YSYouichiro M.D Shinkai

Youichiro M.D Shinkai

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Youichiro M.D Shinkai has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    RETINAL MIGRATION AND SURGICAL OUTCOME AFTER HEMI-TEMPORAL INTERNAL LIMITING MEMBRANE PEELING VERSUS CONVENTIONAL PEELING FOR MACULAR HOLE

    by Tatsuya M.D. Jujo, Akira M.D. Shiono, Keiji M.D. Sato, Reio M.D. Sekine, Naoto M.D Uchiyama, Kota M.D Kakehashi, Akiko M.D Endo, Akira M.D. Arakawa, Youichiro M.D Shinkai, Yasushi M.D. Kitaoka

    Purpose: To investigate the anatomical changes and surgical outcomes of hemi-temporal internal limiting membrane (ILM) peeling and conventional ILM peeling for idiopathic macular hole (MH). Methods: This randomized controlled trial was conducted at 3 centers and included 50 participants with MHs of µm in minimum diameter for a duration of P = 0.009). Retinal migration to the optic disk on the nasal side was significantly shorter in the Hemi group at 1, 3, and 6 months postoperatively than in the 360° group. There was no significant difference between the two groups in retinal migration to the optic disk on the temporal side. Conclusion: Nasal retinal migration in patients who underwent the hemi-temporal ILM peeling method was significantly less than in those who underwent the 360° ILM peeling method. However, less nasal retinal migration did not contribute to the MH closure rate.


  • Open Access

    Ex vivo Comparison of Intraocular Pressure Fluctuation during Pars Plana Vitrectomy Performed Using 25- and 27-Gauge Systems

    by Yoichiro Shinkai, Kazuhito Yoneda, Chie Sotozono

    Introduction: The purpose of this study was to compare intraoperative intraocular pressure fluctuation using different aspiration systems and 25- and 27-gauge vitreous surgery probes. Methods: Ex vivo, pars plana, 25- and 27-gauge vitreous surgery was performed on 4 porcine eyes, and IOP fluctuations were evaluated. We performed 3-port vitrectomy using the Constellation® Vision or the EVA® Phaco-Vitrectomy system. Each 20-s experiment was conducted 5 times for each set of conditions, each with the same substituted balanced salt solution. Real-time intraoperative intraocular pressure measurement was performed at the distal end of the infusion tube. Intraocular pressure was measured during core vitrectomy, core vitrectomy with fluid aspiration, peripheral vitreous shaving with scleral indentation, and fluid-gas exchange. The Mann-Whitney U test was used to evaluate statistical significance. Results: Mean ± standard deviation intraoperative intraocular pressure fluctuation during 25- and 27-gauge core vitrectomy was 15.9 ± 1.6 and 11.9 ± 1.4 mm Hg, respectively (p < 0.05), using the Constellation system; 23.2 ± 1.4 and 14.1 ± 0.7 mm Hg, respectively (p < 0.001), using the EVA vacuum mode; and 15.0 ± 0.5 and 11.5 ± 1.4 mm Hg, respectively (p < 0.05), using the EVA flow mode. The smallest intraoperative intraocular pressure fluctuations during core vitrectomy with fluid aspiration, peripheral vitreous shaving with scleral indentation, and fluid-gas exchange were all achieved using the 27-gauge EVA flow mode; these values were 14.2 ± 0.4, 35.7 ± 0.9, and 6.4 ± 0.2 mm Hg, respectively. Conclusion: Regardless of the aspiration system, intraoperative intraocular pressure fluctuation was lower during 27-gauge than during 25-gauge vitrectomy. The 27-gauge EVA flow mode produced optimal intraoperative intraocular pressure stability.