NINathaniel M. Ivanick

Nathaniel M. Ivanick

*This is an algorithmically generated author record based on publicly available information.

Nathaniel M. Ivanick has a total of 54 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Life-threatening tracheal leiomyoma presenting as acute respiratory failure masquerading as refractory asthma: A case report

    by Nathaniel M. Ivanick, Marina Filice, Michelle Sabia, Jessica Baek, Khubaib Mohammad Murtafa

  • Underreporting of Malignant Central Airway Obstruction

    by Nathaniel M. Ivanick, William Mahoney, Ishaan Gupta, Jamal Suboh, Tyler Pauly, Maryam Ahmed, Basarat Baig, Saad bin Jamil, Rajesh Kunadharaju, Sajeer Bhura, et al.

    Background: Malignant central airway obstruction (MCAO) is a common complication of lung cancer. Cross-sectional imaging is the best method of screening for this complication, but prior data indicate that such obstruction is frequently underreported on radiology reports. Methods: A cohort with known MCAO was selected and radiology reports were reviewed. Data on scan indication, airway obstruction severity intravenous contrast use were tracked, as were relevant dates. Data on diagnostic and therapeutic bronchoscopy were also tracked. Results: The frequency of missed MCAO across mild and severe obstruction was 54%. Mild obstruction was missed more frequently than severe obstruction 77% versus 46%. Symptom-based versus scheduled-based scans had no significant difference in identification rates (53% vs. 58%). Contrast enhancement versus noncontrast did not significantly impact identification rates (44% vs. 56%). Airway obstruction identification was associated with a significantly faster time to first clinic appointment (8 vs. 11 d), but not with a significant difference in patient survival. Conclusion: Radiology underreporting of MCAO occurs at rates higher than previously demonstrated, with better detection of severe over mild obstruction. Other clinical parameters do not appear to significantly impact rates of identification. Identification is significantly associated with shorter times to first visit evaluation.

  • Robotic-Assisted Bronchoscopy

    by Chan Yeu Pu, Nathaniel M. Ivanick

  • Open Access

    A retrospective comparison of silicone and hybrid metal tracheobronchial Y stents

    by Nathaniel Ivanick, William Mahoney, Akhil Goud Pachimatla, Sai Yendamuri, Yaron Gesthalter

    Background: Malignant central airway obstruction (MCAO) is a common and deadly complication of both lung cancer and non-lung cancers that have metastasized to the lungs. Tumors affecting the main carina offer a particular challenge and often require a specialized tracheobronchial Y stent placement. Historically, silicone Y stents have been the only Y stents available, however, newer hybrid metal Y stents have emerged as potential treatment options. We sought to compare various technical factors of silicone and hybrid Y stent placement. Methods: Patients diagnosed with primary or secondary lung cancer who underwent bronchoscopic stenting for MCAO at Roswell Park Comprehensive Cancer Center between 2014 and 2024 were included in this study. Data were collected on demographics, disease characteristics, bronchoscopy procedures, associated complications, and subsequent interventions. Procedure duration, complication rates, and the need for future interventions were compared between silicone and hybrid Y stents using the Mann-Whitney U test, Fisher’s exact test, and the Chi-squared test. Results: After a thorough review, 34 patients were included in the study, with 14 receiving hybrid metal stents and 20 receiving silicone stents. The procedure time for hybrid stents was significantly shorter than that for silicone stents (56 vs. 91 minutes, P=0.001). Additionally, patients with hybrid metal stents required fewer repeat bronchoscopies (mean: 0.21 vs. 1.15, P=0.03). There were no significant differences between the two groups in terms of early or late complications, 30-day mortality rates, or the degree of obstruction improvement. Conclusions: Hybrid metal Y stents may have an advantage in speed of placement and the need for repeat bronchoscopies while having a similar degree of improvement in obstruction and complication rates.

  • Open Access

    Epidemiology and Survival of Malignant Central Airway Obstruction in Lung Cancer Identified on Cross-Sectional Imaging

    by Nathaniel M. Ivanick, Rajesh Kunadharaju, Sajeer Bhura, Hiwot Mengiste, Musa Saeed, Arjun Saradna, Harshwant Grover, Sukumar Kalvapudi, Sai Yendamuri, Han Yu, et al.

    Background: The prevalence of malignant central airway obstruction at diagnosis and its 5-year incidence are largely unknown, as are basic epidemiological data pertaining to this serious condition. To address these data limitations, we retrospectively collected data from the cohort of patients diagnosed with lung cancer at our institution in 2015 and followed cohort patients 5 years forward, until 2020. Methods: We reviewed index PET/CT or CT scans at the time of lung cancer diagnosis to identify the presence, subtype, and severity of malignant central airway obstruction as well as progression/development over the next 5 years. Results: The prevalence of malignant central airway obstruction affecting the airway lumen by 25% or greater was 17%, and its 5-year incidence of development was 8.2%. Notable associations from the multivariate analysis included a younger age and a stepwise increase in obstruction with increasing stage of disease. Squamous cell carcinoma and small-cell lung cancer were the 2 histologic subtypes with the strongest association with obstruction. The presence of malignant central airway obstruction either at time of diagnosis or on follow-up imaging was associated with significantly shortened survival (multivariate Cox proportional HR for MCAO=1.702, P<0.001). Conclusion: This study provides the first systematic characterization of fundamental epidemiological data on malignant central airway obstructions at a tertiary cancer center in the United States. This data is important to inform research directions and funding efforts of this serious complication. It also serves as a baseline value against which to compare for future studies.


