A. Meier-Hellmann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
A. Meier-Hellmann has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
K. Reinhart
Department of Anaesthesiology and Intensive Care Medicine, Friedrich-Schiller-University of Jena, Bachstrasse 18, 07 740 Jena, Germany. uni-jena.de Tel.: + 49-36 41-93 30 41 Fax: + 49-36 41-93 32 56
2 shared publicationsS. G. Sakka
Department of Anaesthesiology and Intensive Care Medicine, Friedrich-Schiller-University of Jena, Germany
2 shared publicationsA. McLuckie
Department of Intensive Care Medicine, Guy's Hospital, London, UK
1 shared publicationC. C. Rühl
Institute for Experimental Surgery, Technical University of Munich, Munich, Germany
1 shared publicationR. Beale
Department of Intensive Care Medicine, Guy's Hospital, London, UK
1 shared publicationU. J. Pfeiffer
Technical University of Munich and Pulsion Medical Systems AG, Munich, Germany
1 shared publication
Latest Publications
- Top Cited Papers
- 9 March 2000
- Published by Springer Nature in Intensive Care Medicine
- Vol. 26 (2) , 180-187
Assessment of cardiac preload and extravascular lung water by single transpulmonary thermodilution
Objective: Transpulmonary double-indicator dilution is a useful monitoring technique for measurement of intrathoracic blood volume (ITBV) and extravascular lung water (EVLW). In this study, we compared a simpler approach using single arterial thermodilution derived measurements of ITBV and EVLW with the double-indicator dilution technique.¶Design: Prospective observational clinical study.¶Setting: Surgical intensive care units of two university hospitals.¶Patients and methods: Global end-diastolic volume (GEDV) derived from single thermodilution was used for calculation of ITBV. Structural regression analysis of the first two thermo-dye dilution measurements in a derivation population of 57 critically ill patients (38 male, 19 female, 18–79 years, 56 ± 15 years) revealed ITBV = (1.25 · GEDV)–28.4 (ml). This equation was then applied to all first measurements in a validation population of 209 critically ill patients (139 male, 70 female, 10–88 years, mean 53 ± 19 years), and single-thermodilution ITBV (ITBVST) and EVLW (EVLWST) was calculated and compared to thermo-dye dilution derived values (ITBVTD, EVLWTD). For inter-individual comparison, absolute values for ITBV and EVLW were normalised as indexed by body surface area (ITBVI) and body weight (EVLWI), respectively.¶Measurements and results: Linear regression analysis yielded a correlation of ITBVIST = (1.05 · ITBVITD)–58.0 (ml/m2), r = 0.97, P < 0.0001. Bias between ITBVITD and ITBVIST was 7.6 (ml/m2) with a standard deviation of 57.4 (ml/m2). Single-thermodilution EVLWI (EVLWIST) was calculated using ITBVIST and revealed the correlation EVLWIST = (0.83 · EVLWITD) + 1.6 (ml/kg), r = 0.96, P < 0.0001. Bias between EVLWITD and EVLWIST was –0.2 (ml/kg) with a standard deviation of 1.4 (ml/kg). In detail, EVLWIST systematically overestimated EVLWITD at low-normal values for EVLWI and underestimated EVLWI at higher values (above 12 ml/kg).¶Conclusion: Determinations of ITBV and EVLW by single thermodilution agreed closely with the corresponding values from the double-indicator technique. Since transpulmonary single thermodilution is simple to apply, less invasive and cheaper, all these features make it a promising technique for the bedside. Nevertheless, further validation studies are needed in the future.
