectric properties of tissues for cancer identification. Methods: Murine hepatic cancer model was developed by intraperitoneal administration of N-nitrosodiethylamine to male BALB/c mice. Tumors obtained were evaluated for their conductivity in frequency range of (4 Hz–5 MHz). All tumors were subjected to histopathological grading and parameters such as free spacing, necrosis, and cell density were estimated on histological slides. The status of gap junctions and gap junction intercellular communication (GJIC) were studied using enzyme-linked immunosorbent assay, immunohistochemistry, dye transfer assay, and electron microscopy. Results: Histopathological investigation revealed the presence of moderately to poorly-differentiated hepatocellular carcinoma (HCC) in mice. All types of tumors showed higher electrical conductivity than normal liver tissue in frequency range (4 Hz–1 kHz). However, in frequency range (10 kHz–5 MHz) only poorly-differentiated tumors showed higher conductivity compared to normal tissue. The most prominent findings in moderately-differentiated and poorly-differentiated HCC were increased visible free spaces and necrosis respectively. The status of cell gap junctions were significantly deteriorated in tumors and a corresponding significant reduction in GJIC was also observed. These biological indicators were correlated with electrical conductivity of hepatic tumors. Conclusion: Variations in electrical conductivity spectra of hepatic tumors reflect progression of HCC. General significance: Future studies can be planned to perform hierarchical clustering of dielectric parameters with more number of tumor samples to establish dielectric spectroscopy-based classification or staging of hepatic tumors.