Zhenyu Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zhenyu Wu has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Siliang Lu
Anhui University
4 shared publications - Yongbin Liu
Anhui University
4 shared publications - Cungang Hu
School of Electrical Engineering and Automation, Anhui University, Hefei, China
3 shared publications - Hui Wang
China Electric Power Research Institute, Beijing, China
3 shared publications - Dongyang Wang
School of Electrical Engineering, Southwest Jiaotong University, Chengdu, Sichuan Province, China
2 shared publications - Feiming Jiang
Kunming Power Supply Bureau, Yunnan Power Grid Company Ltd., Kunming, China
2 shared publications
Latest Publications
- 29 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. PP (08858969) , 1-15
Interturn Short-Circuit Fault Diagnosis of A BLDC Hub Motor Via Graph Neural Networks with Multiscale Feature Distillation
Brushless DC motors (BLDCMs) have become the preferred choice for hub motor drives because of their high efficiency, high power density, and excellent speed–torque characteristics. As latent faults in motors, interturn short circuits (ITSCs) cause the spatial electromagnetic distribution to exhibit differential responses, which leads to scattered electromagnetic information distribution and excessive redundant information, and poses challenges for state assessment. These issues are addressed in this study by proposing a multiscale feature distillation-based graph neural network (MSFD-GNN) architecture for noninvasive online diagnosis of ITSC. First, the correlation between leakage magnetic signals and winding states under ITSC is analyzed by establishing an equivalent magnetic circuit model and incorporating finite element analysis. Second, spatially dispersed multichannel leakage magnetic signals are transformed into information-dense electromagnetic field feature maps by integrating recursive phase space reconstruction techniques. The designed MSFD module subsequently performs adaptive refinement and enhancement of fault features, followed by cascading GNNs to learn global topological features by aggregating node neighborhood information. The experimental results demonstrate that the proposed method effectively identifies the severity and location of ITSC faults, achieving a comprehensive diagnostic accuracy of 99.62% across multiple operating conditions.
- 29 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. PP (08858969) , 1-15
Interturn Short-Circuit Fault Diagnosis of A BLDC Hub Motor Via Graph Neural Networks with Multiscale Feature Distillation
Brushless DC motors (BLDCMs) have become the preferred choice for hub motor drives because of their high efficiency, high power density, and excellent speed–torque characteristics. As latent faults in motors, interturn short circuits (ITSCs) cause the spatial electromagnetic distribution to exhibit differential responses, which leads to scattered electromagnetic information distribution and excessive redundant information, and poses challenges for state assessment. These issues are addressed in this study by proposing a multiscale feature distillation-based graph neural network (MSFD-GNN) architecture for noninvasive online diagnosis of ITSC. First, the correlation between leakage magnetic signals and winding states under ITSC is analyzed by establishing an equivalent magnetic circuit model and incorporating finite element analysis. Second, spatially dispersed multichannel leakage magnetic signals are transformed into information-dense electromagnetic field feature maps by integrating recursive phase space reconstruction techniques. The designed MSFD module subsequently performs adaptive refinement and enhancement of fault features, followed by cascading GNNs to learn global topological features by aggregating node neighborhood information. The experimental results demonstrate that the proposed method effectively identifies the severity and location of ITSC faults, achieving a comprehensive diagnostic accuracy of 99.62% across multiple operating conditions.
- Open Access
- 10 December 2025
- Published by International Society for Translational Science in Engineering Education Review
- Vol. 3
Design of the main teaching line for the major of electrical engineering and its automation under the guidance of new engineering education
The new engineering education (NEE) initiative has been implemented to address the imbalance between theory and integration in the context of the energy transition and advancements in smart grids. This initiative involves curriculum reform in the field of electrical engineering and its automation. Utilising Anhui University as a case study, this work delineates a 'main teaching line'—a curriculum design method that fosters versatile talents skilled in intelligence, energy and practice, integrating vertical knowledge building and horizontal industry–academia integration. The model outlines a four-tier vertical structure (Foundation–Professional Foundation–Major–Comprehensive) and two horizontal dimensions (interdisciplinary and industry-education integration). The curriculum is structured around a series of core courses, including circuit theory, electrical machinery and power system analysis. The pedagogical approach is founded on a reverse decomposition strategy, with the curriculum meticulously designed to align with the national electrical code (NEC) objectives. This approach involves a systematic analysis of knowledge links and a comprehensive assessment of outcomes, ensuring that the educational objectives are effectively met. The approach establishes a model for NEE reform at local universities and cultivates talent aligned with the needs of the energy revolution.
