Daeyoung Kong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Daeyoung Kong has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
- Hyoungsoon Lee
School of Mechanical Engineering Chung‐Ang University Seoul 06974 South Korea
9 shared publications Heungdong Kwon
4 shared publicationsMehdi Asheghi
4 shared publicationsKenneth E. Goodson
Department of Mechanical Engineering, Stanford University , Stanford, CA 94305
3 shared publicationsYunseo Kim
3 shared publicationsBongho Jang
2 shared publications
Latest Publications
- Open Access
- 20 April 2026
- Published by Elsevier in SSRN Electronic Journal
Exploring Capillary limits of Copper Wire Mesh Manifold for Area Scaling of Capillary-Driven Two-Phase Coolers
In this study, a silicon pin array coated with a copper inverse opal wick and copper wire-mesh (CWM) 3D manifold are utilized to construct capillary-driven two-phase micro-coolers. We systematically investigated the limits of area scaling using three combinations of heated area and 3D manifold footprints of (case A: 52:52 mm2), (case B: 102:102 mm2), and (Case C: 52:102 mm2), respectively. For all cases, A, B, and C, we achieved critical heat fluxes (CHF) of ≈ 220 and ≈ 440 Wcm-2 at heated-area mass fluxes of 5 and 10 g/min/cm2, respectively, with full mass flow utilization for phase change. When excess fluid is supplied to the CWM 3D manifold, for cases A and C, slightly higher CHF level of ≈ 550 Wcm-2 is achieved. At this heat flux and mass flow rate, high-speed camera images reveal the formation of a liquid-vapor phase front, indicating excess liquid that is not fully vaporized. However, for case B (102:102 mm2), the CHF value is pinned at ≈ 440 Wcm-2, which indicates that CWM 3D manifold operates near its capillary limit, as the viscous pressure drop is highly non-linear for higher mass flow rates along CWM for the larger footprint CWM 3D manifold. At the most efficient operating point, the coolers achieved two-phase heat transfer coefficients, HTC2-φ ranging from 0.4 to 0.5 MWm-2℃-1 for cases A and B. The findings in this study provide crucial geometric design criteria for optimizing the hydraulic performance of two-phase micro-coolers utilizing capillary-based 3D manifold and high-performance porous wick.
- 20 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessExploring Capillary limits of Copper Wire Mesh Manifold for Area Scaling of Capillary-Driven Two-Phase Coolers
In this study, a silicon pin array coated with a copper inverse opal wick and copper wire-mesh (CWM) 3D manifold are utilized to construct capillary-driven two-phase micro-coolers. We systematically investigated the limits of area scaling using three combinations of heated area and 3D manifold footprints of (case A: 52:52 mm2), (case B: 102:102 mm2), and (Case C: 52:102 mm2), respectively. For all cases, A, B, and C, we achieved critical heat fluxes (CHF) of ≈ 220 and ≈ 440 Wcm-2 at heated-area mass fluxes of 5 and 10 g/min/cm2, respectively, with full mass flow utilization for phase change. When excess fluid is supplied to the CWM 3D manifold, for cases A and C, slightly higher CHF level of ≈ 550 Wcm-2 is achieved. At this heat flux and mass flow rate, high-speed camera images reveal the formation of a liquid-vapor phase front, indicating excess liquid that is not fully vaporized. However, for case B (102:102 mm2), the CHF value is pinned at ≈ 440 Wcm-2, which indicates that CWM 3D manifold operates near its capillary limit, as the viscous pressure drop is highly non-linear for higher mass flow rates along CWM for the larger footprint CWM 3D manifold. At the most efficient operating point, the coolers achieved two-phase heat transfer coefficients, HTC2-φ ranging from 0.4 to 0.5 MWm-2℃-1 for cases A and B. The findings in this study provide crucial geometric design criteria for optimizing the hydraulic performance of two-phase micro-coolers utilizing capillary-based 3D manifold and high-performance porous wick.
- 2 September 2025
- Published by ASME International in Journal of Electronic Packaging
- Vol. 147 (4)
Computational Fluid Dynamics Modeling and Optimization of Large-Scale (3 CM × 3 CM) Silicon-Based Embedded Microchannels With Three-Dimensional Manifold Microcoolers
The continuing increase in central processing unit and graphic processing unit performances can be attributed mostly to the rise in frequency, scaling of chip area (bigger dies), advancements in thermal management, and improvements in thermal design power, among other factors. Over the past two decades, the size of a typical graphic processing unit die has increased from 100 mm2 to ∼800 mm2 in the year 2020. Silicon-based single-phase embedded microchannels with a large area of 30 mm × 30 mm, featuring three-dimensional (3D) manifold (MF) μ-coolers, can potentially remove heat and minimize pressure drop. However, previous computational fluid dynamics simulation findings indicated considerable temperature nonuniformity resulting in increased thermal resistance and maximum temperature. The primary cause of temperature nonuniformity is the abrupt flow acceleration at the entrance and sudden deceleration at the end section of the 3D-manifold inlet channels. This leads to a significant temperature rise in the middle region of the microcooler. In this study, we introduce innovative microcooler designs and conduct extensive computational fluid dynamics simulation to achieve low thermal resistance, low-pressure drop, and crucially, uniform temperature distribution across the entire surface area of the microprocessor. To deal with this issue, our initial approach involved integrating converging inlet and diverging outlet channels into the 3D manifold. Although this method effectively dealt with nonuniformity throughout the μ-cooler's area, it still resulted in a large pressure drop. Consequently, we implemented a narrow opening at the end of the inlet channels in the 3D manifold. This allows a portion of the coolant (50–80%) to bypass the microchannels in the cold plate to the exit plenum. As a result, the pressure was reduced by ∼66% compared to the conventional 3D manifold microchannel cooler.
