AKAdeline Kabacinski

Adeline Kabacinski

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Adeline Kabacinski has a total of 51 co-authors. Here are the top co-authors by number of shared publications:

  • Fabien Tissandier

    Laboratoire d’Optique Appliquée, ENSTA-Paristech, CNRS, Ecole Polytechnique, Institut Polytechnique de Paris, Palaiseau, France

    7 shared publications
  • Jean-Philippe Goddet

    Laboratoire d’Optique Appliquée, ENSTA-Paristech, CNRS, Ecole Polytechnique, Institut Polytechnique de Paris, Palaiseau, France

    5 shared publications
  • Julien Gautier

    Laboratoire d'Optique Appliquée, ENSTA-Paristech, CNRS, Ecole Polytechnique, Institut Polytechnique de Paris, 828 Bv des Maréchaux, 91762 Palaiseau, France

    4 shared publications
  • Stéphane Sebban

    Lab. d’Optique Appliquée, ENSTA Paris, Ecole Polytechnique, Institut Polytechnique de Paris, CNRS (France)

    4 shared publications
  • Amar Tafzi

    Laboratoire d'optique appliquée, palaiseau, FRANCE

    3 shared publications
  • Julien Gautier

    Laboratoire d’Optique Appliquée

    3 shared publications

Latest Publications

  • Spatio-temporal couplings for controlling group velocity in longitudinally pumped seeded soft X-ray lasers

    by Adeline Kabacinski, Eduardo Oliva, Fabien Tissandier, Julien Gautier, Michaela Kozlová, Jean-Philippe Goddet, Igor A. Andriyash, Cédric Thaury, Philippe Zeitoun, Stéphane Sebban


  • Open Access

    Femtosecond soft x-ray lasing in dense collisionaly-pumped plasma

    by Adeline Kabacinski, Fabien Tissandier, Julien Gautier, Jean-Philippe Goddet, Igor Andriyash, Philippe Zeitoun, Stéphane Sebban, Eduardo Oliva, Michaela Kozlová

    We report the first experimental measurement of a strong pulse shortening of a seeded plasma-based soft x-ray laser at high electron densities. As a consequence of the gain gating caused by subsequent collisional ionization, the duration drops from 1.4 ps to an unprecedented value of 520 fs RMS when the electron density increases from 4 to 7.6×1019cm−3. These measurements, performed with an original single-shot method, are in good agreement with results from 3D Maxwell-Bloch simulations.


  • Open Access

    Single-shot wavefront characterization of high topological charge extreme-ultraviolet vortex

    by Alok Kumar Pandey, Olivier Guilbaud, Fabrice Sanson, Irene Papagiannouli, Adeline Kabacinski, Fabien Tissandier, Fabrice Harms, Guillaume Beaugrand, Guillaume Dovillaire, Elsa Baynard, et al.

    It is known that light beams carry linear as well as angular momenta. The spin angular momentum (SAM) of photons is related to polarization [1]. On the other hand, orbital angular momentum (OAM) is independent of the polarization and is related to the wavefront instead [2]. Such beams, also known as optical vortices, exhibit a transverse helical phase with еilФ dependence around the beam propagation axis. A rapid phase rotation around the center results in an on-axis phase singularity yielding a donut-like intensity profile with a dark-hole at the center. There are two main attributes for such beams: (1) the topological charge l is the number of 2π phase shifts along the azimuthal coordinate Φ of the beam, and (2) for a vortex beam of topological charge l, each photon carries an OAM of lħ [2]. Moreover, unlike the intrinsic nature of SAM, the OAM of helically phased beams can either be intrinsic or extrinsic [3].


  • Open Access

    Table-top extreme ultraviolet second harmonic generation

    by Tobias Helk, Emma Berger, Sasawat Jamnuch, Lars Hoffmann, Adeline Kabacinski, Julien Gautier, Fabien Tissandier, Jean-Philipe Goddet, Hung-Tzu Chang, Juwon Oh, et al.

