Robert David Jarman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Robert David Jarman has a total of 98 co-authors. Here are the top co-authors by number of shared publications:
- Cian McDermott
Mater University Hospital
4 shared publications Beatrice Hoffmann
Emergency Department, Harvard Medical School Department of Emergency Medicine Beth Israel Deaconess Medical Center, Boston, United States
3 shared publications- Michael Trauer
School of Health and Life Sciences, Teesside University, Middlesbrough, UK
3 shared publications Adam Bystrzycki
Emergency Medicine, The Alfred Emergency & Trauma Centre, Melbourne, Australia
2 shared publicationsAdhnan Omar
Respiratory Medicine, University Hospital Lewisham, London, United Kingdom of Great Britain and Northern Ireland
2 shared publicationsAdrian Goudie
Emergency Medicine, Fiona Stanley Hospital, Murdoch, Australia
2 shared publications
Latest Publications
- 16 May 2024
- Published by SAGE Publications in Ultrasound
- Vol. 32 (4) , 271-282
LogMyScan: A pilot evaluation study of a mobile phone–based ultrasound logbook application
Introduction: We developed a mobile phone logbook application called LogMyScan. The study objectives were to evaluate a number of domains as per the technology acceptance model. Methods: A prospective pilot cohort study was conducted using a version of LogMyScan and reported according to Statement on Reporting of Evaluation studies in Health Informatics. Prospective participants were directed to a website which provided information and links. Participants were recruited via email distribution lists and social media. A task list was provided, which included entering simulated scan data and navigating the application, prior to completing a questionnaire. Questions were aligned to technology acceptance model domains, and Cronbach’s alpha was calculated to assess reliability. Results: There were 49 participants and 7 were unable to complete the image upload and editing step. Levels of agreement for usability, educational and governance/security aspects were generally good. The desirability of existing and proposed features was high for images and video clip handling, feedback and reflection and less for motivational notifications and benchmarking. Comments identified some limitations and issues on the Android platform. Cronbach’s alpha demonstrated good to excellent reliability: 0.87 (95% confidence interval, 0.79–0.91) for usability, educational and governance/security and 0.86 (95% confidence interval, 0.78–0.91) for desirability of existing and proposed features. Conclusion: There was generally high perceived ease of use, usefulness, attitude towards use and behavioural intention to use LogMyScan. Further research is needed to evaluate LogMyScan for future iterations, allowing recruitment of a larger number of participants and evaluating user expectations prior to using, and at timed intervals after using.
- 16 May 2024
- Published by SAGE Publications in Ultrasound
- Vol. 32 (4) , 271-282
LogMyScan: A pilot evaluation study of a mobile phone–based ultrasound logbook application
Introduction: We developed a mobile phone logbook application called LogMyScan. The study objectives were to evaluate a number of domains as per the technology acceptance model. Methods: A prospective pilot cohort study was conducted using a version of LogMyScan and reported according to Statement on Reporting of Evaluation studies in Health Informatics. Prospective participants were directed to a website which provided information and links. Participants were recruited via email distribution lists and social media. A task list was provided, which included entering simulated scan data and navigating the application, prior to completing a questionnaire. Questions were aligned to technology acceptance model domains, and Cronbach’s alpha was calculated to assess reliability. Results: There were 49 participants and 7 were unable to complete the image upload and editing step. Levels of agreement for usability, educational and governance/security aspects were generally good. The desirability of existing and proposed features was high for images and video clip handling, feedback and reflection and less for motivational notifications and benchmarking. Comments identified some limitations and issues on the Android platform. Cronbach’s alpha demonstrated good to excellent reliability: 0.87 (95% confidence interval, 0.79–0.91) for usability, educational and governance/security and 0.86 (95% confidence interval, 0.78–0.91) for desirability of existing and proposed features. Conclusion: There was generally high perceived ease of use, usefulness, attitude towards use and behavioural intention to use LogMyScan. Further research is needed to evaluate LogMyScan for future iterations, allowing recruitment of a larger number of participants and evaluating user expectations prior to using, and at timed intervals after using.