- 2 September 2025
- Published by ASME International in Journal of Electronic Packaging
- Vol. 147 (4)
Computational Fluid Dynamics Modeling and Optimization of Large-Scale (3 CM × 3 CM) Silicon-Based Embedded Microchannels With Three-Dimensional Manifold Microcoolers
The continuing increase in central processing unit and graphic processing unit performances can be attributed mostly to the rise in frequency, scaling of chip area (bigger dies), advancements in thermal management, and improvements in thermal design power, among other factors. Over the past two decades, the size of a typical graphic processing unit die has increased from 100 mm2 to ∼800 mm2 in the year 2020. Silicon-based single-phase embedded microchannels with a large area of 30 mm × 30 mm, featuring three-dimensional (3D) manifold (MF) μ-coolers, can potentially remove heat and minimize pressure drop. However, previous computational fluid dynamics simulation findings indicated considerable temperature nonuniformity resulting in increased thermal resistance and maximum temperature. The primary cause of temperature nonuniformity is the abrupt flow acceleration at the entrance and sudden deceleration at the end section of the 3D-manifold inlet channels. This leads to a significant temperature rise in the middle region of the microcooler. In this study, we introduce innovative microcooler designs and conduct extensive computational fluid dynamics simulation to achieve low thermal resistance, low-pressure drop, and crucially, uniform temperature distribution across the entire surface area of the microprocessor. To deal with this issue, our initial approach involved integrating converging inlet and diverging outlet channels into the 3D manifold. Although this method effectively dealt with nonuniformity throughout the μ-cooler's area, it still resulted in a large pressure drop. Consequently, we implemented a narrow opening at the end of the inlet channels in the 3D manifold. This allows a portion of the coolant (50–80%) to bypass the microchannels in the cold plate to the exit plenum. As a result, the pressure was reduced by ∼66% compared to the conventional 3D manifold microchannel cooler.
- Top Cited Papers
- 20 July 2024
- Published by Elsevier in Energy Conversion and Management
- Vol. 315
Extreme heat flux cooling from functional copper inverse opal-coated manifold microchannels
- 20 July 2024
- Published by Elsevier in Energy Conversion and Management
- Vol. 315
Top Cited PapersExtreme heat flux cooling from functional copper inverse opal-coated manifold microchannels
- Open Access
- 31 March 2024
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 57, 104331
Multimodal machine learning for predicting heat transfer characteristics in micro-pin fin heat sinks
- 31 March 2024
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 57, 104331
Open AccessMultimodal machine learning for predicting heat transfer characteristics in micro-pin fin heat sinks
- 12 January 2024
- Published by Elsevier in Applied Thermal Engineering
- Vol. 241
Enhanced boiling heat transfer via microporous copper surface integration in a manifold microgap
- 12 January 2024
- Published by Elsevier in Applied Thermal Engineering
- Vol. 241
Enhanced boiling heat transfer via microporous copper surface integration in a manifold microgap
- 14 August 2023
- Published by Elsevier in Applied Thermal Engineering
- Vol. 235
Experimental and computational investigation of thermal performance and fluid flow in two-phase closed thermosyphon
- 14 August 2023
- Published by Elsevier in Applied Thermal Engineering
- Vol. 235
Experimental and computational investigation of thermal performance and fluid flow in two-phase closed thermosyphon
- 8 July 2023
- Published by Elsevier in Applied Thermal Engineering
- Vol. 233
Enhanced heat transfer in a microchannel with pseudo-roughness induced by Onsager-Wien effect
- 8 July 2023
- Published by Elsevier in Applied Thermal Engineering
- Vol. 233
Enhanced heat transfer in a microchannel with pseudo-roughness induced by Onsager-Wien effect
- Top Cited Papers
- 16 February 2023
- Published by Elsevier in International Journal of Mechanical Sciences
- Vol. 248
An additively manufactured manifold-microchannel heat sink for high-heat flux cooling
- 16 February 2023
- Published by Elsevier in International Journal of Mechanical Sciences
- Vol. 248
Top Cited PapersAn additively manufactured manifold-microchannel heat sink for high-heat flux cooling
- Open Access
- 1 December 2021
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 28
A holistic approach to thermal-hydraulic design of 3D manifold microchannel heat sinks for energy-efficient cooling
- 1 December 2021
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 28
Open AccessA holistic approach to thermal-hydraulic design of 3D manifold microchannel heat sinks for energy-efficient cooling