    The lack of available table-top extreme ultraviolet (XUV) sources with high enough fluxes and coherence properties has limited the availability of nonlinear XUV and x-ray spectroscopies to free-electron lasers (FELs). Here, we demonstrate second harmonic generation (SHG) on a table-top XUV source by observing SHG near the Ti M2,3 edge with a high-harmonic seeded soft x-ray laser. Furthermore, this experiment represents the first SHG experiment in the XUV. First-principles electronic structure calculations suggest the surface specificity and separate the observed signal into its resonant and nonresonant contributions. The realization of XUV-SHG on a table-top source opens up more accessible opportunities for the study of element-specific dynamics in multicomponent systems where surface, interfacial, and bulk-phase asymmetries play a driving role.


  • Measurement and control of main spatio-temporal couplings in a CPA laser chain

    by Adeline Kabacinski, Kosta Oubrerie, Jean-Philippe Goddet, Julien Gautier, Fabien Tissandier, Olena Kononenko, Amar Tafzi, Adrien Leblanc, Stéphane Sebban, Cédric Thaury

    We report a straightforward method to control main spatio-temporal couplings in a chirped pulse amplification (CPA) laser chain system using a specially designed chromatic doublet in a divergent beam configuration. The centering of the doublet allows for the control of the spatial chirp of the CPA laser chain, while its longitudinal position in the divergent beam enables the control of the amount of longitudinal chromatism in a wide dynamic range. The performance of this technique is evaluated by measuring main spatio-temporal couplings with a simple method, based on an ultrafast pulse shaper, which allows for a selection of narrow windows of the spectrum.


  • Open Access

    Measurement and Control of Main Spatio-Temporal Couplings in a CPA Laser Chain

    by Adeline Kabacinski, Kosta Oubrerie, Jean-Philippe Goddet, Julien Gautier, Fabien Tissandier, Olena Kononenko, Amar Tafzi, Adrien Leblanc, Stéphane Sebban, Cédric Thaury

    We report a straightforward method to control main spatio-temporal couplings in a CPA laser chain system using a specially designed chromatic doublet in a divergent beam configuration. The centering of the doublet allows for the control of the spatial chirp of the CPA laser chain, while its longitudinal position in the divergent beam enables the control of the amount of longitudinal chromatism in a wide dynamic range. The performance of this technique is evaluated by measuring main spatio-temporal couplings with a simple method, based on an ultrafast pulse shaper, which allows for a selection of narrow windows of the spectrum.

  • Monitoring shot-to-shot variations of soft x-ray sources using aluminum foils

    by Adeline Kabacinski, Fabien Tissandier, Julien Gautier, Jean-Philippe Goddet, Amar Tafzi, Stéphane Sebban

    We report a straightforward beam splitter in the soft x-ray spectral range using a thin oxidized aluminum foil. As it allows us to monitor reliably shot-to-shot variations in energy and in energy distribution, this beam splitter is of high interest for the simultaneous use of diagnostics for soft x-rays sources. We measure a transmission of 0.5 and a reflectivity of 0.018 at 22.5° of incidence with a soft x-ray laser working at 32.8 nm. These values are in good agreement with the theory. As the theory predicts a reflectivity and a transmission of both 12% at 52.5° of incidence for 32.8 nm, it can also be useful for experiments that require the division and recombination of a beam, for instance, interferometry or pump-probe technique with an intense soft x-ray source.


  • Open Access

    Table-top Nonlinear Extreme Ultraviolet Spectroscopy

    by T. Helk, E. Berger, S. Jamnuch, L. Hoffmann, A. Kabacinski, J. Gautier, F. Tissandier, J. P. Goddet, H. -T. Chang, J. Oh, et al.

    The lack of available table-top extreme ultraviolet (XUV) sources with high enough fluxes and coherence properties have limited the availability of nonlinear XUV and x-ray spectroscopies to free electron lasers (FEL). Here, we demonstrate second harmonic generation (SHG) on a table-top XUV source for the first time by observing SHG at the Ti M2,3-edge with a high harmonic seeded soft x-ray laser (HHG-SXRL) [1,2]. Further, this experiment represents the first SHG experiment in the XUV. First-principles electronic structure calculations are used to confirm the surface specificity and resonant enhancement of the SHG signal. The realization of XUV-SHG on a table-top source with femtosecond temporal resolution opens up tremendous opportunities for the study of element-specific dynamics in multi-component systems where surface, interfacial, and bulk-phase asymmetries play a driving role in smaller-scale labs as opposed to FELs.