DGDaniele Gatti

Daniele Gatti

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Daniele Gatti has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • An Ultrasonic Heading Goniometer Intrinsically Robust to Magnetic Interference

    by Pasquale Arpaia, Umberto Cesaro, Daniele Gatti, Nicola Moccaldi

    An ultrasonic heading measurement method, working under magnetic interference prohibitive for magnetometers, was prototyped, validated, and metrologically characterized. Two capacitive ultrasonic transducers convert the mechanical rotation in two correspondingly time-delayed electrical sine waves. Then, the time delay is estimated using the standard tree parameter sine-fitting algorithm. The prototyped goniometer achieves the same repeatability level (< 36 mrad) of a magnetometer-based heading in the range [-437 mrad, 437 mrad]. Simultaneously, a throughput of 505 Sa/s is proved on an STM32F303xC Arm® Cortex® -M4 32-bit micro-controller. An interference analysis revealed the experimental deterministic error well explained by the combined effect of beacon and receiver directivity, as well as by the relative position of beacon, receiver, and reflective surfaces. Noise robustness was assessed in case of SNR decayed to 9.1 dB from the initial value of 36.6 dB: the maximum deterministic error in the range [-437 mrad, 437 mrad] increased less than 10% (from 21 mrad to 23 mrad in absolute value).


  • Open Access

    Augmented Reality monitoring of robot-assisted intervention in harsh environments at CERN

    by Leopoldo Angrisani, Pasquale Arpaia, Daniele Gatti, Alessandro Masi, Mario Di Castro

    An architecture of human-robot navigation system, based on ultra-wideband positioning, twofold ultrasonic sensors for heading, and an augmented reality smart-glasses interface, is presented. The position is obtained by a trilateration algorithm based on Extended Kalman Filter, and the heading by fusing the ultra-wideband position with the phase difference measured by the ultrasonic system. The phase difference received at the ultrasonic sensor is extract using the three parameter sine fitting algorithm. For this application in the CERN tunnel of the Large Hadron Collider, the inspection robot precedes the human during the navigation in the harsh environment, and collects temperature, oxygen percentage, and radiation level. The environment measurements are displayed by the smart-glasses at the operator, and in case of a dangerous condition, the operator is warned by the augmented reality interface. The navigation and monitoring system allows to maintain safety the relative human-robot position. Preliminary simulation results of the positioning and heading system are discussed to validate the main idea.


  • Analysis of localization technologies for indoor environment

    by Leopoldo Angrisani, Pasquale Arpaia, Daniele Gatti

    Scientific proposals of indoor positioning and range measurement are reviewed, with a discussion of their advantages and disadvantages. The considered technologies are: Radio Frequency, Ultrasonic, Camera-based solution, and Infrared. The typical constraints in indoor environments are high accuracy, low latency, low dimensions, and low energy dissipation.


  • Fast beacon recognition for accurate ultrasonic indoor positioning

    by Leopoldo Angrisani, Pasquale Arpaia, Daniele Gatti

    A proof-of-principle demonstrator based on ultra-sonic technology capable of identifying the beacon node within 450 μs is discussed. Time difference of arrival is measured by means of a microcontroller-based board Nucleo STM32 L152RE combined with a custom receiving circuit. The position is computed using a personal computer after the demonstrator acquisition. The demonstrator is validated by static 2D position measurements using two synchronized emitting beacon nodes in a 1.8 m × 2.0 m area with an accuracy of 5.59 cm.