Yuyan Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yuyan Yu has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Chun Hui Wang
School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, Australia
5 shared publications - Shuhua Peng
School of Mechanical and Manufacturing Engineering The University of New South Wales Sydney New South Wales Australia
5 shared publications - Mohammad Saiful Islam
School of Mechanical and Manufacturing Engineering, The University of New South Wales, Sydney, NSW, 2052, Australia
2 shared publications Philippe Blanloeuil
2 shared publicationsShuying Wu
School of Engineering, Macquarie University, Sydney, New South Wales 2109, Australia
2 shared publications- Shuying Wu
School of Aerospace Mechanical and Mechatronic Engineering The University of Sydney Sydney New South Wales Australia
2 shared publications
Latest Publications
- Open Access
- 20 November 2022
- Published by Wiley in Advanced Materials Technologies
- Vol. 8 (4)
Wearable Supercapacitive Temperature Sensors with High Accuracy Based on Ionically Conductive Organogel and Macro‐Kirigami Electrode
Wearable temperature sensors with high accuracy are critical for human health monitoring. Ideally, they should show accuracy matching that of medical‐grade thermometers (i.e., ± ≈0.1–0.2 °C). Achieving this goal has proven challenging for sensors that must also meet key wearable requirements, such as flexibility, stretchability, and breathability. Herein, a new stretchable supercapacitive temperature sensor with a resolution of ±0.2 °C, is presented, which was achieved by. Two new strategies to increase temperature sensitivity and minimize the interferences of mechanical stretching and pressure: a) synthesizing an ion‐conductive NaCl‐organogel to serve as the redox‐active separator to increase sensitivity and suppress interference of compression; and b) using a kirigami design to decrease the interference of stretch and improve breathability. These two novel strategies endow the supercapacitive temperature sensors with a temperature accuracy of ±0.2 °C and exceptionally high sensitivity of 0.095 °C−1, which is more than 13 times higher than traditional dielectric‐capacitive sensors. The potential of the supercapacitive sensor in measuring body temperature is demonstrated by continuously monitoring skin temperatures under a medical compression garment that exerts pressure on the skin and the unsteady wrist flexion. The findings confirm that the organogel‐based supercapacitive sensors offer an extraordinary temperature accuracy significantly better than wearable sensors reported in the literature. The combined characteristics of high resolution, linearity, breathability, and stretchability make this sensor a promising candidate for skin‐interfaced health monitoring devices.
- 20 November 2022
- Published by Wiley in Advanced Materials Technologies
- Vol. 8 (4)
Open AccessWearable Supercapacitive Temperature Sensors with High Accuracy Based on Ionically Conductive Organogel and Macro‐Kirigami Electrode
Wearable temperature sensors with high accuracy are critical for human health monitoring. Ideally, they should show accuracy matching that of medical‐grade thermometers (i.e., ± ≈0.1–0.2 °C). Achieving this goal has proven challenging for sensors that must also meet key wearable requirements, such as flexibility, stretchability, and breathability. Herein, a new stretchable supercapacitive temperature sensor with a resolution of ±0.2 °C, is presented, which was achieved by. Two new strategies to increase temperature sensitivity and minimize the interferences of mechanical stretching and pressure: a) synthesizing an ion‐conductive NaCl‐organogel to serve as the redox‐active separator to increase sensitivity and suppress interference of compression; and b) using a kirigami design to decrease the interference of stretch and improve breathability. These two novel strategies endow the supercapacitive temperature sensors with a temperature accuracy of ±0.2 °C and exceptionally high sensitivity of 0.095 °C−1, which is more than 13 times higher than traditional dielectric‐capacitive sensors. The potential of the supercapacitive sensor in measuring body temperature is demonstrated by continuously monitoring skin temperatures under a medical compression garment that exerts pressure on the skin and the unsteady wrist flexion. The findings confirm that the organogel‐based supercapacitive sensors offer an extraordinary temperature accuracy significantly better than wearable sensors reported in the literature. The combined characteristics of high resolution, linearity, breathability, and stretchability make this sensor a promising candidate for skin‐interfaced health monitoring devices.
