AZAhmad Zakiyuddin

Ahmad Zakiyuddin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ahmad Zakiyuddin has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Film characteristics and electrochemical behavior of hydrothermally synthesized hydroxyapatite/polyacrylic acid composite coatings on WE43 magnesium alloy

    by Aprilia Erryani, Fendy Rokhmanto, Albertus Deny Heri Setyawan, Yudi Nugraha Thaha, Ahmad Zakiyuddin, Ika Kartika, Sri Harjanto

    Biodegradable magnesium (Mg) alloys are promising for temporary implants in orthopedic applications, but the prospects have been restricted by their rapid corrosion rate that occurs under physiological conditions. This study demonstrates the incorporation of hydroxyapatite/polyacrylic acid (HAp/PAA) biocomposite layers onto a WE43 magnesium alloy through a simple hydrothermal process to improve the surface morphology, enhance the corrosion resistance, and promote self-healing properties. The addition of polyacrylic acid (PAA) substantially improves the quality of the hydroxyapatite (HAp) layer, as it significantly reduces inside cracks and increases the uniformity of the layer. The HAp crystals become denser and more rigid and thereby suppress the number of fine cracks in the coating as a result of the reaction with ions from PAA. The nucleation process of hydroxyapatite crystals is influenced by hydrothermal time. In this research, the deposition durations were varied for 1, 2, and 3 h. A dense and compact HAp/PAA composite coating resulting from a prolonged (i.e., 3 h) hydrothermal process remarkably decreases the corrosion rate. Furthermore, the HAp/PAA biocomposite coating exhibits excellent self-healing properties, as evidenced by the reformation of a new HAp layer during a 48 h scratch-immersion test in Hanks’ solution at 37 °C. This work therefore shows that the multifunctional HAp/PAA biocomposite coating can be effective for controlling the corrosion rate of a magnesium alloy and, at the same time, for promoting recovery of the protection layer.

  • Open Access

    FAILURE ANALYSIS OF SKID PIPE LEAKS IN WALKING BEAM TYPE REHEATING FURNACE APPLICATIONS

    by Muhamad Aldi Tripangestu, Ahmad Zakiyuddin

    This study investigates the failure of skid pipes within a walking beam reheating furnace at PT. X, Cilegon City. Visual inspection, chemical composition analysis, and corrosion rate evaluation revealed physical damages such as cracks, black and white scale deposits, bulging, and a 47% reduction in pipe thickness from the original 25 mm. The damage mechanism is initiated by high levels of Fe oxides causing corrosion with a dominant wustite (FeO) phase, and elements such as Ca, Mg, and Si contributing to scale formation. High water hardness (82.02 mg/L in pipe circulation) also supports scale formation. The LSI and RSI indices indicate highly aggressive water with high corrosiveness, causing localized overheating of the skid pipes. This increases the creep rate due to refractory damage, leading to high-temperature exposure and subsequent pipe leakage marked by bulging. Enhanced slag control within the reheating furnace, routine slag cleaning, and a review of cleaning schedules and frequencies to prevent similar failures.

  • Open Access

    Amperometric Biosensor Detecting Dopamine Based on Polypyrrole/Reduced Graphene Oxide/Nickel Oxide/Glassy Carbon Electrode

    by Shindy Ayu Netania Priyanto, Elly Septia Yulianti, Ahmad Zakiyuddin, Siti Fauziyah Rahman

    Dopamine (3,4‐dihydroxyphenethylamine) (DA) plays an important role in influencing emotions, pleasure sensations, concentration, pain, and coordination of body movements. However, abnormal levels of DA in the brain can lead to Parkinson’s, Alzheimer’s, or schizophrenia diseases. A biosensor is defined as an analytical tool that combines certain biological recognition components with a physical transducer. A comprehensive study was conducted to enhance the performance of DA detection by incorporating reduced graphene oxide (rGO), polypyrrole (PPy), and nickel oxide (NiO) into the glassy carbon electrode (GCE). DA levels were measured using cyclic voltammetry (CV) with a three‐electrode configuration. Material characterization was evaluated by scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FTIR). The results obtained indicate that PPy/rGO/NiO/GCE has a detection limit of 0.195 mM and a sensitivity of 25.887 A mM−1 cm−2 for a linear range of 0.01–1 mM.


