Michael D. Nowak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Michael D. Nowak has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
- Melissa Randy Gitman
Icahn School of Medicine at Mount Sinai
7 shared publications - Emilia Mia Sordillo
Department of Pathology, Molecular and Cell-Based Medicine, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA
5 shared publications - Alberto Enrique Paniz-Mondolfi
Department of Pathology, Molecular and Cell-Based Medicine, Icahn School of Medicine at Mount Sinai, New York, NY, USA
4 shared publications - Matthew M. Hernandez
Department of Pathology, Molecular, and Cell‐Based Medicine Icahn School of Medicine at Mount Sinai New York New York USA
2 shared publications Shelcie Fabre
Clinical Microbiology Laboratory, Department of Pathology, Molecular, and Cell‐Based Medicine Icahn School of Medicine at Mount Sinai New York New York USA
2 shared publicationsA. E. Götz
Universitätsklinik Hamburg-Eppendorf
1 shared publication
Latest Publications
- 16 May 2025
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 46 (6) , 650-653
Electronic clinical decision support system guided blood culture stewardship in emergency departments: response to the national blood culture media shortage
CDSS-guided stewardship in six EDs during national culture bottles shortage was associated with significant reduction in median daily blood culture utilization per 1,000 ED visits from 141.5 (IQR:127.6–155.3) to 77.9 (IQR:68.3–86.3) and increased diagnostic yield from 6.2%(IQR:4.7%–7.6%) to 8.8%(IQR:6.1%–11.5%), without impacting length of stay or mortality.
- 16 May 2025
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 46 (6) , 650-653
Electronic clinical decision support system guided blood culture stewardship in emergency departments: response to the national blood culture media shortage
CDSS-guided stewardship in six EDs during national culture bottles shortage was associated with significant reduction in median daily blood culture utilization per 1,000 ED visits from 141.5 (IQR:127.6–155.3) to 77.9 (IQR:68.3–86.3) and increased diagnostic yield from 6.2%(IQR:4.7%–7.6%) to 8.8%(IQR:6.1%–11.5%), without impacting length of stay or mortality.
- Open Access
- 15 May 2025
- Published by Oxford University Press (OUP) in Open Forum Infectious Diseases
- Vol. 12 (6) , ofaf297
Importance of Verifying the Cycle Threshold for Positive Results From Xpert MTB/RIF Assay, Performed on the GeneXpert Instrument Systems
Providers need to be aware of the potential causes of false positive Xpert TB test results, this letter provides a practical approach to confirm and differentiate between a true positive by reviewing that all probes are positive and the Ct values have reached a certain threshold.
- 15 May 2025
- Published by Oxford University Press (OUP) in Open Forum Infectious Diseases
- Vol. 12 (6) , ofaf297
Open AccessImportance of Verifying the Cycle Threshold for Positive Results From Xpert MTB/RIF Assay, Performed on the GeneXpert Instrument Systems
Providers need to be aware of the potential causes of false positive Xpert TB test results, this letter provides a practical approach to confirm and differentiate between a true positive by reviewing that all probes are positive and the Ct values have reached a certain threshold.
- Open Access
- 1 June 2021
- Published by Elsevier in Medical Mycology Case Reports
- Vol. 32, 73-76
First report of human infection caused by Colletotrichum chlorophyti occurring in a post-corneal transplant patient with endophthalmitis
- 1 June 2021
- Published by Elsevier in Medical Mycology Case Reports
- Vol. 32, 73-76
Open AccessFirst report of human infection caused by Colletotrichum chlorophyti occurring in a post-corneal transplant patient with endophthalmitis
- Open Access
- 8 May 2021
- Published by Wiley in Journal of Medical Virology
- Vol. 93 (9) , 5481-5486
RT‐PCR/MALDI‐TOF mass spectrometry‐based detection of SARS‐CoV‐2 in saliva specimens
As severe acute respiratory syndrome coronavirus‐2 (SARS‐CoV‐2) infections continue, there is a substantial need for cost‐effective and large‐scale testing that utilizes specimens that can be readily collected from both symptomatic and asymptomatic individuals in various community settings. Although multiple diagnostic methods utilize nasopharyngeal specimens, saliva specimens represent an attractive alternative as they can rapidly and safely be collected from different populations. While saliva has been described as an acceptable clinical matrix for the detection of SARS‐CoV‐2, evaluations of analytic performance across platforms for this specimen type are limited. Here, we used a novel sensitive RT‐PCR/MALDI‐TOF mass spectrometry‐based assay (Agena MassARRAY®) to detect SARS‐CoV‐2 in saliva specimens. The platform demonstrated high diagnostic sensitivity and specificity when compared to matched patient upper respiratory specimens. We also evaluated the analytical sensitivity of the platform and determined the limit of detection of the assay to be 1562.5 copies/ml. Furthermore, across the five individual target components of this assay, there was a range in analytic sensitivities for each target with the N2 target being the most sensitive. Overall, this system also demonstrated comparable performance when compared to the detection of SARS‐CoV‐2 RNA in saliva by the cobas® 6800/8800 SARS‐CoV‐2 real‐time RT‐PCR Test (Roche). Together, we demonstrate that saliva represents an appropriate matrix for SARS‐CoV‐2 detection on the novel Agena system as well as on a conventional real‐time RT‐PCR assay. We conclude that the MassARRAY® system is a sensitive and reliable platform for SARS‐CoV‐2 detection in saliva, offering scalable throughput in a large variety of clinical laboratory settings.
