Hee Jin Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hee Jin Kim has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Chun Gyoo Ihm
2 shared publicationsMyung Jae Kim
2 shared publicationsTab Won Lee
Division of Nephrology, Department of Internal Medicine, Kyung Hee University Medical Centre, Seoul, Korea
1 shared publicationTae Won Lee
1 shared publication
Latest Publications
- 7 October 2002
- Published by S. Karger AG in American Journal of Nephrology
- Vol. 22 (5-6) , 532-538
Use of Fluoroscopy-Guided Wire Manipulation and/or Laparoscopic Surgery in the Repair of Malfunctioning Peritoneal Dialysis Catheters
Background: Peritoneal catheter is the lifeline for the continuous ambulatory peritoneal dialysis (CAPD) patients. Over the years, obstruction or displacement of the CAPD catheter has been one of the common complications of CAPD. Fluoroscopy-guided wire manipulation or laparoscopic surgery has been developed to manage outflow obstruction. We analyzed the catheter outcome of fluoroscopy-guided wire manipulation or laparoscopic surgery to determine the ultimate benefit of these procedures. Methods: From June 1996 to August 2000, catheter complications were manipulated in 24 patients. Eleven (46%) of these patients were initially managed by guide wire under fluoroscopic control. The remaining 13 (54%) patients were manipulated by laparoscopic surgery. A successful outcome was defined as maintained normal peritoneal catheter function at 30 days after the manipulations. Among the catheters manipulated, 18 (75%) were inserted by nephrologist and 6 (25%) by surgeons at the initiation of CAPD. Tenckhoff double-cuff peritoneal catheters were inserted to all patients. Results: The time elapsed between catheter insertion and manipulation varied from 1 to 60 days with a mean of 11 days. The primary causes of catheter malfunction were kinking in 1 case, omental wrapping with adhesions in 9 cases, and catheter displacements in the remaining 14 cases. Thirty-day catheter function was achieved in 50% (12/24) of initial catheter manipulations, with guide wire under fluoroscopic control (46%, 5/11) and laparoscopic surgery (54%, 7/13). Overall success rate of repeated manipulation was 71% (17 of 24). Conclusion: The successful outcome in repairing of the malfunctioning CAPD catheters could be increased by the combination of fluoroscopy-guided wire manipulation and laparoscopic surgery.
- 7 October 2002
- Published by S. Karger AG in American Journal of Nephrology
- Vol. 22 (5-6) , 532-538
Use of Fluoroscopy-Guided Wire Manipulation and/or Laparoscopic Surgery in the Repair of Malfunctioning Peritoneal Dialysis Catheters
Background: Peritoneal catheter is the lifeline for the continuous ambulatory peritoneal dialysis (CAPD) patients. Over the years, obstruction or displacement of the CAPD catheter has been one of the common complications of CAPD. Fluoroscopy-guided wire manipulation or laparoscopic surgery has been developed to manage outflow obstruction. We analyzed the catheter outcome of fluoroscopy-guided wire manipulation or laparoscopic surgery to determine the ultimate benefit of these procedures. Methods: From June 1996 to August 2000, catheter complications were manipulated in 24 patients. Eleven (46%) of these patients were initially managed by guide wire under fluoroscopic control. The remaining 13 (54%) patients were manipulated by laparoscopic surgery. A successful outcome was defined as maintained normal peritoneal catheter function at 30 days after the manipulations. Among the catheters manipulated, 18 (75%) were inserted by nephrologist and 6 (25%) by surgeons at the initiation of CAPD. Tenckhoff double-cuff peritoneal catheters were inserted to all patients. Results: The time elapsed between catheter insertion and manipulation varied from 1 to 60 days with a mean of 11 days. The primary causes of catheter malfunction were kinking in 1 case, omental wrapping with adhesions in 9 cases, and catheter displacements in the remaining 14 cases. Thirty-day catheter function was achieved in 50% (12/24) of initial catheter manipulations, with guide wire under fluoroscopic control (46%, 5/11) and laparoscopic surgery (54%, 7/13). Overall success rate of repeated manipulation was 71% (17 of 24). Conclusion: The successful outcome in repairing of the malfunctioning CAPD catheters could be increased by the combination of fluoroscopy-guided wire manipulation and laparoscopic surgery.
