Sining Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sining Li has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Feng Duan
Tianjin Key Laboratory of Interventional Brain-Computer Interface and Intelligent Rehabilitation, College of Artificial Intelligence, Nankai University, Tianjin, China
4 shared publications Gan Liu
Tianjin Key Laboratory of Interventional Brain-Computer Interface and Intelligent Rehabilitation, Nankai University, Tianjin, China
2 shared publications- Wenzhi Wang
Tianjin Key Laboratory of Interventional Brain-Computer Interface and Intelligent Rehabilitation, Nankai University, Tianjin, China
2 shared publications Yudong Ma
Department of Neurosurgery, Air Force Medical University, Beijing, China
2 shared publications- Di Liu
National Key Laboratory of Laser Spatial Information, Harbin Institute of Technology, Harbin 150001, China
1 shared publication Fan Feng
Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
1 shared publication
Latest Publications
- Open Access
- 21 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34 (15344320) , 2256-2264
Closed-Loop Optogenetic Temperature Control System for Inducing Mild Hypothermia in Rats
Mild hypothermia is widely recognized as a potent neuroprotective intervention. However, conventional physical cooling methods frequently trigger physiological thermoregulatory defenses, eliciting stress responses that limit clinical utility. Neuromodulation based approaches designed to lower body temperature have attracted interest as a means of circumventing these limitations. The preoptic area (POA) of the hypothalamus is a critical site for mammalian thermoregulation, and the medial preoptic area (MPA) sub region contains a high density of temperature sensitive neurons. Prior work has shown that activation of step function opsins (SSFOs) within this area can be associated with a decline in core temperature. In the present study, optogenetic stimulation in awake rats was associated with a mean temperature reduction of –2.48 ± 0.40°C over a 180 minute period. Relative to chemogenetic manipulations, optogenetic stimulation yielded higher survival rates and more stable temperature trajectories under our experimental conditions. Current protocols offer limited control over the rewarming phase. To address this, we capitalized on the biophysical characteristics of sensitive step function opsins (SSFOs) which exhibit prolonged open states following blue light (465 nm) activation and can be closed by yellow light (589 nm) stimulation to design a closed-loop optogenetic system. This system enables induction, maintenance, and controlled rewarming of reduced core temperature in the rat MPA and provides a platform for further investigation of neuromodulatory strategies in the context of targeted temperature management.
- 21 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34 (15344320) , 2256-2264
Open AccessClosed-Loop Optogenetic Temperature Control System for Inducing Mild Hypothermia in Rats
Mild hypothermia is widely recognized as a potent neuroprotective intervention. However, conventional physical cooling methods frequently trigger physiological thermoregulatory defenses, eliciting stress responses that limit clinical utility. Neuromodulation based approaches designed to lower body temperature have attracted interest as a means of circumventing these limitations. The preoptic area (POA) of the hypothalamus is a critical site for mammalian thermoregulation, and the medial preoptic area (MPA) sub region contains a high density of temperature sensitive neurons. Prior work has shown that activation of step function opsins (SSFOs) within this area can be associated with a decline in core temperature. In the present study, optogenetic stimulation in awake rats was associated with a mean temperature reduction of –2.48 ± 0.40°C over a 180 minute period. Relative to chemogenetic manipulations, optogenetic stimulation yielded higher survival rates and more stable temperature trajectories under our experimental conditions. Current protocols offer limited control over the rewarming phase. To address this, we capitalized on the biophysical characteristics of sensitive step function opsins (SSFOs) which exhibit prolonged open states following blue light (465 nm) activation and can be closed by yellow light (589 nm) stimulation to design a closed-loop optogenetic system. This system enables induction, maintenance, and controlled rewarming of reduced core temperature in the rat MPA and provides a platform for further investigation of neuromodulatory strategies in the context of targeted temperature management.