- Open Access
- 3 March 2023
- Published by BMJ in Emergency Medicine Journal
- Vol. 40 (6) , 407-417
Diagnostic accuracy of point-of-care lung ultrasound for COVID-19: a systematic review and meta-analysis
Background: Point-of-care (POC) lung ultrasound (LUS) is widely used in the emergency setting and there is an established evidence base across a range of respiratory diseases, including previous viral epidemics. The necessity for rapid testing combined with the limitations of other diagnostic tests has led to the proposal of various potential roles for LUS during the COVID-19 pandemic. This systematic review and meta-analysis focused specifically on the diagnostic accuracy of LUS in adult patients presenting with suspected COVID-19 infection.Methods: Traditional and grey-literature searches were performed on 1 June 2021. Two authors independently carried out the searches, selected studies and completed the Quality Assessment Tool for Diagnostic Test Accuracy Studies (QUADAS-2). Meta-analysis was carried out using established open-source packages inR. We report overall sensitivity, specificity, positive and negative predictive values, and the hierarchical summary receiver operating characteristic curve for LUS. Heterogeneity was determined using the I2statistic.Results: Twenty studies were included, published between October 2020 and April 2021, providing data from a total of 4314 patients. The prevalence and admission rates were generally high across all studies. Overall, LUS was found to be 87.2% sensitive (95% CI 83.6 to 90.2) and 69.5% specific (95% CI 62.2 to 72.5) and demonstrated overall positive and negative likelihood ratios of 3.0 (95% CI 2.3 to 4.1) and 0.16 (95% CI 0.12 to 0.22), respectively. Separate analyses for each reference standard revealed similar sensitivities and specificities for LUS. Heterogeneity was found to be high across the studies. Overall, the quality of studies was low with a high risk of selection bias due to convenience sampling. There were also applicability concerns because all studies were undertaken during a period of high prevalence.Conclusion: During a period of high prevalence, LUS had a sensitivity of 87% for the diagnosis of COVID-19 infection. However, more research is required to confirm these results in more generalisable populations, including those less likely to be admitted to hospital.PROSPERO registration number: CRD42021250464
- 3 March 2023
- Published by BMJ in Emergency Medicine Journal
- Vol. 40 (6) , 407-417
Open AccessDiagnostic accuracy of point-of-care lung ultrasound for COVID-19: a systematic review and meta-analysis
Background: Point-of-care (POC) lung ultrasound (LUS) is widely used in the emergency setting and there is an established evidence base across a range of respiratory diseases, including previous viral epidemics. The necessity for rapid testing combined with the limitations of other diagnostic tests has led to the proposal of various potential roles for LUS during the COVID-19 pandemic. This systematic review and meta-analysis focused specifically on the diagnostic accuracy of LUS in adult patients presenting with suspected COVID-19 infection.Methods: Traditional and grey-literature searches were performed on 1 June 2021. Two authors independently carried out the searches, selected studies and completed the Quality Assessment Tool for Diagnostic Test Accuracy Studies (QUADAS-2). Meta-analysis was carried out using established open-source packages inR. We report overall sensitivity, specificity, positive and negative predictive values, and the hierarchical summary receiver operating characteristic curve for LUS. Heterogeneity was determined using the I2statistic.Results: Twenty studies were included, published between October 2020 and April 2021, providing data from a total of 4314 patients. The prevalence and admission rates were generally high across all studies. Overall, LUS was found to be 87.2% sensitive (95% CI 83.6 to 90.2) and 69.5% specific (95% CI 62.2 to 72.5) and demonstrated overall positive and negative likelihood ratios of 3.0 (95% CI 2.3 to 4.1) and 0.16 (95% CI 0.12 to 0.22), respectively. Separate analyses for each reference standard revealed similar sensitivities and specificities for LUS. Heterogeneity was found to be high across the studies. Overall, the quality of studies was low with a high risk of selection bias due to convenience sampling. There were also applicability concerns because all studies were undertaken during a period of high prevalence.Conclusion: During a period of high prevalence, LUS had a sensitivity of 87% for the diagnosis of COVID-19 infection. However, more research is required to confirm these results in more generalisable populations, including those less likely to be admitted to hospital.PROSPERO registration number: CRD42021250464
- 13 October 2022
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 44 (01) , 36-49
EFSUMB Clinical Practice Guidelines for Point-of-Care Ultrasound: Part One (Common Heart and Pulmonary Applications) SHORT VERSION
Objective To evaluate the evidence and produce a summary and recommendations for the most common heart and lung point-of-care ultrasound (PoCUS). Methods We reviewed 10 clinical domains/questions related to common heart and lung applications of PoCUS. Following review of the evidence, a summary and recommendations were produced, including assigning levels of evidence (LoE) and grading of recommendation, assessment, development, and evaluation (GRADE). 38 international experts, the expert review group (ERG), were invited to review the evidence presented for each question. A level of agreement of over 75 % was required to progress to the next section. The ERG then reviewed and indicated their level of agreement of the summary and recommendation for each question (using a 5-point Likert scale), which was approved in the case of a level of agreement of greater than 75 %. A level of agreement was defined as a summary of “strongly agree” and “agree” on the Likert scale responses. Findings and Recommendations One question achieved a strong consensus for an assigned LoE of 3 and a weak GRADE recommendation (question 1), the remaining 9 questions achieved broad agreement with an assigned LoE of 4 and a weak GRADE recommendation (question 2), three achieved an LoE of 3 with a weak GRADE recommendation (questions 3–5), three achieved an LoE of 3 with a strong GRADE recommendation (questions 6–8) and the remaining two were assigned an LoE of 2 with a strong GRADE recommendation (questions 9 and 10). Conclusion These consensus-derived recommendations should aid clinical practice and highlight areas of further research for PoCUS in acute settings.
