Derek S. Stenquist
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Derek S. Stenquist has a total of 105 co-authors. Here are the top co-authors by number of shared publications:
Michael J. Weaver
Harvard Medical School Orthopedic Trauma Initiative, Boston, MA, USA; Brigham and Women's Hospital, Department of Orthopedic Trauma, Boston, MA, USA
7 shared publications- Nishant Suneja
Department of Orthopaedic Surgery, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
5 shared publications - Robert Kaspar Wagner
Harvard Medical School Orthopaedic Trauma Initiative, Boston, MA
5 shared publications - Arun Aneja
Harvard Medical School Orthopaedic Trauma Initiative, Boston, MA, USA
4 shared publications Arvind G. Von Keudell
Harvard Medical School Orthopedic Trauma Initiative, Boston, MA, USA; Brigham and Women's Hospital, Department of Orthopedic Trauma, Boston, MA, USA; Bispebjerg Hospital, University of Copenhagen, Bispebjerg Bakke 23, Copenhagen, KBH 2400, Denmark
4 shared publicationsArvind von Keudell
Brigham and Women's Hospital, Orthopaedic Surgery, Boston, MA, USA
4 shared publications
Latest Publications
- 23 September 2026
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
Cerclage for Fracture Reduction is Not Associated with Nonunion in Vancouver B or C Periprosthetic Femur Fractures with Stable Implants: A Multicenter Retrospective Study
OBJECTIVES: To determine whether circumferential cerclage wiring for fracture reduction during lateral locked plating (LLP) of Vancouver B1 and C periprosthetic femur fractures is associated with nonunion. METHODS: Design : Retrospective cohort study. Setting: Three academic Level I trauma centers. Patient Selection Criteria: Patients aged >50 years with a Vancouver B1 or C periprosthetic femur fracture (OTA/AO IV.3B1 and IV.3C) who underwent open reduction and internal fixation with a single LLP with or without circumferential cerclage for fracture reduction from 2010-2023 were included. Outcome Measures and Comparisons: The primary outcome was nonunion. The association between cerclage use and nonunion was assessed using multivariable logistic regression controlling for age, sex, ASA classification, and Vancouver classification. Secondary outcomes included deep infection and implant revision. RESULTS: 141 patients were included: 102 patients (72%; median age 78 years [IQR, 70-87]; 67% female) were treated with cerclage for fracture reduction and 39 patients (28%; median age 82 years [IQR, 70-89]; 85% female) were not. More patients treated with cerclage sustained a Vancouver B1 than Vancouver C fracture (n=78/102 [76%] vs. n=24/39 [24%]; P P =0.02), stainless steel (n=91/102 [89%] vs. n=27/39 [69%]; P P =0.001) in patients treated with cerclage. Nonunion occurred in 4 patients (4%) treated with cerclage and 4 patients (10%) without ( P =0.30). Cerclage use was not associated with developing nonunion in multivariable regression (adjusted odds ratio, 0.3; 95% CI, 0.1-1.8; P =0.19). Infection occurred in 6 patients (6%) treated with cerclage and 0 patients (0%) without ( P =0.28). Implant revision occurred in 8 patients (8%) treated with cerclage and 6 patients (15%) without ( P =0.31). CONCLUSIONS: While baseline between-group differences were noted in Vancouver classification, the judicious use of circumferential cerclage wiring for fracture reduction and stabilization in Vancouver B and C periprosthetic femur fractures with stable implants was not associated with nonunion. No differences were noted in incidence of deep infection or implant revision following cerclage use in this population. LEVEL OF EVIDENCE: Therapeutic Level III.