- Open Access
- 23 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34 (15344320) , 1658-1667
A High-Quality and Robust Intravascular Electromyography (iEMG) Acquisition Method for Locomotor Tasks
Electromyography (EMG) is essential in medical and rehabilitation fields for assessing neuromuscular functions. However, mainstream traditional surface EMG (sEMG) is susceptible to electrode displacement or noise interference during walking, leading to lower signal quality and limited long-term stability, which constrains its broader application. To overcome these limitations, we propose a novel intravascular electromyography (iEMG) acquisition method. By a minimally invasive surgery, a self-expanding stent sensor with microelectrode and lead was implanted into the femoral vein adjacent to the tibialis anterior muscle to record deep muscle activity. In this study, sEMG and iEMG were simultaneously acquired from sheep hindlimb muscle in standing state and walking state for comparative analysis of their electrophysiological properties. Level walking served as the dynamic locomotor task in this work. Totally, this acquisition experiment lasted for three days. In standing state, both EMG exhibit a high correlation (Spearman’s ρ = 0.9018, p < 0.001). In walking state, iEMG demonstrates a 10.04% higher signal-to-noise ratio compared to sEMG. Additionally, iEMG shows a 33.82% lower coefficient of variation in power spectral density than sEMG, indicating a 1.51-fold improvement in signal stability. These results demonstrate that our iEMG acquisition method enables high-quality and robust recordings for long-term monitoring during walking, which provides a reliable foundation for clinical rehabilitation applications requiring precise, long-term muscle activity tracking.
- 23 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34 (15344320) , 1658-1667
Open AccessA High-Quality and Robust Intravascular Electromyography (iEMG) Acquisition Method for Locomotor Tasks
Electromyography (EMG) is essential in medical and rehabilitation fields for assessing neuromuscular functions. However, mainstream traditional surface EMG (sEMG) is susceptible to electrode displacement or noise interference during walking, leading to lower signal quality and limited long-term stability, which constrains its broader application. To overcome these limitations, we propose a novel intravascular electromyography (iEMG) acquisition method. By a minimally invasive surgery, a self-expanding stent sensor with microelectrode and lead was implanted into the femoral vein adjacent to the tibialis anterior muscle to record deep muscle activity. In this study, sEMG and iEMG were simultaneously acquired from sheep hindlimb muscle in standing state and walking state for comparative analysis of their electrophysiological properties. Level walking served as the dynamic locomotor task in this work. Totally, this acquisition experiment lasted for three days. In standing state, both EMG exhibit a high correlation (Spearman’s ρ = 0.9018, p < 0.001). In walking state, iEMG demonstrates a 10.04% higher signal-to-noise ratio compared to sEMG. Additionally, iEMG shows a 33.82% lower coefficient of variation in power spectral density than sEMG, indicating a 1.51-fold improvement in signal stability. These results demonstrate that our iEMG acquisition method enables high-quality and robust recordings for long-term monitoring during walking, which provides a reliable foundation for clinical rehabilitation applications requiring precise, long-term muscle activity tracking.
- 17 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (1) , 1147-1155
A Wireless Neural Signal Acquisition System for Interventional Brain–Computer Interface
Interventional brain-computer interfaces represent a promising approach for neural signal acquisition by placing electrodes within cerebral blood vessels, offering superior signal fidelity compared to surface recordings while avoiding the risks of direct brain tissue penetration. However, traditional neural recording systems require hardware and wired connections, limiting their applicability for chronic implantation in interventional scenarios. This research presents a novel wireless electroencephalography and electromyography signal acquisition system specifically engineered for interventional brain-computer interface applications. The system integrates three critical modules: electromagnetic induction-based wireless power transfer, high-fidelity signal processing via a 24-bit analog-to-digital converter and Bluetooth Low Energy wireless data transmission using the EFR32BG22 system-on-chip. Experimental validation demonstrates successful acquisition of steady-state visual evoked potentials (SSVEPs) with 78.95% classification accuracy using Support Vector Machine algorithms, and simultaneous electroencephalography-electromyogram (EEG-EMG) recording during motor tasks achieving 73.3% multi-class classification performance. Frequency domain analysis reveals less than 5% deviation compared to g.tec systems across the 0-50 Hz operational bandwidth. In-vivo validation using a sheep model with medical-grade silicone encapsulation successfully captured neural signals from transverse sinus and superior sagittal sinus electrodes during behavioral motor tasks. The biocompatible and miniaturized design enables chronic implantation while maintaining clinical-grade signal quality and real-time communication capabilities, establishing a novel device for interventional brain-computer interface applications.
