Jerry G. Myers
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jerry G. Myers has a total of 146 co-authors. Here are the top co-authors by number of shared publications:
- Raj Prabhu
NASA Johnson Space Center, Houston, USA
4 shared publications - Rajanikanth Vadigepalli
Thomas Jefferson University
4 shared publications - Erik L. Antonsen
SPEAR Medicine Division, Department of Emergency Medicine, Massachusetts General Hospital, Boston, MA
3 shared publications - Marc Horner
Ansys Inc
3 shared publications Adrienne L. Hoarfrost
Oak Ridge Associated Universities (ORAU), Space Biosciences Division, NASA Ames Research Center, Moffett Field, USA
2 shared publicationsAenor Sawyer
UC Space Health, Department of Orthopaedic Surgery, University of California, San Francisco, San Francisco, USA
2 shared publications
Latest Publications
- Open Access
- 25 June 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (6) , e0313711
A rubric for assessing conformance to the Ten Rules for credible practice of modeling and simulation in healthcare
The power of computational modeling and simulation (M&S) is realized when the results are credible, and the workflow generates evidence that supports credibility for the context of use. The Committee on Credible Practice of Modeling & Simulation in Healthcare was established to help address the need for processes and procedures to support the credible use of M&S in healthcare and biomedical research. Our community efforts have led to the Ten Rules (TR) for Credible Practice of M&S in life sciences and healthcare. This framework is an outcome of a multidisciplinary investigation from a wide range of stakeholders beginning in 2012. Here, we present a pragmatic rubric for assessing the conformance of an M&S activity to the TR. This rubric considers the ability of an M&S study to communicate how well the study conforms to the Ten Rules for credible practice and facilitate outreach to a wide range of stakeholders from context-specific M&S practitioners to policymakers. It uses an ordinal scale ranging from Insufficient (zero) to Comprehensive (four) that is applicable to each rule, providing a uniform approach for comparing assessments across different reviewers and different modeling studies. We used the rubric to evaluate the conformance of two computational modeling activities: 1. six viral disease (COVID-19) propagation models, and 2. a model of hepatic glycogenolysis with neural innervation and calcium signaling. These examples were used to evaluate the applicability of the rubric and illustrate rubric usage in real-world M&S scenarios including those that bridge scientific M&S with policymaking. The COVID-19 M&S studies were of particular interest because they needed to be quickly operationalized by government and private decision-makers early in the COVID-19 pandemic and were accessible as open-source tools. Our findings demonstrate that the TR rubric represents a systematic tool for assessing the conformance of an M&S activity to codified good practices and enhances the value of the TR for supporting real-world decision-making.
- 25 June 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (6) , e0313711
Open AccessA rubric for assessing conformance to the Ten Rules for credible practice of modeling and simulation in healthcare
The power of computational modeling and simulation (M&S) is realized when the results are credible, and the workflow generates evidence that supports credibility for the context of use. The Committee on Credible Practice of Modeling & Simulation in Healthcare was established to help address the need for processes and procedures to support the credible use of M&S in healthcare and biomedical research. Our community efforts have led to the Ten Rules (TR) for Credible Practice of M&S in life sciences and healthcare. This framework is an outcome of a multidisciplinary investigation from a wide range of stakeholders beginning in 2012. Here, we present a pragmatic rubric for assessing the conformance of an M&S activity to the TR. This rubric considers the ability of an M&S study to communicate how well the study conforms to the Ten Rules for credible practice and facilitate outreach to a wide range of stakeholders from context-specific M&S practitioners to policymakers. It uses an ordinal scale ranging from Insufficient (zero) to Comprehensive (four) that is applicable to each rule, providing a uniform approach for comparing assessments across different reviewers and different modeling studies. We used the rubric to evaluate the conformance of two computational modeling activities: 1. six viral disease (COVID-19) propagation models, and 2. a model of hepatic glycogenolysis with neural innervation and calcium signaling. These examples were used to evaluate the applicability of the rubric and illustrate rubric usage in real-world M&S scenarios including those that bridge scientific M&S with policymaking. The COVID-19 M&S studies were of particular interest because they needed to be quickly operationalized by government and private decision-makers early in the COVID-19 pandemic and were accessible as open-source tools. Our findings demonstrate that the TR rubric represents a systematic tool for assessing the conformance of an M&S activity to codified good practices and enhances the value of the TR for supporting real-world decision-making.
