Jianian Zheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jianian Zheng has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Huiyi Cao
Department of Electrical, Computer, and Systems Engineering, Case Western Reserve University, Cleveland, OH, USA
2 shared publications - Ming-Chun Huang
Duke Kunshan University
2 shared publications - Diliang Chen
Department of Electrical and Computer Engineering, University of New Hampshire, Durham, NH, USA
1 shared publication Jia Chen
Department of Electrical Engineering and Computer Science, Case Western Reserve University, Cleveland, United States of America
1 shared publication- Kuo-Chung Chu
Department of Information Management, National Taipei University of Nursing and Health Sciences, Taipei, Taiwan
1 shared publication Ming-Chun Huang
Department of Electrical Engineering and Computer Science, Case Western Reserve University, Cleveland, United States of America
1 shared publication
Latest Publications
- 28 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 9 (16) , 15077-15088
mHealth Technologies Toward Active Health Information Collection and Tracking in Daily Life: A Dynamic Gait Monitoring Example
Monitoring the changes in gait patterns is important to individuals’ health. Gait analysis should be taken as early as possible to prevent gait impairments and improve gait quality. Accurate stride-length estimation and gait rehabilitation activity recognition are fundamental components in gait monitoring, gait analysis, and long-term gait care. This article proposes a novel multimodality deep learning architecture to investigate the applications of stride length (SL) estimation and rehabilitation activity recognition. In order to verify this architecture, we have conducted the data collection and data labeling with our customized wearable sensing system. The sensing system can provide sensor readings from 96 sensors-based pressure array and 3-channels accelerometer and gyroscope. Many experiments with multiple perspective analysis are implemented to evaluate the models’ precision, robustness, and reliability. The multimodality deep learning architecture can map multiple sensor readings to the resulting SL with a mean absolute error of 3.89 cm and accurately detect the gait activity with an accuracy of 97.08%. It correlates the step length estimation and gait activity recognition to fulfill comprehensive long-term gait information statistic. The proposed applications’ implementation enriched our previous gait study and brought insights for clinically relevant wearable gait monitoring and gait analysis.
- 28 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 9 (16) , 15077-15088
mHealth Technologies Toward Active Health Information Collection and Tracking in Daily Life: A Dynamic Gait Monitoring Example
Monitoring the changes in gait patterns is important to individuals’ health. Gait analysis should be taken as early as possible to prevent gait impairments and improve gait quality. Accurate stride-length estimation and gait rehabilitation activity recognition are fundamental components in gait monitoring, gait analysis, and long-term gait care. This article proposes a novel multimodality deep learning architecture to investigate the applications of stride length (SL) estimation and rehabilitation activity recognition. In order to verify this architecture, we have conducted the data collection and data labeling with our customized wearable sensing system. The sensing system can provide sensor readings from 96 sensors-based pressure array and 3-channels accelerometer and gyroscope. Many experiments with multiple perspective analysis are implemented to evaluate the models’ precision, robustness, and reliability. The multimodality deep learning architecture can map multiple sensor readings to the resulting SL with a mean absolute error of 3.89 cm and accurately detect the gait activity with an accuracy of 97.08%. It correlates the step length estimation and gait activity recognition to fulfill comprehensive long-term gait information statistic. The proposed applications’ implementation enriched our previous gait study and brought insights for clinically relevant wearable gait monitoring and gait analysis.
- 9 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 20 (16) , 9274-9282
Designing Deep Reinforcement Learning Systems for Musculoskeletal Modeling and Locomotion Analysis Using Wearable Sensor Feedback
In this paper, a system for lower-limb amputees to collect and analyze their locomotion activities is developed. Wearable Gait Lab (WGL) system is a pair of smart insoles that can collect plantar pressure data and foot motion data of subjects. A reinforcement learning model is trained to imitate the walking pattern of the lower-limb amputee on a musculoskeletal model by introducing realistic velocity data into the training process. The plantar pressure data collected from our Wearable Gait Lab were used to recognize the locomotion modes of the amputees. Experiments showed that the outcome of the musculoskeletal model can be a reference for analyzing muscle activities of the amputee. The system also shows the promising and stable performance of recognizing locomotion modes in amputees’ daily life. The accuracy of locomotion mode recognition reaches 98.02Monitoring muscle activities and locomotion modes of lowerlimb amputees can help them prevent secondary impairments in rehabilitation.