- Open Access
- 1 November 2021
- Published by Elsevier in Materials & Design
- Vol. 210, 110076
Enabling contactless rapid on-demand debonding and rebonding using hysteresis heating of ferrimagnetic nanoparticles
- 1 November 2021
- Published by Elsevier in Materials & Design
- Vol. 210, 110076
Open AccessEnabling contactless rapid on-demand debonding and rebonding using hysteresis heating of ferrimagnetic nanoparticles
- 16 October 2021
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry A
- Vol. 9 (44) , 24874-24886
High-precision, stretchable kirigami-capacitive sensor with ultra-low cross-sensitivity for body temperature monitoring
Wearable temperature sensors meeting the resolution of medical-grade thermometers are needed to continuously monitor skin temperature variations indicative of diseases and sports performance. Herein, we present a new technique for creating stretchable capacitive sensors with a temperature resolution of 0.14 °C and minimum cross-sensitivity to mechanical stretch. Two complementary strategies were employed to minimize the stretch-sensitivity and achieve high temperature resolution: (a) increasing the temperature sensitivity by using a dielectric core material of positive temperature coefficients of permittivity and thermal expansion, and (b) reducing the cross-interference of mechanical deformation by optimizing the kirigami pattern. The optimized kirigami-capacitive wearable temperature sensors with a thermoplastic polyurethane core sandwiched between electrodes made of silver nanowires exhibit a high temperature sensitivity of 0.007 °C−1 with an excellent linearity of 0.998. Computational modeling of kirigami geometry effects on strain and temperature sensitivities of capacitive sensors reveals that the optimized kirigami design can reduce the strain cross-sensitivity by a factor of 3125, which enables capacitive temperature sensors to achieve the resolution of point-of-care medical devices. The combined characteristics of high sensitivity, linearity, breathability, and stretchability make the new capacitive sensors a promising candidate for medical-grade wearable temperature sensors.
- 16 October 2021
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry A
- Vol. 9 (44) , 24874-24886
High-precision, stretchable kirigami-capacitive sensor with ultra-low cross-sensitivity for body temperature monitoring
Wearable temperature sensors meeting the resolution of medical-grade thermometers are needed to continuously monitor skin temperature variations indicative of diseases and sports performance. Herein, we present a new technique for creating stretchable capacitive sensors with a temperature resolution of 0.14 °C and minimum cross-sensitivity to mechanical stretch. Two complementary strategies were employed to minimize the stretch-sensitivity and achieve high temperature resolution: (a) increasing the temperature sensitivity by using a dielectric core material of positive temperature coefficients of permittivity and thermal expansion, and (b) reducing the cross-interference of mechanical deformation by optimizing the kirigami pattern. The optimized kirigami-capacitive wearable temperature sensors with a thermoplastic polyurethane core sandwiched between electrodes made of silver nanowires exhibit a high temperature sensitivity of 0.007 °C−1 with an excellent linearity of 0.998. Computational modeling of kirigami geometry effects on strain and temperature sensitivities of capacitive sensors reveals that the optimized kirigami design can reduce the strain cross-sensitivity by a factor of 3125, which enables capacitive temperature sensors to achieve the resolution of point-of-care medical devices. The combined characteristics of high sensitivity, linearity, breathability, and stretchability make the new capacitive sensors a promising candidate for medical-grade wearable temperature sensors.
- 13 September 2021
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 13 (37) , 43831-43854
Conductive Polymer Nanocomposites for Stretchable Electronics: Material Selection, Design, and Applications
Stretchable electronics that can elongate elastically as well as flex are crucial to a wide range of emerging technologies, such as wearable medical devices, electronic skin, and soft robotics. Critical to stretchable electronics is their ability to withstand large mechanical strain without failure while retaining their electrical conduction properties, a feat significantly beyond traditional metals and silicon-based semiconductors. Herein, we present a review of the recent advances in stretchable conductive polymer nanocomposites with exceptional stretchability and electrical properties, which have the potential to transform a wide range of applications, including wearable sensors for biophysical signals, stretchable conductors and electrodes, and deformable energy-harvesting and -storage devices. Critical to achieving these stretching properties are the judicious selection and hybridization of nanomaterials, novel microstructure designs, and facile fabrication processes, which are the focus of this Review. To highlight the potentials of conductive nanocomposites, a summary of some recent important applications is presented, including COVID-19 remote monitoring, connected health, electronic skin for augmented intelligence, and soft robotics. Finally, perspectives on future challenges and new research opportunities are also presented and discussed.