- 13 October 2022
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 44 (01) , 36-49
EFSUMB Clinical Practice Guidelines for Point-of-Care Ultrasound: Part One (Common Heart and Pulmonary Applications) SHORT VERSION
Objective To evaluate the evidence and produce a summary and recommendations for the most common heart and lung point-of-care ultrasound (PoCUS). Methods We reviewed 10 clinical domains/questions related to common heart and lung applications of PoCUS. Following review of the evidence, a summary and recommendations were produced, including assigning levels of evidence (LoE) and grading of recommendation, assessment, development, and evaluation (GRADE). 38 international experts, the expert review group (ERG), were invited to review the evidence presented for each question. A level of agreement of over 75 % was required to progress to the next section. The ERG then reviewed and indicated their level of agreement of the summary and recommendation for each question (using a 5-point Likert scale), which was approved in the case of a level of agreement of greater than 75 %. A level of agreement was defined as a summary of “strongly agree” and “agree” on the Likert scale responses. Findings and Recommendations One question achieved a strong consensus for an assigned LoE of 3 and a weak GRADE recommendation (question 1), the remaining 9 questions achieved broad agreement with an assigned LoE of 4 and a weak GRADE recommendation (question 2), three achieved an LoE of 3 with a weak GRADE recommendation (questions 3–5), three achieved an LoE of 3 with a strong GRADE recommendation (questions 6–8) and the remaining two were assigned an LoE of 2 with a strong GRADE recommendation (questions 9 and 10). Conclusion These consensus-derived recommendations should aid clinical practice and highlight areas of further research for PoCUS in acute settings.
- 13 October 2022
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 44 (01) , e1-e24
EFSUMB Clinical Practice Guidelines for Point-of-Care Ultrasound: Part One (Common Heart and Pulmonary Applications) LONG VERSION
Aims To evaluate the evidence and produce a summary and recommendations for the most common heart and lung applications of point-of-care ultrasound (PoCUS).Methods We reviewed 10 clinical domains/questions related to common heart and lung applications of PoCUS. Following review of the evidence, a summary and recommendation were produced, including assignment of levels of evidence (LoE) and grading of the recommendation, assessment, development, and evaluation (GRADE). 38 international experts, the expert review group (ERG), were invited to review the evidence presented for each question. A level of agreement of over 75 % was required to progress to the next section. The ERG then reviewed and indicated their level of agreement regarding the summary and recommendation for each question (using a 5-point Likert scale), which was approved if a level of agreement of greater than 75 % was reached. A level of agreement was defined as a summary of “strongly agree” and “agree” on the Likert scale responses.Findings and Recommendations One question achieved a strong consensus for an assigned LoE of 3 and a weak GRADE recommendation (question 1). The remaining 9 questions achieved broad agreement with one assigned an LoE of 4 and weak GRADE recommendation (question 2), three achieving an LoE of 3 with a weak GRADE recommendation (questions 3–5), three achieved an LoE of 3 with a strong GRADE recommendation (questions 6–8), and the remaining two were assigned an LoE of 2 with a strong GRADE recommendation (questions 9 and 10).Conclusion These consensus-derived recommendations should aid clinical practice and highlight areas of further research for PoCUS in acute settings.