- 8 May 2021
- Published by Wiley in Journal of Medical Virology
- Vol. 93 (9) , 5481-5486
Open AccessRT‐PCR/MALDI‐TOF mass spectrometry‐based detection of SARS‐CoV‐2 in saliva specimens
As severe acute respiratory syndrome coronavirus‐2 (SARS‐CoV‐2) infections continue, there is a substantial need for cost‐effective and large‐scale testing that utilizes specimens that can be readily collected from both symptomatic and asymptomatic individuals in various community settings. Although multiple diagnostic methods utilize nasopharyngeal specimens, saliva specimens represent an attractive alternative as they can rapidly and safely be collected from different populations. While saliva has been described as an acceptable clinical matrix for the detection of SARS‐CoV‐2, evaluations of analytic performance across platforms for this specimen type are limited. Here, we used a novel sensitive RT‐PCR/MALDI‐TOF mass spectrometry‐based assay (Agena MassARRAY®) to detect SARS‐CoV‐2 in saliva specimens. The platform demonstrated high diagnostic sensitivity and specificity when compared to matched patient upper respiratory specimens. We also evaluated the analytical sensitivity of the platform and determined the limit of detection of the assay to be 1562.5 copies/ml. Furthermore, across the five individual target components of this assay, there was a range in analytic sensitivities for each target with the N2 target being the most sensitive. Overall, this system also demonstrated comparable performance when compared to the detection of SARS‐CoV‐2 RNA in saliva by the cobas® 6800/8800 SARS‐CoV‐2 real‐time RT‐PCR Test (Roche). Together, we demonstrate that saliva represents an appropriate matrix for SARS‐CoV‐2 detection on the novel Agena system as well as on a conventional real‐time RT‐PCR assay. We conclude that the MassARRAY® system is a sensitive and reliable platform for SARS‐CoV‐2 detection in saliva, offering scalable throughput in a large variety of clinical laboratory settings.
- Open Access
Catheter-related bloodstream infection due to biofilm-producing Capnocytophaga sputigena
- 17 July 2020
- Published by Wiley in Journal of Medical Virology
- Vol. 92 (10) , 1699-1700
Coinfection in SARS‐CoV‐2 infected patients: Where are influenza virus and rhinovirus/enterovirus?
- 17 July 2020
- Published by Wiley in Journal of Medical Virology
- Vol. 92 (10) , 1699-1700
Coinfection in SARS‐CoV‐2 infected patients: Where are influenza virus and rhinovirus/enterovirus?