- Open Access
From FAIR to CURE: Guidelines for Computational Models of Biological Systems
Guidelines for managing scientific data have been established under the FAIR principles requiring that data be Findable, Accessible, Interoperable, and Reusable. In many scientific disciplines, especially computational biology, both data and models are key to progress. For this reason, and recognizing that such models are a very special type of 'data', we argue that computational models, especially mechanistic models prevalent in medicine, physiology and systems biology, deserve a complementary set of guidelines. We propose the CURE principles, emphasizing that models should be Credible, Understandable, Reproducible, and Extensible. We delve into each principle, discussing verification, validation, and uncertainty quantification for model credibility; the clarity of model descriptions and annotations for understandability; adherence to standards and open science practices for reproducibility; and the use of open standards and modular code for extensibility and reuse. We outline recommended and baseline requirements for each aspect of CURE, aiming to enhance the impact and trustworthiness of computational models, particularly in biomedical applications where credibility is paramount. Our perspective underscores the need for a more disciplined approach to modeling, aligning with emerging trends such as Digital Twins and emphasizing the importance of data and modeling standards for interoperability and reuse. Finally, we emphasize that given the non-trivial effort required to implement the guidelines, the community moves to automate as many of the guidelines as possible.
Open AccessFrom FAIR to CURE: Guidelines for Computational Models of Biological Systems
Guidelines for managing scientific data have been established under the FAIR principles requiring that data be Findable, Accessible, Interoperable, and Reusable. In many scientific disciplines, especially computational biology, both data and models are key to progress. For this reason, and recognizing that such models are a very special type of 'data', we argue that computational models, especially mechanistic models prevalent in medicine, physiology and systems biology, deserve a complementary set of guidelines. We propose the CURE principles, emphasizing that models should be Credible, Understandable, Reproducible, and Extensible. We delve into each principle, discussing verification, validation, and uncertainty quantification for model credibility; the clarity of model descriptions and annotations for understandability; adherence to standards and open science practices for reproducibility; and the use of open standards and modular code for extensibility and reuse. We outline recommended and baseline requirements for each aspect of CURE, aiming to enhance the impact and trustworthiness of computational models, particularly in biomedical applications where credibility is paramount. Our perspective underscores the need for a more disciplined approach to modeling, aligning with emerging trends such as Digital Twins and emphasizing the importance of data and modeling standards for interoperability and reuse. Finally, we emphasize that given the non-trivial effort required to implement the guidelines, the community moves to automate as many of the guidelines as possible.
- Open Access
- 23 December 2024
- Published by Wiley in Journal of Engineering and Science in Medical Diagnostics and Therapy
- Vol. 8 (4) , 1-14
Modeling and Simulation Credibility Assessments of Musculoskeletal Computational Models for Simulating Astronaut Injuries Due to a Poor Spacesuit Fit
The musculoskeletal (MS) system of astronauts is subject to physiological changes, potentially leading to injuries due to the exposure to different gravitational environments experienced during spaceflight. These injuries can occur while an astronaut is performing an extravehicular activity (EVA) in space, on lunar or planetary surfaces or while wearing a spacesuit during terrestrial training for an EVA. The opensim MS modeling software can assess EVA induced MS injury mechanisms such as muscle strains, ligament injuries, and joint injuries. One area of concern, since there are only a few different spacesuit sizes with limited adjustability, is the possibility of a poorly fitting spacesuit. This can cause unnatural joint motions and torques resulting in various MS injuries. A credibility assessment of the opensim modeling and simulation procedures is performed per NASA-STD-7009A to provide information on the credibility of the model's use in simulating EVA related injury mechanisms. The credibility assessment evaluated various opensim models against the following eight credibility factors: data pedigree, input pedigree, code verification, solution verification, conceptual validation, referent validation, results uncertainty, and results robustness (sensitivity). The models evaluated for EVA injuries will require additional credibility factor analysis and upgrades to the model features, such as adding ligaments to a whole-body model, to reliably predict and analyze the EVA injuries expected to occur due to a poor spacesuit fit. The degree of elevation strategy required to increase the credibility assessment scores will depend on the model complexity and the injury mechanism.
