Gérard Petit
Research Subjects
Research Interests
Gérard Petit has a total of 121 co-authors. Here are the top co-authors by number of shared publications:
- Pascale Defraigne
Royal Observatory of Belgium
4 shared publications - Tetsuya Ido
National Institute of Information and Communications Technology, 4-2-1 Nukui-Kitamachi, Koganei, Tokyo 184-8795, Japan
4 shared publications - Frederic Meynadier
Time Department, BIPM, Pavillon de Breteuil, 92310 Sèvres, France
3 shared publications A Harmegnies
Bureau International des Poids et Mesures, Sèvres, France
2 shared publications- Christopher Oates
National Institute of Standards and Technology (NIST), Boulder, CO 80305, United States of America
2 shared publications - Claudio Bortolotti
Radiotelescopi di Medicina, INAF, Istituto di Radioastronomia, Bologna, Italy
2 shared publications
Latest Publications
- Open Access
- 1 August 2026
- Published by IOP Publishing in Metrologia
- Vol. 63 (4) , 045006
TT(BIPM): its realization and use as a reference timescale
The BIPM has computed and published a realization of Terrestrial Time, named TT(BIPM), since 1987 and has formalized its yearly publication since 2005. We review the history of this computation and detail the algorithm and the operational parameters along with their evolution over the years. We emphasize the evolution in the frequency accuracy of TT(BIPM) obtained from the uncertainty of the monthly estimates of a frequency comparison to all available evaluations of primary and secondary frequency standards (PSFS). We show how TT(BIPM) aims at providing the best realization of TT over the long term and detail some applications of using TT(BIPM) as a reference timescale e.g. for pulsar analysis, for evaluating TAI or for estimating the performance of PSFS. Finally we provide some directions to acheive further improvements in the years to come.
- 1 August 2026
- Published by IOP Publishing in Metrologia
- Vol. 63 (4) , 045006
Open AccessTT(BIPM): its realization and use as a reference timescale
The BIPM has computed and published a realization of Terrestrial Time, named TT(BIPM), since 1987 and has formalized its yearly publication since 2005. We review the history of this computation and detail the algorithm and the operational parameters along with their evolution over the years. We emphasize the evolution in the frequency accuracy of TT(BIPM) obtained from the uncertainty of the monthly estimates of a frequency comparison to all available evaluations of primary and secondary frequency standards (PSFS). We show how TT(BIPM) aims at providing the best realization of TT over the long term and detail some applications of using TT(BIPM) as a reference timescale e.g. for pulsar analysis, for evaluating TAI or for estimating the performance of PSFS. Finally we provide some directions to acheive further improvements in the years to come.
- 25 June 2025
- Published by IOP Publishing in Metrologia
- Vol. 62 (4) , 048001
Comment on ‘A proposal to change the leap-second adjustments to UTC’
In the paper ‘A proposal to change the leap-second adjustments to UTC’ (Levine 2024 Metrologia 61 055002) the author proposes to replace the present system of leap seconds in UTC by an algorithmic adjustment process based on adjusting UTC at planned dates according to a prediction of UT1 variations. The author claims that applying this scheme to historical data provides a UTC scale consistent with UT1 within a few seconds over several decades and that a tolerance of one minute would be sufficient to use this scheme for one century. We show here that the description of the algorithm by the author is ambiguous and the numerical examples he provided are misleading. We complete the description of the algorithm so that it can be put into practice and we test it over generated series of values that reproduce the long term behavior of (TT-UT1). We find that such an algorithmic adjustment process would require that excursions of (UT1-UTC) of several minutes are tolerated and we also discuss other implications of the proposed algorithm.
- 25 June 2025
- Published by IOP Publishing in Metrologia
- Vol. 62 (4) , 048001
Comment on ‘A proposal to change the leap-second adjustments to UTC’
In the paper ‘A proposal to change the leap-second adjustments to UTC’ (Levine 2024 Metrologia 61 055002) the author proposes to replace the present system of leap seconds in UTC by an algorithmic adjustment process based on adjusting UTC at planned dates according to a prediction of UT1 variations. The author claims that applying this scheme to historical data provides a UTC scale consistent with UT1 within a few seconds over several decades and that a tolerance of one minute would be sufficient to use this scheme for one century. We show here that the description of the algorithm by the author is ambiguous and the numerical examples he provided are misleading. We complete the description of the algorithm so that it can be put into practice and we test it over generated series of values that reproduce the long term behavior of (TT-UT1). We find that such an algorithmic adjustment process would require that excursions of (UT1-UTC) of several minutes are tolerated and we also discuss other implications of the proposed algorithm.