- 13 October 2022
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 44 (01) , e1-e24
EFSUMB Clinical Practice Guidelines for Point-of-Care Ultrasound: Part One (Common Heart and Pulmonary Applications) LONG VERSION
Aims To evaluate the evidence and produce a summary and recommendations for the most common heart and lung applications of point-of-care ultrasound (PoCUS).Methods We reviewed 10 clinical domains/questions related to common heart and lung applications of PoCUS. Following review of the evidence, a summary and recommendation were produced, including assignment of levels of evidence (LoE) and grading of the recommendation, assessment, development, and evaluation (GRADE). 38 international experts, the expert review group (ERG), were invited to review the evidence presented for each question. A level of agreement of over 75 % was required to progress to the next section. The ERG then reviewed and indicated their level of agreement regarding the summary and recommendation for each question (using a 5-point Likert scale), which was approved if a level of agreement of greater than 75 % was reached. A level of agreement was defined as a summary of “strongly agree” and “agree” on the Likert scale responses.Findings and Recommendations One question achieved a strong consensus for an assigned LoE of 3 and a weak GRADE recommendation (question 1). The remaining 9 questions achieved broad agreement with one assigned an LoE of 4 and weak GRADE recommendation (question 2), three achieving an LoE of 3 with a weak GRADE recommendation (questions 3–5), three achieved an LoE of 3 with a strong GRADE recommendation (questions 6–8), and the remaining two were assigned an LoE of 2 with a strong GRADE recommendation (questions 9 and 10).Conclusion These consensus-derived recommendations should aid clinical practice and highlight areas of further research for PoCUS in acute settings.
- 1 November 2021
- Published by Elsevier in Resuscitation
- Vol. 168, 167-175
Transoesophageal echocardiography in cardiac arrest: A systematic review
- 1 November 2021
- Published by Elsevier in Resuscitation
- Vol. 168, 167-175
Transoesophageal echocardiography in cardiac arrest: A systematic review
- 20 September 2021
- Published by BMJ in Emergency Medicine Journal
- Vol. 39 (9) , 655-661
Diagnostic accuracy of point-of-care ultrasound (PoCUS) for shoulder dislocations and reductions in the emergency department: a diagnostic randomised control trial (RCT)
Background Following blunt trauma, diagnosis of shoulder dislocation based on physical examination alone is difficult due to possible concurrent proximal humeral fractures. X-rays are therefore used to confirm diagnosis. Results from recent observational studies comparing diagnostic accuracy of point-of-care ultrasound (PoCUS) with X-rays for shoulder dislocation have been encouraging. The aim of this study was to determine whether PoCUS improves diagnostic accuracy when used with physical examination for the diagnosis of shoulder dislocation, proximal humeral fracture and ascertaining successful reduction in the ED. Methods A prospective, single-centre, open, parallel randomised control study over a 6-month period was used to answer the research question and test the null hypothesis. Consecutive eligible adult patients attending the ED of Mater Dei Hospital in Malta were randomised to either the control (C) (physical examination only) or experimental group (E) (physical examination and a two-point PoCUS scan). The study objectives were to measure diagnostic accuracy for both examinations for detecting shoulder dislocation, any associated proximal humeral fractures and confirming reduction. X-rays were used as reference standard for both groups. Results 1206 patients were enrolled in this study (C n=600, E n=606). 290 dislocations (C n=132 and E n=158), 332 proximal humeral fractures (C n=154 and E n=178) and 278 reductions (C n=130 and E n=148) were analysed. A statistically significant difference (pConclusions The addition of PoCUS to a physical examination significantly improves diagnostic accuracy for dislocations, proximal humeral fractures and reduction confirmation. Trial registration number International Standard Randomised Controlled Trials Number Registry (ISRCTN17048126).
