Nitin Kumar Rajput
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nitin Kumar Rajput has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Alok Kumar Swain
Department of Anaesthesiology and Critical Care, NHMMI Narayana Superspeciality Hospital, Raipur, India
1 shared publication - Anurag Chauhan
Delhi Technological University
1 shared publication - Arun Andappan
Department of Anaesthesiology and Critical Care, NHMMI Narayana Superspeciality Hospital, Raipur, India
1 shared publication Kirandeep Kaur Saini
Delhi Technological University Formerly Delhi College of Engineering, Delhi, India
1 shared publicationRushil Domah
Delhi Technological University Formerly Delhi College of Engineering, Delhi, India
1 shared publication- Tej Kumar Varma Kalangi
Department of Cardiothoracic Surgery, NHMMI Narayana Superspeciality Hospital, Raipur, India
1 shared publication
Latest Publications
- 25 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Implementation of High Performance 4-Bit ALU using Dual Mode Pass Transistor Logic
In this paper, we present a four bit arithmetic logic unit which is energy efficient and temperature invariant implemented using the dual mode pass transistor logic. The basic logic gates such as NOR and NAND are designed using both CMOS logic and dual mode pass transistor logic and are used in the proposed design. Simulations performed demonstrated that DMPL can reduce the computed worst case delay by 42.39%and 39.13%for NOR and NAND gates respectively in dynamic mode and average power dissipation by 67.96%and 24.09%for NOR and NAND gates respectively in static mode. In the implemented Arithmetic and Logic Unit, we observe a reduction in worst case delay and average power dissipation by 62.67%and 28.28%. The proposed logic was implemented in 90nm bulk technology using Cadence® Virtuoso® Schematic Editor.
- 25 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Implementation of High Performance 4-Bit ALU using Dual Mode Pass Transistor Logic
In this paper, we present a four bit arithmetic logic unit which is energy efficient and temperature invariant implemented using the dual mode pass transistor logic. The basic logic gates such as NOR and NAND are designed using both CMOS logic and dual mode pass transistor logic and are used in the proposed design. Simulations performed demonstrated that DMPL can reduce the computed worst case delay by 42.39%and 39.13%for NOR and NAND gates respectively in dynamic mode and average power dissipation by 67.96%and 24.09%for NOR and NAND gates respectively in static mode. In the implemented Arithmetic and Logic Unit, we observe a reduction in worst case delay and average power dissipation by 62.67%and 28.28%. The proposed logic was implemented in 90nm bulk technology using Cadence® Virtuoso® Schematic Editor.
- 7 October 2020
- Published by Springer Nature in Indian Journal of Thoracic and Cardiovascular Surgery
- Vol. 37 (1) , 16-26
MICS CABG: a single-center experience of the first 100 cases
Purpose To study the learning curve and outcomes of the first 100 cases of minimally invasive cardiac surgery (MICS) coronary artery bypass grafting (CABG) performed at our center. Methods From January 2017 to November 2019, a total of 100 patients underwent CABG via left anterior thoracotomy approach. We have studied the operative times within the MICS CABG patients to analyze our learning curve. We also studied the postoperative outcomes and compared these with those of patients who underwent sternotomy during the same period. Results The mean age was 59.33 ± 9.95 (range 37–82) years. The numbers of males and females were 72 and 28 respectively. The preoperative average ejection fraction (EF) was 51.08 ± 9.75%. All these patients underwent CABG via left thoracotomy approach, after satisfying the exclusion criteria. All patients received left internal mammary artery (LIMA) to left anterior descending (LAD) as a standard graft, with the radial artery and saphenous vein being the next alternative conduits. The average length of the incision was 6.06 ± 0.45 cm. Only 2 cases were done on pump. The average number of grafts per patient was 2.33 ± 0.92. The mean operative time was 132.40 ± 11.56 min. The mean duration of ventilation was 4.79 ± 1.90 h and average intensive care unit (ICU) stay was 2.62 ± 0.84 days. There was one conversion and no mortalities in our study. We had analyzed our operative times and noticed a significant reduction after the first 20 cases, which was our learning curve. Conclusion MICS CABG can be performed for multivessel disease with the same comfort as for a single or a double vessel disease, once the learning curve has been achieved. Only significant difference from the sternotomy approach was noted in the longer operative times for MICS CABG during the learning curve, and not thereafter. Significant benefits of MICS over sternotomy were noticed in the immediate postoperative parameters like duration of ventilation, mean drainage, postoperative pain, ICU stay, and hospital stay, with no difference in postoperative adverse events.
- 7 October 2020
- Published by Springer Nature in Indian Journal of Thoracic and Cardiovascular Surgery
- Vol. 37 (1) , 16-26
MICS CABG: a single-center experience of the first 100 cases
Purpose To study the learning curve and outcomes of the first 100 cases of minimally invasive cardiac surgery (MICS) coronary artery bypass grafting (CABG) performed at our center. Methods From January 2017 to November 2019, a total of 100 patients underwent CABG via left anterior thoracotomy approach. We have studied the operative times within the MICS CABG patients to analyze our learning curve. We also studied the postoperative outcomes and compared these with those of patients who underwent sternotomy during the same period. Results The mean age was 59.33 ± 9.95 (range 37–82) years. The numbers of males and females were 72 and 28 respectively. The preoperative average ejection fraction (EF) was 51.08 ± 9.75%. All these patients underwent CABG via left thoracotomy approach, after satisfying the exclusion criteria. All patients received left internal mammary artery (LIMA) to left anterior descending (LAD) as a standard graft, with the radial artery and saphenous vein being the next alternative conduits. The average length of the incision was 6.06 ± 0.45 cm. Only 2 cases were done on pump. The average number of grafts per patient was 2.33 ± 0.92. The mean operative time was 132.40 ± 11.56 min. The mean duration of ventilation was 4.79 ± 1.90 h and average intensive care unit (ICU) stay was 2.62 ± 0.84 days. There was one conversion and no mortalities in our study. We had analyzed our operative times and noticed a significant reduction after the first 20 cases, which was our learning curve. Conclusion MICS CABG can be performed for multivessel disease with the same comfort as for a single or a double vessel disease, once the learning curve has been achieved. Only significant difference from the sternotomy approach was noted in the longer operative times for MICS CABG during the learning curve, and not thereafter. Significant benefits of MICS over sternotomy were noticed in the immediate postoperative parameters like duration of ventilation, mean drainage, postoperative pain, ICU stay, and hospital stay, with no difference in postoperative adverse events.