- Open Access
- 1 July 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (4) , 045005
Discussion on the calculation of the uncertainties of [UTC-UTC(k)]
Coordinated universal Time UTC is the reference timescale generated by the BIPM and is made available through the published values [UTC–UTC(k)]. In a previous paper, Panfilo et al (2020 Metrologia 57 065011) we examined the calculation of the uncertainties of [UTC–UTC(k)] and proposed some evolution to the current procedure. We here complete and clarify two main issues related to this calculation that have appeared in discussions and publications following our previous paper. We state (i) that the systematic uncertainty for a specific laboratory UTC(k) is not affected by biases from other laboratories and (ii) that the uncertainties of [UTC–UTC(k)] only depend on the input covariance of the epoch. We highlight the role of UTC and of the uncertainties of [UTC–UTC(k)]. Based on the present computation algorithm ALGOS, we detail internal procedures of the BIPM Time Department implementing the algorithm to ensure the continuity of UTC when changes occur e.g. a new laboratory entering UTC or a new calibration introduced in a specific receiver/time link.
- 1 July 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (4) , 045005
Open AccessDiscussion on the calculation of the uncertainties of [UTC-UTC(k)]
Coordinated universal Time UTC is the reference timescale generated by the BIPM and is made available through the published values [UTC–UTC(k)]. In a previous paper, Panfilo et al (2020 Metrologia 57 065011) we examined the calculation of the uncertainties of [UTC–UTC(k)] and proposed some evolution to the current procedure. We here complete and clarify two main issues related to this calculation that have appeared in discussions and publications following our previous paper. We state (i) that the systematic uncertainty for a specific laboratory UTC(k) is not affected by biases from other laboratories and (ii) that the uncertainties of [UTC–UTC(k)] only depend on the input covariance of the epoch. We highlight the role of UTC and of the uncertainties of [UTC–UTC(k)]. Based on the present computation algorithm ALGOS, we detail internal procedures of the BIPM Time Department implementing the algorithm to ensure the continuity of UTC when changes occur e.g. a new laboratory entering UTC or a new calibration introduced in a specific receiver/time link.
- Top Cited PapersOpen Access
- 30 April 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (3) , 035005
The CIPM list ‘Recommended values of standard frequencies’: 2021 update
This paper gives a detailed account of the analysis underpinning the 2021 update to the list of standard reference frequency values recommended by the International Committee for Weights and Measures. This update focused on a subset of atomic transitions that are secondary representations of the second (SRS) or considered as potential SRS. As in previous updates in 2015 and 2017, methods for analysing over-determined data sets were applied to make optimum use of the worldwide body of published clock comparison data. To ensure that these methods were robust, three independent calculations were performed using two different algorithms. The 2021 update differed from previous updates in taking detailed account of correlations among the input data, a step shown to be important in deriving unbiased frequency values and avoiding underestimation of their uncertainties. It also differed in the procedures used to assess input data and to assign uncertainties to the recommended frequency values, with previous practice being adapted to produce a fully consistent output data set consisting of frequency ratio values as well as absolute frequencies. These changes are significant in the context of an anticipated redefinition of the second in terms of an optical transition or transitions, since optical frequency ratio measurements will be critical for verifying the international consistency of optical clocks prior to the redefinition. In the meantime, the reduced uncertainties for optical SRS resulting from this analysis significantly increases the weight that secondary frequency standards based on these transitions can have in the steering of International Atomic Time.
- 30 April 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (3) , 035005
Top Cited PapersOpen AccessThe CIPM list ‘Recommended values of standard frequencies’: 2021 update
This paper gives a detailed account of the analysis underpinning the 2021 update to the list of standard reference frequency values recommended by the International Committee for Weights and Measures. This update focused on a subset of atomic transitions that are secondary representations of the second (SRS) or considered as potential SRS. As in previous updates in 2015 and 2017, methods for analysing over-determined data sets were applied to make optimum use of the worldwide body of published clock comparison data. To ensure that these methods were robust, three independent calculations were performed using two different algorithms. The 2021 update differed from previous updates in taking detailed account of correlations among the input data, a step shown to be important in deriving unbiased frequency values and avoiding underestimation of their uncertainties. It also differed in the procedures used to assess input data and to assign uncertainties to the recommended frequency values, with previous practice being adapted to produce a fully consistent output data set consisting of frequency ratio values as well as absolute frequencies. These changes are significant in the context of an anticipated redefinition of the second in terms of an optical transition or transitions, since optical frequency ratio measurements will be critical for verifying the international consistency of optical clocks prior to the redefinition. In the meantime, the reduced uncertainties for optical SRS resulting from this analysis significantly increases the weight that secondary frequency standards based on these transitions can have in the steering of International Atomic Time.
