Ramona Mögling
Research Subjects
Research Interests
Ramona Mögling has a total of 87 co-authors. Here are the top co-authors by number of shared publications:
- Chantal B. E. M. Reusken
Centre for Infectious Disease Control, National Institute for Public Health and the Environment, 3721 MA Bilthoven, The Netherlands
7 shared publications Adam Meijer
Centre for Infectious Disease Control, National Institute for Public Health and the Environment (RIVM)
4 shared publicationsAngeliki Melidou
European Centre for Disease Prevention and Control (ECDC), Stockholm, Sweden
3 shared publicationsChristian Drosten
Institute of Virology, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humbolt-Universität zu Berlin
3 shared publications- Jan Felix Drexler
Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Institute of Virology, Berlin, Germany
3 shared publications - Kamelia R. Stanoeva
Centre for Infectious Disease Control, National Institute for Public Health and the Environment (RIVM)
3 shared publications
Latest Publications
- Open Access
- 9 April 2025
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 63 (4)
External quality assessment of molecular detection and variant typing of SARS-CoV-2 in European expert laboratories in 2023
The COVID-19 pandemic highlighted the importance of laboratory preparedness. Regular monitoring of diagnostic tools via external quality assessments (EQAs) is key to maintaining robust public health response service. We hereby conducted a third SARS-CoV-2 EQA assessing the diagnostic capabilities of European expert public health laboratories. A 10 samples panel containing Alpha (used in previous EQA), BA.4, BA.5, and BQ.1.18 variants along with human seasonal coronaviruses and negative controls was produced and validated. Participants were invited by the European Centre for Disease Prevention and Control (ECDC) and asked to submit results and assay details via electronic forms. Thirty-eight laboratories from 31 European countries participated. Most ( n = 32, 84%) identified all panel samples correctly and used in-house (11, 29%), commercial assays (22, 58%), or both (5, 13%). Compared to previous EQAs, correct detection of the SARS-CoV-2 samples in the panels increased: 8 (12%) in 2020, 45 (75%) in 2021, and 34 (90%) laboratories in 2023, respectively. The number of participants decreased to an average of one laboratory per country (range 1–3) compared to two (1–7) laboratories in both previous EQAs. The usage of commercial assays gradually increased in contrast to the usage of in-house or both approaches. The capacity for SARS-CoV-2 molecular diagnostics has markedly improved in Europe as evidenced by three consecutive EQAs carried out by expert public health laboratories. Routine monitoring of diagnostic and surveillance assays via EQAs remains key to maintaining rapid public health laboratory response systems. IMPORTANCE: External quality assessments (EQAs) are crucial to ensure the reliability and consistency of diagnostic laboratories. They provide an objective framework for evaluating the performance of testing systems, enabling laboratories to identify weaknesses and implement improvements promptly. In the context of SARS-CoV-2, EQAs have become even more critical due to the high demand for accurate molecular diagnostics and the emergence of new variants. Accurate detection and typing of variants are especially essential for monitoring viral evolution. EQAs help standardize methodologies, ensuring that results across laboratories remain comparable and trustworthy. Moreover, they play a pivotal role in minimizing errors such as false positives or negatives. In this rapidly evolving landscape, regular EQAs are indispensable for maintaining high-quality standards in molecular diagnostics and variant surveillance. We demonstrate here that regular EQAs improve the molecular detection of SARS-CoV-2 in European laboratories.
