Brian G. Clement
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Brian G. Clement has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Adriana Blachowicz
Biotechnology and Planetary Protection Group, Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California, USA
2 shared publications - Ceth W. Parker
Jet Propulsion Laboratory-NASA
2 shared publications - Ioannis G. Mikellides
Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109, USA
2 shared publications J. Mennella
2 shared publications- Jason Michael Wood
Biotechnology and Planetary Protection Group, Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA, United States
2 shared publications - Kasthuri Venkateswaran
California Institute of Technology
2 shared publications
Latest Publications
- 14 July 2026
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Planets
- Vol. 131 (7)
The Transmittance of Micron‐Sized Abiological Mars Simulant Particles to Ultraviolet Radiation
In this study microspectrophotometry and first‐principles analyses were employed to investigate the spectral transmittance () of small particles to ultraviolet radiation in the wavelength range of 260 420 nm. Twenty‐four particles were selected from Mojave Mars Simulant (MMS) dust to emulate the properties and size of solid aerosols in the Martian atmosphere. The mean height () of the particles ranged 2.3–14 μm. Only 8.3% of the particles exhibited 0.1 and none had 0.035. The remaining (91.7%) exhibited higher values, some of which reached 0.7. Significant variability in the of the particles was also observed. Using Mie's scattering theory, this variability was attributed, in part, to the sensitivity of the radiation scattering and absorption on the diffraction parameter and, more strongly, on the absorptive spectral index of refraction . The diffraction parameter in our study was in the range 17.2–169.2. Integrating sphere microscopy was also used to measure the transmittance of long thin sheets, formed by compressing particles from the same MMS into a UV‐transparent Room Temperature Vulcanizing layer on UVFS substates. The mean height of these sheets was ∼20 μm. More consistent patterns were obtained in this configuration. In the range 240 500 nm, both measurements and models yielded 0.12 0.33. The transmittance model was found to be in excellent agreement with the measurement for the mean index of refraction . The combination of different experiments and theory provides strong evidence that micron‐scale solid aerosols in the Martian atmosphere can be quite transparent to UV radiation.
- 14 July 2026
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Planets
- Vol. 131 (7)
The Transmittance of Micron‐Sized Abiological Mars Simulant Particles to Ultraviolet Radiation
In this study microspectrophotometry and first‐principles analyses were employed to investigate the spectral transmittance () of small particles to ultraviolet radiation in the wavelength range of 260 420 nm. Twenty‐four particles were selected from Mojave Mars Simulant (MMS) dust to emulate the properties and size of solid aerosols in the Martian atmosphere. The mean height () of the particles ranged 2.3–14 μm. Only 8.3% of the particles exhibited 0.1 and none had 0.035. The remaining (91.7%) exhibited higher values, some of which reached 0.7. Significant variability in the of the particles was also observed. Using Mie's scattering theory, this variability was attributed, in part, to the sensitivity of the radiation scattering and absorption on the diffraction parameter and, more strongly, on the absorptive spectral index of refraction . The diffraction parameter in our study was in the range 17.2–169.2. Integrating sphere microscopy was also used to measure the transmittance of long thin sheets, formed by compressing particles from the same MMS into a UV‐transparent Room Temperature Vulcanizing layer on UVFS substates. The mean height of these sheets was ∼20 μm. More consistent patterns were obtained in this configuration. In the range 240 500 nm, both measurements and models yielded 0.12 0.33. The transmittance model was found to be in excellent agreement with the measurement for the mean index of refraction . The combination of different experiments and theory provides strong evidence that micron‐scale solid aerosols in the Martian atmosphere can be quite transparent to UV radiation.
- Open Access
- 27 October 2020
- Published by American Society for Microbiology in mSystems
- Vol. 5 (5)
End-to-End Protocol for the Detection of SARS-CoV-2 from Built Environments
The ongoing severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) (the virus responsible for coronavirus disease 2019 [COVID-19]) pandemic has led to a global slowdown with far-reaching financial and social impacts. The SARS-CoV-2 respiratory virus is primarily transmitted from person to person through inhalation of infected droplets or aerosols. However, some studies have shown that virions can remain infectious on surfaces for days and can lead to human infection from contact with infected surfaces. Thus, a comprehensive study was conducted to determine the efficiency of protocols to recover SARS-CoV-2 from surfaces in built environments. This end-to-end study showed that the effective combination for monitoring SARS-CoV-2 on surfaces required a minimum of 1,000 viral particles per 25 cm 2 to successfully detect virus from surfaces. This comprehensive study can provide valuable information regarding surface monitoring of various materials as well as the capacity to retain viral RNA and allow for effective disinfection.
- 27 October 2020
- Published by American Society for Microbiology in mSystems
- Vol. 5 (5)
Open AccessEnd-to-End Protocol for the Detection of SARS-CoV-2 from Built Environments
The ongoing severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) (the virus responsible for coronavirus disease 2019 [COVID-19]) pandemic has led to a global slowdown with far-reaching financial and social impacts. The SARS-CoV-2 respiratory virus is primarily transmitted from person to person through inhalation of infected droplets or aerosols. However, some studies have shown that virions can remain infectious on surfaces for days and can lead to human infection from contact with infected surfaces. Thus, a comprehensive study was conducted to determine the efficiency of protocols to recover SARS-CoV-2 from surfaces in built environments. This end-to-end study showed that the effective combination for monitoring SARS-CoV-2 on surfaces required a minimum of 1,000 viral particles per 25 cm 2 to successfully detect virus from surfaces. This comprehensive study can provide valuable information regarding surface monitoring of various materials as well as the capacity to retain viral RNA and allow for effective disinfection.
