Mijin Choi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mijin Choi has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Thomas S. Giugliano
Department of Prosthodontics New York University College of Dentistry New York New York USA
2 shared publications - Altair Antoninha Del Bel Cury
State University of Campinas
1 shared publication Ann Marie Pereira
Department of Prosthodontics, Nova Southeastern University College of Dental Medicine, Fort Lauderdale, FL
1 shared publicationChek Hai Lim
Laboratories for Microstructure Physics & Mechanics of Materials Department of Preventive and Restorative Sciences School of Dental Medicine University of Pennsylvania Philadelphia Pennsylvania USA
1 shared publication- Chek Hai Lim
School of Dental Medicine, University of Pennsylvania, 240 S. 40th St., Philadelphia, PA 19104, USA
1 shared publication Francis Tung
Associate Professor, Louis Blatterfein Department of Prosthodontics, New York University College of Dentistry, New York, NY
1 shared publication
Latest Publications
- Open Access
- 10 April 2025
- Published by Elsevier in Dental Materials
- Vol. 41 (6) , 690-698
Balancing strength and translucency: The role of microstructure in additive and subtractive dental zirconia
- 10 April 2025
- Published by Elsevier in Dental Materials
- Vol. 41 (6) , 690-698
Open AccessBalancing strength and translucency: The role of microstructure in additive and subtractive dental zirconia
- 1 November 2023
- Published by Wiley in Journal of Prosthodontics
- Vol. 33 (9) , 891-898
In vitro comparison of physical characteristics of milled versus printed zirconia discs
Purpose: The purpose of this study was to compare the dimensional accuracy, translucency, and biaxial flexural strength of milled zirconia (MZ) versus 3D‐printed zirconia (PZ) discs.Materials & Methods: A circular disc measuring 14.0 mm in diameter and 1.20 mm in thickness was designed using computer‐aided design (CAD) software. The resulting standard tessellation language (STL) file was used both as a control and to fabricate 36 zirconia (3Y‐TZP) disc specimens (n = 36): 18 were milled (group MZ) and 18 were 3D‐printed (group PZ). The diameter and thickness of each disc were measured using a digital caliper. Translucency was evaluated using a calibrated dental colorimeter. The flexural strength was determined using the piston‐on‐three‐ball biaxial flexure test. All measurements were done by one blinded examiner. The statistical significance level was set to α = 0.05.Results: The MZ discs had significantly more accurate dimensions than the PZ discs in both diameter and thickness when compared to the control CAD software‐designed disc. The MZ discs exhibited significantly higher translucency (translucency parameter (TP) = 16.95 ±0.36 vs. 9.24 ±1.98) and biaxial flexural strength (996.16 ±137.37 MPa vs. 845.75 ±266.16 MPa) than the PZ discs. Finally, MZ possessed a significantly higher Weibull modulus relative to PZ.Conclusions: The results showed that the milled specimens achieved better dimensional accuracy and were more translucent, stronger, and less prone to failure than printed specimens.
- 1 November 2023
- Published by Wiley in Journal of Prosthodontics
- Vol. 33 (9) , 891-898
In vitro comparison of physical characteristics of milled versus printed zirconia discs
Purpose: The purpose of this study was to compare the dimensional accuracy, translucency, and biaxial flexural strength of milled zirconia (MZ) versus 3D‐printed zirconia (PZ) discs.Materials & Methods: A circular disc measuring 14.0 mm in diameter and 1.20 mm in thickness was designed using computer‐aided design (CAD) software. The resulting standard tessellation language (STL) file was used both as a control and to fabricate 36 zirconia (3Y‐TZP) disc specimens (n = 36): 18 were milled (group MZ) and 18 were 3D‐printed (group PZ). The diameter and thickness of each disc were measured using a digital caliper. Translucency was evaluated using a calibrated dental colorimeter. The flexural strength was determined using the piston‐on‐three‐ball biaxial flexure test. All measurements were done by one blinded examiner. The statistical significance level was set to α = 0.05.Results: The MZ discs had significantly more accurate dimensions than the PZ discs in both diameter and thickness when compared to the control CAD software‐designed disc. The MZ discs exhibited significantly higher translucency (translucency parameter (TP) = 16.95 ±0.36 vs. 9.24 ±1.98) and biaxial flexural strength (996.16 ±137.37 MPa vs. 845.75 ±266.16 MPa) than the PZ discs. Finally, MZ possessed a significantly higher Weibull modulus relative to PZ.Conclusions: The results showed that the milled specimens achieved better dimensional accuracy and were more translucent, stronger, and less prone to failure than printed specimens.
