Martin J.L. Bucx
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Martin J.L. Bucx has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
A. Kammeyer
Biochemist/Researcher, Laboratory of Experimental Dermatology, Academic Medical Center, PO Box 22700, 1100 DE Amsterdam, The Netherlands
1 shared publicationA. Meulemans
Development Engineer, Medical Technological Development Department, and
1 shared publication- Anne A. M. W. van Kempen
Department of Pediatrics and Neonatology, OLVG, Amsterdam, The Netherlands
1 shared publication Dds Jerôme A.H. Lindeboom Md
Oral and Maxillofacial Surgery
1 shared publicationFrea H. Kruisinga
Department of Neonatology
1 shared publicationH. M. De Gast
Staff Anaesthesiologist, Department of Anaesthesiology, Slotervaart Hospital, Amsterdam, The Netherlands
1 shared publication
Latest Publications
- 3 July 2003
- Published by Wiley in Pediatric Anesthesia
- Vol. 13 (6) , 530-533
The prolonged use of the laryngeal mask airway in a neonate with airway obstruction and Treacher Collins syndrome
Summary: Upper airway obstruction and difficult tracheal intubation are often encountered in patients with Treacher Collins syndrome (mandibulofacial dysostosis). In this case report, the use of a laryngeal mask airway (LMATM) in a 10‐day‐old newborn with severe Treacher Collins syndrome and acute airway obstruction is described. It successfully relieved the airway obstruction and was left in situ for an exceptionally long period of 4 days. The difficult decisions with respect to the management of the airway and specifically the role of the laryngeal mask are described. In our opinion, in some newborns with severe mandibulofacial disorders and upper airway obstruction, where conservative airway management procedures have failed, the laryngeal mask can be considered not only to relieve the obstruction but also to buy time until there is full insight into the medical condition and its consequences.
- 3 July 2003
- Published by Wiley in Pediatric Anesthesia
- Vol. 13 (6) , 530-533
The prolonged use of the laryngeal mask airway in a neonate with airway obstruction and Treacher Collins syndrome
Summary: Upper airway obstruction and difficult tracheal intubation are often encountered in patients with Treacher Collins syndrome (mandibulofacial dysostosis). In this case report, the use of a laryngeal mask airway (LMATM) in a 10‐day‐old newborn with severe Treacher Collins syndrome and acute airway obstruction is described. It successfully relieved the airway obstruction and was left in situ for an exceptionally long period of 4 days. The difficult decisions with respect to the management of the airway and specifically the role of the laryngeal mask are described. In our opinion, in some newborns with severe mandibulofacial disorders and upper airway obstruction, where conservative airway management procedures have failed, the laryngeal mask can be considered not only to relieve the obstruction but also to buy time until there is full insight into the medical condition and its consequences.
- Open Access
- 15 April 2003
- Published by Wiley in Anaesthesia
- Vol. 58 (5) , 461-465
The effect of mechanical cleaning and thermal disinfection on light intensity provided by fibrelight Macintosh laryngoscopes
Summary The increased use of thermal decontamination procedures for fibrelight laryngoscope blades, to comply with international guidelines, will have considerable economical effects. We evaluated the effect of mechanical cleaning plus thermal disinfection at 90°C, with or without subsequent steam sterilisation at 134°C, on light intensity provided by fibrelight laryngoscopes. After mounting the blades in a special frame with a built‐in light source, light intensity was measured using radiometer/photometer. In total, 14 blades provided by 11 companies were tested. The majority of fibrelight laryngoscope blades were fairly resistant to the damaging effects of machine washing plus disinfection at 90°C (mean [range] reduction in light intensity 34.6%[2.1–78.3%]). However, when exposed to an additional sterilisation procedure at 134°C, the majority of blades were unable to withstand the combined treatment for 300 cycles (mean [range] reduction in light intensity 86.5%[32.0–98.7%]). This study stresses the need for fibrelight laryngoscope blades which are more resistant to thermal decontamination procedures than those available at present.
- 15 April 2003
- Published by Wiley in Anaesthesia
- Vol. 58 (5) , 461-465
Open AccessThe effect of mechanical cleaning and thermal disinfection on light intensity provided by fibrelight Macintosh laryngoscopes
Summary The increased use of thermal decontamination procedures for fibrelight laryngoscope blades, to comply with international guidelines, will have considerable economical effects. We evaluated the effect of mechanical cleaning plus thermal disinfection at 90°C, with or without subsequent steam sterilisation at 134°C, on light intensity provided by fibrelight laryngoscopes. After mounting the blades in a special frame with a built‐in light source, light intensity was measured using radiometer/photometer. In total, 14 blades provided by 11 companies were tested. The majority of fibrelight laryngoscope blades were fairly resistant to the damaging effects of machine washing plus disinfection at 90°C (mean [range] reduction in light intensity 34.6%[2.1–78.3%]). However, when exposed to an additional sterilisation procedure at 134°C, the majority of blades were unable to withstand the combined treatment for 300 cycles (mean [range] reduction in light intensity 86.5%[32.0–98.7%]). This study stresses the need for fibrelight laryngoscope blades which are more resistant to thermal decontamination procedures than those available at present.