Pulak Vatsya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pulak Vatsya has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Samarth Mittal
All India Institute of Medical Sciences, New Delhi, India
5 shared publications Vivek Trikha
Orthopaedics, All India Institute of Medical Sciences, New Delhi, Delhi, India
4 shared publications- Vivek Trikha
Department of Orthopaedics, JPNATC, AIIMS, New Delhi, India
4 shared publications Samarth Mittal
Orthopaedics, All India Institute of Medical Sciences, New Delhi, Delhi, India
3 shared publications- Bhavuk Garg
Department of Orthopaedics, All India Institute of Medical Sciences, New Delhi 110029, Delhi, India
2 shared publications - M. L. V. Sai Krishna
Department of Orthopaedics, Aayush Hospitals, Eluru, India
2 shared publications
Latest Publications
- 18 September 2023
- Published by BMJ in BMJ Case Reports
- Vol. 16 (9) , e252667
Management of long bone fractures in patients with pycnodysostosis
Pycnodysostosis is a rare genetic condition that leads to generalised bony sclerosis and increased fracture risk. Orthopaedic specialists play a crucial role in managing affected children due to their susceptibility to frequent fractures. We had a case of a middle childhood female patient with pycnodysostosis and a femur fracture. Initially, an attempt using the Titanium Elastic Nailing System was made, but the sclerotic metaphyseal bone made it challenging. So, we opted for a 4.5 mm locked compressive plate, with multiple drill bits as a backup due to potential drill breakage. Though elastic nailing is preferred for paediatric long bone fractures, surgeons must be prepared for extremely sclerotic cortices and a narrow medullary canal when dealing with patients with pycnodysostosis. Open fixation and multiple drill bits in the toolkit are essential to overcome the potential obstacles during the procedure.
- 18 September 2023
- Published by BMJ in BMJ Case Reports
- Vol. 16 (9) , e252667
Management of long bone fractures in patients with pycnodysostosis
Pycnodysostosis is a rare genetic condition that leads to generalised bony sclerosis and increased fracture risk. Orthopaedic specialists play a crucial role in managing affected children due to their susceptibility to frequent fractures. We had a case of a middle childhood female patient with pycnodysostosis and a femur fracture. Initially, an attempt using the Titanium Elastic Nailing System was made, but the sclerotic metaphyseal bone made it challenging. So, we opted for a 4.5 mm locked compressive plate, with multiple drill bits as a backup due to potential drill breakage. Though elastic nailing is preferred for paediatric long bone fractures, surgeons must be prepared for extremely sclerotic cortices and a narrow medullary canal when dealing with patients with pycnodysostosis. Open fixation and multiple drill bits in the toolkit are essential to overcome the potential obstacles during the procedure.
- 1 October 2022
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 12 (4)
Bilateral Nonunion of Femoral Neck Fractures Because of Nutritional Osteomalacia
Case: We report 2 cases of atraumatic, bilateral femoral neck fracture nonunions. Both the patients were relatively young and had underlying nutritional osteomalacia. In both cases, valgus intertrochanteric osteotomy was performed along with vitamin D and calcium supplementation. The patients were followed up for an average of 3 years and achieved bone union without any complications. Conclusion: Bilateral femoral neck fractures are rare, and bilateral nonunion of femoral neck fractures secondary to osteomalacia is even rarer. Valgus intertrochanteric osteotomy can salvage the hip. Correction of underlying osteomalacia by vitamin D and calcium supplementation preceeded surgical intervention in our cases.
- 1 October 2022
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 12 (4)
Bilateral Nonunion of Femoral Neck Fractures Because of Nutritional Osteomalacia
Case: We report 2 cases of atraumatic, bilateral femoral neck fracture nonunions. Both the patients were relatively young and had underlying nutritional osteomalacia. In both cases, valgus intertrochanteric osteotomy was performed along with vitamin D and calcium supplementation. The patients were followed up for an average of 3 years and achieved bone union without any complications. Conclusion: Bilateral femoral neck fractures are rare, and bilateral nonunion of femoral neck fractures secondary to osteomalacia is even rarer. Valgus intertrochanteric osteotomy can salvage the hip. Correction of underlying osteomalacia by vitamin D and calcium supplementation preceeded surgical intervention in our cases.
- 25 July 2022
- Published by Wolters Kluwer Health in Techniques in Orthopaedics
- Vol. 37 (4) , 253-257
“Turning The Tables”: A Technical Tip to Overcome Anatomic Constraints While Distal Locking During Femur Intramedullary Nailing
Introduction: Interlocking nailing for femoral shaft fractures is one of the most common surgeries by orthopedic traumatologists. With the advent of cephalon-medullary nailing, a center-center position of the head screw has become mandatory. With retroversion or reduced anteversion of neck, a center placement needs internal rotation of the nail. This makes distal locking problematic, as now making a perfect circle is difficult due to the physical constraints of C-arm rotation. Objective: To describe a novel technique to overcome the anatomic constraints and get a perfect circle for quick distal locking. Material and Methods: We used a novel technique in our routine femur nailing cases. Here, in cases with reduced anteversion of the neck, distal locking was tenuous due to difficulty in making a perfect circle. Thus, we have used a new technique called “Turning the table” where we externally rotate the table, which allows us to get a perfect circle for locking in almost a single exposure. Results: This is a useful technique in cases where getting a perfect circle is difficult due to anatomic constraints and variations and can help in getting a perfect circle with limited radiation exposure.
