ZLZahra Lasemiimeni

Zahra Lasemiimeni

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Zahra Lasemiimeni has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Point-of-Care Breast Imaging for Monitoring Neoadjuvant Treatment: Case Studies With Transmission-Based Microwave Imaging

    by Pedram Mojabi, Roger Y. Tsang, Bobbie-Jo Docktor, Danielle Deutscher, Anita Garland, Zahra Lasemiimeni, Jeremie Bourqui, Elise Fear

    Objective: This study aims to track changes in tissues due to neoadjuvant chemotherapy with a transmission-based microwave imaging system that scans the entire breast and is fast, comfortable and suited to point-of-care implementation. Methods: Microwave scans are collected with patients undergoing chemotherapy treatment. Specifically, both breasts are scanned prior to each cycle of chemotherapy. The microwave scanner consists of planar transmit and receive arrays that are placed in contact with the breast. Signals with frequency content from 0.1 to 8 GHz are transmitted through the tissue, and the travel time of these signals is used to estimate the microwave frequency properties (permittivity). Property estimates at each sensor pair are mapped to the imaging plane. Results: Case studies are presented for 6 patients. Comparison of the scans of left and right breasts suggests increased properties related to the presence of the tumor at the initial scan. Consistent properties are observed for the contralateral breast at different time points, while changes in the breast with the tumor are noted. In addition, differences between the breasts are more clearly depicted in dense breasts. Conclusions: This study demonstrates the potential for a transmission-based microwave scanner to provide feedback on treatment progress. Significance: Point-of-care microwave imaging has the potential to offer regular, quantitative feedback on treatment progress as an alternative to palpation.

  • Novel Chirp Pulse Transmission Imaging Approach for Average Permittivity Estimation and Mapping

    by Zahra Lasemiimeni, Elise C. Fear

    Chirp pulse microwave computed tomography (CP-MCT) has been proposed as a robust mathematical technique for reconstructing images of the interior of objects. However, its application has been primarily limited to reconstructing attenuation images in simple scenarios. In this paper, chirp pulse transmission imaging (CPTI) is introduced to leverage signal isolation capabilities of microwave time delay spectroscopy (MTDS) and identify direct-path signals for accurate permittivity estimation. The approach has been validated through various simulation scenarios, including homogeneous slabs with varying permittivities, a slab with an inclusion, and homogeneous cylinders. The proposed method demonstrates high accuracy in determining the time of arrival (TOA), resulting in reliable average permittivity measurements and improved accuracy when compared with other methods such as peak detection. Subsequently, the backprojected images produced by the method provide a clear and accurate representation of the object’s permittivity.


  • Microwave Imaging for Breast Cancer Detection: Performance Assessment of a Next-Generation Transmission System

    by Pedram Mojabi, Jeremie Bourqui, Zahra Lasemiimeni, Baldeep Grewal, Elise Fear

    Microwave imaging has been proposed for breast cancer detection and treatment monitoring. Prototype systems based on tomography and radar-based techniques have been tested on human subjects with promising results. Previously, we developed a system that estimated average permittivity in regions of the breast using signals transmitted through the tissues. Encouraging results with volunteers and patients motivated development of a system capable of creating more detailed images of the entire breast. Objective: In this paper, we aim to assess the performance of this next generation microwave imaging system and demonstrate scans of human subjects that relate to clinical information. Methods: With a novel imaging system, scans of homogeneous phantoms and phantoms with inclusions of various sizes are collected. The accuracy, detection and localization are assessed. A pilot study is carried out with a small group of volunteers with previous mammograms. Results: Images of flexible phantoms have average error of less than 10 % in the reconstructed average permittivity. Detection of inclusions of 1 cm diameter and greater is demonstrated. The feasibility of scanning human subjects is also demonstrated by providing microwave images of several healthy volunteers with previous mammograms. Significance: A novel high-resolution microwave transmission imaging system, in conjunction with a fast quantitative reconstruction algorithm capable of detecting 1 cm diameter inclusions, is designed for breast imaging applications. It can image various breast sizes without the need for matching fluid. Conclusion: Overall, the results indicate that this imaging system is well suited for further exploration of microwave imaging with human subjects.