- Open Access
- 31 December 2020
- Published by The Korean Society for Aviation and Aeronautics in Journal of the Korean Society for Aviation and Aeronautics
- Vol. 28 (4) , 55-62
A Study on Experimental Special Airworthiness Certification for Unmanned Aircraft Systems
한국항공운항학회지(Journal of the Korean Society for Aviation and Aeronautics)
- 31 December 2020
- Published by The Korean Society for Aviation and Aeronautics in Journal of the Korean Society for Aviation and Aeronautics
- Vol. 28 (4) , 55-62
Open AccessA Study on Experimental Special Airworthiness Certification for Unmanned Aircraft Systems
한국항공운항학회지(Journal of the Korean Society for Aviation and Aeronautics)
- 3 May 2019
- Published by Wiley in Journal of Prosthodontics
- Vol. 28 (6) , 607-612
Management of Amelogenesis Imperfecta in Adolescent Patients: Clinical Report
The oral rehabilitation of adolescent patients with amelogenesis imperfecta (AI) is complex due to the presence of mixed dentition with altered eruption sequence. In this article, the interdisciplinary treatment approach for adolescent patients with AI is discussed. The types and timing of treatments at various stages of growth are described through a literature review on this topic. AI is an inherited condition that disturbs the development of the enamel structure. Because of the presence of mixed dentition, definitive treatment options often have to be delayed until eruption of permanent dentition is complete, requiring careful treatment coordination and proper sequencing between different dental disciplines starting at a young age. Adolescent patients require prosthodontic treatment design that can be adapted to the changes in arch shapes, sizes, interarch relationship, and esthetic needs. AI patients are often challenged with both excessive and limited restorative spaces within the same arch due to the abnormal growth patterns, enamel structure, tooth size, and tooth shape. Therefore, careful determination of the required restorative space is critical to ensure optimal prognosis. This clinical report discusses treatment recommendations, timing of various treatment modalities, and involvement of appropriate interdisciplinary teams for managing adolescent patients.
- 3 May 2019
- Published by Wiley in Journal of Prosthodontics
- Vol. 28 (6) , 607-612
Management of Amelogenesis Imperfecta in Adolescent Patients: Clinical Report
The oral rehabilitation of adolescent patients with amelogenesis imperfecta (AI) is complex due to the presence of mixed dentition with altered eruption sequence. In this article, the interdisciplinary treatment approach for adolescent patients with AI is discussed. The types and timing of treatments at various stages of growth are described through a literature review on this topic. AI is an inherited condition that disturbs the development of the enamel structure. Because of the presence of mixed dentition, definitive treatment options often have to be delayed until eruption of permanent dentition is complete, requiring careful treatment coordination and proper sequencing between different dental disciplines starting at a young age. Adolescent patients require prosthodontic treatment design that can be adapted to the changes in arch shapes, sizes, interarch relationship, and esthetic needs. AI patients are often challenged with both excessive and limited restorative spaces within the same arch due to the abnormal growth patterns, enamel structure, tooth size, and tooth shape. Therefore, careful determination of the required restorative space is critical to ensure optimal prognosis. This clinical report discusses treatment recommendations, timing of various treatment modalities, and involvement of appropriate interdisciplinary teams for managing adolescent patients.
- 1 January 2016
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 115 (1) , 123-128
Mandibular fibular graft reconstruction with CAD/CAM technology: A clinical report and literature review
- 1 January 2016
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 115 (1) , 123-128
Mandibular fibular graft reconstruction with CAD/CAM technology: A clinical report and literature review
- 1 July 2008
- Published by Wiley in Journal of Prosthodontics
- Vol. 17 (5) , 423-426
An Alternative Technique for Fabrication of an Occlusal Device
Several methods have been described for fabrication of occlusal devices, but many require complex and time-consuming laboratory procedures. In this article, an alternative fabrication method for a hard occlusal device while maintaining the articulation of the cast is described.
- 1 July 2008
- Published by Wiley in Journal of Prosthodontics
- Vol. 17 (5) , 423-426
An Alternative Technique for Fabrication of an Occlusal Device
Several methods have been described for fabrication of occlusal devices, but many require complex and time-consuming laboratory procedures. In this article, an alternative fabrication method for a hard occlusal device while maintaining the articulation of the cast is described.