- 10 December 2025
- Published by International Society for Translational Science in Engineering Education Review
- Vol. 3
Open AccessDesign of the main teaching line for the major of electrical engineering and its automation under the guidance of new engineering education
The new engineering education (NEE) initiative has been implemented to address the imbalance between theory and integration in the context of the energy transition and advancements in smart grids. This initiative involves curriculum reform in the field of electrical engineering and its automation. Utilising Anhui University as a case study, this work delineates a 'main teaching line'—a curriculum design method that fosters versatile talents skilled in intelligence, energy and practice, integrating vertical knowledge building and horizontal industry–academia integration. The model outlines a four-tier vertical structure (Foundation–Professional Foundation–Major–Comprehensive) and two horizontal dimensions (interdisciplinary and industry-education integration). The curriculum is structured around a series of core courses, including circuit theory, electrical machinery and power system analysis. The pedagogical approach is founded on a reverse decomposition strategy, with the curriculum meticulously designed to align with the national electrical code (NEC) objectives. This approach involves a systematic analysis of knowledge links and a comprehensive assessment of outcomes, ensuring that the educational objectives are effectively met. The approach establishes a model for NEE reform at local universities and cultivates talent aligned with the needs of the energy revolution.
- Open Access
- 8 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 141064-141078
Improved Measurement Method for Locating Winding Faults in On-Board Transformers in High-Speed Trains
Frequency response analysis (FRA) is a widely used fault diagnosis approach for transformer windings. However, its application to on-board transformers in high-speed trains faces challenges because the four groups of high-voltage (HV) windings are often connected in parallel, making it impossible to measure them separately outside the oil tank. Additionally, locating winding faults becomes more difficult because the condition of the windings changes over time, and prior knowledge about the winding status is not always readily available. This paper proposes an improved measurement method for locating winding faults without reference data. The method establishes multiple signal transmission paths between the HV windings and traction windings through a superimposed series–parallel connection to the winding terminals. The responses of the traction windings are measured simultaneously when excitation is imposed on the HV windings, and the faulty windings are detected based on the symmetry of the responses between the terminals. The correlation coefficient and the sum of resonant peak amplitudes are proposed to evaluate the windin status. First, a finite element method model and an experimental transformer are established to evaluate the efficacy of the proposed method. Experimental studies are then conducted. Test results show that the shift direction, correlation coefficient, and the sum of resonant peak amplitudes are effective in identifying faulty windings. For the FRA signatures of the faulty winding, the correlation coefficients remain around 5 in the low-frequency band, while they all drop below 1 in the mid-to-high frequency bands. The shift direction of the FRA signatures are closely correlated with the type of winding fault. Regarding resonant peak amplitudes, their sum remains stable in the low-frequency band. However, it increases in the medium-frequency band before decreasing in the high-frequency band. This finding confirms that the proposed measurement method can successfully capture fault diagnostic information and locate the faults without the need for reference data. The accuracy of the fault location of the on-board transformer is significantly improved.
- 8 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 141064-141078
Open AccessImproved Measurement Method for Locating Winding Faults in On-Board Transformers in High-Speed Trains
Frequency response analysis (FRA) is a widely used fault diagnosis approach for transformer windings. However, its application to on-board transformers in high-speed trains faces challenges because the four groups of high-voltage (HV) windings are often connected in parallel, making it impossible to measure them separately outside the oil tank. Additionally, locating winding faults becomes more difficult because the condition of the windings changes over time, and prior knowledge about the winding status is not always readily available. This paper proposes an improved measurement method for locating winding faults without reference data. The method establishes multiple signal transmission paths between the HV windings and traction windings through a superimposed series–parallel connection to the winding terminals. The responses of the traction windings are measured simultaneously when excitation is imposed on the HV windings, and the faulty windings are detected based on the symmetry of the responses between the terminals. The correlation coefficient and the sum of resonant peak amplitudes are proposed to evaluate the windin status. First, a finite element method model and an experimental transformer are established to evaluate the efficacy of the proposed method. Experimental studies are then conducted. Test results show that the shift direction, correlation coefficient, and the sum of resonant peak amplitudes are effective in identifying faulty windings. For the FRA signatures of the faulty winding, the correlation coefficients remain around 5 in the low-frequency band, while they all drop below 1 in the mid-to-high frequency bands. The shift direction of the FRA signatures are closely correlated with the type of winding fault. Regarding resonant peak amplitudes, their sum remains stable in the low-frequency band. However, it increases in the medium-frequency band before decreasing in the high-frequency band. This finding confirms that the proposed measurement method can successfully capture fault diagnostic information and locate the faults without the need for reference data. The accuracy of the fault location of the on-board transformer is significantly improved.