  • Open Access

    Correlation of Bronchoscopy and CT in Characterizing Malignant Central Airway Obstruction

    by Sukumar Kalvapudi, Hafiz M. Zubair, Rajesh Kunadharaju, Sajeer Bhura, Hiwot Mengiste, Musa Saeed, Arjun Saradna, Harshwant Grover, Gal Shafirstein, Sai Yendamuri, et al.

    Background: Malignant Central Airway Obstruction (MCAO) presents a significant challenge in lung cancer management, with notable morbidity and mortality implications. While bronchoscopy is the established diagnostic standard for confirming MCAO and assessing obstruction subtype (intrinsic, extrinsic, mixed) and severity, Computed Tomography (CT) serves as an initial screening tool. However, the extent of agreement between CT and bronchoscopy findings for MCAO remains unclear. Methods: To assess the correlation between bronchoscopy and CT, we conducted a retrospective review of 108 patients at Roswell Park Comprehensive Cancer Center, analyzing CT and bronchoscopy results to document MCAO presence, severity, and subtype. Results: CT correctly identified MCAO in 99% of cases (107/108). Agreement regarding obstruction subtype (80.8%, Cohen’s κ = 0.683, p < 0.001), and severity (65%, Quadratic κ = 0.657, p < 0.001) was moderate. CT tended to equally overestimate (7/19) and underestimate (7/19) the degree of obstruction. CT was also poor in identifying mucosal involvement in mixed MCAO. Conclusions: CT demonstrates reasonable agreement with bronchoscopy in detecting obstruction. Nevertheless, when CT indicates a positive finding for MCAO, it is advisable to conduct bronchoscopy. This is because CT lacks reliability in determining the severity of obstruction and identifying the mucosal component of mixed disease.


  • Open Access

    Computational Optimization of Irradiance and Fluence for Interstitial Photodynamic Therapy Treatment of Patients with Malignant Central Airway Obstruction

    by Emily Oakley, Evgueni Parilov, Karl Beeson, Mary Potasek, Nathaniel Ivanick, Lawrence Tworek, Alan Hutson, Gal Shafirstein

    There are no effective treatments for patients with extrinsic malignant central airway obstruction (MCAO). In a recent clinical study, we demonstrated that interstitial photodynamic therapy (I-PDT) is a safe and potentially effective treatment for patients with extrinsic MCAO. In previous preclinical studies, we reported that a minimum light irradiance and fluence should be maintained within a significant volume of the target tumor to obtain an effective PDT response. In this paper, we present a computational approach to personalized treatment planning of light delivery in I-PDT that simultaneously optimizes the delivered irradiance and fluence using finite element method (FEM) solvers of either Comsol Multiphysics® or Dosie™ for light propagation. The FEM simulations were validated with light dosimetry measurements in a solid phantom with tissue-like optical properties. The agreement between the treatment plans generated by two FEMs was tested using typical imaging data from four patients with extrinsic MCAO treated with I-PDT. The concordance correlation coefficient (CCC) and its 95% confidence interval (95% CI) were used to test the agreement between the simulation results and measurements, and between the two FEMs treatment plans. Dosie with CCC = 0.994 (95% CI, 0.953–0.996) and Comsol with CCC = 0.999 (95% CI, 0.985–0.999) showed excellent agreement with light measurements in the phantom. The CCC analysis showed very good agreement between Comsol and Dosie treatment plans for irradiance (95% CI, CCC: 0.996–0.999) and fluence (95% CI, CCC: 0.916–0.987) in using patients’ data. In previous preclinical work, we demonstrated that effective I-PDT is associated with a computed light dose of ≥45 J/cm2 when the irradiance is ≥8.6 mW/cm2 (i.e., the effective rate-based light dose). In this paper, we show how to use Comsol and Dosie packages to optimize rate-based light dose, and we present Dosie’s newly developed domination sub-maps method to improve the planning of the delivery of the effective rate-based light dose. We conclude that image-based treatment planning using Comsol or Dosie FEM-solvers is a valid approach to guide the light dosimetry in I-PDT of patients with MCAO.


  • Open Access

    Management of malignancy-induced, life-threatening hypoxemic respiratory failure using a self-expanding Y stent

    by Nathaniel M. Ivanick, Harshwant Grover, Gregory Fuhrer, Yaron Perry, Subin Sharma, Julia Faller


  • Open Access

    First-In-Human Computer-Optimized Endobronchial Ultrasound-Guided Interstitial Photodynamic Therapy for Patients With Extrabronchial or Endobronchial Obstructing Malignancies

    by Nathaniel M. Ivanick, Emily R. Oakley, Rajesh Kunadharaju, Craig Brackett, David A. Bellnier, Lawrence M. Tworek, Sergei N. Kurenov, Sandra O. Gollnick, Alan D. Hutson, Theresa M. Busch, et al.