- 9 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 20 (16) , 9274-9282
Designing Deep Reinforcement Learning Systems for Musculoskeletal Modeling and Locomotion Analysis Using Wearable Sensor Feedback
In this paper, a system for lower-limb amputees to collect and analyze their locomotion activities is developed. Wearable Gait Lab (WGL) system is a pair of smart insoles that can collect plantar pressure data and foot motion data of subjects. A reinforcement learning model is trained to imitate the walking pattern of the lower-limb amputee on a musculoskeletal model by introducing realistic velocity data into the training process. The plantar pressure data collected from our Wearable Gait Lab were used to recognize the locomotion modes of the amputees. Experiments showed that the outcome of the musculoskeletal model can be a reference for analyzing muscle activities of the amputee. The system also shows the promising and stable performance of recognizing locomotion modes in amputees’ daily life. The accuracy of locomotion mode recognition reaches 98.02Monitoring muscle activities and locomotion modes of lowerlimb amputees can help them prevent secondary impairments in rehabilitation.
- 1 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Explore Correlation Between Body Balance and Perception using mHealth Technology
Body balance and perception have been shown to be linked in a number of studies, ranging from plasma membrane calcium ATPase isoform PMCA2 deficiency causing both balance and hearing problems in mice to MS (multiple sclerosis) patients' loss of foot sole sensitivity correlating with compromised balance. This project involved developing a system that tests balance as well as hearing using Augmented Reality (AR) and mobile health (mHealth) technology. Four balance tests are included in the AR application; three are from Smart Balance Master (Limits of Stability, Rhythmic Weight Shift, Sit to Stand), and the fourth is a modified Single Leg Stand with 32 sensory conditions. Hearing is tested within the same application through beeps played sequentially at frequencies of 500 Hertz, 1000 Hertz, 2000 Hertz, 4000 Hertz, and 8000 Hertz for each ear. The first volume level they are played at is less than 10 Hertz and this can be sequentially increases in increments of 10 decibels up to 100 decibels until the player can hear the beep; this volume level is recorded. The application is meant to be used with Wearable Gait Lab (WGL), an underfoot plantar pressure unit. The user wears Microsoft HoloLens (which runs the AR application) and WGL (which records balance data); experimental data is analyzed for a correlation between perception and balance in ten young adults as a proof of model.
- 1 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Explore Correlation Between Body Balance and Perception using mHealth Technology
Body balance and perception have been shown to be linked in a number of studies, ranging from plasma membrane calcium ATPase isoform PMCA2 deficiency causing both balance and hearing problems in mice to MS (multiple sclerosis) patients' loss of foot sole sensitivity correlating with compromised balance. This project involved developing a system that tests balance as well as hearing using Augmented Reality (AR) and mobile health (mHealth) technology. Four balance tests are included in the AR application; three are from Smart Balance Master (Limits of Stability, Rhythmic Weight Shift, Sit to Stand), and the fourth is a modified Single Leg Stand with 32 sensory conditions. Hearing is tested within the same application through beeps played sequentially at frequencies of 500 Hertz, 1000 Hertz, 2000 Hertz, 4000 Hertz, and 8000 Hertz for each ear. The first volume level they are played at is less than 10 Hertz and this can be sequentially increases in increments of 10 decibels up to 100 decibels until the player can hear the beep; this volume level is recorded. The application is meant to be used with Wearable Gait Lab (WGL), an underfoot plantar pressure unit. The user wears Microsoft HoloLens (which runs the AR application) and WGL (which records balance data); experimental data is analyzed for a correlation between perception and balance in ten young adults as a proof of model.