- 25 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
Detection of Structure Deformation and Insulation Condition for Transformer Windings Based on High-Voltage Oscillating Wave
The efficient and accurate detection of the mechanical structure and insulation condition of transformer windings is a key prerequisite for condition assessment and maintenance. However, an effective detection method for latent inter-turn insulation fault has yet to be developed. Moreover, the existing routine tests vary and are time consuming. The test conditions of different test items also vary remarkably, leading to the corresponding replacement of the detection device and the test cable, which makes the detection time of a single project often insufficient, thus seriously affecting the test results. Therefore, this study proposes an integrated detection method based on high-voltage oscillating waves. Firstly, the principle of latent inter-turn insulation fault diagnosis is theoretically analysed, and the integrated detection steps of winding mechanical structure, insulation resistance, dielectric loss and leakage current are further introduced. Secondly, a model test platform of proportional transformer is constructed to simulate various faults. A traditional detection method and oscillating wave detection are conducted, and the detection results are compared and analysed. Finally, high-voltage oscillating wave detection is performed for the actual 110 kV transformer with defects. Results show that the proposed detection method has high fault sensitivity for turn-to-turn insulation fault, mechanical deformation and main insulation fault. The detection results are consistent with the traditional detection methods, thus verifying the feasibility of the method and the sensitivity of fault diagnosis.
- 25 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
Detection of Structure Deformation and Insulation Condition for Transformer Windings Based on High-Voltage Oscillating Wave
The efficient and accurate detection of the mechanical structure and insulation condition of transformer windings is a key prerequisite for condition assessment and maintenance. However, an effective detection method for latent inter-turn insulation fault has yet to be developed. Moreover, the existing routine tests vary and are time consuming. The test conditions of different test items also vary remarkably, leading to the corresponding replacement of the detection device and the test cable, which makes the detection time of a single project often insufficient, thus seriously affecting the test results. Therefore, this study proposes an integrated detection method based on high-voltage oscillating waves. Firstly, the principle of latent inter-turn insulation fault diagnosis is theoretically analysed, and the integrated detection steps of winding mechanical structure, insulation resistance, dielectric loss and leakage current are further introduced. Secondly, a model test platform of proportional transformer is constructed to simulate various faults. A traditional detection method and oscillating wave detection are conducted, and the detection results are compared and analysed. Finally, high-voltage oscillating wave detection is performed for the actual 110 kV transformer with defects. Results show that the proposed detection method has high fault sensitivity for turn-to-turn insulation fault, mechanical deformation and main insulation fault. The detection results are consistent with the traditional detection methods, thus verifying the feasibility of the method and the sensitivity of fault diagnosis.
- 13 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
Diagnosis of Interturn Short Circuit Fault in BLDCM Based on Coupled High-Frequency Signal Injection
The Brushless DC motors (BLDCMs) are a key technology for electric vehicles (EVs) as they exhibit excellent performance in terms of high efficiency and controllability. However, their reliability poses a technical challenge where inter-turn short circuit (ITSC) faults are a major type of faults. Detecting these faults quickly and reliably can save lives and reduce the operational costs. A method for diagnosing ITSC faults in BLDCMs is proposed in this paper, which employs a coupled high-frequency (HF) signal injection technique. The HF detection signals are injected into the motor windings through a coupling circuit, and the three-phase HF currents at the injected frequency are obtained to analyze the fault characteristics. The root-mean-square (RMS) ratios of the HF currents are used as fault indicators. The effectiveness of proposed method is confirmed by both simulation and experimental tests. It is proven to be resilient to environmental factors and measurement noise. The developed technology will gain in popularity of the BLDCMs in the applications of green transportation such as EVs, electric aircraft and ships.
- 13 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
Diagnosis of Interturn Short Circuit Fault in BLDCM Based on Coupled High-Frequency Signal Injection
The Brushless DC motors (BLDCMs) are a key technology for electric vehicles (EVs) as they exhibit excellent performance in terms of high efficiency and controllability. However, their reliability poses a technical challenge where inter-turn short circuit (ITSC) faults are a major type of faults. Detecting these faults quickly and reliably can save lives and reduce the operational costs. A method for diagnosing ITSC faults in BLDCMs is proposed in this paper, which employs a coupled high-frequency (HF) signal injection technique. The HF detection signals are injected into the motor windings through a coupling circuit, and the three-phase HF currents at the injected frequency are obtained to analyze the fault characteristics. The root-mean-square (RMS) ratios of the HF currents are used as fault indicators. The effectiveness of proposed method is confirmed by both simulation and experimental tests. It is proven to be resilient to environmental factors and measurement noise. The developed technology will gain in popularity of the BLDCMs in the applications of green transportation such as EVs, electric aircraft and ships.