- Top Cited PapersOpen Access
- 22 January 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (1) , 012001
Roadmap towards the redefinition of the second
This paper outlines the roadmap towards the redefinition of the second, which was recently updated by the CCTF Task Force created by the CCTF in 2020. The main achievements of optical frequency standards (OFS) call for reflection on the redefinition of the second, but open new challenges related to the performance of the OFS, their contribution to time scales and UTC, the possibility of their comparison, and the knowledge of the Earth’s gravitational potential to ensure a robust and accurate capacity to realize a new definition at the level of 10−18uncertainty. The mandatory criteria to be achieved before redefinition have been defined and their current fulfilment level is estimated showing the fields that still needed improvement. The possibility to base the redefinition on a single or on a set of transitions has also been evaluated. The roadmap indicates the steps to be followed in the next years to be ready for a sound and successful redefinition.
- 22 January 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (1) , 012001
Top Cited PapersOpen AccessRoadmap towards the redefinition of the second
This paper outlines the roadmap towards the redefinition of the second, which was recently updated by the CCTF Task Force created by the CCTF in 2020. The main achievements of optical frequency standards (OFS) call for reflection on the redefinition of the second, but open new challenges related to the performance of the OFS, their contribution to time scales and UTC, the possibility of their comparison, and the knowledge of the Earth’s gravitational potential to ensure a robust and accurate capacity to realize a new definition at the level of 10−18uncertainty. The mandatory criteria to be achieved before redefinition have been defined and their current fulfilment level is estimated showing the fields that still needed improvement. The possibility to base the redefinition on a single or on a set of transitions has also been evaluated. The roadmap indicates the steps to be followed in the next years to be ready for a sound and successful redefinition.
- 6 November 2023
- Published by IOP Publishing in Metrologia
- Vol. 60 (6) , 065010
Monitoring of the offset between UTC and its prediction broadcast by the GNSS
We present a new approach to report, in the section 4 of International Bureau of Weights and Measures Circular T, daily values of the offset between Coordinated Universal Time (UTC) and the predictions of UTC broadcast by the Global Navigation Satellite Systems (GNSS), this quantity we name bUTCGNSS. In this approach, the determination of UTC-bUTCGNSS is based on data collected by several multi-GNSS stations in selected time laboratories worldwide. Test computations over a 7-month period from July 2022 to January 2023 show that the offset between UTC and bUTCGNSS was between 30 and 50 ns for GLONASS, between 5 and 20 ns for BeiDou, and between −5 and +5 ns for GPS and Galileo. We derive the uncertainty on the reported values, which is 4.1 ns for BeiDou and GPS, 3.7 ns for Galileo and 6.6 ns for GLONASS and show that, over the test period, the reported values of UTC-bUTCGNSS and the solutions obtained from each multi-GNSS station are all consistent within the 1-sigma uncertainties.
- 6 November 2023
- Published by IOP Publishing in Metrologia
- Vol. 60 (6) , 065010
Monitoring of the offset between UTC and its prediction broadcast by the GNSS
We present a new approach to report, in the section 4 of International Bureau of Weights and Measures Circular T, daily values of the offset between Coordinated Universal Time (UTC) and the predictions of UTC broadcast by the Global Navigation Satellite Systems (GNSS), this quantity we name bUTCGNSS. In this approach, the determination of UTC-bUTCGNSS is based on data collected by several multi-GNSS stations in selected time laboratories worldwide. Test computations over a 7-month period from July 2022 to January 2023 show that the offset between UTC and bUTCGNSS was between 30 and 50 ns for GLONASS, between 5 and 20 ns for BeiDou, and between −5 and +5 ns for GPS and Galileo. We derive the uncertainty on the reported values, which is 4.1 ns for BeiDou and GPS, 3.7 ns for Galileo and 6.6 ns for GLONASS and show that, over the test period, the reported values of UTC-bUTCGNSS and the solutions obtained from each multi-GNSS station are all consistent within the 1-sigma uncertainties.