- 20 September 2021
- Published by BMJ in Emergency Medicine Journal
- Vol. 39 (9) , 655-661
Diagnostic accuracy of point-of-care ultrasound (PoCUS) for shoulder dislocations and reductions in the emergency department: a diagnostic randomised control trial (RCT)
Background Following blunt trauma, diagnosis of shoulder dislocation based on physical examination alone is difficult due to possible concurrent proximal humeral fractures. X-rays are therefore used to confirm diagnosis. Results from recent observational studies comparing diagnostic accuracy of point-of-care ultrasound (PoCUS) with X-rays for shoulder dislocation have been encouraging. The aim of this study was to determine whether PoCUS improves diagnostic accuracy when used with physical examination for the diagnosis of shoulder dislocation, proximal humeral fracture and ascertaining successful reduction in the ED. Methods A prospective, single-centre, open, parallel randomised control study over a 6-month period was used to answer the research question and test the null hypothesis. Consecutive eligible adult patients attending the ED of Mater Dei Hospital in Malta were randomised to either the control (C) (physical examination only) or experimental group (E) (physical examination and a two-point PoCUS scan). The study objectives were to measure diagnostic accuracy for both examinations for detecting shoulder dislocation, any associated proximal humeral fractures and confirming reduction. X-rays were used as reference standard for both groups. Results 1206 patients were enrolled in this study (C n=600, E n=606). 290 dislocations (C n=132 and E n=158), 332 proximal humeral fractures (C n=154 and E n=178) and 278 reductions (C n=130 and E n=148) were analysed. A statistically significant difference (pConclusions The addition of PoCUS to a physical examination significantly improves diagnostic accuracy for dislocations, proximal humeral fractures and reduction confirmation. Trial registration number International Standard Randomised Controlled Trials Number Registry (ISRCTN17048126).
- Open Access
LUNG ULTRASOUND FINDINGS IN PATIENTS WITH COVID-19 IN AN URBAN EMERGENCY DEPARTMENT IN THE UK – AN OBSERVATIONAL STUDY
COVID-19 can present with respiratory symptoms ranging from mild cough to viral pneumonia and ARDS. Lung ultrasonography has emerged as a promising imaging modality during the pandemic, but there is still a paucity of systematic analysis of lung ultrasound findings. In this retrospective observational study, 12 Zone ultrasound scans of COVID-19 positive patients were systematically analysed for pleural irregularities, subpleural consolidations, B lines, deep consolidations and effusions. Lung abnormalities were analysed according to overall frequency, frequency distribution in coronal and sagittal lung planes and were also correlated to clinical severity groups as determined by oxygenation deficit. Our results show that lung zones with abnormalities can occur juxtaposed to normal lung. Irregular pleural and small subpleural consolidations appear ubiquitously distributed throughout both lungs and occur early in the disease process. Wide B-lines are a predominant feature in COVID-19 infection. B-lines are found in a variety of patterns with number and width correlated to disease severity. In our analysis we also describe a previously unrecognised finding of small peri-pleural effusions in 8.7% of scans occurring in all areas of the lung. The current results form the basis for a more thorough understanding of the lung changes occurring in COVID-19 and the incorporation of lung ultrasound in the setting of COVID-19 infection including triage, diagnosis, treatment approach and prognosis.
Open AccessLUNG ULTRASOUND FINDINGS IN PATIENTS WITH COVID-19 IN AN URBAN EMERGENCY DEPARTMENT IN THE UK – AN OBSERVATIONAL STUDY
COVID-19 can present with respiratory symptoms ranging from mild cough to viral pneumonia and ARDS. Lung ultrasonography has emerged as a promising imaging modality during the pandemic, but there is still a paucity of systematic analysis of lung ultrasound findings. In this retrospective observational study, 12 Zone ultrasound scans of COVID-19 positive patients were systematically analysed for pleural irregularities, subpleural consolidations, B lines, deep consolidations and effusions. Lung abnormalities were analysed according to overall frequency, frequency distribution in coronal and sagittal lung planes and were also correlated to clinical severity groups as determined by oxygenation deficit. Our results show that lung zones with abnormalities can occur juxtaposed to normal lung. Irregular pleural and small subpleural consolidations appear ubiquitously distributed throughout both lungs and occur early in the disease process. Wide B-lines are a predominant feature in COVID-19 infection. B-lines are found in a variety of patterns with number and width correlated to disease severity. In our analysis we also describe a previously unrecognised finding of small peri-pleural effusions in 8.7% of scans occurring in all areas of the lung. The current results form the basis for a more thorough understanding of the lung changes occurring in COVID-19 and the incorporation of lung ultrasound in the setting of COVID-19 infection including triage, diagnosis, treatment approach and prognosis.