- 9 April 2025
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 63 (4)
Open AccessExternal quality assessment of molecular detection and variant typing of SARS-CoV-2 in European expert laboratories in 2023
The COVID-19 pandemic highlighted the importance of laboratory preparedness. Regular monitoring of diagnostic tools via external quality assessments (EQAs) is key to maintaining robust public health response service. We hereby conducted a third SARS-CoV-2 EQA assessing the diagnostic capabilities of European expert public health laboratories. A 10 samples panel containing Alpha (used in previous EQA), BA.4, BA.5, and BQ.1.18 variants along with human seasonal coronaviruses and negative controls was produced and validated. Participants were invited by the European Centre for Disease Prevention and Control (ECDC) and asked to submit results and assay details via electronic forms. Thirty-eight laboratories from 31 European countries participated. Most ( n = 32, 84%) identified all panel samples correctly and used in-house (11, 29%), commercial assays (22, 58%), or both (5, 13%). Compared to previous EQAs, correct detection of the SARS-CoV-2 samples in the panels increased: 8 (12%) in 2020, 45 (75%) in 2021, and 34 (90%) laboratories in 2023, respectively. The number of participants decreased to an average of one laboratory per country (range 1–3) compared to two (1–7) laboratories in both previous EQAs. The usage of commercial assays gradually increased in contrast to the usage of in-house or both approaches. The capacity for SARS-CoV-2 molecular diagnostics has markedly improved in Europe as evidenced by three consecutive EQAs carried out by expert public health laboratories. Routine monitoring of diagnostic and surveillance assays via EQAs remains key to maintaining rapid public health laboratory response systems. IMPORTANCE: External quality assessments (EQAs) are crucial to ensure the reliability and consistency of diagnostic laboratories. They provide an objective framework for evaluating the performance of testing systems, enabling laboratories to identify weaknesses and implement improvements promptly. In the context of SARS-CoV-2, EQAs have become even more critical due to the high demand for accurate molecular diagnostics and the emergence of new variants. Accurate detection and typing of variants are especially essential for monitoring viral evolution. EQAs help standardize methodologies, ensuring that results across laboratories remain comparable and trustworthy. Moreover, they play a pivotal role in minimizing errors such as false positives or negatives. In this rapidly evolving landscape, regular EQAs are indispensable for maintaining high-quality standards in molecular diagnostics and variant surveillance. We demonstrate here that regular EQAs improve the molecular detection of SARS-CoV-2 in European laboratories.
- Open Access
- 31 January 2025
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 63 (1) , e0091024
Excellent capability for molecular detection of Aedes -borne dengue, Zika, and chikungunya viruses but with a need for increased capacity for yellow fever and Japanese encephalitis viruses: an external quality assessment in 36 European laboratories
Mosquito-borne viruses represent a large global health burden. With geographic expansion of competent vectors for chikungunya virus (CHIKV), dengue virus (DENV), and Zika virus (ZIKV) in Europe, it is anticipated that the number of autochthonous cases of these tropical viruses in Europe will increase. Therefore, regular assessment of diagnostic capabilities in Europe is important. Our aim was to evaluate the mosquito-borne virus molecular detection capability of expert European laboratories by conducting an external quality assessment in October 2023. Molecular panels included 12 plasma samples: one alphavirus (CHIKV), four orthoflaviviruses (ZIKV, yellow fever virus [YFV], DENV, and Japanese encephalitis virus [JEV]), and two negative control samples. Mosquito-borne virus detection was assessed among 36 laboratories in 24 European countries. Adequate capabilities were lacking for YFV and JEV. Many laboratories relied on a mix of laboratory-developed tests (some of which were pan-orthoflavivirus or pan-alphavirus in combination with sequencing) and commercial assays. 47.2% of laboratories characterized all external quality assessment (EQA) samples correctly. Correct result rates were 100% for CHIKV and ZIKV and >99% for DENV, but laboratories lacked capacity, specificity, and sensitivity for JEV and YFV. Three of the viruses in this panel emerged and transiently circulated in Europe: CHIKV, ZIKV, and DENV. Molecular detection was excellent for those viruses, but Aedes -borne viruses: chikungunya virus (CHIKV), dengue virus (DENV), Zika virus (ZIKV), and yellow fever virus (YFV). Japanese encephalitis virus, an orthoflavivirus that is spread by mosquito species belonging to the genus Culex , was included in the quality assessment as well. CHIKV, DENV, and ZIKV have proven potential for transient and limited circulation in Europe upon introduction of viremic travelers returning to Aedes albopictus -endemic regions. Results of this EQA were excellent for those viruses, but <50% is accurate for the remainder of the panel (YFV and Japanese encephalitis virus). Considering imported cases and the threat of climate change and competent vector expansion, progress toward rapid, accurate mosquito-borne virus diagnostics in Europe is recommended.