- 1 March 2006
- Published by Springer Nature in Der Anaesthesist
- Vol. 55 (3) , 337-361
Perioperative Echokardiographie
Die intraoperative Echokardiographie hat sich innerhalb der Anästhesiologie und Intensivmedizin während der letzten Jahre zu einem modernen Verfahren der perioperativen kardialen Diagnostik und Patientenüberwachung entwickelt. Fortschritte in der Bildaufbereitung und die Entwicklung neuer Schallwandlertechniken für die transösophageale Echokardiographie (TEE) haben hierzu in besonderem Maß beigetragen. Durch die Einführung multiplaner TEE-Sonden mit integrierter Doppler-Echokardiographiekapazität steht dem klinisch tätigen Anästhesisten eine neue Technik zur Verfügung, um Herzkammern, Herzklappen sowie die großen Gefäße qualitativ und quantitativ zu beurteilen. Die Kenntnis der physikalisch-technischen Grundlagen der Echokardiographie ist eine wichtige Voraussetzung, um diese Technologie erfolgreich am Patienten einzusetzen. Der vorliegende Übersichtsbeitrag beschreibt die verschiedenen Formen der Echokardiographie (M-mode, 2D- und Doppler-Echokardiographie) und deren spezifische Anwendungsmöglichkeiten. Zusätzlich werden die typischen Artefakte, die bei der Anwendung von Echokardiographieverfahren auftreten können, dargestellt und deren Beurteilung, Erkennung und Vermeidung erläutert. Over the past decades, echocardiography has undergone a continuous evolution in technology that has promoted its clinical application and acceptance throughout perioperative medicine. These technological advances include improvements in transducer development that permit superior imaging quality and a wider selection of probes for epicardial, epiaortic, and surface echocardiography which can also be used in conjunction with multiplane transesophageal echocardiography. Moreover, the addition of Doppler technology and digital acquisition has secured the role of echocardiography as a valuable and relatively noninvasive diagnostic tool for the assessment of cardiovascular disease and hemodynamic monitoring throughout the perioperative period. Therefore, it has become increasingly important for perioperative physicians to understand the basic principles and underlying fundamental concepts pertaining to the technology and physics of echocardiography, as well as its inherent limitations. The current review outlines the modes and applications of different echocardiographic techniques used in perioperative echocardiography including M-mode, two-dimensional echocardiography, and Doppler assessment of blood flow. In addition, the limitations of these techniques and typical artifacts associated with the perioperative use of echocardiography are described.
- 1 March 2006
- Published by Springer Nature in Der Anaesthesist
- Vol. 55 (3) , 337-361
Perioperative Echokardiographie
Die intraoperative Echokardiographie hat sich innerhalb der Anästhesiologie und Intensivmedizin während der letzten Jahre zu einem modernen Verfahren der perioperativen kardialen Diagnostik und Patientenüberwachung entwickelt. Fortschritte in der Bildaufbereitung und die Entwicklung neuer Schallwandlertechniken für die transösophageale Echokardiographie (TEE) haben hierzu in besonderem Maß beigetragen. Durch die Einführung multiplaner TEE-Sonden mit integrierter Doppler-Echokardiographiekapazität steht dem klinisch tätigen Anästhesisten eine neue Technik zur Verfügung, um Herzkammern, Herzklappen sowie die großen Gefäße qualitativ und quantitativ zu beurteilen. Die Kenntnis der physikalisch-technischen Grundlagen der Echokardiographie ist eine wichtige Voraussetzung, um diese Technologie erfolgreich am Patienten einzusetzen. Der vorliegende Übersichtsbeitrag beschreibt die verschiedenen Formen der Echokardiographie (M-mode, 2D- und Doppler-Echokardiographie) und deren spezifische Anwendungsmöglichkeiten. Zusätzlich werden die typischen Artefakte, die bei der Anwendung von Echokardiographieverfahren auftreten können, dargestellt und deren Beurteilung, Erkennung und Vermeidung erläutert. Over the past decades, echocardiography has undergone a continuous evolution in technology that has promoted its clinical application and acceptance throughout perioperative medicine. These technological advances include improvements in transducer development that permit superior imaging quality and a wider selection of probes for epicardial, epiaortic, and surface echocardiography which can also be used in conjunction with multiplane transesophageal echocardiography. Moreover, the addition of Doppler technology and digital acquisition has secured the role of echocardiography as a valuable and relatively noninvasive diagnostic tool for the assessment of cardiovascular disease and hemodynamic monitoring throughout the perioperative period. Therefore, it has become increasingly important for perioperative physicians to understand the basic principles and underlying fundamental concepts pertaining to the technology and physics of echocardiography, as well as its inherent limitations. The current review outlines the modes and applications of different echocardiographic techniques used in perioperative echocardiography including M-mode, two-dimensional echocardiography, and Doppler assessment of blood flow. In addition, the limitations of these techniques and typical artifacts associated with the perioperative use of echocardiography are described.