RARohit Kumar Agrawal

Rohit Kumar Agrawal

*This is an algorithmically generated author record based on publicly available information.

Rohit Kumar Agrawal has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Real-time vision-based estimation of sinter particle-size distribution for blast furnace burden control

    by Rohit Kumar Agrawal, Vikrant Pratap, Shunmugasundaram Rajendran, Srinivasagan Balamurugan

    Accurate measurement of particle-size distribution (PSD) in dense granular materials is challenging in industrial environments because particles are irregular, partially overlapping, and often observed under non-uniform illumination. Conventional laboratory methods, such as sieve analysis, provide reliable PSD measurements but are time-consuming and unsuitable for continuous monitoring in operating plants. This study presents a vision-based framework for the real-time estimation of sinter particle size distribution during blast furnace operation. Sinter PSD strongly influences burden permeability, gas flow, and overall furnace performance, making reliable monitoring essential for stable operation. The proposed approach employs high-resolution imaging with controlled multi-directional illumination to capture particle images under industrial conditions. Image-derived particle features are segmented and mapped to weight-based size distributions using a calibrated regression model, enabling non-intrusive, high-frequency PSD estimation. System performance is evaluated against laboratory sieve analysis as the reference method. Industrial validation demonstrates a mean absolute measurement error of ∼ 1.7%, with a maximum deviation of < 6% for particles larger than 5 mm. Continuous monitoring further revealed that increases in the fine particle fraction were detected prior to measurable changes in furnace performance, indicating the potential of the method for early identification of adverse granulometric trends. The results demonstrate that the proposed framework provides stable and repeatable PSD estimates under harsh industrial conditions and offers a practical approach for online granulometry of bulk particulate materials.

  • Detection and sizing of defects in large foundation bolts using HOMC guided wave annular array ultrasonic sensor

    by Rohit Kumar Agrawal, Shivanandan S Indimath, Shunmugasundaram Rajendran, Pradeep Reddy Bonikila, Srinivasagan Balamurugan

    Foundation bolts are used extensively in various areas such as construction, engineering, automobile and mechanical industries for connecting steel structures to concrete structures. These bolts are prone to failure in extreme field conditions, that is, vibrations, elevated temperature, moisty and corrosive environment. Major reason for failure of foundation bolt is opening of fatigue cracks on fillet portion in a T-head foundation bolt due to several reasons like overloading, corrosion and poor installation. Abrupt failure of these bolts may lead to breakdowns, that is, production loss and unsafe condition. Real-time condition assessment of bolts is essential for early detection of defects, that is, predictive maintenance. A state-of-the-art sensor is designed for continuous monitoring of cracks and their growth in foundation bolts using HOMC guided wave ultrasonic testing was developed. The methodology overcomes harsh ambience, that is, high temperature, moist environment and continuous water spillage over the bolt with limited accessibility of tail end (thread side). A higher sensitivity of cracks as small as 2% of the diameter was achieved in M80 and M100 foundation bolts of approximately 2850 to 3350 mm in length. A robust and reliable sensor assembly was designed, and brownfield installation was achieved in harsh conditions of a hot rolling mill.

  • Acoustic agglomeration of dust particles as preconditioning mechanism at inlet of electrostatic precipitator in sinter plants

    by Tathagata Ray, Rohit Kumar Agrawal, Shunmugasundaram Rajendran, Srinivasagan Balamurugan, Debanik Mitra, Juan A. Gallego-Juarez

    Suspended dust particles are harmful for human. Acoustic agglomeration is one interesting solution to remove dust. It is better than other techniques of dust removal, that is, Baghouse filter, ceramic filter and washing in terms of drop of temperature and pressure and cost. Agglomeration of fine dust particles bigger than PM 10 is studied in the article. Through modelling and characterisation acoustic parameters were fixed for less than two-micron particles. Separate chamber before electrostatic precipitator (ESP) with series of acoustic transducers for coagulation of agglomerated particles has been proposed as preconditioner to ESP. The proposed technique is promising in similar applications.


  • A novel method for online bulk density measurement in stamped charging machine using force sensors

    by R. Shunmuga Sundaram, Vikrant Pratap, Rohit Kumar Agrawal, Bonikila Pradeep Reddy, Taher Mohammed Sahara, Shivanandan S I, S. Balamurugan, Amit Kumar

    Stamped charging of coal has become increasingly demanded in blast furnaces, as pulverized coal injection is more used. In the stamped charging process, the bulk density of the coal is the most important parameter, which affects the productivity and campaign life of the coke oven batteries. Hence, online measurement of coal bulk density is very crucial for increased productivity. In this paper, a novel methodology that exploits the relationship between coal bulk density and sidewall pressure is discussed. The relationship has been quantitatively established by lab-scale experiments. Also, the lab-scale experiment describes a unique methodology, which enables pressure sensor mounting on the actual stamping machine for the actual application. The obtained relationship can be used directly for determining the bulk density of the actual stamped charge coal cakes in coke plants.


  • Real-time measurement of stave thickness in a blast furnace using sacrificial ultrasonic waveguide

    by Rohit Kumar Agrawal, Rajendran Shunmugasundaram, Shivanandan Indimath, Taher Mohammed Sahara, Bonikila Pradeep Reddy, Vikrant Pratap, Srinivasagan Balamurugan

    A stave cooling system is a key element in the blast furnace which protects the outer shell from heat by providing uniform cooling. Real-time condition assessment of staves is essential to understand the wear mechanism of staves. Inspection rod/waveguide of known length which is made of copper was inserted through the steel shell till the inner end of the stave where the waveguide is susceptible to reduce in length as stave erodes with time. FEM analysis was done to find the ultrasonic parameters and lab-scale trials were taken on artificial waveguides with different end conditions. Based on the results, an ultrasonic-based real-time thickness measurement system was developed to continuously measure the length of the inspection rod/waveguide which eventually represents the stave thickness. System was installed in the plant, the data was captured and shown for 60 days from the date of the installation with an accuracy of more than 98%.


  • Ultrasonic guided wave technique for the detection of extremely shallow corrosion defects in tie rods of coke oven batteries

    by Shivanandan Indimath, Rohit Agrawal, Rajendran Shunmugasundaram, Taher Mohammed Sahara, Srinivasagan Balamurugan, Sujit Dutta, Uday Shankar, Awadhesh Kumar Thakur, Avijit Mukherjee, Ranjan Singh

    Coke oven batteries utilize tie rods embedded within the concrete structure to enhance the structural strength of the oven walls. The tie rods are susceptible to corrosion in the form of gradual reduction in cross-section over a large length (1–2 m) of the tie rod which compromises the structural integrity of oven walls. This work describes an ultrasonic guided wave technique utilizing low frequency L(0,1) mode to detect and locate such shallow corrosion defects with access only to the ends of the tie rods. FEM studies describing the behaviour of L(0,1) mode for various geometrical parameters of the defect are discussed. The FEM results are validated by few experimental results on tie rods with corrosion defects. The accuracy of the measurement technique, in the experimental results, for locating the axial position of defect and its length was found to be >94% and >86% respectively.