Sopio Melikishvili
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Sopio Melikishvili has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Tibor Hianik
Faculty of Mathematics, Physics and Informatics, Comenius University, Mlynska dolina F1, 842 48 Bratislava, Slovakia
4 shared publications - Michael Thompson
Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, ON M5S 3H6, Canada
2 shared publications Andreas K.O. Åslund
Department of Physics, The Norwegian University of Science and Technology (NTNU), 7491 Trondheim, Norway
1 shared publicationCatharina de Lange Davies
Department of Physics, The Norwegian University of Science and Technology (NTNU), 7491 Trondheim, Norway
1 shared publicationEinar Sulheim
Department of Physics, The Norwegian University of Science and Technology (NTNU), 7491 Trondheim, Norway; SINTEF Materials and Chemistry, 7465 Trondheim, Norway
1 shared publicationGennady Evtugyn
Analytical Chemistry Department, Chemistry Institute of Kazan Federal University, Kazan, Russian Federation
1 shared publication
Latest Publications
- Open Access
- 2 October 2021
- Published by MDPI AG in Chemosensors
- Vol. 9 (10) , 281
Advances in Colorimetric Assay Based on AuNPs Modified by Proteins and Nucleic Acid Aptamers
This review is focused on the biosensing assay based on AuNPs (AuNPs) modified by proteins, peptides and nucleic acid aptamers. The unique physical properties of AuNPs allow their modification by proteins, peptides or nucleic acid aptamers by chemisorption as well as other methods including physical adsorption and covalent immobilization using carbodiimide chemistry or based on strong binding of biotinylated receptors on neutravidin, streptavidin or avidin. The methods of AuNPs preparation, their chemical modification and application in several biosensing assays are presented with focus on application of nucleic acid aptamers for colorimetry assay for determination of antibiotics and bacteria in food samples.
- 2 October 2021
- Published by MDPI AG in Chemosensors
- Vol. 9 (10) , 281
Open AccessAdvances in Colorimetric Assay Based on AuNPs Modified by Proteins and Nucleic Acid Aptamers
This review is focused on the biosensing assay based on AuNPs (AuNPs) modified by proteins, peptides and nucleic acid aptamers. The unique physical properties of AuNPs allow their modification by proteins, peptides or nucleic acid aptamers by chemisorption as well as other methods including physical adsorption and covalent immobilization using carbodiimide chemistry or based on strong binding of biotinylated receptors on neutravidin, streptavidin or avidin. The methods of AuNPs preparation, their chemical modification and application in several biosensing assays are presented with focus on application of nucleic acid aptamers for colorimetry assay for determination of antibiotics and bacteria in food samples.
- Open Access
- 11 April 2021
- Published by MDPI AG in Biosensors
- Vol. 11 (4) , 117
Detection of Sub-Nanomolar Concentration of Trypsin by Thickness-Shear Mode Acoustic Biosensor and Spectrophotometry
The determination of protease activity is very important for disease diagnosis, drug development, and quality and safety assurance for dairy products. Therefore, the development of low-cost and sensitive methods for assessing protease activity is crucial. We report two approaches for monitoring protease activity: in a volume and at surface, via colorimetric and acoustic wave-based biosensors operated in the thickness-shear mode (TSM), respectively. The TSM sensor was based on a β-casein substrate immobilized on a piezoelectric quartz crystal transducer. After an enzymatic reaction with trypsin, it cleaved the surface-bound β-casein, which increased the resonant frequency of the crystal. The limit of detection (LOD) was 0.48 ± 0.08 nM. A label-free colorimetric assay for trypsin detection has also been performed using β-casein and 6-mercaptohexanol (MCH) functionalized gold nanoparticles (AuNPs/MCH-β-casein). Due to the trypsin cleavage of β-casein, the gold nanoparticles lost shelter, and MCH increased the attractive force between the modified AuNPs. Consequently, AuNPs aggregated, and the red shift of the absorption spectra was observed. Spectrophotometric assay enabled an LOD of 0.42 ± 0.03 nM. The Michaelis–Menten constant, KM, for reverse enzyme reaction has also been estimated by both methods. This value for the colorimetric assay (0.56 ± 0.10 nM) is lower in comparison with those for the TSM sensor (0.92 ± 0.44 nM). This is likely due to the better access of the trypsin to the β-casein substrate at the surface of AuNPs in comparison with those at the TSM transducer.