- 23 December 2024
- Published by Wiley in Journal of Engineering and Science in Medical Diagnostics and Therapy
- Vol. 8 (4) , 1-14
Open AccessModeling and Simulation Credibility Assessments of Musculoskeletal Computational Models for Simulating Astronaut Injuries Due to a Poor Spacesuit Fit
The musculoskeletal (MS) system of astronauts is subject to physiological changes, potentially leading to injuries due to the exposure to different gravitational environments experienced during spaceflight. These injuries can occur while an astronaut is performing an extravehicular activity (EVA) in space, on lunar or planetary surfaces or while wearing a spacesuit during terrestrial training for an EVA. The opensim MS modeling software can assess EVA induced MS injury mechanisms such as muscle strains, ligament injuries, and joint injuries. One area of concern, since there are only a few different spacesuit sizes with limited adjustability, is the possibility of a poorly fitting spacesuit. This can cause unnatural joint motions and torques resulting in various MS injuries. A credibility assessment of the opensim modeling and simulation procedures is performed per NASA-STD-7009A to provide information on the credibility of the model's use in simulating EVA related injury mechanisms. The credibility assessment evaluated various opensim models against the following eight credibility factors: data pedigree, input pedigree, code verification, solution verification, conceptual validation, referent validation, results uncertainty, and results robustness (sensitivity). The models evaluated for EVA injuries will require additional credibility factor analysis and upgrades to the model features, such as adding ligaments to a whole-body model, to reliably predict and analyze the EVA injuries expected to occur due to a poor spacesuit fit. The degree of elevation strategy required to increase the credibility assessment scores will depend on the model complexity and the injury mechanism.
- Open Access
A rubric for assessing conformance to the Ten Rules for credible practice of modeling and simulation in healthcare
The power of computational modeling and simulation (M&S) is realized when the results are credible, and the workflow generates evidence that supports credibility for the context of use. The Committee on Credible Practice of Modeling & Simulation in Healthcare was established to help address the need for processes and procedures to support the credible use of M&S in healthcare and biomedical research. Our community efforts have led to the Ten Rules (TR) for Credible Practice of M&S in life sciences and healthcare. This framework is an outcome of a multidisciplinary investigation from a wide range of stakeholders beginning in 2012. Here, we present a pragmatic rubric for assessing the conformance of an M&S activity to the TR. This rubric considers the ability of the M&S to facilitate outreach of the results to a wide range of stakeholders from context-specific M&S practitioners to policymakers. It uses an ordinal scale ranging from Insufficient (zero) to Comprehensive (four) that is applicable to each rule, providing a uniform approach for comparing assessments across different reviewers and different models. We used the rubric to evaluate the conformance of two computational modeling activities: 1. six viral disease (COVID-19) propagation models, and 2. a model of hepatic glycogenolysis with neural innervation and calcium signaling. These examples were used to evaluate the applicability of the rubric and illustrate rubric usage in real-world M&S scenarios including those that bridge scientific M&S with policymaking. The COVID-19 M&S studies were of particular interest because they needed to be quickly operationalized by government and private decision-makers early in the COVID-19 pandemic and were accessible as open-source tools. Our findings demonstrate that the TR rubric represents a systematic tool for assessing the conformance of an M&S activity to codified good practices and enhances the value of the TR for supporting real-world decision-making.