- 17 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (1) , 1147-1155
A Wireless Neural Signal Acquisition System for Interventional Brain–Computer Interface
Interventional brain-computer interfaces represent a promising approach for neural signal acquisition by placing electrodes within cerebral blood vessels, offering superior signal fidelity compared to surface recordings while avoiding the risks of direct brain tissue penetration. However, traditional neural recording systems require hardware and wired connections, limiting their applicability for chronic implantation in interventional scenarios. This research presents a novel wireless electroencephalography and electromyography signal acquisition system specifically engineered for interventional brain-computer interface applications. The system integrates three critical modules: electromagnetic induction-based wireless power transfer, high-fidelity signal processing via a 24-bit analog-to-digital converter and Bluetooth Low Energy wireless data transmission using the EFR32BG22 system-on-chip. Experimental validation demonstrates successful acquisition of steady-state visual evoked potentials (SSVEPs) with 78.95% classification accuracy using Support Vector Machine algorithms, and simultaneous electroencephalography-electromyogram (EEG-EMG) recording during motor tasks achieving 73.3% multi-class classification performance. Frequency domain analysis reveals less than 5% deviation compared to g.tec systems across the 0-50 Hz operational bandwidth. In-vivo validation using a sheep model with medical-grade silicone encapsulation successfully captured neural signals from transverse sinus and superior sagittal sinus electrodes during behavioral motor tasks. The biocompatible and miniaturized design enables chronic implantation while maintaining clinical-grade signal quality and real-time communication capabilities, establishing a novel device for interventional brain-computer interface applications.
- Open Access
- 21 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 1633-1642
An Interventional Brain-Computer Interface for Long-Term EEG Collection and Motion Classification of a Quadruped Mammal
Brain-computer interfaces (BCI) acquire electroencephalogram (EEG) signals to effectively address postoperative motor dysfunction in stroke patients by discerning their motor intentions during significant movements. Traditionally, noninvasive BCIs have been constrained by limitations in their usage environments; whereas, invasive BCIs damage neural permanently. Therefore, we proposed a novel interventional BCI, in which electrodes are implanted along the veins into the brain to acquire intracerebral EEG signals without an open craniotomy. We collect EEG signals from the primary motor cortex in the superior sagittal sinus of sheep during three different significant movements: laying down; standing; and walking. The first three month data are used to train the neural network, and The fourth month of data were used to validate. The deep learning model achieved an 86% accuracy rate in classifying motion states in validation. Furthermore, the results of the power spectral density (PSD) show that the signal power in the main frequency band did not decrease over a period of five months, which demonstrates that the interventional BCI has the ability to effectively capture EEG signals over long periods of time.
- 21 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 1633-1642
Open AccessAn Interventional Brain-Computer Interface for Long-Term EEG Collection and Motion Classification of a Quadruped Mammal
Brain-computer interfaces (BCI) acquire electroencephalogram (EEG) signals to effectively address postoperative motor dysfunction in stroke patients by discerning their motor intentions during significant movements. Traditionally, noninvasive BCIs have been constrained by limitations in their usage environments; whereas, invasive BCIs damage neural permanently. Therefore, we proposed a novel interventional BCI, in which electrodes are implanted along the veins into the brain to acquire intracerebral EEG signals without an open craniotomy. We collect EEG signals from the primary motor cortex in the superior sagittal sinus of sheep during three different significant movements: laying down; standing; and walking. The first three month data are used to train the neural network, and The fourth month of data were used to validate. The deep learning model achieved an 86% accuracy rate in classifying motion states in validation. Furthermore, the results of the power spectral density (PSD) show that the signal power in the main frequency band did not decrease over a period of five months, which demonstrates that the interventional BCI has the ability to effectively capture EEG signals over long periods of time.
- 31 August 2021
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11907, 27
Depth imaging through realistic fog using Gm-APD Lidar
When using Gm-APD Lidar for depth imaging through realistic fog, the echo signal of the target is submerged in the background noise due to the strong absorption and scattering characteristics of the fog particles, resulting in serious defect of the recovered depth image of the target. To solve this problem, this paper proposes a dual-parameter estimation algorithm based on continuous wavelet transform (CWT) and maximum likelihood estimation (MLE) to improve the accuracy of fog signal estimation. Then the target and the fog signal are separated by estimating the fog signal of each pixel. Finally, the depth image of the separated target is processed by cross pixel complement and median filtering algorithms to improve the integrity of the target image. The experimental results show that, compared with the traditional algorithm, the target recovery of the reconstructed image is improved by 0.337, and the relative average ranging error is reduced by 0.3897. This research improves the weather adaptability of Gm-APD Lidar.
- 31 August 2021
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11907, 27
Depth imaging through realistic fog using Gm-APD Lidar
When using Gm-APD Lidar for depth imaging through realistic fog, the echo signal of the target is submerged in the background noise due to the strong absorption and scattering characteristics of the fog particles, resulting in serious defect of the recovered depth image of the target. To solve this problem, this paper proposes a dual-parameter estimation algorithm based on continuous wavelet transform (CWT) and maximum likelihood estimation (MLE) to improve the accuracy of fog signal estimation. Then the target and the fog signal are separated by estimating the fog signal of each pixel. Finally, the depth image of the separated target is processed by cross pixel complement and median filtering algorithms to improve the integrity of the target image. The experimental results show that, compared with the traditional algorithm, the target recovery of the reconstructed image is improved by 0.337, and the relative average ranging error is reduced by 0.3897. This research improves the weather adaptability of Gm-APD Lidar.
