Matteo Giuseppe Cereda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Matteo Giuseppe Cereda has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Salvatore Parrulli
Eye Clinic, Department of Biomedical and Clinical Science "Luigi Sacco," Sacco Hospital, University of Milan, Milan, Italy
3 shared publications - Federico Zicarelli
University of Milan
2 shared publications - Ferdinando Bottoni
Eye Clinic, Department of Biomedical and Clinical Sciences "Luigi Sacco," Luigi Sacco Hospital, University of Milan, Milan, Italy
2 shared publications Giovanni Staurenghi
Eye Clinic, Department of Biomedical and Clinical Science "Luigi Sacco", Sacco Hospital, University of Milan, Milan, Italy
2 shared publications- Marco Ferroni
Chemistry, Materials and Chemical Engineering Department "Giulio Natta", Politecnico di Milano, Piazza L. da Vinci 32, Milano, 20133, ITALY
2 shared publications Salvatore Parrulli
Eye Clinic, Department of Biomedical and Clinical Science “Luigi Sacco”, Sacco Hospital, University of Milan, Italy
2 shared publications
Latest Publications
- 20 November 2025
- Published by Wolters Kluwer Health in RETINAL Cases & Brief Reports
Retinal Phototoxicity after pars plana vitrectomy in a patient under Pre-Exposure Prophylaxis (PrEP) for HIV prevention
Purpose: To present a case of suspected retinal phototoxicity after pars plana vitrectomy in a 45-year-old man undergoing Pre-Exposure Prophylaxis (PrEP) for HIV prevention. Methods: Retrospective case report. A 25-gauge pars plana vitrectomy was performed for vitreous hemorrhage and retinal breaks. Standard endo-illumination settings were used. No vital dyes were applied. Despite an initial uneventful surgery, a secondary retinal detachment required a subsequent vitrectomy with gas tamponade. Optical coherence tomography (OCT) and blue fundus autofluorescence were performed at each follow-up visit. Results: Postoperatively, OCT and blue fundus autofluorescence disclosed parafoveal disruption of the outer retinal layers, focal ellipsoid zone discontinuities, and retinal pigment epithelium (RPE) mottling within the illuminated area. At six months, best-corrected visual acuity improved to 20/25, although persistent RPE alterations were evident. Conclusion: The pattern of outer retinal changes suggests a photochemical injury potentiated by photosensitization from PrEP medication. Our findings underscore the need for new strategies to reduce light exposure during surgery in patients on systemic photosensitizing agents.
- 20 November 2025
- Published by Wolters Kluwer Health in RETINAL Cases & Brief Reports
Retinal Phototoxicity after pars plana vitrectomy in a patient under Pre-Exposure Prophylaxis (PrEP) for HIV prevention
Purpose: To present a case of suspected retinal phototoxicity after pars plana vitrectomy in a 45-year-old man undergoing Pre-Exposure Prophylaxis (PrEP) for HIV prevention. Methods: Retrospective case report. A 25-gauge pars plana vitrectomy was performed for vitreous hemorrhage and retinal breaks. Standard endo-illumination settings were used. No vital dyes were applied. Despite an initial uneventful surgery, a secondary retinal detachment required a subsequent vitrectomy with gas tamponade. Optical coherence tomography (OCT) and blue fundus autofluorescence were performed at each follow-up visit. Results: Postoperatively, OCT and blue fundus autofluorescence disclosed parafoveal disruption of the outer retinal layers, focal ellipsoid zone discontinuities, and retinal pigment epithelium (RPE) mottling within the illuminated area. At six months, best-corrected visual acuity improved to 20/25, although persistent RPE alterations were evident. Conclusion: The pattern of outer retinal changes suggests a photochemical injury potentiated by photosensitization from PrEP medication. Our findings underscore the need for new strategies to reduce light exposure during surgery in patients on systemic photosensitizing agents.