- 13 September 2021
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 13 (37) , 43831-43854
Conductive Polymer Nanocomposites for Stretchable Electronics: Material Selection, Design, and Applications
Stretchable electronics that can elongate elastically as well as flex are crucial to a wide range of emerging technologies, such as wearable medical devices, electronic skin, and soft robotics. Critical to stretchable electronics is their ability to withstand large mechanical strain without failure while retaining their electrical conduction properties, a feat significantly beyond traditional metals and silicon-based semiconductors. Herein, we present a review of the recent advances in stretchable conductive polymer nanocomposites with exceptional stretchability and electrical properties, which have the potential to transform a wide range of applications, including wearable sensors for biophysical signals, stretchable conductors and electrodes, and deformable energy-harvesting and -storage devices. Critical to achieving these stretching properties are the judicious selection and hybridization of nanomaterials, novel microstructure designs, and facile fabrication processes, which are the focus of this Review. To highlight the potentials of conductive nanocomposites, a summary of some recent important applications is presented, including COVID-19 remote monitoring, connected health, electronic skin for augmented intelligence, and soft robotics. Finally, perspectives on future challenges and new research opportunities are also presented and discussed.
- 15 July 2020
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 12 (32) , 36578-36588
Wearable Temperature Sensors with Enhanced Sensitivity by Engineering Microcrack Morphology in PEDOT:PSS–PDMS Sensors
Wearable temperature sensors with high sensitivity, linearity, and flexibility are required to meet the increasing demands for unobtrusive monitoring of temperature changes indicative of the onset of infections and diseases. Herein, we present a new method for engineering highly sensitive and flexible temperature sensors made of poly(3,4-ethylenedioxythiophene):polystyrene (PEDOT:PSS) film on a Poly(dimethylsiloxane) (PDMS) substrate. Sensors’ temperature sensitivity is strongly influenced by the length and density of microcracks, which can be engineered by controlling three key parameters: (a) pre-stretching strain, (b) sulfuric acid treatment time, and (c) surface roughness of the substrate. Specifically, pre-stretching can induce cracks in PEDOT:PSS layer while high pre-stretching strain results in cracks with both increased density and length. A smooth PDMS substrate tends to yield long and straight cracks in the PEDOT:PSS film, compared to shorter microcracks with higher density on rough surfaces. Crack density can be further increased via sulfuric acid treatment with the optimum duration of approximately 3 hours. Prolonged treatment would result in weak adhesion between the PEDOT:PSS and PDMS substrate, which in turn reduces the microcrack density but increases the crack length. The optimum PEDOT:PSS-PDMS sensor provides a combined high temperature sensitivity of 0.042 ⁰C-1 with excellent linearity of 0.998 (from 30 °C to 55 °C). With a good optical transparency, high temperature sensitivity, excellent linearity as well as high flexibility, this microcrack-based sensor is a very promising wearable temperature sensing solution.
- 15 July 2020
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 12 (32) , 36578-36588
Wearable Temperature Sensors with Enhanced Sensitivity by Engineering Microcrack Morphology in PEDOT:PSS–PDMS Sensors
Wearable temperature sensors with high sensitivity, linearity, and flexibility are required to meet the increasing demands for unobtrusive monitoring of temperature changes indicative of the onset of infections and diseases. Herein, we present a new method for engineering highly sensitive and flexible temperature sensors made of poly(3,4-ethylenedioxythiophene):polystyrene (PEDOT:PSS) film on a Poly(dimethylsiloxane) (PDMS) substrate. Sensors’ temperature sensitivity is strongly influenced by the length and density of microcracks, which can be engineered by controlling three key parameters: (a) pre-stretching strain, (b) sulfuric acid treatment time, and (c) surface roughness of the substrate. Specifically, pre-stretching can induce cracks in PEDOT:PSS layer while high pre-stretching strain results in cracks with both increased density and length. A smooth PDMS substrate tends to yield long and straight cracks in the PEDOT:PSS film, compared to shorter microcracks with higher density on rough surfaces. Crack density can be further increased via sulfuric acid treatment with the optimum duration of approximately 3 hours. Prolonged treatment would result in weak adhesion between the PEDOT:PSS and PDMS substrate, which in turn reduces the microcrack density but increases the crack length. The optimum PEDOT:PSS-PDMS sensor provides a combined high temperature sensitivity of 0.042 ⁰C-1 with excellent linearity of 0.998 (from 30 °C to 55 °C). With a good optical transparency, high temperature sensitivity, excellent linearity as well as high flexibility, this microcrack-based sensor is a very promising wearable temperature sensing solution.