Open AccessA rubric for assessing conformance to the Ten Rules for credible practice of modeling and simulation in healthcare
The power of computational modeling and simulation (M&S) is realized when the results are credible, and the workflow generates evidence that supports credibility for the context of use. The Committee on Credible Practice of Modeling & Simulation in Healthcare was established to help address the need for processes and procedures to support the credible use of M&S in healthcare and biomedical research. Our community efforts have led to the Ten Rules (TR) for Credible Practice of M&S in life sciences and healthcare. This framework is an outcome of a multidisciplinary investigation from a wide range of stakeholders beginning in 2012. Here, we present a pragmatic rubric for assessing the conformance of an M&S activity to the TR. This rubric considers the ability of the M&S to facilitate outreach of the results to a wide range of stakeholders from context-specific M&S practitioners to policymakers. It uses an ordinal scale ranging from Insufficient (zero) to Comprehensive (four) that is applicable to each rule, providing a uniform approach for comparing assessments across different reviewers and different models. We used the rubric to evaluate the conformance of two computational modeling activities: 1. six viral disease (COVID-19) propagation models, and 2. a model of hepatic glycogenolysis with neural innervation and calcium signaling. These examples were used to evaluate the applicability of the rubric and illustrate rubric usage in real-world M&S scenarios including those that bridge scientific M&S with policymaking. The COVID-19 M&S studies were of particular interest because they needed to be quickly operationalized by government and private decision-makers early in the COVID-19 pandemic and were accessible as open-source tools. Our findings demonstrate that the TR rubric represents a systematic tool for assessing the conformance of an M&S activity to codified good practices and enhances the value of the TR for supporting real-world decision-making.
- Open Access
- 10 April 2024
- Published by Springer Nature in npj Microgravity
- Vol. 10 (1) , 1-10
Modeling the impact of thoracic pressure on intracranial pressure
A potential contribution to the progression of Spaceflight Associated Neuro-ocular Syndrome is the thoracic-to-spinal dural sac transmural pressure relationship. In this study, we utilize a lumped-parameter computational model of human cerebrospinal fluid (CSF) systems to investigate mechanisms of CSF redistribution. We present two analyses to illustrate potential mechanisms for CSF pressure alterations similar to those observed in microgravity conditions. Our numerical evidence suggests that the compliant relationship between thoracic and CSF compartments is insufficient to solely explain the observed decrease in CSF pressure with respect to the supine position. Our analyses suggest that the interaction between thoracic pressure and the cardiovascular system, particularly the central veins, has greater influence on CSF pressure. These results indicate that future studies should focus on the holistic system, with the impact of cardiovascular changes to the CSF pressure emphasized over the sequestration of fluid in the spine.
- 10 April 2024
- Published by Springer Nature in npj Microgravity
- Vol. 10 (1) , 1-10
Open AccessModeling the impact of thoracic pressure on intracranial pressure
A potential contribution to the progression of Spaceflight Associated Neuro-ocular Syndrome is the thoracic-to-spinal dural sac transmural pressure relationship. In this study, we utilize a lumped-parameter computational model of human cerebrospinal fluid (CSF) systems to investigate mechanisms of CSF redistribution. We present two analyses to illustrate potential mechanisms for CSF pressure alterations similar to those observed in microgravity conditions. Our numerical evidence suggests that the compliant relationship between thoracic and CSF compartments is insufficient to solely explain the observed decrease in CSF pressure with respect to the supine position. Our analyses suggest that the interaction between thoracic pressure and the cardiovascular system, particularly the central veins, has greater influence on CSF pressure. These results indicate that future studies should focus on the holistic system, with the impact of cardiovascular changes to the CSF pressure emphasized over the sequestration of fluid in the spine.
- 23 March 2023
- Published by Springer Nature in Nature Machine Intelligence
- Vol. 5 (3) , 196-207
Biomonitoring and precision health in deep space supported by artificial intelligence
- 23 March 2023
- Published by Springer Nature in Nature Machine Intelligence
- Vol. 5 (3) , 196-207
Biomonitoring and precision health in deep space supported by artificial intelligence
- 23 March 2023
- Published by Springer Nature in Nature Machine Intelligence
- Vol. 5 (3) , 208-219
Biological research and self-driving labs in deep space supported by artificial intelligence
- 23 March 2023
- Published by Springer Nature in Nature Machine Intelligence
- Vol. 5 (3) , 208-219
Biological research and self-driving labs in deep space supported by artificial intelligence
- Open Access
- 31 March 2022
- Published by Springer Nature in npj Microgravity
- Vol. 8 (1) , 1-10
Estimating medical risk in human spaceflight
NASA and commercial spaceflight companies will soon be retuning humans to the Moon and then eventually sending them on to Mars. These distant planetary destinations will pose new risks—in particular for the health of the astronaut crews. The bulk of the evidence characterizing human health and performance in spaceflight has come from missions in Low Earth Orbit. As missions last longer and travel farther from Earth, medical risk is expected to contribute an increasing proportion of total mission risk. To date, there have been no reliable estimates of how much. The Integrated Medical Model (IMM) is a Probabilistic Risk Assessment (PRA) Monte-Carlo simulation tool developed by NASA for medical risk assessment. This paper uses the IMM to provide an evidence-based, quantified medical risk estimate comparison across different spaceflight mission durations. We discuss model limitations and unimplemented capabilities providing insight into the complexity of medical risk estimation for human spaceflight. The results enable prioritization of medical needs in the context of other mission risks. These findings provide a reasonable bounding estimate for medical risk in missions to the Moon and Mars and hold value for risk managers and mission planners in performing cost-benefit trades for mission capability and research investments.