- Open Access
- 17 August 2020
- Published by SAGE Publications in Ultrasound
- Vol. 28 (4) , 208-222
The utility of lung ultrasound in COVID-19: A systematic scoping review
Introduction: Lung ultrasound (LUS) has an established evidence base and has proven useful in previous viral epidemics. An understanding of the utility of LUS in COVID-19 is crucial to determine its most suitable role based on local circumstances. Method: Online databases, specialist websites and social media platforms were searched to identify studies that explore the utility of LUS in COVID-19. Case reports and recommendations were excluded. Findings: In total, 33 studies were identified which represent a rapidly expanding evidence base for LUS in COVID-19. The quality of the included studies was relatively low; however, LUS certainly appears to be a highly sensitive and fairly specific test for COVID-19 in all ages and in pregnancy. Discussion: There may be LUS findings and patterns that are relatively specific to COVID-19; however, specificity may also be influenced by factors such as disease severity, pre-existing lung disease, operator experience, disease prevalence and the reference standard. Conclusion: LUS is almost certainly more sensitive than chest radiograph for COVID-19 and has several advantages over computed tomography and real-time polymerase chain reaction. High-quality research is needed into various aspects of LUS including: diagnostic accuracy in undifferentiated patients; triage and prognostication; monitoring progression and guiding interventions; the persistence of residual LUS findings; inter-observer agreement and the role of contrast-enhanced LUS.
- 17 August 2020
- Published by SAGE Publications in Ultrasound
- Vol. 28 (4) , 208-222
Open AccessThe utility of lung ultrasound in COVID-19: A systematic scoping review
Introduction: Lung ultrasound (LUS) has an established evidence base and has proven useful in previous viral epidemics. An understanding of the utility of LUS in COVID-19 is crucial to determine its most suitable role based on local circumstances. Method: Online databases, specialist websites and social media platforms were searched to identify studies that explore the utility of LUS in COVID-19. Case reports and recommendations were excluded. Findings: In total, 33 studies were identified which represent a rapidly expanding evidence base for LUS in COVID-19. The quality of the included studies was relatively low; however, LUS certainly appears to be a highly sensitive and fairly specific test for COVID-19 in all ages and in pregnancy. Discussion: There may be LUS findings and patterns that are relatively specific to COVID-19; however, specificity may also be influenced by factors such as disease severity, pre-existing lung disease, operator experience, disease prevalence and the reference standard. Conclusion: LUS is almost certainly more sensitive than chest radiograph for COVID-19 and has several advantages over computed tomography and real-time polymerase chain reaction. High-quality research is needed into various aspects of LUS including: diagnostic accuracy in undifferentiated patients; triage and prognostication; monitoring progression and guiding interventions; the persistence of residual LUS findings; inter-observer agreement and the role of contrast-enhanced LUS.
- Open Access
Utility of Lung Ultrasound in COVID-19: A Systematic Scoping Review
Lung ultrasound (LUS) has an established evidence base and has proven useful in previous viral epidemics. An understanding of the utility of LUS in COVID-19 is crucial to determine its most suitable role based on local circumstances. A scoping review was thus undertaken to explore the utility of LUS in COVID-19 and guide future research. 33 studies were identified which represent a rapidly expanding evidence base for LUS in COVID-19. The quality of the included studies was relatively low. However LUS appears to be a highly sensitive and fairly specific test for COVID-19 in all ages and in pregnancy and is almost certainly more sensitive than CXR. The precise diagnostic accuracy of LUS may be influenced by various factors including disease severity, pre-existing lung disease, scanning protocol, operator experience, disease prevalence and the reference standard. High quality research is needed in various fields including: diagnostic accuracy in undifferentiated patients; triage and prognostication; monitoring progression and guiding interventions; persistence of residual LUS findings; inter-observer agreement; and the role of contrast-enhanced LUS.
Open AccessUtility of Lung Ultrasound in COVID-19: A Systematic Scoping Review
Lung ultrasound (LUS) has an established evidence base and has proven useful in previous viral epidemics. An understanding of the utility of LUS in COVID-19 is crucial to determine its most suitable role based on local circumstances. A scoping review was thus undertaken to explore the utility of LUS in COVID-19 and guide future research. 33 studies were identified which represent a rapidly expanding evidence base for LUS in COVID-19. The quality of the included studies was relatively low. However LUS appears to be a highly sensitive and fairly specific test for COVID-19 in all ages and in pregnancy and is almost certainly more sensitive than CXR. The precise diagnostic accuracy of LUS may be influenced by various factors including disease severity, pre-existing lung disease, scanning protocol, operator experience, disease prevalence and the reference standard. High quality research is needed in various fields including: diagnostic accuracy in undifferentiated patients; triage and prognostication; monitoring progression and guiding interventions; persistence of residual LUS findings; inter-observer agreement; and the role of contrast-enhanced LUS.