- 31 January 2025
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 63 (1) , e0091024
Open AccessExcellent capability for molecular detection of Aedes -borne dengue, Zika, and chikungunya viruses but with a need for increased capacity for yellow fever and Japanese encephalitis viruses: an external quality assessment in 36 European laboratories
Mosquito-borne viruses represent a large global health burden. With geographic expansion of competent vectors for chikungunya virus (CHIKV), dengue virus (DENV), and Zika virus (ZIKV) in Europe, it is anticipated that the number of autochthonous cases of these tropical viruses in Europe will increase. Therefore, regular assessment of diagnostic capabilities in Europe is important. Our aim was to evaluate the mosquito-borne virus molecular detection capability of expert European laboratories by conducting an external quality assessment in October 2023. Molecular panels included 12 plasma samples: one alphavirus (CHIKV), four orthoflaviviruses (ZIKV, yellow fever virus [YFV], DENV, and Japanese encephalitis virus [JEV]), and two negative control samples. Mosquito-borne virus detection was assessed among 36 laboratories in 24 European countries. Adequate capabilities were lacking for YFV and JEV. Many laboratories relied on a mix of laboratory-developed tests (some of which were pan-orthoflavivirus or pan-alphavirus in combination with sequencing) and commercial assays. 47.2% of laboratories characterized all external quality assessment (EQA) samples correctly. Correct result rates were 100% for CHIKV and ZIKV and >99% for DENV, but laboratories lacked capacity, specificity, and sensitivity for JEV and YFV. Three of the viruses in this panel emerged and transiently circulated in Europe: CHIKV, ZIKV, and DENV. Molecular detection was excellent for those viruses, but Aedes -borne viruses: chikungunya virus (CHIKV), dengue virus (DENV), Zika virus (ZIKV), and yellow fever virus (YFV). Japanese encephalitis virus, an orthoflavivirus that is spread by mosquito species belonging to the genus Culex , was included in the quality assessment as well. CHIKV, DENV, and ZIKV have proven potential for transient and limited circulation in Europe upon introduction of viremic travelers returning to Aedes albopictus -endemic regions. Results of this EQA were excellent for those viruses, but <50% is accurate for the remainder of the panel (YFV and Japanese encephalitis virus). Considering imported cases and the threat of climate change and competent vector expansion, progress toward rapid, accurate mosquito-borne virus diagnostics in Europe is recommended.
- Open Access
- 5 October 2023
- Published by European Centre for Disease Control and Prevention (ECDC) in Eurosurveillance
- Vol. 28 (40) , 2300054
External quality assessment of orthohantavirus and lymphocytic choriomeningitis virus molecular detection and serology in Europe, 2021
Background: Rodent-borne viruses such as orthohantaviruses and arenaviruses cause considerable disease burden with regional and temporal differences in incidence and clinical awareness. Therefore, it is important to regularly evaluate laboratory diagnostic capabilities, e.g. by external quality assessments (EQA). Aim: We wished to evaluate the performance and diagnostic capability of European expert laboratories to detect orthohantaviruses and lymphocytic choriomeningitis virus (LCMV) and human antibody response towards orthohantaviruses. Methods: We conducted an EQA in 2021; molecular panels consisted of 12 samples, including different orthohantaviruses (Seoul, Dobrava-Belgrade (DOBV), Puumala (PUUV) and Hantaan orthohantavirus), LCMV and negative controls. Serological panels consisted of six human serum samples reactive to PUUV, DOBV or negative to orthohantaviruses. The EQA was sent to 25 laboratories in 20 countries. Results: The accuracy of molecular detection of orthohantaviruses varied (50‒67%, average 62%) among 16 participating laboratories, while LCMV samples were successfully detected in all 11 participating laboratories (91-100%, average 96%). The accuracy of serological diagnosis of acute and past orthohantavirus infections was on average 95% among 20 participating laboratories and 82% in 19 laboratories, respectively. A variety of methods was used, with predominance of in-house assays for molecular tests, and commercial assays for serological ones. Conclusion: Serology, the most common tool to diagnose acute orthohantavirus infections, had a high accuracy in this EQA. The molecular detection of orthohantaviruses needs improvement while LCMV detection (performed in fewer laboratories) had 95% accuracy. Further EQAs are recommended to be performed periodically to monitor improvements and challenges in the diagnostics of rodent–borne diseases.