- 1 August 2002
- Published by Wiley in Nephrology
- Vol. 7 (4) , 198-204
Prevalence of cancers in Korean recipients of renal transplants
SUMMARY:Cancer is a complication in immunosuppressed transplant recipients, and is widely recognized. of the 10 029 Korean recipients of renal transplants in 1975–1999, cancer developed in 193 (1.9%). the total number of cancers was 197, with four patients developing two cancers. Only the patients with cancers were reviewed according to their age, sex, type of immunosuppression, interval between transplantation and the diagnosis of cancer, and the method of treatment and survival. In 108 males and 85 females (mean age 40.7 years), cancer developed approximately 64.9 months after renal transplantation. Eighteen patients received conventional immunosuppression‐azathioprine with prednisone, and another 175 patients received cyclosporin‐containing immunosuppression therapy. Twenty‐two patients had skin cancers, 21 patients had Kaposi's sarcoma, 17 patients had post‐transplantation lymphoproliferative disorder, two patients had myelodysplastic syndrome, and 132 patients had solid cancers, respectively. One hundred and nine patients underwent surgical treatment; 88 patients with advanced disease received radiotherapy, chemotherapy or symptomatic therapy. One hundred and twenty‐one (62.7%) patients are alive, with no evidence of disease 42.2 months (on average) following the diagnosis of cancer. Another 11 patients were lost to follow up. Forty‐nine patients died of progressive malignant disease, and 12 died of other causes. the average survival of dead patients with cancers was approximately 9 months (the mean survival period of dead patients caused by progressive malignant disease was 7.7 months). the time of diagnosis of cancers ranged from 2 to 240 months after kidney transplantation. We conclude that in immunosuppressed renal transplant recipients, the possibility of the development of cancer always should be considered. and we recommend follow up of appropriate intervals for signs of cancer over a long period.
- 1 August 2002
- Published by Wiley in Nephrology
- Vol. 7 (4) , 198-204
Prevalence of cancers in Korean recipients of renal transplants
SUMMARY:Cancer is a complication in immunosuppressed transplant recipients, and is widely recognized. of the 10 029 Korean recipients of renal transplants in 1975–1999, cancer developed in 193 (1.9%). the total number of cancers was 197, with four patients developing two cancers. Only the patients with cancers were reviewed according to their age, sex, type of immunosuppression, interval between transplantation and the diagnosis of cancer, and the method of treatment and survival. In 108 males and 85 females (mean age 40.7 years), cancer developed approximately 64.9 months after renal transplantation. Eighteen patients received conventional immunosuppression‐azathioprine with prednisone, and another 175 patients received cyclosporin‐containing immunosuppression therapy. Twenty‐two patients had skin cancers, 21 patients had Kaposi's sarcoma, 17 patients had post‐transplantation lymphoproliferative disorder, two patients had myelodysplastic syndrome, and 132 patients had solid cancers, respectively. One hundred and nine patients underwent surgical treatment; 88 patients with advanced disease received radiotherapy, chemotherapy or symptomatic therapy. One hundred and twenty‐one (62.7%) patients are alive, with no evidence of disease 42.2 months (on average) following the diagnosis of cancer. Another 11 patients were lost to follow up. Forty‐nine patients died of progressive malignant disease, and 12 died of other causes. the average survival of dead patients with cancers was approximately 9 months (the mean survival period of dead patients caused by progressive malignant disease was 7.7 months). the time of diagnosis of cancers ranged from 2 to 240 months after kidney transplantation. We conclude that in immunosuppressed renal transplant recipients, the possibility of the development of cancer always should be considered. and we recommend follow up of appropriate intervals for signs of cancer over a long period.