- 9 March 2000
- Published by Springer Nature in Intensive Care Medicine
- Vol. 26 (2) , 180-187
Top Cited PapersAssessment of cardiac preload and extravascular lung water by single transpulmonary thermodilution
Objective: Transpulmonary double-indicator dilution is a useful monitoring technique for measurement of intrathoracic blood volume (ITBV) and extravascular lung water (EVLW). In this study, we compared a simpler approach using single arterial thermodilution derived measurements of ITBV and EVLW with the double-indicator dilution technique.¶Design: Prospective observational clinical study.¶Setting: Surgical intensive care units of two university hospitals.¶Patients and methods: Global end-diastolic volume (GEDV) derived from single thermodilution was used for calculation of ITBV. Structural regression analysis of the first two thermo-dye dilution measurements in a derivation population of 57 critically ill patients (38 male, 19 female, 18–79 years, 56 ± 15 years) revealed ITBV = (1.25 · GEDV)–28.4 (ml). This equation was then applied to all first measurements in a validation population of 209 critically ill patients (139 male, 70 female, 10–88 years, mean 53 ± 19 years), and single-thermodilution ITBV (ITBVST) and EVLW (EVLWST) was calculated and compared to thermo-dye dilution derived values (ITBVTD, EVLWTD). For inter-individual comparison, absolute values for ITBV and EVLW were normalised as indexed by body surface area (ITBVI) and body weight (EVLWI), respectively.¶Measurements and results: Linear regression analysis yielded a correlation of ITBVIST = (1.05 · ITBVITD)–58.0 (ml/m2), r = 0.97, P < 0.0001. Bias between ITBVITD and ITBVIST was 7.6 (ml/m2) with a standard deviation of 57.4 (ml/m2). Single-thermodilution EVLWI (EVLWIST) was calculated using ITBVIST and revealed the correlation EVLWIST = (0.83 · EVLWITD) + 1.6 (ml/kg), r = 0.96, P < 0.0001. Bias between EVLWITD and EVLWIST was –0.2 (ml/kg) with a standard deviation of 1.4 (ml/kg). In detail, EVLWIST systematically overestimated EVLWITD at low-normal values for EVLWI and underestimated EVLWI at higher values (above 12 ml/kg).¶Conclusion: Determinations of ITBV and EVLW by single thermodilution agreed closely with the corresponding values from the double-indicator technique. Since transpulmonary single thermodilution is simple to apply, less invasive and cheaper, all these features make it a promising technique for the bedside. Nevertheless, further validation studies are needed in the future.
- 19 August 1999
- Published by Springer Nature in Intensive Care Medicine
- Vol. 25 (8) , 843-846
Comparison of pulmonary artery and arterial thermodilution cardiac output in critically ill patients
Objective: We studied the agreement between cardiac output measurements via pulmonary artery thermodilution [CO(PA)], regarded as the current clinical gold standard, and aortic transpulmonary thermodilution [CO(AORTA)]. Design: Prospective clinical study. Setting: Surgical intensive care unit of a university hospital. Patients: 37 patients with sepsis or septic shock (n = 34) and subarachnoid haemorrhage (n = 3). Measurements and results: We analysed 449 simultaneous cardiac output measurements. All patients were deeply sedated and mechanically ventilated in a pressure controlled mode. Each patient received a 7.5-F five-lumen pulmonary artery catheter and a 4-F aortic catheter with an integrated thermistor. The thermistors of the two different catheters were connected to one computer system (COLD-Z021, Pulsion Medical Systems, Munich, Germany). Linear regression analysis revealed: CO(AORTA) = 0.96 · CO(PA) + 1.02 (l/min) (r = 0.97, p < 0.0001). CO(AORTA) was consistently higher than CO(PA) with a bias of 0.68 (l/min) and a standard deviation of 0.62 (l/min). Conclusion: Cardiac output derived from aortic transpulmonary thermodilution is suitable for measurement in the intensive care unit. Measurements of CO(AORTA) are consistent with, but slightly higher than, those obtained from pulmonary artery thermodilution.
- 19 August 1999
- Published by Springer Nature in Intensive Care Medicine
- Vol. 25 (8) , 843-846
Comparison of pulmonary artery and arterial thermodilution cardiac output in critically ill patients
Objective: We studied the agreement between cardiac output measurements via pulmonary artery thermodilution [CO(PA)], regarded as the current clinical gold standard, and aortic transpulmonary thermodilution [CO(AORTA)]. Design: Prospective clinical study. Setting: Surgical intensive care unit of a university hospital. Patients: 37 patients with sepsis or septic shock (n = 34) and subarachnoid haemorrhage (n = 3). Measurements and results: We analysed 449 simultaneous cardiac output measurements. All patients were deeply sedated and mechanically ventilated in a pressure controlled mode. Each patient received a 7.5-F five-lumen pulmonary artery catheter and a 4-F aortic catheter with an integrated thermistor. The thermistors of the two different catheters were connected to one computer system (COLD-Z021, Pulsion Medical Systems, Munich, Germany). Linear regression analysis revealed: CO(AORTA) = 0.96 · CO(PA) + 1.02 (l/min) (r = 0.97, p < 0.0001). CO(AORTA) was consistently higher than CO(PA) with a bias of 0.68 (l/min) and a standard deviation of 0.62 (l/min). Conclusion: Cardiac output derived from aortic transpulmonary thermodilution is suitable for measurement in the intensive care unit. Measurements of CO(AORTA) are consistent with, but slightly higher than, those obtained from pulmonary artery thermodilution.