- 5 October 2023
- Published by European Centre for Disease Control and Prevention (ECDC) in Eurosurveillance
- Vol. 28 (40) , 2300054
Open AccessExternal quality assessment of orthohantavirus and lymphocytic choriomeningitis virus molecular detection and serology in Europe, 2021
Background: Rodent-borne viruses such as orthohantaviruses and arenaviruses cause considerable disease burden with regional and temporal differences in incidence and clinical awareness. Therefore, it is important to regularly evaluate laboratory diagnostic capabilities, e.g. by external quality assessments (EQA). Aim: We wished to evaluate the performance and diagnostic capability of European expert laboratories to detect orthohantaviruses and lymphocytic choriomeningitis virus (LCMV) and human antibody response towards orthohantaviruses. Methods: We conducted an EQA in 2021; molecular panels consisted of 12 samples, including different orthohantaviruses (Seoul, Dobrava-Belgrade (DOBV), Puumala (PUUV) and Hantaan orthohantavirus), LCMV and negative controls. Serological panels consisted of six human serum samples reactive to PUUV, DOBV or negative to orthohantaviruses. The EQA was sent to 25 laboratories in 20 countries. Results: The accuracy of molecular detection of orthohantaviruses varied (50‒67%, average 62%) among 16 participating laboratories, while LCMV samples were successfully detected in all 11 participating laboratories (91-100%, average 96%). The accuracy of serological diagnosis of acute and past orthohantavirus infections was on average 95% among 20 participating laboratories and 82% in 19 laboratories, respectively. A variety of methods was used, with predominance of in-house assays for molecular tests, and commercial assays for serological ones. Conclusion: Serology, the most common tool to diagnose acute orthohantavirus infections, had a high accuracy in this EQA. The molecular detection of orthohantaviruses needs improvement while LCMV detection (performed in fewer laboratories) had 95% accuracy. Further EQAs are recommended to be performed periodically to monitor improvements and challenges in the diagnostics of rodent–borne diseases.
- Open Access
- 29 September 2023
- Published by Elsevier in Journal of Virological Methods
- Vol. 322, 114825
Comparative study between virus neutralisation testing and other serological methods detecting anti-SARS-CoV-2 antibodies in Europe, 2021
- 29 September 2023
- Published by Elsevier in Journal of Virological Methods
- Vol. 322, 114825
Open AccessComparative study between virus neutralisation testing and other serological methods detecting anti-SARS-CoV-2 antibodies in Europe, 2021
- 21 December 2022
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 60 (12) , e0126122
Sensitivity of Detection and Variant Typing of SARS-CoV-2 in European Laboratories
The molecular detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is key for clinical management and surveillance. Funded by the European Centre for Disease Prevention and Control, we conducted an external quality assessment (EQA) on the molecular detection and variant typing of SARS-CoV-2 that included 59 European laboratories in 34 countries.
- 21 December 2022
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 60 (12) , e0126122
Sensitivity of Detection and Variant Typing of SARS-CoV-2 in European Laboratories
The molecular detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is key for clinical management and surveillance. Funded by the European Centre for Disease Prevention and Control, we conducted an external quality assessment (EQA) on the molecular detection and variant typing of SARS-CoV-2 that included 59 European laboratories in 34 countries.
- Open Access
- 22 October 2022
- Published by European Centre for Disease Control and Prevention (ECDC) in Eurosurveillance
- Vol. 27 (42) , 2101057
External quality assessment of SARS-CoV-2 serology in European expert laboratories, April 2021
Background: Countries worldwide are focusing to mitigate the ongoing SARS-CoV-2 pandemic by employing public health measures. Laboratories have a key role in the control of SARS-CoV-2 transmission. Serology for SARS-CoV-2 is of critical importance to support diagnosis, define the epidemiological framework and evaluate immune responses to natural infection and vaccine administration. Aim: The aim of this study was the assessment of the actual capability among laboratories involved in sero-epidemiological studies on COVID-19 in EU/EEA and EU enlargement countries to detect SARS-CoV-2 antibodies through an external quality assessment (EQA) based on proficiency testing. Methods: The EQA panels were composed of eight different, pooled human serum samples (all collected in 2020 before the vaccine roll-out), addressing sensitivity and specificity of detection. The panels and two EU human SARS-CoV-2 serological standards were sent to 56 laboratories in 30 countries. Results: The overall performance of laboratories within this EQA indicated a robust ability to establish past SARS-CoV-2 infections via detection of anti-SARS-CoV-2 antibodies, with 53 of 55 laboratories using at least one test that characterised all EQA samples correctly. IgM-specific test methods provided most incorrect sample characterisations (24/208), while test methods detecting total immunoglobulin (0/119) and neutralising antibodies (2/230) performed the best. The semiquantitative assays used by the EQA participants also showed a robust performance in relation to the standards. Conclusion: Our EQA showed a high capability across European reference laboratories for reliable diagnostics for SARS-CoV-2 antibody responses. Serological tests that provide robust and reliable detection of anti-SARS-CoV-2 antibodies are available.