- 23 September 2026
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
Cerclage for Fracture Reduction is Not Associated with Nonunion in Vancouver B or C Periprosthetic Femur Fractures with Stable Implants: A Multicenter Retrospective Study
OBJECTIVES: To determine whether circumferential cerclage wiring for fracture reduction during lateral locked plating (LLP) of Vancouver B1 and C periprosthetic femur fractures is associated with nonunion. METHODS: Design : Retrospective cohort study. Setting: Three academic Level I trauma centers. Patient Selection Criteria: Patients aged >50 years with a Vancouver B1 or C periprosthetic femur fracture (OTA/AO IV.3B1 and IV.3C) who underwent open reduction and internal fixation with a single LLP with or without circumferential cerclage for fracture reduction from 2010-2023 were included. Outcome Measures and Comparisons: The primary outcome was nonunion. The association between cerclage use and nonunion was assessed using multivariable logistic regression controlling for age, sex, ASA classification, and Vancouver classification. Secondary outcomes included deep infection and implant revision. RESULTS: 141 patients were included: 102 patients (72%; median age 78 years [IQR, 70-87]; 67% female) were treated with cerclage for fracture reduction and 39 patients (28%; median age 82 years [IQR, 70-89]; 85% female) were not. More patients treated with cerclage sustained a Vancouver B1 than Vancouver C fracture (n=78/102 [76%] vs. n=24/39 [24%]; P P =0.02), stainless steel (n=91/102 [89%] vs. n=27/39 [69%]; P P =0.001) in patients treated with cerclage. Nonunion occurred in 4 patients (4%) treated with cerclage and 4 patients (10%) without ( P =0.30). Cerclage use was not associated with developing nonunion in multivariable regression (adjusted odds ratio, 0.3; 95% CI, 0.1-1.8; P =0.19). Infection occurred in 6 patients (6%) treated with cerclage and 0 patients (0%) without ( P =0.28). Implant revision occurred in 8 patients (8%) treated with cerclage and 6 patients (15%) without ( P =0.31). CONCLUSIONS: While baseline between-group differences were noted in Vancouver classification, the judicious use of circumferential cerclage wiring for fracture reduction and stabilization in Vancouver B and C periprosthetic femur fractures with stable implants was not associated with nonunion. No differences were noted in incidence of deep infection or implant revision following cerclage use in this population. LEVEL OF EVIDENCE: Therapeutic Level III.
- Open Access
- 11 September 2026
- Published by Wolters Kluwer Health in OTA International
- Vol. 9 (4)
Acute knee sepsis after intramedullary nailing of open tibial shaft fractures: a comparison of intra-articular and extra-articular approaches
Objectives: To compare the incidence of acute knee sepsis after intramedullary nailing of open tibial shaft fractures via intra-articular and extra-articular approaches. Design: Retrospective cohort analysis. Setting: Two academic Level I trauma centers. Patients/Participants: Adults treated with intramedullary nailing for open tibial shaft fractures between 2010 and 2023 with a minimum of 3-month follow-up. Intervention: Intramedullary nailing using an intra-articular (suprapatellar) or extra-articular (medial parapatellar, transtendinous, or lateral parapatellar) approach. Main Outcome Measurements: Acute knee sepsis, deep/superficial infection, reoperation, and nonunion. Results: A total of 293 patients with 295 fractures met inclusion criteria (75% male, median age 41 years, 28% active smokers). Ninety fractures underwent intra-articular nailing, and 205 underwent extra-articular nailing. There were no differences in injury energy, Gustilo–Anderson classification, or rates of external fixation between groups. Acute knee sepsis occurred in one patient (1.1%) in the intra-articular group and one patient (0.5%) in the extra-articular group. Deep infection occurred in 8.9% for intra-articular and 9.3% for extra-articular ( P > 0.999), and aseptic nonunion in 8% vs 7%, respectively ( P > 0.999). Conclusions: Acute knee sepsis after intramedullary nailing of open tibial shaft fractures was rare (0.7%). Knee sepsis was more common after suprapatellar nailing than extra-articular approaches (1.1% vs 0.5%), but the results are not statistically significant, and the study lacks power to draw definitive conclusions about relative risk with such low base rates. These findings may assist surgeons with approach selection and patient counseling, taking into account injury characteristics and technical considerations related to the procedure that are case-specific.