- Open Access
- 3 April 2025
- Published by IOP Publishing in Biomedical Materials
- Vol. 20 (3) , 035012
Assessment of magnesium-based components for intraocular drug delivery by in vitro biocompatibility and drug-device interaction
The development of magnesium-based intraocular drug delivery devices holds significant promise for biomedical applications, particularly in treating wet age-related macular degeneration (AMD) using vascular endothelial growth factor inhibitors such as bevacizumab. Magnesium’s rapid degradation, which can be finely tuned to achieve the controlled release required for AMD treatment, along with its well-established biocompatibility and biodegradable properties, positioning it as an ideal material for these applications. The study aimed to evaluate magnesium’s potential as a carrier for ocular drug delivery systems by demontrating the stability of monoclonal antibodies, specifically bevacizumab, in the presence of magnesium corrosion products and the biocompatibility of these products with various cell lines, including murine fibroblasts (3T3), rat retinal Müller cells, and human retinal pigment epithelial cells (ARPE19). The stability of bevacizumab with pure magnesium (Mg) was investigated through an indirect enzyme-linked immunosorbent assay protocol, developed and customized for this specific aim. The biocompatibility of Mg corrosion products was assessed by toxicological evaluations through MTT and Trypan Blue Viability assays, along with cell cycle analysis. Results demonstrated no significant impact of Mg corrosion products on bevacizumab stability, with changes in mean values consistently below or equal to 10%. Furthermore, Mg extracts showed minimal cytotoxicity, as metabolic activity exceeded 80% across all cell lines, classified as Grade 0/1 cytotoxicity under ISO 10993-5 standards. Cell viability, proliferation, and morphology remained unaffected for up to 72 h of exposure. This study provides the first in vitro evaluation of bevacizumab’s stability in the presence of magnesium corrosion products and its biocompatibility with retinal cell lines, laying the foundation for future ophthalmic research and underscoring magnesium’s potential as a material for intraocular drug delivery systems.
- 3 April 2025
- Published by IOP Publishing in Biomedical Materials
- Vol. 20 (3) , 035012
Open AccessAssessment of magnesium-based components for intraocular drug delivery by in vitro biocompatibility and drug-device interaction
The development of magnesium-based intraocular drug delivery devices holds significant promise for biomedical applications, particularly in treating wet age-related macular degeneration (AMD) using vascular endothelial growth factor inhibitors such as bevacizumab. Magnesium’s rapid degradation, which can be finely tuned to achieve the controlled release required for AMD treatment, along with its well-established biocompatibility and biodegradable properties, positioning it as an ideal material for these applications. The study aimed to evaluate magnesium’s potential as a carrier for ocular drug delivery systems by demontrating the stability of monoclonal antibodies, specifically bevacizumab, in the presence of magnesium corrosion products and the biocompatibility of these products with various cell lines, including murine fibroblasts (3T3), rat retinal Müller cells, and human retinal pigment epithelial cells (ARPE19). The stability of bevacizumab with pure magnesium (Mg) was investigated through an indirect enzyme-linked immunosorbent assay protocol, developed and customized for this specific aim. The biocompatibility of Mg corrosion products was assessed by toxicological evaluations through MTT and Trypan Blue Viability assays, along with cell cycle analysis. Results demonstrated no significant impact of Mg corrosion products on bevacizumab stability, with changes in mean values consistently below or equal to 10%. Furthermore, Mg extracts showed minimal cytotoxicity, as metabolic activity exceeded 80% across all cell lines, classified as Grade 0/1 cytotoxicity under ISO 10993-5 standards. Cell viability, proliferation, and morphology remained unaffected for up to 72 h of exposure. This study provides the first in vitro evaluation of bevacizumab’s stability in the presence of magnesium corrosion products and its biocompatibility with retinal cell lines, laying the foundation for future ophthalmic research and underscoring magnesium’s potential as a material for intraocular drug delivery systems.