  • Improvement in mechanical properties of Mg-Li-Al alloys as orthopedic implants using thermomechanical process: A review

    by Ahmad Zakiyuddin, Muhamad Mushabhanif Ghazy, Nabila Jasmine, Siti Fauziyah Rahman

    In recent years, Magnesium alloy has gained big interest to be developed as orthopedic implant material due to its good biocompatibility and mechanical properti

  • Open Access

    Evaluation of coating performance on carbon steel A-36 in copper concentrate environment using electrochemical impedance spectroscopy

    by Ahmad Fauzi, Ahmad Zakiyuddin

    The presence of chalcopyrite increases the corrosion rate of carbon steel through a galvanic couple. In this study, five organic coating systems were evaluated for their strength against consequent corrosion in the presence of copper concentrate by electrochemistry impedance spectroscopy (EIS) measurement. The coating system studied are a single application epoxy coating (C1); a three-layer epoxy system with zinc-rich epoxy primer base coat, surface tolerant epoxy middle layer, and a top layer polyurethane (C2); a three-layer epoxy system that has the advantages of fast dry time consist of epoxy zinc phosphate base coat primer, the middle layer of the epoxy primer containing the pigment zinc phosphate and top layer polyurethane (C3); metallic pigmented polyurethane coating (C4), and an epoxy coating which can be applied to wet surfaces or in water (C5). All those systems have been tested by the EIS. The test results showed that C2, C3, C4, and C5 coating systems maintained good barrier properties during the immersion process, the low frequency |Z| is more than 108Ω.cm2after 30 days of immersion exposure. Epoxy modified coating (C1) had the lowest impedance with resistance under 106Ω.cm2provide poor corrosion protection.

  • Loading Effect of Ag Nanoparticles on Photocatalytic Activity of TiO2 Nanorod Arrays Prepared by Hydrothermal Method

    by Kwangmin Lee, Daeheung Yoo, Ahmad Zakiyuddin

    Rutile-TiO2 nanorod thin films were formed on Ti disks via alkali treatment in NaOH solutions followed by heat treatment at 700°C. Ag nanoparticles were loaded on nanorods using a photo-reduction method to improve the photocatalytic properties of the prepared specimen. The surface characterization and the photo-electrochemical properties of the Ag-loaded TiO2 nanorods were investigated using a field-emission scanning electron microscope (FE-SEM), X-ray photoelectron spectroscopy (XPS), UV-Vis spectroscopy and electrochemical impedance spectroscopy (EIS). The TiO2 nanorods obtained after the heat treatment were 80 to 180 nm thick and 1 μm long. The thickness of the nanorods increased with the NaOH concentration. The UV-Vis spectra exhibit a shift in the absorption edge of the Ag-loaded TiO2 to the visible light range and further narrowing of the bandgap. The decrease in the size of the capacitive loops in the EIS spectra showed that the Ag loading effectively improved the photocatalytic activity of the TiO2 nanorods.

  • Degradation Characteristics of Mg-1,6Gd Alloy at Low Thickness Reduction of Warm Rolling

    by Ahmad Nabil Faiz Hidayat, Ahmad Zakiyuddin, Sri Harjanto, Oknovia Susanti

    Magnesium has been developed as a biodegradable bone implant material due to its similarity in elasticity modulus of bone. However, magnesium has a higher corrosion rate and a lower strength. Gadolinium is alloyed to magnesium in order to improve the corrosion resistance and then rolled to improve the strength due to grain refinement in rolling. Cold roll produced the finest grain, but magnesium has a poor formability. Due to this fact, warm rolling with temperature 247 – 375 oC is applied. Optical Microscope, Scanning Electron Microscope (SEM), and Energy Dispersive Spectrometry (EDS) are used for characterization. Electrochemical Impedance Spectroscopy (EIS) and Polarization test were carried out to observe the corrosion mechanism of Mg-Gd in SBF Kokubo to replicate a human body condition. The result of polarization test shows that the cross-rolled sample experienced an increase in E corr, with 0,15 and –0,048 V due to a better distribution of Gadolinium. EIS states that the single pass rolled sample has a stronger passive layer with 116 and 126 kΩ value of Rf due to a smaller grain size which resulted a fewer compression stress. The hydrogen evolution was also observed with immersion test. Keywords: uni-directional rolling, cross-directional rolling, corrosion, simulated body fluid, hydrogen evolution.

  • Recyclability of Dental Gypsum via Calcination

    by Ahmad Zakiyuddin, Decky Joesiana Indrani, Rifqi A. Khoirurrijal, Sotya Astutiningsih

    Nowadays, either keeping or throwing out the final product of dental cast is the most common thing to do. The waste from dentistry can be considered toxic if not handled specifically and separately to other waste. Hence, the recycling process can reduce its effect and the waste of dental casts. It can also reduce the cost of producing new high-grade dental gypsum. This paper studies the behavior of before-after recycle and heat treatment to several grades of dental gypsum that will be used as impression material or dies. As it is designed to be an impression material that will undergo heat treatment, Simultaneous Thermogravimetry and Differential Scanning Calorimetry (TGA-DSC) will be applied to understand the Phase Transformation to its mass change and the behavior to a temperature difference. The result will be validated using an experimental approach. X-ray Diffraction (XRD) and Scanning Electron Microscope will also be done to identify the crystalline phases and the surface microstructure, and it will be validated using an experimental approach as well. A range of gaps between parameter values is expected between the fresh/new dental gypsum and the recycled one. However, it is expected some similar values between the heat-treated and the fresh/new dental gypsum.