TNTran N. H. Nguyen

Tran N. H. Nguyen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tran N. H. Nguyen has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Low-cost robotic manipulation of live microtissues for cancer drug testing

    by Ivan Stepanov, Noah R. Gottshall, Alireza Ahmadianyazdi, Daksh Sinha, Ethan J. Lockhart, Tran N. H. Nguyen, Sarmad Hassan, Lisa F. Horowitz, Raymond S. Yeung, Taranjit S. Gujral, et al.

    The scarcity of human biopsies available for drug testing is a paramount challenge for developing therapeutics, disease models, and personalized treatments. Microtechnologies that combine the microscale manipulation of tissues and fluids offer the exciting possibility of miniaturizing both disease models and drug testing workflows on scarce human biopsies. Unfortunately, these technologies presently require microfluidic devices or robotic dispensers that are not widely accessible. We have rapidly prototyped an inexpensive platform based on an off-the-shelf robot that can microfluidically manipulate live microtissues into/out of culture plates without using complicated accessories such as microscopes or pneumatic controllers. The robot integrates complex functions with a simple, cost-effective, and compact construction, allowing placement inside a tissue culture hood for sterile workflows. We demonstrated a proof-of-concept cancer drug evaluation workflow of potential clinical utility using patient tumor biopsies with multiple drugs on 384-well plates. Our user-friendly, low-cost platform promises to make drug testing of microtissues broadly accessible to pharmaceutical, clinical, and biological laboratories.


  • Open Access

    Microfluidic Modulation of Microvasculature in Microdissected Tumors

    by Tran N. H. Nguyen, Lisa F. Horowitz, Brandon Nguyen, Ethan Lockhart, Songli Zhu, Taranjit S. Gujral, Albert Folch

    The microvasculature within the tumor microenvironment (TME) plays an essential role in cancer signaling beyond nutrient delivery. However, it has been challenging to control the generation and/or maintenance of microvasculature in ex vivo systems, a critical step for establishing cancer models of high clinical biomimicry. There have been great successes in engineering tissues incorporating microvasculature de novo ( e.g. , organoids and organs-on-chip), but these reconstituted tissues are formed with non-native cellular and molecular components that can skew certain outcomes such as drug efficacy. Microdissected tumors, on the other hand, show promise in preserving the TME, which is key for creating cancer models that can bridge the gap between bench and bedside. However, microdissected tumors are challenging to perfuse. Here, we developed a microfluidic platform that allows for perfusing the microvasculature of microdissected tumors. We demonstrate that, compared to diffusive transport, microfluidically perfused tissues feature larger and longer microvascular structures, with a better expression of CD31, a marker for endothelial cells, as analyzed by 3D imaging. This study also explores the effects of nitric oxide pathway-related drugs on endothelial cells, which are sensitive to shear stress and can activate endothelial nitric oxide synthase, producing nitric oxide. Our findings highlight the critical role of controlled perfusion and biochemical modulation in preserving tumor microvasculature, offering valuable insights for developing more effective cancer treatments.


  • Open Access

    Label-free, real-time monitoring of cytochrome C drug responses in microdissected tumor biopsies with a multi-well aptasensor platform

    by Tran N. H. Nguyen, Lisa F. Horowitz, Timothy Krilov, Ethan Lockhart, Heidi L. Kenerson, Taranjit S. Gujral, Raymond S. Yeung, Netzahualcóyotl Arroyo-Currás, Albert Folch

    Functional assays on intact tumor biopsies can complement genomics-based approaches for precision oncology, drug testing, and organs-on-chips cancer disease models by capturing key therapeutic response determinants, such as tissue architecture, tumor heterogeneity, and the tumor microenvironment. Most of these assays rely on fluorescent labeling, a semiquantitative method best suited for single-time-point assays or labor-intensive immunostaining analysis. Here, we report integrated aptamer electrochemical sensors for on-chip, real-time monitoring of cytochrome C, a cell death indicator, from intact microdissected tissues with high affinity and specificity. The platform features a multi-well sensor layout and a multiplexed electronic setup. The aptasensors measure increases in cytochrome C in the supernatant of mouse or human microdissected tumors after exposure to various drug treatments. Because of the sensor’s high affinity, it primarily tracks rising concentrations of cytochrome C, capturing dynamic changes during apoptosis. This approach could help develop more advanced cancer disease models and apply to other complex in vitro disease models, such as organs-on-chips and organoids.


  • Printable Nonenzymatic Glucose Biosensors Using Carbon Nanotube-PtNP Nanocomposites Modified with AuRu for Improved Selectivity

    by Tran N. H. Nguyen, Xin Jin, James K. Nolan, Jian Xu, Khanh Vy H. Le, Stephanie Lam, Yi Wang, Muhammad A. Alam, Hyowon Lee

    Nonenzymatic glucose biosensors have the potential for a more reliable in vivo functionality due to the reduced risk of biorecognition element degradation. However, these novel sensing mechanisms often are nanoparticle-based and have nonlinear responses, which makes it difficult to gauge their potential utility against more conventional enzymatic biosensors. Moreover, these nonenzymatic biosensors often suffer from poor selectivity that needs to be better addressed before being used in vivo. To address these problems, here we present an amperometric nonenzymatic glucose biosensor fabricated using one-step electrodeposition of Au and Ru nanoparticles on the surface of a carbon-nanotube-based platinum–nanoparticle hybrid in conductive polymer. Using benchtop evaluations, we demonstrate that the bimetallic catalyst of Au-Ru nanoparticles can enable the nonenzymatic detection of glucose with a superior performance and stability. Furthermore, our biosensor shows good selectivity against other interferents, with a nonlinear dynamic range of 1–19 mM glucose. The Au-Ru catalyst has a conventional linear range of 1–10 mM, with a sensitivity of 0.2347 nA/(μM mm2) ± 0.0198 (n = 3) and a limit of detection of 0.068 mM (signal-to-noise, S/N = 3). The biosensor also exhibits a good repeatability and stability at 37 °C over a 3 week incubation period. Finally, we use a modified Butler–Volmer nonlinear analytical model to evaluate the impact of geometrical and chemical design parameters on our nonenzymatic biosensor’s performance, which may be used to help optimize the performance of this class of biosensors.


  • Facile fabrication of flexible glutamate biosensor using direct writing of platinum nanoparticle-based nanocomposite ink

    by Tran N.H. Nguyen, James K. Nolan, Hyunsu Park, Stephanie Lam, Mara Fattah, Jessica C. Page, Hang-Eun Joe, Martin B.G. Jun, Hyungwoo Lee, Sang Joon Kim, et al.