Bruce D. Johnson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Bruce D. Johnson has a total of 221 co-authors. Here are the top co-authors by number of shared publications:
Kenneth C. Beck
Division of Cardiovascular Diseases, Mayo Clinic, Rochester, Minnesota
11 shared publicationsThomas P. Olson
Department of Internal Medicine, Mayo Clinic, Rochester, MN
11 shared publications- Bryan Joseph Taylor
School of Biomedical Sciences, University of Leeds, Leeds, LS2 9JT, UK
9 shared publications - Lyle J. Olson
Division of Cardiovascular Diseases, Mayo Clinic, Rochester, MN
9 shared publications Lyle J. Olson
Department of Cardiovascular Diseases, Mayo Clinic, Rochester, Minnesota
8 shared publications- Courtney M. Wheatley
Mayo Clinic, Scottsdale, AZ
6 shared publications
Latest Publications
- Open Access
- 18 April 2024
- Published by Oxford University Press (OUP) in ESC Heart Failure
- Vol. 11 (4) , 2421-2425
Blunted Cardiovascular Responses to Exercise by Inhibiting Afferent Feedback via Spinal Cord Stimulation in Heart Failure
This case study investigated the impact of SCS on alterations in blood pressure during constant-load exercise in a female patient with heart failure. Three different SCS frequencies [No SCS (~0 Hz), Low SCS (~100 Hz), and High SCS (~1000 Hz)] with and without ischaemic stimulation of the legs (cuffs) were randomly applied during constant-load exercise. To determine cardiovascular and ventilatory responses to exercise following SCS frequencies, BP, heart rate (HR), and respiratory gas exchange were measured. This experiment was duplicated in visit 1 and visit 2 with a random application of SCS frequency order and the data were averaged. There were no significant differences among three frequencies with no leg ischaemia. However, High SCS demonstrated lower BP, HR, and respiratory gas exchange relative to No SCS and Low SCS. SCS may be effective in improving cardiovascular and ventilatory responses in HF and high-frequency stimulation provides more clinical benefit; however, further studies are needed.
- 18 April 2024
- Published by Oxford University Press (OUP) in ESC Heart Failure
- Vol. 11 (4) , 2421-2425
Open AccessBlunted Cardiovascular Responses to Exercise by Inhibiting Afferent Feedback via Spinal Cord Stimulation in Heart Failure
This case study investigated the impact of SCS on alterations in blood pressure during constant-load exercise in a female patient with heart failure. Three different SCS frequencies [No SCS (~0 Hz), Low SCS (~100 Hz), and High SCS (~1000 Hz)] with and without ischaemic stimulation of the legs (cuffs) were randomly applied during constant-load exercise. To determine cardiovascular and ventilatory responses to exercise following SCS frequencies, BP, heart rate (HR), and respiratory gas exchange were measured. This experiment was duplicated in visit 1 and visit 2 with a random application of SCS frequency order and the data were averaged. There were no significant differences among three frequencies with no leg ischaemia. However, High SCS demonstrated lower BP, HR, and respiratory gas exchange relative to No SCS and Low SCS. SCS may be effective in improving cardiovascular and ventilatory responses in HF and high-frequency stimulation provides more clinical benefit; however, further studies are needed.
