MAM. Shah Alam

M. Shah Alam

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


M. Shah Alam has a total of 60 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Cladding-Engineered Hollow-Core Fiber for Polarization Control and Optical Sensing Applications

    by M. M. Shoaib Hasan, Shah Alam, Selim Habib, Asiful Islam

    A polarization-selective hollow-core antiresonant fiber (HC-ARF) is proposed and numerically investigated for single-polarization guidance in the telecom band. Finite-element simulations across the 1.50–1.60 μm range show that the optimized design achieves a high polarization extinction ratio of $1.73\times 10^{4}$ at 1.55 μm, with low loss for the $y$–polarized mode (0.72 dB/km) and strongly suppressed $x$–polarized loss (12531 dB/km). The fiber also provides a modal birefringence of $0.21\times 10^{-4}$, enabling strong polarization selectivity and stable single-polarization guidance. These results indicate that the proposed PM-HC-ARF is well-suited for polarization-sensitive applications such as interferometry, sensing, and coherent communication.


  • Design of a CMOS-compatible photonic crystal biosensor for SARS-CoV-2 detection [Invited]

    by Sabbir Hasan Sohag, M. Shah Alam

    This study presents the design and optimization of a one-dimensional photonic crystal (1D PhC) biosensor tailored for the detection of SARS-CoV-2 RNA, spike RBD glycoprotein, and monoclonal IgG. By leveraging Bloch surface waves (BSW) and defect mode engineering, the proposed sensor achieves exceptional optical confinement and sharp resonance features. A systematic parameter sweep including incident angle, defect layer thickness, and total number of periods demonstrated their profound influence on sensitivity, quality factor (QF), and figure of merit (FOM). Optimal performance was achieved at an incident angle of 88°, a defect thickness of 10 F , and N =8 periods, yielding a maximum sensitivity of 2280 nm/RIU with FOM values exceeding 1.1×10 4 RIU −1 . These metrics outperform many reported photonic biosensors and confirm the device’s capability for high resolution, label-free detection of refractive index (RI) changes in COVID-19 biomarkers. The proposed architecture, based on CMOS-compatible Si/MgF 2 materials, offers a scalable and cost effective platform for next-generation point-of-care diagnostics. Beyond SARS-CoV-2, the results establish a versatile framework for tailoring 1D PhC biosensors toward a wide range of viral and biomedical targets.


  • Open Access

    Broadband CMOS-Compatible High-Performance TM-Pass Polarizer Based on Hybrid Plasmonic Ridge Waveguide

    by K. M. Mustafizur Rahman, M. Shah Alam, Asiful Islam

    We propose and numerically investigate a CMOS-compatible hybrid plasmonic ridge waveguide (HPW)-based TM-pass polarizer that combines a silicon core with an Al-doped ZnO (AZO) slab separated by a silica spacer. The hybrid structure enables strong modal coupling and selective attenuation, allowing the TM mode to propagate efficiently while the TE mode is progressively suppressed through mode hybridization along the coupling region. Comprehensive 2D and 3D finite element analysis confirms the device’s high performance and compactness. With a total footprint of only 7 μm, two optimized models are presented: Model-1 emphasizing ultra-broadband operation, and Model-2 achieving an ultra-high polarization extinction ratio (PER). The broadband model (Model-1) demonstrates PER ≥ 20 dB across 349 nm (1469–1818 nm), PER ≥ 30 dB across 255 nm (1488–1743 nm), and PER ≥ 50 dB across 127 nm (1523–1650 nm), covering the entire C, L, and U telecom bands. The high-PER model (Model-2) attains a record PER of 74.72 dB with a low insertion loss (IL) of 1.36 dB at 1550 nm. The proposed compact and fabrication-friendly designs offer an excellent trade-off among bandwidth, extinction ratio, and loss, making them strong candidates for on-chip polarization management in silicon photonic integrated circuits and broadband optical interconnects.