- 31 March 2022
- Published by Springer Nature in npj Microgravity
- Vol. 8 (1) , 1-10
Open AccessEstimating medical risk in human spaceflight
NASA and commercial spaceflight companies will soon be retuning humans to the Moon and then eventually sending them on to Mars. These distant planetary destinations will pose new risks—in particular for the health of the astronaut crews. The bulk of the evidence characterizing human health and performance in spaceflight has come from missions in Low Earth Orbit. As missions last longer and travel farther from Earth, medical risk is expected to contribute an increasing proportion of total mission risk. To date, there have been no reliable estimates of how much. The Integrated Medical Model (IMM) is a Probabilistic Risk Assessment (PRA) Monte-Carlo simulation tool developed by NASA for medical risk assessment. This paper uses the IMM to provide an evidence-based, quantified medical risk estimate comparison across different spaceflight mission durations. We discuss model limitations and unimplemented capabilities providing insight into the complexity of medical risk estimation for human spaceflight. The results enable prioritization of medical needs in the context of other mission risks. These findings provide a reasonable bounding estimate for medical risk in missions to the Moon and Mars and hold value for risk managers and mission planners in performing cost-benefit trades for mission capability and research investments.
- Open Access
- 28 January 2022
- Published by Springer Nature in npj Microgravity
- Vol. 8 (1) , 1-17
Numerical characterization of astronaut CaOx renal stone incidence rates to quantify in-flight and post-flight relative risk
Changes in urine chemistry potentially alter the risk of renal stone formation in astronauts. Quantifying spaceflight renal stone incidence risk compared to pre-flight levels remains a significant challenge for assessing the appropriate vehicle, mission, and countermeasure design. A computational biochemistry model representing CaOx crystal precipitation, growth, and agglomeration is combined with a probabilistic analysis to predict the in- and post-flight CaOx renal stone incidence risk ratio (IRR) relative to pre-flight values using 1517 astronaut 24-h urine chemistries. Our simulations predict that in-flight fluid intake alone would need to increase from current prescriptions of 2.0–2.5 L/day to ~3.2 L/day to approach the CaOx IRR of the pre-flight population. Bone protective interventions would reduce CaOx risk to pre-flight levels if Ca excretion alone is reduced to <150 mg/day or if current levels are diminished to 190 mg/day in combination with increasing fluid intake to 2.5–2.7 L/day. This analysis provides a quantitative risk assessment that can influence the critical balance between engineering and astronaut health requirements.
- 28 January 2022
- Published by Springer Nature in npj Microgravity
- Vol. 8 (1) , 1-17
Open AccessNumerical characterization of astronaut CaOx renal stone incidence rates to quantify in-flight and post-flight relative risk
Changes in urine chemistry potentially alter the risk of renal stone formation in astronauts. Quantifying spaceflight renal stone incidence risk compared to pre-flight levels remains a significant challenge for assessing the appropriate vehicle, mission, and countermeasure design. A computational biochemistry model representing CaOx crystal precipitation, growth, and agglomeration is combined with a probabilistic analysis to predict the in- and post-flight CaOx renal stone incidence risk ratio (IRR) relative to pre-flight values using 1517 astronaut 24-h urine chemistries. Our simulations predict that in-flight fluid intake alone would need to increase from current prescriptions of 2.0–2.5 L/day to ~3.2 L/day to approach the CaOx IRR of the pre-flight population. Bone protective interventions would reduce CaOx risk to pre-flight levels if Ca excretion alone is reduced to <150 mg/day or if current levels are diminished to 190 mg/day in combination with increasing fluid intake to 2.5–2.7 L/day. This analysis provides a quantitative risk assessment that can influence the critical balance between engineering and astronaut health requirements.