- 22 October 2022
- Published by European Centre for Disease Control and Prevention (ECDC) in Eurosurveillance
- Vol. 27 (42) , 2101057
Open AccessExternal quality assessment of SARS-CoV-2 serology in European expert laboratories, April 2021
Background: Countries worldwide are focusing to mitigate the ongoing SARS-CoV-2 pandemic by employing public health measures. Laboratories have a key role in the control of SARS-CoV-2 transmission. Serology for SARS-CoV-2 is of critical importance to support diagnosis, define the epidemiological framework and evaluate immune responses to natural infection and vaccine administration. Aim: The aim of this study was the assessment of the actual capability among laboratories involved in sero-epidemiological studies on COVID-19 in EU/EEA and EU enlargement countries to detect SARS-CoV-2 antibodies through an external quality assessment (EQA) based on proficiency testing. Methods: The EQA panels were composed of eight different, pooled human serum samples (all collected in 2020 before the vaccine roll-out), addressing sensitivity and specificity of detection. The panels and two EU human SARS-CoV-2 serological standards were sent to 56 laboratories in 30 countries. Results: The overall performance of laboratories within this EQA indicated a robust ability to establish past SARS-CoV-2 infections via detection of anti-SARS-CoV-2 antibodies, with 53 of 55 laboratories using at least one test that characterised all EQA samples correctly. IgM-specific test methods provided most incorrect sample characterisations (24/208), while test methods detecting total immunoglobulin (0/119) and neutralising antibodies (2/230) performed the best. The semiquantitative assays used by the EQA participants also showed a robust performance in relation to the standards. Conclusion: Our EQA showed a high capability across European reference laboratories for reliable diagnostics for SARS-CoV-2 antibody responses. Serological tests that provide robust and reliable detection of anti-SARS-CoV-2 antibodies are available.
- Open Access
- 18 February 2021
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 59 (3)
Variable Sensitivity of SARS-CoV-2 Molecular Detection in European Expert Laboratories: External Quality Assessment, June and July 2020
During the ongoing coronavirus disease 2019 (COVID-19) outbreak, robust detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is a key element for clinical management and to interrupt transmission chains. We organized an external quality assessment (EQA) of molecular detection of SARS-CoV-2 for European expert laboratories. An EQA panel composed of 12 samples, containing either SARS-CoV-2 at different concentrations to evaluate sensitivity or other respiratory viruses to evaluate specificity of SARS-CoV-2 testing, was distributed to 68 laboratories in 35 countries.
- 18 February 2021
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 59 (3)
Open AccessVariable Sensitivity of SARS-CoV-2 Molecular Detection in European Expert Laboratories: External Quality Assessment, June and July 2020
During the ongoing coronavirus disease 2019 (COVID-19) outbreak, robust detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is a key element for clinical management and to interrupt transmission chains. We organized an external quality assessment (EQA) of molecular detection of SARS-CoV-2 for European expert laboratories. An EQA panel composed of 12 samples, containing either SARS-CoV-2 at different concentrations to evaluate sensitivity or other respiratory viruses to evaluate specificity of SARS-CoV-2 testing, was distributed to 68 laboratories in 35 countries.
- Open Access
- 1 January 2020
- Published by Taylor & Francis in Emerging Microbes & Infections
- Vol. 9 (1) , 1965-1973
Accurate serology for SARS-CoV-2 and common human coronaviruses using a multiplex approach
Serology is a crucial part of the public health response to the ongoing SARS-CoV-2 pandemic, but there are still many unknowns. Here, we describe the development, validation and clinical evaluation of a protein micro-array as a quantitative multiplex immunoassay that can identify S and N-directed SARS-CoV-2 IgG antibodies with high specificity and sensitivity and distinguish them from all currently circulating human coronaviruses. The method specificity was 100% for SARS-CoV-2 S1 and 96 % for N antigen based on extensive syndromic (n=230 cases) and population panel (n=94) testing that also confirmed the high prevalence of seasonal human coronaviruses. To assess the potential role of the protein micro-array for both SARS-CoV-2 patient diagnostics and population studies, we evaluated a large heterogeneous COVID-19 cohort (n=330) and found an overall sensitivity of 89% (≥ 21 days post onset symptoms (dps)), which ranged from 86% to 96% depending on severity of disease. For a subset of these patients longitudinal samples were provided up to 56 dps. We observed an absent or delayed, and lower SARS-CoV-2 antibody responses in mild cases. Overall, we present the development and extensive clinical validation of a multiplex human coronavirus serological assay that can be used for syndromic testing, to answer research questions regarding human coronavirus antibody responses, to support SARS-CoV-2 diagnostics where RT-PCR lacks in sensitivity and to evaluate epidemiological developments efficiently and with high-throughput.