- Open Access
End-to-End Protocol for the Detection of SARS-CoV-2 from Built Environments
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the virus that causes coronavirus disease 2019, is a respiratory virus primarily transmitted from person to person through inhalation of droplets or aerosols, laden with viral particles. However, as some studies have shown, virions can remain infectious for up to 72 hours on surfaces, which can lead to transmission through contact. For this reason, a comprehensive study was conducted to determine the efficiency of protocols to recover SARS-CoV-2 from surfaces in built environments. This end-to-end (E2E) study showed that the effective combination of monitoring SARS-CoV-2 on surfaces include using an Isohelix swab as a collection tool, DNA/RNA Shield as a preservative, an automated system for RNA extraction, and reverse transcriptase quantitative polymerase chain reaction (RT-qPCR) as the detection assay. Using this E2E approach, this study showed that, in some cases, SARS-CoV-2 viral standards were still recovered from surfaces as detected by RT-qPCR for as long as eight days even after bleach treatment. Additionally, debris associated with specific built environment surfaces appeared to negatively impact the recovery of RNA, with Amerstat inhibition as high as 90% when challenged with an inactivated viral control. Overall, it was determined that this E2E protocol required a minimum of 1,000 viral particles per 25 cm 2 to successfully detect virus from test surfaces. When this method was employed to evaluate 368 samples collected from various built environmental surfaces, all samples tested negative, indicating that the surfaces were either void of virus or below the detection limit of the assay. Importance: The ongoing severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) (the virus responsible for coronavirus disease 2019; COVID-19) pandemic has led to a global slow down with far reaching financial and social impacts. The SARS-CoV-2 respiratory virus is primarily transmitted from person to person through inhalation of infected droplets or aerosols. However, some studies have shown virions can remain infectious on surfaces for days, and can lead to human infection from contact with infected surfaces. Thus, a comprehensive study was conducted to determine the efficiency of protocols to recover SARS-CoV-2 from surfaces in built environments. This end-to-end study showed that the effective combination of monitoring SARS-CoV-2 on surfaces required a minimum of 1,000 viral particles per 25 cm 2 to successfully detect virus from surfaces. This comprehensive study can provide valuable information regarding surface monitoring of various materials as well as the capacity to retain viral RNA and allow for effective disinfection.
Open AccessEnd-to-End Protocol for the Detection of SARS-CoV-2 from Built Environments
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the virus that causes coronavirus disease 2019, is a respiratory virus primarily transmitted from person to person through inhalation of droplets or aerosols, laden with viral particles. However, as some studies have shown, virions can remain infectious for up to 72 hours on surfaces, which can lead to transmission through contact. For this reason, a comprehensive study was conducted to determine the efficiency of protocols to recover SARS-CoV-2 from surfaces in built environments. This end-to-end (E2E) study showed that the effective combination of monitoring SARS-CoV-2 on surfaces include using an Isohelix swab as a collection tool, DNA/RNA Shield as a preservative, an automated system for RNA extraction, and reverse transcriptase quantitative polymerase chain reaction (RT-qPCR) as the detection assay. Using this E2E approach, this study showed that, in some cases, SARS-CoV-2 viral standards were still recovered from surfaces as detected by RT-qPCR for as long as eight days even after bleach treatment. Additionally, debris associated with specific built environment surfaces appeared to negatively impact the recovery of RNA, with Amerstat inhibition as high as 90% when challenged with an inactivated viral control. Overall, it was determined that this E2E protocol required a minimum of 1,000 viral particles per 25 cm 2 to successfully detect virus from test surfaces. When this method was employed to evaluate 368 samples collected from various built environmental surfaces, all samples tested negative, indicating that the surfaces were either void of virus or below the detection limit of the assay. Importance: The ongoing severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) (the virus responsible for coronavirus disease 2019; COVID-19) pandemic has led to a global slow down with far reaching financial and social impacts. The SARS-CoV-2 respiratory virus is primarily transmitted from person to person through inhalation of infected droplets or aerosols. However, some studies have shown virions can remain infectious on surfaces for days, and can lead to human infection from contact with infected surfaces. Thus, a comprehensive study was conducted to determine the efficiency of protocols to recover SARS-CoV-2 from surfaces in built environments. This end-to-end study showed that the effective combination of monitoring SARS-CoV-2 on surfaces required a minimum of 1,000 viral particles per 25 cm 2 to successfully detect virus from surfaces. This comprehensive study can provide valuable information regarding surface monitoring of various materials as well as the capacity to retain viral RNA and allow for effective disinfection.
- 1 April 2009
- Published by Elsevier in Geochimica et Cosmochimica Acta
- Vol. 73 (7) , 1878-1889
Rapid, oxygen-dependent microbial Mn(II) oxidation kinetics at sub-micromolar oxygen concentrations in the Black Sea suboxic zone
- 1 April 2009
- Published by Elsevier in Geochimica et Cosmochimica Acta
- Vol. 73 (7) , 1878-1889
Rapid, oxygen-dependent microbial Mn(II) oxidation kinetics at sub-micromolar oxygen concentrations in the Black Sea suboxic zone