- 11 September 2026
- Published by Wolters Kluwer Health in OTA International
- Vol. 9 (4)
Open AccessAcute knee sepsis after intramedullary nailing of open tibial shaft fractures: a comparison of intra-articular and extra-articular approaches
Objectives: To compare the incidence of acute knee sepsis after intramedullary nailing of open tibial shaft fractures via intra-articular and extra-articular approaches. Design: Retrospective cohort analysis. Setting: Two academic Level I trauma centers. Patients/Participants: Adults treated with intramedullary nailing for open tibial shaft fractures between 2010 and 2023 with a minimum of 3-month follow-up. Intervention: Intramedullary nailing using an intra-articular (suprapatellar) or extra-articular (medial parapatellar, transtendinous, or lateral parapatellar) approach. Main Outcome Measurements: Acute knee sepsis, deep/superficial infection, reoperation, and nonunion. Results: A total of 293 patients with 295 fractures met inclusion criteria (75% male, median age 41 years, 28% active smokers). Ninety fractures underwent intra-articular nailing, and 205 underwent extra-articular nailing. There were no differences in injury energy, Gustilo–Anderson classification, or rates of external fixation between groups. Acute knee sepsis occurred in one patient (1.1%) in the intra-articular group and one patient (0.5%) in the extra-articular group. Deep infection occurred in 8.9% for intra-articular and 9.3% for extra-articular ( P > 0.999), and aseptic nonunion in 8% vs 7%, respectively ( P > 0.999). Conclusions: Acute knee sepsis after intramedullary nailing of open tibial shaft fractures was rare (0.7%). Knee sepsis was more common after suprapatellar nailing than extra-articular approaches (1.1% vs 0.5%), but the results are not statistically significant, and the study lacks power to draw definitive conclusions about relative risk with such low base rates. These findings may assist surgeons with approach selection and patient counseling, taking into account injury characteristics and technical considerations related to the procedure that are case-specific.
- 5 August 2026
- Published by Wolters Kluwer Health in Techniques in Orthopaedics
- Vol. 41 (4)
Favorable Results Following Patella Fracture Fixation With 2.7 mm Variable Angle Locking Plates: A Technical Note and Case Series
Introduction: The primary objective of this study was to describe a technique using a 2.7 mm variable-angle (VA) locking plate fixation in combination with ex situ and in situ plate contouring, a high screw density, a “homerun” screw, and routine postoperative immobilization to obtain reliable outcomes following patella fractures. The secondary objectives were to determine the rate of postoperative complications and the range of motion at final follow-up, as well as the time to weight-bearing as tolerated and the time to range-of-motion as tolerated. Methods: All consecutive adult patients treated with a 2.7 mm VA locking plate for a patella fracture (AO/OTA 34) between January 2021 and January 2025 were retrospectively identified from one Level 1 trauma center. The use of 2.7 mm VA locking plates and augmented fixation was determined through operative reports and radiographs. Results: Thirty-seven patients treated with the technique were identified. One patient (2.7%, 95% CI: 0.07%-14%) experienced construct failure, and 4 patients (11%, 95% CI: 3.0%-25%) returned to the operating room (2 manipulations under anesthesia, 1 intra-articular screw removal, and 1 symptomatic hardware removal). No patients experienced infection or nonunion. At final orthopedic follow-up, the median RUST score was 12/12 (IQR=11 to 12). Conclusions: The described technique resulted in low rates of loss of fixation, implant failure, and removal of symptomatic implants, as well as reliable healing, following patella fracture fixation with a 2.7 mm VA locking plate.
- 5 August 2026
- Published by Wolters Kluwer Health in Techniques in Orthopaedics
- Vol. 41 (4)
Favorable Results Following Patella Fracture Fixation With 2.7 mm Variable Angle Locking Plates: A Technical Note and Case Series
Introduction: The primary objective of this study was to describe a technique using a 2.7 mm variable-angle (VA) locking plate fixation in combination with ex situ and in situ plate contouring, a high screw density, a “homerun” screw, and routine postoperative immobilization to obtain reliable outcomes following patella fractures. The secondary objectives were to determine the rate of postoperative complications and the range of motion at final follow-up, as well as the time to weight-bearing as tolerated and the time to range-of-motion as tolerated. Methods: All consecutive adult patients treated with a 2.7 mm VA locking plate for a patella fracture (AO/OTA 34) between January 2021 and January 2025 were retrospectively identified from one Level 1 trauma center. The use of 2.7 mm VA locking plates and augmented fixation was determined through operative reports and radiographs. Results: Thirty-seven patients treated with the technique were identified. One patient (2.7%, 95% CI: 0.07%-14%) experienced construct failure, and 4 patients (11%, 95% CI: 3.0%-25%) returned to the operating room (2 manipulations under anesthesia, 1 intra-articular screw removal, and 1 symptomatic hardware removal). No patients experienced infection or nonunion. At final orthopedic follow-up, the median RUST score was 12/12 (IQR=11 to 12). Conclusions: The described technique resulted in low rates of loss of fixation, implant failure, and removal of symptomatic implants, as well as reliable healing, following patella fracture fixation with a 2.7 mm VA locking plate.
- 1 May 2026
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 40 (5) , 237-244
Are 6- to 12-Week Radiographic Union Scores Associated With Healing After Lateral Locked Plating of Distal Femur Fractures?
