XMXavier Martínez-Lladó

Xavier Martínez-Lladó

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xavier Martínez-Lladó has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Novel Oxidation Strategies for the In Situ Remediation of Chlorinated Solvents from Groundwater—A Bench-Scale Study

    by Alicia Cano-López, Lidia Fernandez-Rojo, Leónidas Pérez-Estrada, Sònia Jou-Claus, Marta Batriu, Carme Bosch, Xavier Martínez-Lladó, Joana Baeta Trias, Ricard Mora Vilamaña, Mònica Escolà Casas, et al.

    Industrial chlorinated solvents continue to be among the most significant issues in groundwater (GW) pollution worldwide. This study assesses the effectiveness of eight novel oxidation treatments, including persulfate (PS), ferrous sulfate, sulfidated nano-zero valent iron (S-nZVI), and potassium ferrate, along with their combinations, for the potential in situ remediation of GW polluted with chlorinated solvents (1,2-dichloroethylene, trichloroethylene, and tetrachloroethylene). Our bench-scale results reveal that the combined addition of PS and S-nZVI can effectively eliminate trichloroethylene (10 µg/L), achieving removal rates of up to 80% and 92% within 1 h, respectively, when using synthetic GW. In the case of real GW, this combination achieved removal rates of 69, 99, and 92% for cis-1,2-dichloroethylene, trichloroethylene, and tetrachloroethylene, respectively, within 24 h. Therefore, this proposed remediation solution resulted in a significant reduction in the environmental risk quotient, shifting it from a high-risk (1.1) to a low-risk (0.2) scenario. Furthermore, the absence of transformation products, such as vinyl chloride, suggests the suitability of employing this solution for the in situ remediation of GW polluted with chlorinated solvents.


  • Open Access

    Improvement in Arsenic Adsorption and Calcite Dissolution Kinetics through Size Reduction of a Ferric Hydroxide-Calcite Adsorbent

    by Lidia Fernandez-Rojo, Vicenç Martí, Irene Jubany, Neus Bahí, Marcel Janer, Xavier Martínez-Lladó, Miquel Rovira

    The employment of granular ferric iron-(oxy)hydroxides, a well-known economic and effective method, lowers arsenic concentrations in different water types. However, for direct application in polluted groundwaters, there is a need to develop new injectable adsorbents for aquifers that could also neutralize acidic media. In this context, a granular ferric hydroxide-calcite (GFH-C) adsorbent was size-reduced to 0.4–50 µm by sonication with the aim of improving (i) the adsorption of As(III) and As(V) at different pHs and (ii) the pH control through the dissolution of calcite. Batch experiments were conducted to determine As(III) and As(V) adsorption isotherms and kinetics, as well as calcite dissolution kinetics, using GFH-C of two sizes (granular and sonicated). Results showed that the arsenic binding capacity of sonicated adsorbents did not improve significantly. On the contrary, the As(III) and As(V) adsorption kinetics improved with the sonication, as in the case of calcite dissolution kinetics. The dissolution of calcite from the adsorbent made the water pH increase to around 9.2–9.4. The sonicated adsorbent offers an advantage in depolluting As-containing groundwater due to its smaller size, which is linked with faster arsenic adsorption and effective acidic water neutralization.


  • Open Access

    Chlorine Concentration Modelling and Supervision in Water Distribution Systems

    by Ramon Pérez, Albert Martínez-Torrents, Manuel Martínez, Sergi Grau, Laura Vinardell, Ricard Tomàs, Xavier Martínez-Lladó, Irene Jubany

    The quality of the drinking water distributed through the networks has become the main concern of most operators. This work focuses on one of the most important variables of the drinking water distribution networks (WDN) that use disinfection, chlorine. This powerful disinfectant must be dosed carefully in order to reduce disinfection byproducts (DBPs). The literature demonstrates researchers’ interest in modelling chlorine decay and using several different approaches. Nevertheless, the full-scale application of these models is far from being a reality in the supervision of water distribution networks. This paper combines the use of validated chlorine prediction models with an intensive study of a large amount of data and its influence on the model’s parameters. These parameters are estimated and validated using data coming from the Supervisory Control and Data Acquisition (SCADA) software, a full-scale water distribution system, and using off-line analytics. The result is a powerful methodology for calibrating a chlorine decay model on-line which coherently evolves over time along with the significant variables that influence it.