- Top Cited PapersOpen Access
- 29 September 2020
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 18 (1) , 1-18
Credible practice of modeling and simulation in healthcare: ten rules from a multidisciplinary perspective
The complexities of modern biomedicine are rapidly increasing. Thus, modeling and simulation have become increasingly important as a strategy to understand and predict the trajectory of pathophysiology, disease genesis, and disease spread in support of clinical and policy decisions. In such cases, inappropriate or ill-placed trust in the model and simulation outcomes may result in negative outcomes, and hence illustrate the need to formalize the execution and communication of modeling and simulation practices. Although verification and validation have been generally accepted as significant components of a model’s credibility, they cannot be assumed to equate to a holistic credible practice, which includes activities that can impact comprehension and in-depth examination inherent in the development and reuse of the models. For the past several years, the Committee on Credible Practice of Modeling and Simulation in Healthcare, an interdisciplinary group seeded from a U.S. interagency initiative, has worked to codify best practices. Here, we provide Ten Rules for credible practice of modeling and simulation in healthcare developed from a comparative analysis by the Committee’s multidisciplinary membership, followed by a large stakeholder community survey. These rules establish a unified conceptual framework for modeling and simulation design, implementation, evaluation, dissemination and usage across the modeling and simulation life-cycle. While biomedical science and clinical care domains have somewhat different requirements and expectations for credible practice, our study converged on rules that would be useful across a broad swath of model types. In brief, the rules are: (1) Define context clearly. (2) Use contextually appropriate data. (3) Evaluate within context. (4) List limitations explicitly. (5) Use version control. (6) Document appropriately. (7) Disseminate broadly. (8) Get independent reviews. (9) Test competing implementations. (10) Conform to standards. Although some of these are common sense guidelines, we have found that many are often missed or misconstrued, even by seasoned practitioners. Computational models are already widely used in basic science to generate new biomedical knowledge. As they penetrate clinical care and healthcare policy, contributing to personalized and precision medicine, clinical safety will require established guidelines for the credible practice of modeling and simulation in healthcare.
- 29 September 2020
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 18 (1) , 1-18
Top Cited PapersOpen AccessCredible practice of modeling and simulation in healthcare: ten rules from a multidisciplinary perspective
The complexities of modern biomedicine are rapidly increasing. Thus, modeling and simulation have become increasingly important as a strategy to understand and predict the trajectory of pathophysiology, disease genesis, and disease spread in support of clinical and policy decisions. In such cases, inappropriate or ill-placed trust in the model and simulation outcomes may result in negative outcomes, and hence illustrate the need to formalize the execution and communication of modeling and simulation practices. Although verification and validation have been generally accepted as significant components of a model’s credibility, they cannot be assumed to equate to a holistic credible practice, which includes activities that can impact comprehension and in-depth examination inherent in the development and reuse of the models. For the past several years, the Committee on Credible Practice of Modeling and Simulation in Healthcare, an interdisciplinary group seeded from a U.S. interagency initiative, has worked to codify best practices. Here, we provide Ten Rules for credible practice of modeling and simulation in healthcare developed from a comparative analysis by the Committee’s multidisciplinary membership, followed by a large stakeholder community survey. These rules establish a unified conceptual framework for modeling and simulation design, implementation, evaluation, dissemination and usage across the modeling and simulation life-cycle. While biomedical science and clinical care domains have somewhat different requirements and expectations for credible practice, our study converged on rules that would be useful across a broad swath of model types. In brief, the rules are: (1) Define context clearly. (2) Use contextually appropriate data. (3) Evaluate within context. (4) List limitations explicitly. (5) Use version control. (6) Document appropriately. (7) Disseminate broadly. (8) Get independent reviews. (9) Test competing implementations. (10) Conform to standards. Although some of these are common sense guidelines, we have found that many are often missed or misconstrued, even by seasoned practitioners. Computational models are already widely used in basic science to generate new biomedical knowledge. As they penetrate clinical care and healthcare policy, contributing to personalized and precision medicine, clinical safety will require established guidelines for the credible practice of modeling and simulation in healthcare.