- 12 October 2023
- Published by S. Karger AG in Cardiology
- Vol. 149 (2) , 183-188
Feasibility of Noninvasive Assessment of Cardiac Output during Exercise in Healthy Adults by a Novel Elaboration on Systolic Time Intervals
Background: Although assessment of cardiovascular hemodynamics during exercise can provide clinical insights, it is challenging to acquire it in clinical settings. Objectives: Accordingly, this preliminary study was to determine whether a novel elaboration on systolic time interval measures (eSTICO) method of quantifying cardiac output and stroke volume was comparable to those obtained using a validated soluble gas (open circuit CO measure [OpCircCO]) method or calculation based on oxygen consumption (oxygen consumption-based CO [VO2CO]) during exercise. Methods: For the present study, 14 healthy subjects (male: n = 12, female: n = 2) performed incremental exercise on a recumbent cycle ergometer. At rest and during exercise, cardiac output (CO) was obtained via the eSTICO method, while the OpenCircCO and VO2CO measures were obtained at the last minute of each workload. Results: At peak, there was no difference between eSTICO and OpCircCO (12.39 ± 3.06 vs. 13.96 ± 2.47 L/min, p > 0.05), while there was a slight difference between eSTICO and VO2CO (12.39 ± 3.06 vs. 14.28 ± 2.55 L/min, p < 0.05). When we performed correlation analysis with all subjects and all measures of CO at all WL, between eSTICO and OpenCircCO, there was a good relationship (r = 0.707, p < 0.001) with a Bland and Altman agreement analysis demonstrating a −1.6 difference (95% LoA: −6.3–3.5). Between eSTICO and VO2CO, we observed an r = 0.865 (p < 0.001) and a Bland and Altman agreement analysis with a −1.2 difference (95% LoA: −4.8–2.4). Conclusion: A novel exploitation of cardiac hemodynamics using systolic timing intervals may allow a relatively good assessment of CO during exercise in healthy adults.
- 12 October 2023
- Published by S. Karger AG in Cardiology
- Vol. 149 (2) , 183-188
Feasibility of Noninvasive Assessment of Cardiac Output during Exercise in Healthy Adults by a Novel Elaboration on Systolic Time Intervals
Background: Although assessment of cardiovascular hemodynamics during exercise can provide clinical insights, it is challenging to acquire it in clinical settings. Objectives: Accordingly, this preliminary study was to determine whether a novel elaboration on systolic time interval measures (eSTICO) method of quantifying cardiac output and stroke volume was comparable to those obtained using a validated soluble gas (open circuit CO measure [OpCircCO]) method or calculation based on oxygen consumption (oxygen consumption-based CO [VO2CO]) during exercise. Methods: For the present study, 14 healthy subjects (male: n = 12, female: n = 2) performed incremental exercise on a recumbent cycle ergometer. At rest and during exercise, cardiac output (CO) was obtained via the eSTICO method, while the OpenCircCO and VO2CO measures were obtained at the last minute of each workload. Results: At peak, there was no difference between eSTICO and OpCircCO (12.39 ± 3.06 vs. 13.96 ± 2.47 L/min, p > 0.05), while there was a slight difference between eSTICO and VO2CO (12.39 ± 3.06 vs. 14.28 ± 2.55 L/min, p < 0.05). When we performed correlation analysis with all subjects and all measures of CO at all WL, between eSTICO and OpenCircCO, there was a good relationship (r = 0.707, p < 0.001) with a Bland and Altman agreement analysis demonstrating a −1.6 difference (95% LoA: −6.3–3.5). Between eSTICO and VO2CO, we observed an r = 0.865 (p < 0.001) and a Bland and Altman agreement analysis with a −1.2 difference (95% LoA: −4.8–2.4). Conclusion: A novel exploitation of cardiac hemodynamics using systolic timing intervals may allow a relatively good assessment of CO during exercise in healthy adults.