- 1 January 2020
- Published by Taylor & Francis in Emerging Microbes & Infections
- Vol. 9 (1) , 1965-1973
Open AccessAccurate serology for SARS-CoV-2 and common human coronaviruses using a multiplex approach
Serology is a crucial part of the public health response to the ongoing SARS-CoV-2 pandemic, but there are still many unknowns. Here, we describe the development, validation and clinical evaluation of a protein micro-array as a quantitative multiplex immunoassay that can identify S and N-directed SARS-CoV-2 IgG antibodies with high specificity and sensitivity and distinguish them from all currently circulating human coronaviruses. The method specificity was 100% for SARS-CoV-2 S1 and 96 % for N antigen based on extensive syndromic (n=230 cases) and population panel (n=94) testing that also confirmed the high prevalence of seasonal human coronaviruses. To assess the potential role of the protein micro-array for both SARS-CoV-2 patient diagnostics and population studies, we evaluated a large heterogeneous COVID-19 cohort (n=330) and found an overall sensitivity of 89% (≥ 21 days post onset symptoms (dps)), which ranged from 86% to 96% depending on severity of disease. For a subset of these patients longitudinal samples were provided up to 56 dps. We observed an absent or delayed, and lower SARS-CoV-2 antibody responses in mild cases. Overall, we present the development and extensive clinical validation of a multiplex human coronavirus serological assay that can be used for syndromic testing, to answer research questions regarding human coronavirus antibody responses, to support SARS-CoV-2 diagnostics where RT-PCR lacks in sensitivity and to evaluate epidemiological developments efficiently and with high-throughput.
- Open Access
- 10 May 2018
- Published by European Centre for Disease Control and Prevention (ECDC) in Eurosurveillance
- Vol. 23 (19) , 17-00404-27
Status, quality and specific needs of Ebola virus diagnostic capacity and capability in laboratories of the two European preparedness laboratory networks EMERGE and EVD-LabNet
From December 2013 to March 2016, West Africa experienced the largest Ebola virus (EBOV) outbreak to date, leading to a European-wide activation of laboratory preparedness and response. At the end of the outbreak, laboratories associated with the two European preparedness networks of expert laboratories EMERGE JA and EVD-LabNet were invited to participate in an assessment of the response of European laboratories to the EBOV outbreak, to identify learning points and training needs to strengthen future outbreak responses. Response aspects assessed included diagnostics, biorisk management and quality assurance. The overall coverage of EBOV diagnostics in the European Union/European Economic Area (EU/EEA) was found to be adequate although some points for quality improvement were identified. These included the need for relevant International Organization for Standardization (ISO) accreditation, the provision of EBOV external quality assessments (EQA) in periods where there is no emergency, facilitating access to controls and knowledge, biorisk management without compromising biosafety and a rapid public health response, and the need for both sustained and contingency funding for preparedness and response activities.
- 10 May 2018
- Published by European Centre for Disease Control and Prevention (ECDC) in Eurosurveillance
- Vol. 23 (19) , 17-00404-27
Open AccessStatus, quality and specific needs of Ebola virus diagnostic capacity and capability in laboratories of the two European preparedness laboratory networks EMERGE and EVD-LabNet
From December 2013 to March 2016, West Africa experienced the largest Ebola virus (EBOV) outbreak to date, leading to a European-wide activation of laboratory preparedness and response. At the end of the outbreak, laboratories associated with the two European preparedness networks of expert laboratories EMERGE JA and EVD-LabNet were invited to participate in an assessment of the response of European laboratories to the EBOV outbreak, to identify learning points and training needs to strengthen future outbreak responses. Response aspects assessed included diagnostics, biorisk management and quality assurance. The overall coverage of EBOV diagnostics in the European Union/European Economic Area (EU/EEA) was found to be adequate although some points for quality improvement were identified. These included the need for relevant International Organization for Standardization (ISO) accreditation, the provision of EBOV external quality assessments (EQA) in periods where there is no emergency, facilitating access to controls and knowledge, biorisk management without compromising biosafety and a rapid public health response, and the need for both sustained and contingency funding for preparedness and response activities.