- 11 April 2021
- Published by MDPI AG in Biosensors
- Vol. 11 (4) , 117
Open AccessDetection of Sub-Nanomolar Concentration of Trypsin by Thickness-Shear Mode Acoustic Biosensor and Spectrophotometry
The determination of protease activity is very important for disease diagnosis, drug development, and quality and safety assurance for dairy products. Therefore, the development of low-cost and sensitive methods for assessing protease activity is crucial. We report two approaches for monitoring protease activity: in a volume and at surface, via colorimetric and acoustic wave-based biosensors operated in the thickness-shear mode (TSM), respectively. The TSM sensor was based on a β-casein substrate immobilized on a piezoelectric quartz crystal transducer. After an enzymatic reaction with trypsin, it cleaved the surface-bound β-casein, which increased the resonant frequency of the crystal. The limit of detection (LOD) was 0.48 ± 0.08 nM. A label-free colorimetric assay for trypsin detection has also been performed using β-casein and 6-mercaptohexanol (MCH) functionalized gold nanoparticles (AuNPs/MCH-β-casein). Due to the trypsin cleavage of β-casein, the gold nanoparticles lost shelter, and MCH increased the attractive force between the modified AuNPs. Consequently, AuNPs aggregated, and the red shift of the absorption spectra was observed. Spectrophotometric assay enabled an LOD of 0.42 ± 0.03 nM. The Michaelis–Menten constant, KM, for reverse enzyme reaction has also been estimated by both methods. This value for the colorimetric assay (0.56 ± 0.10 nM) is lower in comparison with those for the TSM sensor (0.92 ± 0.44 nM). This is likely due to the better access of the trypsin to the β-casein substrate at the surface of AuNPs in comparison with those at the TSM transducer.
- Open Access
- 2 November 2020
- Published by MDPI AG in Proceedings
- Vol. 60 (1) , 6
Detection of Sub-Nanomolar Concentration of Trypsin by Thicken-Shear Mode (TSM) Acoustic Wave Biosensor
The determination of protease activity is very important for disease diagnosis, drug development, and quality and safety assurance for dairy products. Therefore, the development of low-cost methods for assessing protease activity is critical. Here, we demonstrate that an acoustic wave-based biosensor operated in the thickness-shear mode (TSM) enables the low-cost detection of protease activity in real time. The TSM sensor was based on a protein substrate (PS) β-casein immobilized on a piezoelectric quartz crystal electrode. The β-casein layer was immobilized onto a gold surface by a carboxylate terminated self-assembled monolayer (SAM) of 11-mercaptoundecanoic acid (MUA). The carboxylic acid terminal was activated by the reaction of a mixture of water- soluble N-(3-Dimethylaminopropyl)-N0-ethylcarbodiimide (EDC) and N–Hydroxysuccinimide (NHS) on the electrode surfaces. We demonstrated that β-casein can form a stable assembly on a piezoelectric quartz crystal electrode. After an enzymatic reaction with trypsin, it cleaved the surface-bound β-casein substrate, which increased the frequency of the crystal in a sigmoidal manner. Trypsin was detected in the range of concentrations from 1 to 50 nM. The limit of detection was 0.2 nM. Initial reaction rates measured at different enzyme concentrations have been used to construct a calibration curve. Considering the results obtained, we believe that the TSM biosensor is a useful tool for protease analysis.
- 2 November 2020
- Published by MDPI AG in Proceedings
- Vol. 60 (1) , 6
Open AccessDetection of Sub-Nanomolar Concentration of Trypsin by Thicken-Shear Mode (TSM) Acoustic Wave Biosensor
The determination of protease activity is very important for disease diagnosis, drug development, and quality and safety assurance for dairy products. Therefore, the development of low-cost methods for assessing protease activity is critical. Here, we demonstrate that an acoustic wave-based biosensor operated in the thickness-shear mode (TSM) enables the low-cost detection of protease activity in real time. The TSM sensor was based on a protein substrate (PS) β-casein immobilized on a piezoelectric quartz crystal electrode. The β-casein layer was immobilized onto a gold surface by a carboxylate terminated self-assembled monolayer (SAM) of 11-mercaptoundecanoic acid (MUA). The carboxylic acid terminal was activated by the reaction of a mixture of water- soluble N-(3-Dimethylaminopropyl)-N0-ethylcarbodiimide (EDC) and N–Hydroxysuccinimide (NHS) on the electrode surfaces. We demonstrated that β-casein can form a stable assembly on a piezoelectric quartz crystal electrode. After an enzymatic reaction with trypsin, it cleaved the surface-bound β-casein substrate, which increased the frequency of the crystal in a sigmoidal manner. Trypsin was detected in the range of concentrations from 1 to 50 nM. The limit of detection was 0.2 nM. Initial reaction rates measured at different enzyme concentrations have been used to construct a calibration curve. Considering the results obtained, we believe that the TSM biosensor is a useful tool for protease analysis.
- 1 January 2018
- Published by Elsevier
- Vol. 85, 263-310
Affinity Biosensors for Detection of Mycotoxins in Food
- 1 January 2018
- Published by Elsevier
- Vol. 85, 263-310
Affinity Biosensors for Detection of Mycotoxins in Food
- 1 February 2017
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 150, 373-383
The effect of poly(ethylene glycol) coating and monomer type on poly(alkyl cyanoacrylate) nanoparticle interactions with lipid monolayers and cells
- 1 February 2017
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 150, 373-383
The effect of poly(ethylene glycol) coating and monomer type on poly(alkyl cyanoacrylate) nanoparticle interactions with lipid monolayers and cells