- 21 March 2023
- Published by IOP Publishing in Metrologia
- Vol. 60 (2) , 025009
Calibration of GNSS stations for UTC
Global navigation satellite system (GNSS) time transfer has been used for four decades in the generation of universal time coordinated (UTC), starting with GPS in the 1980s. Calibration of GNSS receivers is then essential to ensure that time links used in UTC are accurate and remain stable with time. In this paper we study the different calibration schemes based on relative calibration of GNSS receivers that have been operated to fulfill these goals. We specially focus on the current calibration scheme in operation since 2014 and based on a collaboration between the BIPM and the Regional Metrology Organizations. We show that the achieved accuracy and long-term stability of calibration results, thus of UTC time links, are well in line with the stated uncertainties. We study an extended set of absolute calibration results and show that they complete and validate the BIPM scheme, and that relative calibration is still the essential tool to ensure accurate time links for UTC.
- 21 March 2023
- Published by IOP Publishing in Metrologia
- Vol. 60 (2) , 025009
Calibration of GNSS stations for UTC
Global navigation satellite system (GNSS) time transfer has been used for four decades in the generation of universal time coordinated (UTC), starting with GPS in the 1980s. Calibration of GNSS receivers is then essential to ensure that time links used in UTC are accurate and remain stable with time. In this paper we study the different calibration schemes based on relative calibration of GNSS receivers that have been operated to fulfill these goals. We specially focus on the current calibration scheme in operation since 2014 and based on a collaboration between the BIPM and the Regional Metrology Organizations. We show that the achieved accuracy and long-term stability of calibration results, thus of UTC time links, are well in line with the stated uncertainties. We study an extended set of absolute calibration results and show that they complete and validate the BIPM scheme, and that relative calibration is still the essential tool to ensure accurate time links for UTC.
- 5 July 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (4) , 045007
Continuous IPPP links for UTC
The technique of precise point positioning with integer ambiguity resolution (IPPP) has been developed for many years and has been shown to significantly improve the long-term performance of time and frequency transfer with respect to other GNSS-based techniques. In this paper, we present results of GPS IPPP links over a period of 22 months for a dozen time laboratories participating to UTC. We show that continuous links, in which the continuity of the GPS phase measurements is preserved, can be maintained for periods exceeding one year and further extended if data from two receivers per station are available. We quantify the frequency transfer uncertainty of IPPP by comparison to optical links and show how IPPP could improve UTC links to below 1 × 10−16 relative frequency uncertainty over averaging times of up to one month, i.e. the characteristic period of UTC publication. Comparisons of primary and secondary frequency standards reported for TAI indicate that IPPP could somewhat improve the accuracy of TAI/UTC. Comparisons of IPPP to two-way time transfer techniques reveal very long-term ns-size instabilities which must be further studied. Use of IPPP for UTC links is possible only if integer GNSS satellite products become available with a short delay and we report on such experimental products. Finally, we discuss the practical implications of using IPPP link in UTC and describe how the necessary steps could be implemented.
- 5 July 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (4) , 045007
Continuous IPPP links for UTC
The technique of precise point positioning with integer ambiguity resolution (IPPP) has been developed for many years and has been shown to significantly improve the long-term performance of time and frequency transfer with respect to other GNSS-based techniques. In this paper, we present results of GPS IPPP links over a period of 22 months for a dozen time laboratories participating to UTC. We show that continuous links, in which the continuity of the GPS phase measurements is preserved, can be maintained for periods exceeding one year and further extended if data from two receivers per station are available. We quantify the frequency transfer uncertainty of IPPP by comparison to optical links and show how IPPP could improve UTC links to below 1 × 10−16 relative frequency uncertainty over averaging times of up to one month, i.e. the characteristic period of UTC publication. Comparisons of primary and secondary frequency standards reported for TAI indicate that IPPP could somewhat improve the accuracy of TAI/UTC. Comparisons of IPPP to two-way time transfer techniques reveal very long-term ns-size instabilities which must be further studied. Use of IPPP for UTC links is possible only if integer GNSS satellite products become available with a short delay and we report on such experimental products. Finally, we discuss the practical implications of using IPPP link in UTC and describe how the necessary steps could be implemented.