- 3 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-13
Feature Analysis of Oscillating Wave Signal for Axial Displacement in Autotransformer
A new testing method (oscillating wave method) has been proposed as a solution to the problem of short maintenance time in traction power supply system, which could complete tests of winding and insulation via one connection and improve the maintenance efficiency of the transformer. Through the method being proved highly sensitive to winding faults, the variation under different winding states, however, remains unclear. This paper aims to analyze oscillating wave signatures in the occurrence of axial displacement (AD). Firstly, the modeling method will be proposed that can simulate oscillating wave signatures in different winding states. Then, the time-domain feature and the new proposed frequency-domain feature are applied to analyze the fault extent and location of AD fault. The results show that this model accurately simulates oscillating wave signatures. Moreover, the time-domain feature (Euclidean distance-ED) is closely related to fault extent. The combined use of the time-domain feature (ED) and frequency-domain feature (W-Energy entropy in Z-Score) is effective in the identification of fault location. These features, therefore, can provide the reference for winding state evaluation.
- 3 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-13
Feature Analysis of Oscillating Wave Signal for Axial Displacement in Autotransformer
A new testing method (oscillating wave method) has been proposed as a solution to the problem of short maintenance time in traction power supply system, which could complete tests of winding and insulation via one connection and improve the maintenance efficiency of the transformer. Through the method being proved highly sensitive to winding faults, the variation under different winding states, however, remains unclear. This paper aims to analyze oscillating wave signatures in the occurrence of axial displacement (AD). Firstly, the modeling method will be proposed that can simulate oscillating wave signatures in different winding states. Then, the time-domain feature and the new proposed frequency-domain feature are applied to analyze the fault extent and location of AD fault. The results show that this model accurately simulates oscillating wave signatures. Moreover, the time-domain feature (Euclidean distance-ED) is closely related to fault extent. The combined use of the time-domain feature (ED) and frequency-domain feature (W-Energy entropy in Z-Score) is effective in the identification of fault location. These features, therefore, can provide the reference for winding state evaluation.
- 9 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (11) , 9203-9214
A New Testing Method for the Diagnosis of Winding Faults in Transformer
In this paper, a new testing method for the diagnose of winding faults based on the resonant frequency of the transformer is proposed. The system which consists of the high-voltage DC power and high-voltage IGBT could charge the transformer periodically. The response measured from the bushing of the winding is the oscillating wave that can be used for evaluating the status. Carrying out the new test on 220kV three winding, three-phase transformer in the field, the tests of insulation and the winding have been completed in one test. The calculated frequency verifies the feasibility and applicability of the method in theory and the voltage does not affect the resonant frequency in the test. The three winding, three-phase model transformer was built to simulate the various parameters of the power supply, which proves that the features of the oscillating waves are brought about by the properties of the transformer. And that, the new testing method provide a new opportunity to do parameter identification of axial displacement and short circuit (SC) fault. The above research shows that the proposed method can conduct the test of winding and insulation in one test for a short time, which proves a reference in the field.
- 9 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (11) , 9203-9214
A New Testing Method for the Diagnosis of Winding Faults in Transformer
In this paper, a new testing method for the diagnose of winding faults based on the resonant frequency of the transformer is proposed. The system which consists of the high-voltage DC power and high-voltage IGBT could charge the transformer periodically. The response measured from the bushing of the winding is the oscillating wave that can be used for evaluating the status. Carrying out the new test on 220kV three winding, three-phase transformer in the field, the tests of insulation and the winding have been completed in one test. The calculated frequency verifies the feasibility and applicability of the method in theory and the voltage does not affect the resonant frequency in the test. The three winding, three-phase model transformer was built to simulate the various parameters of the power supply, which proves that the features of the oscillating waves are brought about by the properties of the transformer. And that, the new testing method provide a new opportunity to do parameter identification of axial displacement and short circuit (SC) fault. The above research shows that the proposed method can conduct the test of winding and insulation in one test for a short time, which proves a reference in the field.