- 25 July 2022
- Published by Wolters Kluwer Health in Techniques in Orthopaedics
- Vol. 37 (4) , 253-257
“Turning The Tables”: A Technical Tip to Overcome Anatomic Constraints While Distal Locking During Femur Intramedullary Nailing
Introduction: Interlocking nailing for femoral shaft fractures is one of the most common surgeries by orthopedic traumatologists. With the advent of cephalon-medullary nailing, a center-center position of the head screw has become mandatory. With retroversion or reduced anteversion of neck, a center placement needs internal rotation of the nail. This makes distal locking problematic, as now making a perfect circle is difficult due to the physical constraints of C-arm rotation. Objective: To describe a novel technique to overcome the anatomic constraints and get a perfect circle for quick distal locking. Material and Methods: We used a novel technique in our routine femur nailing cases. Here, in cases with reduced anteversion of the neck, distal locking was tenuous due to difficulty in making a perfect circle. Thus, we have used a new technique called “Turning the table” where we externally rotate the table, which allows us to get a perfect circle for locking in almost a single exposure. Results: This is a useful technique in cases where getting a perfect circle is difficult due to anatomic constraints and variations and can help in getting a perfect circle with limited radiation exposure.
- Open Access
- 20 May 2022
- Published by Elsevier in Journal of Orthopaedic Reports
- Vol. 1 (3)
Double mattress fixation with a single knotless anchor in Bankart's repair- A novel technique
- 20 May 2022
- Published by Elsevier in Journal of Orthopaedic Reports
- Vol. 1 (3)
Open AccessDouble mattress fixation with a single knotless anchor in Bankart's repair- A novel technique
- 24 March 2022
- Published by Elsevier in Journal of Clinical Orthopaedics and Trauma
- Vol. 28, 101826
Lockdown imposition due to COVID-19 and its effect on orthopedic emergency department in level 1 trauma center in South Asia
- 24 March 2022
- Published by Elsevier in Journal of Clinical Orthopaedics and Trauma
- Vol. 28, 101826
Lockdown imposition due to COVID-19 and its effect on orthopedic emergency department in level 1 trauma center in South Asia
- 8 March 2022
- Published by BMJ in BMJ Case Reports
- Vol. 15 (3) , e247812
‘Extended tibia osteotomy’: a technical tip for removal of incarcerated reamer with broken guide wire bead during tibia nailing and literature review
Intramedullary nailing has become a standard of care for tibia fractures. Reaming is an essential part of this technique due to its multiple advantages like a better fit and earlier union. In young bone, with a narrow cortical canal, incarceration and breakage of reamer is a possibility. This can be removed with a ball-tip guidewire. In our case, the broken incarcerated reamer was complicated by a broken ball-tip of the guidewire, leading us to invent a novel medial tibial osteotomy window for the reamer removal. This can be a handy tool for a stuck surgeon intraoperatively.
- 8 March 2022
- Published by BMJ in BMJ Case Reports
- Vol. 15 (3) , e247812
‘Extended tibia osteotomy’: a technical tip for removal of incarcerated reamer with broken guide wire bead during tibia nailing and literature review
Intramedullary nailing has become a standard of care for tibia fractures. Reaming is an essential part of this technique due to its multiple advantages like a better fit and earlier union. In young bone, with a narrow cortical canal, incarceration and breakage of reamer is a possibility. This can be removed with a ball-tip guidewire. In our case, the broken incarcerated reamer was complicated by a broken ball-tip of the guidewire, leading us to invent a novel medial tibial osteotomy window for the reamer removal. This can be a handy tool for a stuck surgeon intraoperatively.
- Open Access
- 29 July 2021
- Published by Springer Nature in Cureus
- Vol. 13 (7)
Indigenous Proximal Femoral Nails and Their Novel Complications
Pertrochanteric fractures are one of the commonest fractures in the geriatric age group. Management of these fractures has been revolutionized by the use of proximal femoral nails (PFN), with a screw or a helical blade for fixation in the femoral head. Multiple complications like Z-effect, screw cut out, head penetration, varus collapse, and so on are known with poor technique in proximal femoral nails antirotation (PFNA). We present a case where an indigenous implant presented to us a novel problem of helical blade breakage inside the bone in situ. Removal of this blade needed an open approach, extending the surgical time as well as blood loss. This led to poorer outcomes and the intraoperative struggle for the surgeon. We feel that all surgeons, especially when using indigenous implants, should be aware of such complications and thoroughly check the helical blade and its collapsing mechanism before inserting this in the bone.
- 29 July 2021
- Published by Springer Nature in Cureus
- Vol. 13 (7)
Open AccessIndigenous Proximal Femoral Nails and Their Novel Complications
Pertrochanteric fractures are one of the commonest fractures in the geriatric age group. Management of these fractures has been revolutionized by the use of proximal femoral nails (PFN), with a screw or a helical blade for fixation in the femoral head. Multiple complications like Z-effect, screw cut out, head penetration, varus collapse, and so on are known with poor technique in proximal femoral nails antirotation (PFNA). We present a case where an indigenous implant presented to us a novel problem of helical blade breakage inside the bone in situ. Removal of this blade needed an open approach, extending the surgical time as well as blood loss. This led to poorer outcomes and the intraoperative struggle for the surgeon. We feel that all surgeons, especially when using indigenous implants, should be aware of such complications and thoroughly check the helical blade and its collapsing mechanism before inserting this in the bone.