  • The prolonged use of the laryngeal mask airway in a neonate with airway obstruction and Treacher Collins syndrome

    by Martin J.L. Bucx, W. Grolman, Frea H. Kruisinga, Dds Jerôme A.H. Lindeboom Md, Anne A.M.W Van Kempen

    Summary: Upper airway obstruction and difficult tracheal intubation are often encountered in patients with Treacher Collins syndrome (mandibulofacial dysostosis). In this case report, the use of a laryngeal mask airway (LMATM) in a 10‐day‐old newborn with severe Treacher Collins syndrome and acute airway obstruction is described. It successfully relieved the airway obstruction and was left in situ for an exceptionally long period of 4 days. The difficult decisions with respect to the management of the airway and specifically the role of the laryngeal mask are described. In our opinion, in some newborns with severe mandibulofacial disorders and upper airway obstruction, where conservative airway management procedures have failed, the laryngeal mask can be considered not only to relieve the obstruction but also to buy time until there is full insight into the medical condition and its consequences.


  • Open Access

    The effect of mechanical cleaning and thermal disinfection on light intensity provided by fibrelight Macintosh laryngoscopes

    by M. J. L. Bucx, H. M. De Gast, J. Veldhuis, L. H. Hassing, A. Meulemans, A. Kammeyer

    Summary The increased use of thermal decontamination procedures for fibrelight laryngoscope blades, to comply with international guidelines, will have considerable economical effects. We evaluated the effect of mechanical cleaning plus thermal disinfection at 90°C, with or without subsequent steam sterilisation at 134°C, on light intensity provided by fibrelight laryngoscopes. After mounting the blades in a special frame with a built‐in light source, light intensity was measured using radiometer/photometer. In total, 14 blades provided by 11 companies were tested. The majority of fibrelight laryngoscope blades were fairly resistant to the damaging effects of machine washing plus disinfection at 90°C (mean [range] reduction in light intensity 34.6%[2.1–78.3%]). However, when exposed to an additional sterilisation procedure at 134°C, the majority of blades were unable to withstand the combined treatment for 300 cycles (mean [range] reduction in light intensity 86.5%[32.0–98.7%]). This study stresses the need for fibrelight laryngoscope blades which are more resistant to thermal decontamination procedures than those available at present.