- 1 May 2023
- Published by American Physiological Society in Physiology
- Vol. 38 (S1)
Comparison of shear-wave elastography to state-of-the-art respiratory function testing to measure the range of forces generated by the diaphragm muscle
The diaphragm muscle is important in both sustaining ventilation and performing higher-force behaviors necessary for maintaining airway patency. Ventilatory behaviors (i.e., eupnea and response to hypoxia-hypercapnia) require only ~20% of maximal force generation, whereas coughing requires forces ~60% of maximal. Existing techniques to measure the full range of forces generated by respiratory muscles are limited by their invasiveness (e.g., balloon manometry for transdiaphragmatic pressure (Pdi) measurements), requirements for training, supervision and subjectivity (e.g., maximal inspiratory and expiratory pressures). Ultrasound-based shear-wave elastography (SWE) assesses muscle stiffness and has shown promising results in being used as a surrogate for Pdi to evaluate diaphragm muscle force. Previous literature has demonstrated a correlation between diaphragm SWE and Pdi at lower force behaviors and the goal of the present study was to evaluate the efficacy of SWE-based measurements of the diaphragm in correlating with Pdi measurements across the range of forces generated by the diaphragm. In this pilot study, we recruited 6 male and 5 female healthy volunteers. Subjects were positioned in a seated position with their torso unsupported. Pdi was measured during graded inspiratory threshold loading trials using a POWERbreathe Plus commercial inspiratory loading device, as well as during maximal inspiratory pressure (MIP). Simultaneously, SWE was performed at the zone of apposition in the right anterior axillary line, and diaphragm Young’s modulus and shear wave speed were subsequently measured. The average Pdi during MIP testing was 149 ± 66 cm H2O. Pdi during inspiratory loading at a low resistance was 39 ± 14 cm H2O and at a high resistance was 78 ± 29 cm H2O. Subjects were able to generate an average Pdi range of 39 ± 19 cm H2O across the graded resistance levels, and the average percent of MIP obtained was 54 ± 13%. Average Young’s modulus as measured with SWE during inspiratory loading at a low resistance was 46 ± 19 kPa and at a high resistance was 104 ± 19 kPa. From low to high resistance, Pdi, Young’s modulus, and shear wave speed increased by an average of 100%, 126%, and 59%, respectively. Taken together, SWE is a promising method of non-invasive assessment of diaphragm muscle forces across a range of voluntary behaviors. Support from NIH grant R21 DA055848 and the Mayo Clinic. This is the full abstract presented at the American Physiology Summit 2023 meeting and is only available in HTML format. There are no additional versions or additional content available for this Physiology was not involved in the peer review process.
- 1 May 2023
- Published by American Physiological Society in Physiology
- Vol. 38 (S1)
Comparison of shear-wave elastography to state-of-the-art respiratory function testing to measure the range of forces generated by the diaphragm muscle
The diaphragm muscle is important in both sustaining ventilation and performing higher-force behaviors necessary for maintaining airway patency. Ventilatory behaviors (i.e., eupnea and response to hypoxia-hypercapnia) require only ~20% of maximal force generation, whereas coughing requires forces ~60% of maximal. Existing techniques to measure the full range of forces generated by respiratory muscles are limited by their invasiveness (e.g., balloon manometry for transdiaphragmatic pressure (Pdi) measurements), requirements for training, supervision and subjectivity (e.g., maximal inspiratory and expiratory pressures). Ultrasound-based shear-wave elastography (SWE) assesses muscle stiffness and has shown promising results in being used as a surrogate for Pdi to evaluate diaphragm muscle force. Previous literature has demonstrated a correlation between diaphragm SWE and Pdi at lower force behaviors and the goal of the present study was to evaluate the efficacy of SWE-based measurements of the diaphragm in correlating with Pdi measurements across the range of forces generated by the diaphragm. In this pilot study, we recruited 6 male and 5 female healthy volunteers. Subjects were positioned in a seated position with their torso unsupported. Pdi was measured during graded inspiratory threshold loading trials using a POWERbreathe Plus commercial inspiratory loading device, as well as during maximal inspiratory pressure (MIP). Simultaneously, SWE was performed at the zone of apposition in the right anterior axillary line, and diaphragm Young’s modulus and shear wave speed were subsequently measured. The average Pdi during MIP testing was 149 ± 66 cm H2O. Pdi during inspiratory loading at a low resistance was 39 ± 14 cm H2O and at a high resistance was 78 ± 29 cm H2O. Subjects were able to generate an average Pdi range of 39 ± 19 cm H2O across the graded resistance levels, and the average percent of MIP obtained was 54 ± 13%. Average Young’s modulus as measured with SWE during inspiratory loading at a low resistance was 46 ± 19 kPa and at a high resistance was 104 ± 19 kPa. From low to high resistance, Pdi, Young’s modulus, and shear wave speed increased by an average of 100%, 126%, and 59%, respectively. Taken together, SWE is a promising method of non-invasive assessment of diaphragm muscle forces across a range of voluntary behaviors. Support from NIH grant R21 DA055848 and the Mayo Clinic. This is the full abstract presented at the American Physiology Summit 2023 meeting and is only available in HTML format. There are no additional versions or additional content available for this Physiology was not involved in the peer review process.