- 18 May 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (3) , 035007
A three-cornered hat analysis of instabilities in two-way and GPS carrier phase time transfer systems
A three-cornered hat analysis has been performed on three independent time transfer systems between the United States Naval Observatory (USNO) and the National Institute of Standards and Technology (NIST). These include (1) a direct Two-Way Satellite Time and Frequency Transfer (TWSTFT) link provided by the USNO, (2) an indirect TWSTFT link, and (3) GPS carrier phase (GPSCP) links. Time transfer instabilities for individual links, as quantified with the time deviation and TOTAL time deviation, have been measured for the first time for averaging periods between 2 h and 85 days. Time transfer instabilities beyond one day are roughly flicker phase in nature and generally range between 40 ps and 120 ps. Frequency transfer instabilities, as quantified by the modified Allan deviation, are observed to be as low as 1 × 10−16 for a 20 day comparison and into the mid 10−17 range at longer comparison times.
- 18 May 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (3) , 035007
A three-cornered hat analysis of instabilities in two-way and GPS carrier phase time transfer systems
A three-cornered hat analysis has been performed on three independent time transfer systems between the United States Naval Observatory (USNO) and the National Institute of Standards and Technology (NIST). These include (1) a direct Two-Way Satellite Time and Frequency Transfer (TWSTFT) link provided by the USNO, (2) an indirect TWSTFT link, and (3) GPS carrier phase (GPSCP) links. Time transfer instabilities for individual links, as quantified with the time deviation and TOTAL time deviation, have been measured for the first time for averaging periods between 2 h and 85 days. Time transfer instabilities beyond one day are roughly flicker phase in nature and generally range between 40 ps and 120 ps. Frequency transfer instabilities, as quantified by the modified Allan deviation, are observed to be as low as 1 × 10−16 for a 20 day comparison and into the mid 10−17 range at longer comparison times.
- Open Access
- 25 March 2021
- Published by Springer Nature in Journal of Geodesy
- Vol. 95 (4) , 1-27
A broadband VLBI system using transportable stations for geodesy and metrology: an alternative approach to the VGOS concept
We have developed a broadband VLBI (very long baseline interferometry) system inspired by the concept of the VLBI Global Observing System (VGOS). The new broadband VLBI system was implemented in the Kashima 34 m antenna and in two transportable stations utilizing 2.4 m diameter antennas. The transportable stations have been developed as a tool for intercontinental frequency comparison but are equally useful for geodesy. To enable practical use of such small VLBI stations in intercontinental VLBI, we have developed the procedure of node-hub style VLBI: In joint observation with a large, high sensitivity ‘hub’ antenna, the closure delay relation provides a virtual delay observable between ‘node’ stations. This overcomes the limited sensitivity of the small diameter node antennas, while error sources associated with large diameter antennas, such as gravitational deformation and delay changes in necessarily long signal cables, are eliminated. We show that this scheme does not result in an increased sensitivity to radio source structure if one side of the baseline triangle is kept short. We have performed VLBI experiments utilizing this approach over both short range and intercontinental distance. This article describes the system components, signal processing procedure, experiment, and results in terms of baseline repeatability. Our measurements reveal signatures of structure effects in the correlation amplitude of several of the observed radio sources. We present a model of the frequency-dependent source size for 1928+738 derived from correlation amplitude data observed in four frequency bands.
- 25 March 2021
- Published by Springer Nature in Journal of Geodesy
- Vol. 95 (4) , 1-27
Open AccessA broadband VLBI system using transportable stations for geodesy and metrology: an alternative approach to the VGOS concept
We have developed a broadband VLBI (very long baseline interferometry) system inspired by the concept of the VLBI Global Observing System (VGOS). The new broadband VLBI system was implemented in the Kashima 34 m antenna and in two transportable stations utilizing 2.4 m diameter antennas. The transportable stations have been developed as a tool for intercontinental frequency comparison but are equally useful for geodesy. To enable practical use of such small VLBI stations in intercontinental VLBI, we have developed the procedure of node-hub style VLBI: In joint observation with a large, high sensitivity ‘hub’ antenna, the closure delay relation provides a virtual delay observable between ‘node’ stations. This overcomes the limited sensitivity of the small diameter node antennas, while error sources associated with large diameter antennas, such as gravitational deformation and delay changes in necessarily long signal cables, are eliminated. We show that this scheme does not result in an increased sensitivity to radio source structure if one side of the baseline triangle is kept short. We have performed VLBI experiments utilizing this approach over both short range and intercontinental distance. This article describes the system components, signal processing procedure, experiment, and results in terms of baseline repeatability. Our measurements reveal signatures of structure effects in the correlation amplitude of several of the observed radio sources. We present a model of the frequency-dependent source size for 1928+738 derived from correlation amplitude data observed in four frequency bands.