- Open Access
- 11 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 205436-205443
A Combined Low-Rank Matrix Completion and CDBN-LSTM Based Classification Model for Lower Limb Motion Function
Assessment of lower limb motion function is crucial for clinicians to treat patients effectively. However, diagnosis accuracy is still affected by clinical experience. To reduce the influence of subjective factors, a new classification model using conditional deep belief network (CDBN) and long short-term memory (LSTM) is proposed. Firstly, the original data of gait are collected by motion capture system, and low-rank matrix completion is utilized to reconstruct missing data caused by the interruption of hands and clothes. Then CDBN is trained for extracting features and LSTM classifies the features from the completed data. Compared with deep belief network (DBN), CDBN is based on conditional restricted Boltzmann machine (CRBM) which improves the importance of past time-step to achieve higher accuracy for temporal sequences. And LSTM classifies features with time information. The matrix completion result verifies excellent recovery accuracy of the proposed method. Experimental results demonstrate that CDBN-LSTM is 4% higher than that of DBN. In addition, the proposed model outperforms traditional neural network on the train process and precision rate.
- 11 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 205436-205443
Open AccessA Combined Low-Rank Matrix Completion and CDBN-LSTM Based Classification Model for Lower Limb Motion Function
Assessment of lower limb motion function is crucial for clinicians to treat patients effectively. However, diagnosis accuracy is still affected by clinical experience. To reduce the influence of subjective factors, a new classification model using conditional deep belief network (CDBN) and long short-term memory (LSTM) is proposed. Firstly, the original data of gait are collected by motion capture system, and low-rank matrix completion is utilized to reconstruct missing data caused by the interruption of hands and clothes. Then CDBN is trained for extracting features and LSTM classifies the features from the completed data. Compared with deep belief network (DBN), CDBN is based on conditional restricted Boltzmann machine (CRBM) which improves the importance of past time-step to achieve higher accuracy for temporal sequences. And LSTM classifies features with time information. The matrix completion result verifies excellent recovery accuracy of the proposed method. Experimental results demonstrate that CDBN-LSTM is 4% higher than that of DBN. In addition, the proposed model outperforms traditional neural network on the train process and precision rate.
- Open Access
- 1 July 2014
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 12 (7)
Lower limb motor function assessment based on TensorFlow convolutional neural network and kernel entropy component analysis–local tangent space alignment
Motor function assessment of patients and the elderly is crucial to gait assessment and gait rehabilitation. Accuracy of the assessment is affected by clinician’s experience. To solve the problem, this article proposes motor function assessment index to assess the motor function of patients. VICON system collects video of subjects when they are walking. And the original gait videos are pre-processed by the pixel-based adaptive segmenter and extracted by the convolutional neural network. The kernel entropy component analysis and local tangent space alignment reduced the dimensions of extracted features, and motor function assessment index is obtained. The Pearson correlation analysis shows that the motor function assessment index and modified gait abnormality rating scale are significantly correlated, and Pearson correlation coefficient is 0.92. These effectiveness results demonstrate that the proposed method has the considerable potential to promote the future design of automatic motor function assessment for clinical rehabilitation research.
- 1 July 2014
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 12 (7)
Open AccessLower limb motor function assessment based on TensorFlow convolutional neural network and kernel entropy component analysis–local tangent space alignment
Motor function assessment of patients and the elderly is crucial to gait assessment and gait rehabilitation. Accuracy of the assessment is affected by clinician’s experience. To solve the problem, this article proposes motor function assessment index to assess the motor function of patients. VICON system collects video of subjects when they are walking. And the original gait videos are pre-processed by the pixel-based adaptive segmenter and extracted by the convolutional neural network. The kernel entropy component analysis and local tangent space alignment reduced the dimensions of extracted features, and motor function assessment index is obtained. The Pearson correlation analysis shows that the motor function assessment index and modified gait abnormality rating scale are significantly correlated, and Pearson correlation coefficient is 0.92. These effectiveness results demonstrate that the proposed method has the considerable potential to promote the future design of automatic motor function assessment for clinical rehabilitation research.