- Open Access
- 29 April 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (9) , 1590
A Novel Spectral Index for Tracking Preload Change from a Wireless, Wearable Doppler Ultrasound
A wireless, wearable Doppler ultrasound offers a new paradigm for linking physiology to resuscitation medicine. To this end, the image analysis of simultaneously-acquired venous and arterial Doppler spectrograms attained by wearable ultrasound represents a new source of hemodynamic data. Previous investigators have reported a direct relationship between the central venous pressure (CVP) and the ratio of the internal jugular-to-common carotid artery diameters. Because Doppler power is directly related to the number of red cell scatterers within a vessel, we hypothesized that (1) the ratio of internal jugular-to-carotid artery Doppler power (V/APOWER) would be a surrogate for the ratio of the vascular areas of these two vessels and (2) the V/APOWER would track the anticipated CVP change during simulated hemorrhage and resuscitation. To illustrate this proof-of-principle, we compared the change in V/APOWER obtained via a wireless, wearable Doppler ultrasound to B-mode ultrasound images during a head-down tilt. Additionally, we elucidated the change in the V/APOWER during simulated hemorrhage and transfusion via lower body negative pressure (LBNP) and release. With these Interesting Images, we show that the Doppler V/APOWER ratio qualitatively tracks anticipated changes in CVP (e.g., cardiac preload) which is promising for both diagnosis and management of hemodynamic unrest.
- 29 April 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (9) , 1590
Open AccessA Novel Spectral Index for Tracking Preload Change from a Wireless, Wearable Doppler Ultrasound
A wireless, wearable Doppler ultrasound offers a new paradigm for linking physiology to resuscitation medicine. To this end, the image analysis of simultaneously-acquired venous and arterial Doppler spectrograms attained by wearable ultrasound represents a new source of hemodynamic data. Previous investigators have reported a direct relationship between the central venous pressure (CVP) and the ratio of the internal jugular-to-common carotid artery diameters. Because Doppler power is directly related to the number of red cell scatterers within a vessel, we hypothesized that (1) the ratio of internal jugular-to-carotid artery Doppler power (V/APOWER) would be a surrogate for the ratio of the vascular areas of these two vessels and (2) the V/APOWER would track the anticipated CVP change during simulated hemorrhage and resuscitation. To illustrate this proof-of-principle, we compared the change in V/APOWER obtained via a wireless, wearable Doppler ultrasound to B-mode ultrasound images during a head-down tilt. Additionally, we elucidated the change in the V/APOWER during simulated hemorrhage and transfusion via lower body negative pressure (LBNP) and release. With these Interesting Images, we show that the Doppler V/APOWER ratio qualitatively tracks anticipated changes in CVP (e.g., cardiac preload) which is promising for both diagnosis and management of hemodynamic unrest.
- Open Access
- 16 December 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (24) , 16926
The Utility of High Intensity Interval Training to Improve Cognitive Aging in Heart Disease Patients
Adults with cardiovascular disease and heart failure are at higher risk of cognitive decline. Cerebral hypoperfusion appears to be a significant contributor, which can result from vascular dysfunction and impairment of cerebral blood flow regulation. In contrast, higher cardiorespiratory fitness shows protection against brain atrophy, reductions in cerebral blood flow, and cognitive decline. Given that high intensity interval training (HIIT) has been shown to be a potent stimulus for improving cardiorespiratory fitness and peripheral vascular function, its utility for improving cognitive aging is an important area of research. This article will review the physiology related to cerebral blood flow regulation and cognitive decline in adults with cardiovascular disease and heart failure, and how HIIT may provide a more optimal stimulus for improving cognitive aging in this population.