- 29 November 2024
- Published by Elsevier in Canadian Journal of Ophthalmology
- Vol. 60 (4) , 243-251
Multimodal imaging features of retinal neovascularization in response to 3 anti-VEGF injections
- 29 November 2024
- Published by Elsevier in Canadian Journal of Ophthalmology
- Vol. 60 (4) , 243-251
Multimodal imaging features of retinal neovascularization in response to 3 anti-VEGF injections
- 24 September 2022
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 245, 86-101
Full-Thickness Macular Hole: Are Supra-RPE Granular Deposits Remnants of Photoreceptors Outer Segments? Clinical Implications
- 24 September 2022
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 245, 86-101
Full-Thickness Macular Hole: Are Supra-RPE Granular Deposits Remnants of Photoreceptors Outer Segments? Clinical Implications
- Open Access
- 26 November 2021
- Published by Elsevier in Ophthalmology Science
- Vol. 1 (4) , 100085
Clinical Evaluation of an Instrument-Integrated OCT-Based Distance Sensor for Robotic Vitreoretinal Surgery
- 26 November 2021
- Published by Elsevier in Ophthalmology Science
- Vol. 1 (4) , 100085
Open AccessClinical Evaluation of an Instrument-Integrated OCT-Based Distance Sensor for Robotic Vitreoretinal Surgery
- 2 August 2021
- Published by Elsevier in Canadian Journal of Ophthalmology
- Vol. 58 (1) , 52-58
Functional and anatomic changes between early postoperative recovery and long-term follow-up after combined epiretinal and internal limiting membrane peeling
- 2 August 2021
- Published by Elsevier in Canadian Journal of Ophthalmology
- Vol. 58 (1) , 52-58
Functional and anatomic changes between early postoperative recovery and long-term follow-up after combined epiretinal and internal limiting membrane peeling
- 7 October 2020
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 86 (1) , 20-28
Evaluation of the ocular fluid dynamic effects on intraocular magnesium-based device: A comparison between CFD and FSI approaches
Magnesium is an essential element for the ocular functions and used for the realization of medical devices due to its low corrosion resistance, bioresorbable nature and biocompatibility. Wet age-related macular degeneration is one of the main causes of blindness with patients treated by intravitreal injections of inhibitor drugs. According to the need to reduce the number of injections, the development of new drug delivery devices able to extend the therapeutical outcomes is mandatory and magnesium can be considered as a promising candidate. The aim of the work concerns the evaluation of the ocular fluid dynamic role on a magnesium-based device placed in the vitreous chamber. Particularly, the fluid-induced shear stress field on the surfaces in contact with the liquefied vitreous was studied. Both computational fluid dynamic and fluid-structure interaction approaches were proposed and then compared. Saccadic motion was implemented to recreate the vitreous fluid dynamics. High changes in terms of fluid-induced shear stress field varying the CFD and FSI numerical approaches and kinematic parameters of the saccadic function can be noticed. The comparison between CFD and FSI approaches showed minor significant differences and both implementations suggested the possibility to obtain a uniform and controlled corrosion of the device.
- 7 October 2020
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 86 (1) , 20-28
Evaluation of the ocular fluid dynamic effects on intraocular magnesium-based device: A comparison between CFD and FSI approaches
Magnesium is an essential element for the ocular functions and used for the realization of medical devices due to its low corrosion resistance, bioresorbable nature and biocompatibility. Wet age-related macular degeneration is one of the main causes of blindness with patients treated by intravitreal injections of inhibitor drugs. According to the need to reduce the number of injections, the development of new drug delivery devices able to extend the therapeutical outcomes is mandatory and magnesium can be considered as a promising candidate. The aim of the work concerns the evaluation of the ocular fluid dynamic role on a magnesium-based device placed in the vitreous chamber. Particularly, the fluid-induced shear stress field on the surfaces in contact with the liquefied vitreous was studied. Both computational fluid dynamic and fluid-structure interaction approaches were proposed and then compared. Saccadic motion was implemented to recreate the vitreous fluid dynamics. High changes in terms of fluid-induced shear stress field varying the CFD and FSI numerical approaches and kinematic parameters of the saccadic function can be noticed. The comparison between CFD and FSI approaches showed minor significant differences and both implementations suggested the possibility to obtain a uniform and controlled corrosion of the device.