  • Reproducibility of Microwave Breast Imaging: Analysis of Regular Scans of a Group of Volunteers

    by Zefang Wang, Pedram Mojabi, Sarah Price, Zahra Lasemiimeni, Brendon Besler, Jeremie Bourqui, Danielle Deutscher, Hua Shen, Bobbie Docktor, Roger Y. Tsang, et al.

    Microwave imaging has been proposed for breast cancer detection and treatment monitoring. The introduction of new approaches or next-generation prototype systems requires characterization of expected variability when scanning participants over clinically relevant timeframes.Objective: The objective of this study is to quantify the reliability and variability in scans of a group of 35 volunteers collected at multiple time points with a next-generation microwave imaging system. Methods: Multiple scans of the same volunteer are collected both during one visit and over multiple visits. Test-retest reliability and variability in measurements are investigated for the average permittivity of breast tissues. Results: The average permittivity for each volunteer exhibited similarity during and between sessions, with some variation noted for smaller breast sizes. The average properties of right and left breasts were also similar. Reliability was demonstrated with the intra-class correlation coefficient (ICC) values statistically greater than 0.9 both within and between sessions. Variability of the measurement was typically less than one unit and coefficient of variation less than 5% (within sessions) or 6% (between sessions).Conclusion: The microwave imaging system exhibits excellent reliability when scanning volunteers multiple times during one session and between sessions. This study represents the largest group of participants scanned at multiple time points reported to date. Significance: The excellent reliability demonstrated in this study suggests that microwave breast imaging has strong potential for capturing changes over time, such as treatment or therapy related effects, along with detecting changes in breast tissues.


  • Open Access

    Scoping review of precision technologies for cattle monitoring

    by Brendon C. Besler, Pedram Mojabi, Zahra Lasemiimeni, James E. Murphy, Zefang Wang, Ryan Baker, Jennifer M. Pearson, Elise C. Fear


  • Open Access

    Dual-Functional Ultrawideband Antenna With High Fidelity Factor for Body Area Networks and Microwave Imaging Systems

    by Zahra Lasemiimeni, Zahra Atlasbaf, Nima Karbaschi

    Microwave Imaging (MI) and Body Area Networks (BANs) technologies are widely used in healthcare systems. A dual-functional compact ultrawideband (UWB) antenna with a high on-body and off-body fidelity factor is presented in this paper. The antenna’s design approach is based on analyzing the return loss, the antenna’s gain, the phase of S 21 , and the group delay over the UWB frequency band, in each designing step, to achieve the highest level of fidelity factor in both E- and H-plane. The final design (Ant. 3) consists of a circular ring with six intersecting rings in the radiating element and an elliptic ground plane with an overall size of $16\times 20\,\,mm^{2}$ . Simulated and experimental evaluations both in free space and on-body prove the excellent operation of Ant. 3 within the FCC UWB bandwidth of 3.1 to 10.6 GHz in terms of return loss and fidelity factor (greater than 0.9 at all angles). For body area communication, the final design presents the fidelity factor greater than 0.93 near the human arm. Also, for breast cancer detection applicability, a 12-element array of Ant. 3 is located around a conical breast model. The results show the antenna’s promising performance in detecting 6-mm average diameter malignant tumor and 3-mm average diameter benign tumor.


  • Impact of Fidelity Factor on Breast Cancer Detection

    by Zahra Lasemiimeni, Zahra Atlasbaf

    Two compact ULTRAWIDEBAND (UWB) antennas with different values of fidelity factors are introduced in this paper to study the impact of the fidelity factor on the tumor detection of microwave imaging (MI) systems. The design procedures are based on achieving the largest possible bandwidth. Antenna 1 (Ant.1) and Antenna 2 (Ant. 2) have an overall size of $20 \times 28 mm^2$ and $16 \times 22 mm^2$ , respectively. Two arrays of the proposed antenna are utilized for breast cancer detection. Two 12-element arrays of the antennas are located around a breast tissue model in two scenarios. The results show the promising performance of Ant. 2, which has a higher fidelity factor in detecting a 4-mm tumor. The investigation was also carried out on a clinical tumor model, and Ant. 2 successfully detected it.