- 16 December 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (24) , 16926
Open AccessThe Utility of High Intensity Interval Training to Improve Cognitive Aging in Heart Disease Patients
Adults with cardiovascular disease and heart failure are at higher risk of cognitive decline. Cerebral hypoperfusion appears to be a significant contributor, which can result from vascular dysfunction and impairment of cerebral blood flow regulation. In contrast, higher cardiorespiratory fitness shows protection against brain atrophy, reductions in cerebral blood flow, and cognitive decline. Given that high intensity interval training (HIIT) has been shown to be a potent stimulus for improving cardiorespiratory fitness and peripheral vascular function, its utility for improving cognitive aging is an important area of research. This article will review the physiology related to cerebral blood flow regulation and cognitive decline in adults with cardiovascular disease and heart failure, and how HIIT may provide a more optimal stimulus for improving cognitive aging in this population.
- Open Access
Feasibility of Brachial Occlusion Technique for Beat-to-Beat Pulse Wave Analysis
Czech physiologist Penaz tried to overcome limitations of invasive pulse-contour methods (PCM) in clinical applications by a non-invasive method (finger mounted BP cuff) for continuous arterial waveform detection and beat-to-beat analysis. This discovery resulted in significant interest in human physiology and non-invasive examination of hemodynamic parameters, however has limitations because of the distal BP recording using a volume-clamp method. Thus, we propose a validation of beat-to-beat signal analysis acquired by novel a brachial occlusion-cuff (suprasystolic) principle and signal obtained from Finapres during a forced expiratory effort against an obstructed airway (Valsalva maneuver). Twelve healthy adult subjects [2 females, age = (27.2 ± 5.1) years] were in the upright siting position, breathe through the mouthpiece (simultaneously acquisition by brachial blood pressure monitor and Finapres) and at a defined time were asked to generate positive mouth pressure for 20 s (Valsalva). For the purpose of signal analysis, we proposed parameter a “Occlusion Cuff Index” (OCCI). The assumption about similarities between measured signals (suprasystolic brachial pulse waves amplitudes and Finapres’s MAP) were proved by averaged Pearson’s correlation coefficient ( = 0.60, p < 0.001). The averaged Pearson’s correlation coefficient for the comparative analysis of OCCI between methods was = 0.88, p < 0.001. The average percent change of OCCI during maneuver: 8% increase, 19% decrease and percent change of max/min ratio is 35%. The investigation of brachial pulse waves measured by novel brachial blood pressure monitor shows positive correlation with Finapres and the parameter OCCI shows promise as an index, which could describe changes during beat-to-beat cardiac cycles.Open AccessFeasibility of Brachial Occlusion Technique for Beat-to-Beat Pulse Wave Analysis
Czech physiologist Penaz tried to overcome limitations of invasive pulse-contour methods (PCM) in clinical applications by a non-invasive method (finger mounted BP cuff) for continuous arterial waveform detection and beat-to-beat analysis. This discovery resulted in significant interest in human physiology and non-invasive examination of hemodynamic parameters, however has limitations because of the distal BP recording using a volume-clamp method. Thus, we propose a validation of beat-to-beat signal analysis acquired by novel a brachial occlusion-cuff (suprasystolic) principle and signal obtained from Finapres during a forced expiratory effort against an obstructed airway (Valsalva maneuver). Twelve healthy adult subjects [2 females, age = (27.2 ± 5.1) years] were in the upright siting position, breathe through the mouthpiece (simultaneously acquisition by brachial blood pressure monitor and Finapres) and at a defined time were asked to generate positive mouth pressure for 20 s (Valsalva). For the purpose of signal analysis, we proposed parameter a “Occlusion Cuff Index” (OCCI). The assumption about similarities