  • An efficient neural network for predicting supercontinuum dynamics in photonic crystal fiber

    by Rakayet Rafi, M. R. Karim, M. Shah Alam

    This study investigates the generation of supercontinuum (SC) in photonic crystal fibers (PCFs) using chalcogenide materials. For this purpose, generation and translation-based convolutional neural network (CNN) models, Gen-Net and Trans-Net, are developed to predict the spatial and temporal evolution of SC generation, based on a dataset of multiple materials with varying optical properties. Instead of relying on spectral power data across different wavelengths, spatial and temporal evolution plots are treated as images, which reduces the dataset size required for simulations. This approach allowed for efficient handling of large datasets, making it a scalable model. The dataset includes four chalcogenide materials: Ge 11.5 As 24 Se 64.5 , As 2 S 5 , As 2 Se 3 , and As 2 S 3 , and the model learns the relationship between pulse evolution and material optical properties. The unified dataset comprises supercontinuum data for the four materials, demonstrating the model’s ability to produce accurate pulse propagation responses under identical input conditions. The two models function as a two-stage platform for modeling pulse propagation. The models’ performance was evaluated using Average Pixel Deviation (APD), yielding values close to 0.03, indicating high precision in capturing nonlinear dynamics. Furthermore, the models achieved computational speeds nearly 330 times faster than numerical methods, marking a significant advance in modeling nonlinear optics and offering valuable insights for future research in photonic device applications.


  • Open Access

    Numerical analysis of a LiF-Ge based 1D photonic crystal biosensor for detection of cancer cells

    by Sabbir Hasan Sohag, Ahmed Rayhan, Zuhaina Islam Bushra, Shah Ali Rafi, M Shah Alam

    The early and accurate detection of cancer cells is crucial for improving patient outcomes, yet conventional diagnostic methods often suffer from invasiveness, high costs, and delayed results. This research presents a biosensor based on one dimensional photonic crystal that can identify cancer cells in real time without labels by using their unique refractive index (RI) characteristics. The proposed structure, air / ( LiF / Ge ) N / 2 Defect / ( LiF / Ge ) N / 2 substrate , incorporates a defect layer infiltrated with cancer cell analytes, enabling precise RI based differentiation between healthy and malignant cells (basal, cervical, and breast cancer). Leveraging the transfer matrix method with transverse electric polarization, the sensor achieves exceptional performance metrics, including an average sensitivity of 2747.37 nmRIU − 1 at an 88 ∘ incident angle. Optimizations in defect thickness, central wavelength ( λ c = 2000 nm ), and periodicity ( N = 10) ensure robust light analyte interaction, yielding an average quality factor of 53 475.5 and an average figure of merit of 64 819 p RIU − 1 . The sensor’s fabrication feasibility is studied and the structural tolerance is verified for ± 10 % variations in the thickness of constituent materials. This work advances photonic biosensing by offering a scalable, high resolution platform for early cancer diagnosis, aligning with global healthcare sustainability goals.


  • Open Access

    Multifunctional THz Absorber Using a Hybrid VO2-Graphene Metasurface: Modeling and Performance Analysis

    by Rezwan Ahmed, Samiul Habib, Nguyen Hoang Hai, Oishi Jyoti, Ishraq Bintul Islam, Robiul Hasan, M. Shah Alam

    We present a tunable terahertz metamaterial absorber featuring a fabrication-convenient structure that combines a vanadium dioxide (VO2) square patch and a graphene loop for multifunctional operation. This paper demonstrates an absorber that can selectively operate in narrow-band, dual-band, or broad-band modes. Combining graphene’s electrical tunability with VO2’s thermally induced phase transitions, this absorber realizes dynamically switchable and tunable absorption properties. When VO2 is in its metallic state with chemical potential of graphene, Ef = 0 eV, and relaxation time, $\tau $ = 0.1 ps, the structure achieves a broad-band absorption bandwidth of 6.31 THz (¿90% absorptance from 5.04 THz to 11.35 THz), with an average absorption of 97.24% and a relative absorption bandwidth of 77.12%. By adjusting graphene’s Ef to 1 eV and $\tau $ to 0.7 ps, the absorber transitions to a dual-band response, exhibiting peak absorptions of 91.13% at 2.62 THz and 95.48% at 10.81 THz. Conversely, when VO2 remains in insulating state and graphene’s Ef is tuned to 0.6 eV and $\tau $ to 0.2 ps, a narrow-band absorption peak of 98.18% emerges. Furthermore, we demonstrate the narrow-band configuration as an ultra-sensitive biosensor, where the resonance peak undergoes a significant redshift while maintaining high absorption efficiency with minimal changes in the surrounding medium’s refractive index. The design exhibits polarization insensitivity and wide-angle stability, validated through electric field analysis, impedance matching theory, and equivalent circuit modeling. To the best of our knowledge, this is the first reported structure to integrate such a wide absorption bandwidth of 6.31 THz with ultra-high biosensing sensitivity of 1929 GHz/RIU in a single fabrication-friendly configuration. These capabilities make the absorber highly promising for applications in energy harvesting, stealth technology, and biochemical sensing.