OBJECTIVES: To determine whether 6–12 weeks modified Radiographic Union Score for Tibial fractures (mRUST) scores after lateral locked plating (LLP) of distal femur fractures were associated with nonunion versus healing. METHODS: Design: Retrospective case–control study. Setting: Two Level 1 Trauma Centers. Patient Selection Criteria: Included were adult patients with distal femur fractures (OTA/AO 33A/C) treated with LLP between 2006 and 2024 and with available postoperative radiographs between 6 and 12 weeks. Nonunion cases were defined as patients undergoing reoperation for nonunion after 12 weeks and were randomly matched 1:2 to controls, defined as those not undergoing reoperation for nonunion and with documented healing or an mRUST score of ≥12 at final follow-up. Outcome Measures and Comparisons: Total mRUST (scale: 4–16) and combined medial and posterior mRUST (scale: 2-8) scores were compared between nonunion cases and controls. Associations of mRUST scores with nonunion versus healing were estimated using logistic regression with adjustment for sampling distribution and time from surgery to mRUST assessment. RESULTS: Thirty distal femur nonunion cases and 60 controls were included (median ages 58 and 63 years; with 70% and 67% women, respectively). The median total mRUST score was 6 (interquartile range 6–7) for nonunion cases and 10 (interquartile range 8–11) for controls ( P < 0.001). Each 1-point increase in mRUST score was associated with a 57% reduction in odds of nonunion (odds ratio: 0.43, 95% confidence interval: 0.24–0.66; area under the curve 0.91). For the combined medial and posterior cortex scores, each 1-point increase was associated with a 70% reduction in odds of nonunion (odds ratio: 0.30, 95% confidence interval: 0.12–0.61; area under the curve 0.84). CONCLUSIONS: mRUST scores between 6 and 12 weeks demonstrated strong association with nonunion versus healing after LLP of distal femur fractures. This was consistent in analysis limited to medial and posterior cortices, although wide confidence intervals suggest imprecision in the effect estimate. Early mRUST assessment may serve as a helpful adjunct to support clinical decision making and patient counseling after LLP of distal femur fractures. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
- 1 May 2026
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 40 (5) , 237-244
Are 6- to 12-Week Radiographic Union Scores Associated With Healing After Lateral Locked Plating of Distal Femur Fractures?
OBJECTIVES: To determine whether 6–12 weeks modified Radiographic Union Score for Tibial fractures (mRUST) scores after lateral locked plating (LLP) of distal femur fractures were associated with nonunion versus healing. METHODS: Design: Retrospective case–control study. Setting: Two Level 1 Trauma Centers. Patient Selection Criteria: Included were adult patients with distal femur fractures (OTA/AO 33A/C) treated with LLP between 2006 and 2024 and with available postoperative radiographs between 6 and 12 weeks. Nonunion cases were defined as patients undergoing reoperation for nonunion after 12 weeks and were randomly matched 1:2 to controls, defined as those not undergoing reoperation for nonunion and with documented healing or an mRUST score of ≥12 at final follow-up. Outcome Measures and Comparisons: Total mRUST (scale: 4–16) and combined medial and posterior mRUST (scale: 2-8) scores were compared between nonunion cases and controls. Associations of mRUST scores with nonunion versus healing were estimated using logistic regression with adjustment for sampling distribution and time from surgery to mRUST assessment. RESULTS: Thirty distal femur nonunion cases and 60 controls were included (median ages 58 and 63 years; with 70% and 67% women, respectively). The median total mRUST score was 6 (interquartile range 6–7) for nonunion cases and 10 (interquartile range 8–11) for controls ( P < 0.001). Each 1-point increase in mRUST score was associated with a 57% reduction in odds of nonunion (odds ratio: 0.43, 95% confidence interval: 0.24–0.66; area under the curve 0.91). For the combined medial and posterior cortex scores, each 1-point increase was associated with a 70% reduction in odds of nonunion (odds ratio: 0.30, 95% confidence interval: 0.12–0.61; area under the curve 0.84). CONCLUSIONS: mRUST scores between 6 and 12 weeks demonstrated strong association with nonunion versus healing after LLP of distal femur fractures. This was consistent in analysis limited to medial and posterior cortices, although wide confidence intervals suggest imprecision in the effect estimate. Early mRUST assessment may serve as a helpful adjunct to support clinical decision making and patient counseling after LLP of distal femur fractures. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