between measured signals (suprasystolic brachial pulse waves amplitudes and Finapres’s MAP) were proved by averaged Pearson’s correlation coefficient ( = 0.60, p < 0.001). The averaged Pearson’s correlation coefficient for the comparative analysis of OCCI between methods was = 0.88, p < 0.001. The average percent change of OCCI during maneuver: 8% increase, 19% decrease and percent change of max/min ratio is 35%. The investigation of brachial pulse waves measured by novel brachial blood pressure monitor shows positive correlation with Finapres and the parameter OCCI shows promise as an index, which could describe changes during beat-to-beat cardiac cycles. - Open Access
- 17 July 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (14) , 4151
Greater Muscular Strength Is Associated with a Lower Risk of Pulmonary Dysfunction in Individuals with Non-Alcoholic Fatty Liver Disease
This study investigated the combined effect of handgrip strength (HGS) and non-alcoholic fatty liver disease (NAFLD) on pulmonary function using the Korea National Health and Nutrition Examination Survey (KNHANES) from 2016 to 2018. For the present study, forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), the FEV1/FVC ratio, handgrip strength (HGS) and the hepatic steatosis index (HSI) to estimate NAFLD were obtained from nationwide cross-sectional surveys. For HGS, subjects were divided into higher HGS (upper 50%) and lower HGS (lower 50%). For NAFLD, subjects were divided into the NAFLD cohort (HSI > 36) and the normal cohort (HSI ≤ 36). Of 1651 subjects (men, n = 601), 25.5% of subjects (n = 421) met the HSI > 36. Based on the normal cohort with high HGS, the normal cohort with low HGS showed an increased risk of reduced FVC (OR = 3.062, 95% CI = 2.46–4.83, p < 0.001) and the NAFLD cohort with low HGS showed a further increased risk of reduced FVC (OR = 4.489, 95% CI = 3.43–7.09, p < 0.001). However, the risk of reduced FVC was not significantly increased in NAFLD with high HGS (OR = 1.297, 95% CI = 0.67–2.50, p = 0.436). After adjusted for covariates such as age, sex, smoking, FBG, HDL-C, TG, SBP, DBP, CRP and alcohol consumption, the results remained similar. More importantly, these results were consistent in the obesity-stratified analysis. The current findings of the study suggest that higher muscle strength is associated with a lower risk of reduced pulmonary function in individuals with NAFLD.
- 17 July 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (14) , 4151
Open AccessGreater Muscular Strength Is Associated with a Lower Risk of Pulmonary Dysfunction in Individuals with Non-Alcoholic Fatty Liver Disease
This study investigated the combined effect of handgrip strength (HGS) and non-alcoholic fatty liver disease (NAFLD) on pulmonary function using the Korea National Health and Nutrition Examination Survey (KNHANES) from 2016 to 2018. For the present study, forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), the FEV1/FVC ratio, handgrip strength (HGS) and the hepatic steatosis index (HSI) to estimate NAFLD were obtained from nationwide cross-sectional surveys. For HGS, subjects were divided into higher HGS (upper 50%) and lower HGS (lower 50%). For NAFLD, subjects were divided into the NAFLD cohort (HSI > 36) and the normal cohort (HSI ≤ 36). Of 1651 subjects (men, n = 601), 25.5% of subjects (n = 421) met the HSI > 36. Based on the normal cohort with high HGS, the normal cohort with low HGS showed an increased risk of reduced FVC (OR = 3.062, 95% CI = 2.46–4.83, p < 0.001) and the NAFLD cohort with low HGS showed a further increased risk of reduced FVC (OR = 4.489, 95% CI = 3.43–7.09, p < 0.001). However, the risk of reduced FVC was not significantly increased in NAFLD with high HGS (OR = 1.297, 95% CI = 0.67–2.50, p = 0.436). After adjusted for covariates such as age, sex, smoking, FBG, HDL-C, TG, SBP, DBP, CRP and alcohol consumption, the results remained similar. More importantly, these results were consistent in the obesity-stratified analysis. The current findings of the study suggest that higher muscle strength is associated with a lower risk of reduced pulmonary function in individuals with NAFLD.