  • Open Access

    Erythromycin Abatement from Water by Electro-Fenton and Peroxyelectrocoagulation Treatments

    by Anna Serra-Clusellas, Luca Sbardella, Pol Herrero, Antoni Delpino-Rius, Marc Riu, María de Lourdes Correa, Anna Casadellà, Núria Canela, Xavier Martínez-Lladó

    Electro-Fenton (EF) and peroxyelectrocoagulation (PEC) processes were investigated to mineralize 10 mg L−1 erythromycin from ultrapure water, evaluating the influence of the anode material (BDD and Fe), current density (janode) (5 mA cm−2 and 10 mA cm−2), oxygen flowrate injected to the cathode (0.8 L min−1 O2 and 2.0 L min−1 O2) and pH (2.8, 5.0 and 7.0) on the process efficiency and the electricity costs. 70% mineralization was reached after applying 0.32 A h L−1 under the best operational conditions: PEC treatment at 5 mA cm−2, 2.0 L min−1 O2 and pH 2.8. The electricity consumption of the electrochemical cell under these conditions was approximately 0.3 kWh m−3. Early-stage intermediates produced from erythromycin degradation were identified and quantified throughout the treatment and a potential erythromycin degradation pathway was proposed. The most appropriate operational conditions tested with synthetic solutions were applied to treat a real effluent from the tertiary treatment of an urban wastewater treatment plant. All emerging compounds listed in the EU Decision 2018/840 (Watch List 2018) were determined before and after the PEC treatment. All listed pollutants were degraded below their quantification limit, except estrone and 17-α-ethinylestradiol which were 99% removed from water. Electricity consumption of the electrochemical cell was 0.4 kWh m−3. Whilst awaiting future results that demonstrate the innocuity of the generated byproducts, the results of this investigation (high removal yields for emerging pollutants together with the low electricity consumption of the cell) indicate the promising high potential of PEC treatment as a water treatment/remediation/regeneration technology.


  • Open Access

    Forward Osmosis as Concentration Process: Review of Opportunities and Challenges

    by Gaetan Blandin, Federico Ferrari, Geoffroy Lesage, Pierre Le-Clech, Marc Héran, Xavier Martinez-Lladó

    In the past few years, osmotic membrane systems, such as forward osmosis (FO), have gained popularity as “soft” concentration processes. FO has unique properties by combining high rejection rate and low fouling propensity and can be operated without significant pressure or temperature gradient, and therefore can be considered as a potential candidate for a broad range of concentration applications where current technologies still suffer from critical limitations. This review extensively compiles and critically assesses recent considerations of FO as a concentration process for applications, including food and beverages, organics value added compounds, water reuse and nutrients recovery, treatment of waste streams and brine management. Specific requirements for the concentration process regarding the evaluation of concentration factor, modules and design and process operation, draw selection and fouling aspects are also described. Encouraging potential is demonstrated to concentrate streams more than 20-fold with high rejection rate of most compounds and preservation of added value products. For applications dealing with highly concentrated or complex streams, FO still features lower propensity to fouling compared to other membranes technologies along with good versatility and robustness. However, further assessments on lab and pilot scales are expected to better define the achievable concentration factor, rejection and effective concentration of valuable compounds and to clearly demonstrate process limitations (such as fouling or clogging) when reaching high concentration rate. Another important consideration is the draw solution selection and its recovery that should be in line with application needs (i.e., food compatible draw for food and beverage applications, high osmotic pressure for brine management, etc.) and be economically competitive.