- 1 February 2026
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 40 (2) , 75-81
Outcomes of Nonunion Surgery After Tibial Plateau Fractures: A Case Series of 28 Patients
OBJECTIVES: To evaluate outcomes of tibial plateau fracture nonunion surgery, including rates of final radiographic healing, additional surgery, and conversion to total knee arthroplasty (TKA). METHODS: Design: Retrospective case series. Setting: Two Level I academic trauma centers. Patients: Adult patients who underwent nonunion surgery after open reduction internal fixation of tibial plateau fractures (OTA/AO 41B-C) between 2000 and 2024 were included. Outcome Measures and Comparisons: The primary outcome was final radiographic healing. Secondary outcomes included additional surgery and conversion to TKA. RESULTS: Twenty-eight patients were included (median age 55 years (IQR: 38–61), 57% male). The median follow-up from the date of the nonunion surgery was 19 months (IQR:13–33). Twenty-one (75%) fractures were classified as Schatzker VI. Nonunion surgery involved revision open reduction internal fixation in 23 (82%) cases, bone grafting alone (with or without hardware removal) in 3 (11%) cases, screw augmentation in 1 (3.6%) patient, and 1 patient (3.6%) underwent multistage treatment, ending with definitive treatment using an Ilizarov frame for 6 months. Overall, 54% of patients received bone grafting to address bone defects. Radiographic healing was achieved in 24 patients (86%). All 4 (14%) patients with a persistent nonunion had Schatzker VI fractures. Of these, 3 (75%) ultimately underwent conversion to TKA, whereas 1 had no further surgery until the last follow-up 12.4 months after the initial procedure. Overall, 13 (46%) patients required additional surgery, of which 5 (18%) underwent TKA at a median of 3.1 years (IQR: 1.68–6.74). CONCLUSION: In the current study of patients who underwent tibial plateau fracture nonunion surgery, 86% of patients ultimately achieved radiographic healing, with 71% healed after the index nonunion surgery. Close to half of the patients required additional surgery, with 14% who underwent further procedures to achieve healing, and 18% ultimately required conversion to TKA. These findings can help surgeons counsel patients and guide expectations after surgery for tibial plateau fracture nonunion. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
- 1 February 2026
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 40 (2) , 75-81
Outcomes of Nonunion Surgery After Tibial Plateau Fractures: A Case Series of 28 Patients
OBJECTIVES: To evaluate outcomes of tibial plateau fracture nonunion surgery, including rates of final radiographic healing, additional surgery, and conversion to total knee arthroplasty (TKA). METHODS: Design: Retrospective case series. Setting: Two Level I academic trauma centers. Patients: Adult patients who underwent nonunion surgery after open reduction internal fixation of tibial plateau fractures (OTA/AO 41B-C) between 2000 and 2024 were included. Outcome Measures and Comparisons: The primary outcome was final radiographic healing. Secondary outcomes included additional surgery and conversion to TKA. RESULTS: Twenty-eight patients were included (median age 55 years (IQR: 38–61), 57% male). The median follow-up from the date of the nonunion surgery was 19 months (IQR:13–33). Twenty-one (75%) fractures were classified as Schatzker VI. Nonunion surgery involved revision open reduction internal fixation in 23 (82%) cases, bone grafting alone (with or without hardware removal) in 3 (11%) cases, screw augmentation in 1 (3.6%) patient, and 1 patient (3.6%) underwent multistage treatment, ending with definitive treatment using an Ilizarov frame for 6 months. Overall, 54% of patients received bone grafting to address bone defects. Radiographic healing was achieved in 24 patients (86%). All 4 (14%) patients with a persistent nonunion had Schatzker VI fractures. Of these, 3 (75%) ultimately underwent conversion to TKA, whereas 1 had no further surgery until the last follow-up 12.4 months after the initial procedure. Overall, 13 (46%) patients required additional surgery, of which 5 (18%) underwent TKA at a median of 3.1 years (IQR: 1.68–6.74). CONCLUSION: In the current study of patients who underwent tibial plateau fracture nonunion surgery, 86% of patients ultimately achieved radiographic healing, with 71% healed after the index nonunion surgery. Close to half of the patients required additional surgery, with 14% who underwent further procedures to achieve healing, and 18% ultimately required conversion to TKA. These findings can help surgeons counsel patients and guide expectations after surgery for tibial plateau fracture nonunion. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