- Open Access
- 21 May 2022
- Published by Wolters Kluwer Health in Journal of Trauma and Acute Care Surgery
- Vol. 93 (2S) , S35-S40
A wireless ultrasound patch detects mild-to-moderate central hypovolemia during lower body negative pressure
BACKGROUND: We have developed a wireless, wearable Doppler ultrasound system that continuously measures the common carotid artery Doppler pulse. A novel measure from this device, the Doppler shock index, accurately detected moderate-to-severe central blood volume loss in a human hemorrhage model generated by lower body negative pressure. In this analysis, we tested whether the wearable Doppler could identify only mild-to-moderate central blood volume loss. METHODS: Eleven healthy volunteers were recruited and studied in a physiology laboratory at the Mayo Clinic. Each participant underwent a lower body negative protocol in duplicate. Carotid Doppler measures including Doppler shock indices were compared with blood pressure and the shock index for their ability to detect both 10% and 20% reductions in stroke volume. RESULTS: All carotid Doppler measures were better able to detect diminishing stroke volume than either systolic or mean arterial pressure. Falling carotid artery corrected flow time and rising heart rate/corrected flow time (DSIFTc) were the most sensitive measures for detecting 10% and 20% stroke volume reductions, respectively. The area under the receiver operator curves (AUROCs) for all shock indices was at least 0.86; however, the denominators of the two Doppler shock indices (i.e., the corrected flow time and velocity time integral) had AUROCs ranging between 0.81 and 0.9, while the denominator of the traditional shock index (i.e., systolic blood pressure) had AUROCs between 0.54 and 0.7. CONCLUSION: The wearable Doppler ultrasound was able to continuously measure the common carotid artery Doppler pulse. Carotid Doppler measures were highly sensitive at detecting both 10% and 20% stroke volume reduction. All shock indices performed well in their diagnostic ability to measure mild-to-moderate central volume loss, although the denominators of both Doppler shock indices individually outperformed the denominator of the traditional shock index. LEVEL OF EVIDENCE: Diagnostic test or criteria; Level III.
- 21 May 2022
- Published by Wolters Kluwer Health in Journal of Trauma and Acute Care Surgery
- Vol. 93 (2S) , S35-S40
Open AccessA wireless ultrasound patch detects mild-to-moderate central hypovolemia during lower body negative pressure
BACKGROUND: We have developed a wireless, wearable Doppler ultrasound system that continuously measures the common carotid artery Doppler pulse. A novel measure from this device, the Doppler shock index, accurately detected moderate-to-severe central blood volume loss in a human hemorrhage model generated by lower body negative pressure. In this analysis, we tested whether the wearable Doppler could identify only mild-to-moderate central blood volume loss. METHODS: Eleven healthy volunteers were recruited and studied in a physiology laboratory at the Mayo Clinic. Each participant underwent a lower body negative protocol in duplicate. Carotid Doppler measures including Doppler shock indices were compared with blood pressure and the shock index for their ability to detect both 10% and 20% reductions in stroke volume. RESULTS: All carotid Doppler measures were better able to detect diminishing stroke volume than either systolic or mean arterial pressure. Falling carotid artery corrected flow time and rising heart rate/corrected flow time (DSIFTc) were the most sensitive measures for detecting 10% and 20% stroke volume reductions, respectively. The area under the receiver operator curves (AUROCs) for all shock indices was at least 0.86; however, the denominators of the two Doppler shock indices (i.e., the corrected flow time and velocity time integral) had AUROCs ranging between 0.81 and 0.9, while the denominator of the traditional shock index (i.e., systolic blood pressure) had AUROCs between 0.54 and 0.7. CONCLUSION: The wearable Doppler ultrasound was able to continuously measure the common carotid artery Doppler pulse. Carotid Doppler measures were highly sensitive at detecting both 10% and 20% stroke volume reduction. All shock indices performed well in their diagnostic ability to measure mild-to-moderate central volume loss, although the denominators of both Doppler shock indices individually outperformed the denominator of the traditional shock index. LEVEL OF EVIDENCE: Diagnostic test or criteria; Level III.
- 28 April 2022
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 28 (5) , S109
Patients With Congestive Heart Failure Show Greater Incidence Of Cognitive Impairment And Dementia
- 28 April 2022
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 28 (5) , S109
Patients With Congestive Heart Failure Show Greater Incidence Of Cognitive Impairment And Dementia