- 24 May 2025
- Published by Springer Nature
- p. 651-662
Surgical Fixation of Vancouver B1 and B2 Periprosthetic Femur Fractures
- 24 May 2025
- Published by Springer Nature
- p. 651-662
Surgical Fixation of Vancouver B1 and B2 Periprosthetic Femur Fractures
- 24 May 2025
- Published by Springer Nature
- p. 383-397
Native Hip Dislocations
- 7 January 2025
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 145 (1) , 1-9
Fracture characteristics and functional outcomes for Schatzker V/VI bicondylar tibial plateau fractures with a separate tubercle fragment: a comparative study
Introduction A separate tibial tubercle fragment (TF) is found in up to half of all bicondylar tibial plateau (BTP) fractures. Adequate healing of the TF is required to reconstitute the extensor mechanism of the knee. The purpose of this study was to compare outcomes after surgical fixation of BTP fractures with and without a TF. Materials and methods Retrospective comparative study of adult patients undergoing open reduction internal fixation (ORIF) of a Schatzker V/VI BTP fracture at two Level 1 trauma centers. Primary outcomes were patient-reported outcomes as assessed by the PROMIS Physical Function (PF) score and EQ-5D-3L. Secondary outcomes included rates of infection, reoperation, and nonunion. Patient demographics, fracture characteristics, and outcomes were compared for patients with and without a TF. Results 189 patients (mean follow-up 8.1 yrs) were included. 55 patients (29%) had a separate TF. There was no significant difference in PROMIS PF (48.1 vs 47.5, p = 0.45) or EQ-5D-3L scores (0.82 vs 0.83, p = 0.32) between patients with and without a separate tubercle fragment.Patients with a TF had more open fractures (16% vs 5%, p = 0.02) and high energy injuries (66% vs 49%, p = 0.03).There was no significant difference in the rates of deep infection (15% vs 8%, p = 0.19) or unplanned reoperation (23% vs 13%, p = 0.09). There were more nonunions in the TF group (11% vs 2%, p = 0.02) but only two involved the tubercle fragment. Conclusion In this comparative study, the presence of a TF did not portend a worse functional outcome for patients with a healed fracture. Rates of open fracture and high energy mechanism of injury were significantly higher in the TF group.. Surgeons should be aware that a separate TF may indicate a more severe injury. More studies are needed to determine whether the presence of a TF is associated with higher complication rates.
- 7 January 2025
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 145 (1) , 1-9
Fracture characteristics and functional outcomes for Schatzker V/VI bicondylar tibial plateau fractures with a separate tubercle fragment: a comparative study
Introduction A separate tibial tubercle fragment (TF) is found in up to half of all bicondylar tibial plateau (BTP) fractures. Adequate healing of the TF is required to reconstitute the extensor mechanism of the knee. The purpose of this study was to compare outcomes after surgical fixation of BTP fractures with and without a TF. Materials and methods Retrospective comparative study of adult patients undergoing open reduction internal fixation (ORIF) of a Schatzker V/VI BTP fracture at two Level 1 trauma centers. Primary outcomes were patient-reported outcomes as assessed by the PROMIS Physical Function (PF) score and EQ-5D-3L. Secondary outcomes included rates of infection, reoperation, and nonunion. Patient demographics, fracture characteristics, and outcomes were compared for patients with and without a TF. Results 189 patients (mean follow-up 8.1 yrs) were included. 55 patients (29%) had a separate TF. There was no significant difference in PROMIS PF (48.1 vs 47.5, p = 0.45) or EQ-5D-3L scores (0.82 vs 0.83, p = 0.32) between patients with and without a separate tubercle fragment.Patients with a TF had more open fractures (16% vs 5%, p = 0.02) and high energy injuries (66% vs 49%, p = 0.03).There was no significant difference in the rates of deep infection (15% vs 8%, p = 0.19) or unplanned reoperation (23% vs 13%, p = 0.09). There were more nonunions in the TF group (11% vs 2%, p = 0.02) but only two involved the tubercle fragment. Conclusion In this comparative study, the presence of a TF did not portend a worse functional outcome for patients with a healed fracture. Rates of open fracture and high energy mechanism of injury were significantly higher in the TF group.. Surgeons should be aware that a separate TF may indicate a more severe injury. More studies are needed to determine whether the presence of a TF is associated with higher complication rates.