Dan Li
Research Subjects
Dan Li has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Aying Jiwa
School of Information Technology, Xichang University,Xichang,China
2 shared publications- Longke He
School of Information Technology, Xichang University,Xichang,China
2 shared publications Zhengcong Du
Yibin University,Department of Artificial Intelligence and Big Data,Yibin,China
2 shared publications- Chen Chen
Shanghai Institute of Technology
1 shared publication - Cheng Luo
National Engineering Research Center of Electronic Circuits Base Materials, Shengyi Technology Co., Ltd., Dongguan 523000, China
1 shared publication Chiji Guan
ShengYi Technology CO., LTD, National Engineering Research Center of Electronic Circuits Base Materials , 523808 Dongguan , Guangdong Province , China
1 shared publication
Latest Publications
- 27 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 37, 33-38
Adaptive Hue Threshold for Zanthoxylum Bungeanum Fruit Detection
Zanthoxylum bungeanum is very popular in China, and some automatic picking systems or robots are researched to pick the pepper fruit instead of human hands. The detection algorithm is very important for an automatic picking system. HSV color space is commonly used in color image segmentation. After evaluating the fixed threshold for pepper fruit detection, we propose a new method to get an adaptive threshold directly based on the HSV color space, called AHT, which means Adaptive Hue Threshold. The hue threshold is obtained according to the conditions, whether it is the soil, the rock, and the pepper fruit in the image. Our method works very well in typical scenarios.
- 27 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 37, 33-38
Adaptive Hue Threshold for Zanthoxylum Bungeanum Fruit Detection
Zanthoxylum bungeanum is very popular in China, and some automatic picking systems or robots are researched to pick the pepper fruit instead of human hands. The detection algorithm is very important for an automatic picking system. HSV color space is commonly used in color image segmentation. After evaluating the fixed threshold for pepper fruit detection, we propose a new method to get an adaptive threshold directly based on the HSV color space, called AHT, which means Adaptive Hue Threshold. The hue threshold is obtained according to the conditions, whether it is the soil, the rock, and the pepper fruit in the image. Our method works very well in typical scenarios.
- 26 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 735-740
Balance between Saturation and Value in Zanthoxylum Bungeanum Fruit Detection
We propose an adaptive threshold method based on the HSV color space to detect the zanthoxylum bungeanum fruit. The thresholds are obtained by keeping the sum of the Saturation and Value components unchangeable. There are many hundreds of pictures for the test dataset. Our method works very well, and the recall rate, accuracy, and false alarm are separately 100%, 100%, and 0%, improved by 5%, 9%, and 58% compared with the fixed thresholds. And to evaluate the location precision in the application of an automatic picking system, we address two metrics: the ratio of the overlap area between the detection region and the ideal region, and the location error. The ratio of the overlap area of our method is 54%, and the location error is about 11%.
- 26 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 735-740
Balance between Saturation and Value in Zanthoxylum Bungeanum Fruit Detection
We propose an adaptive threshold method based on the HSV color space to detect the zanthoxylum bungeanum fruit. The thresholds are obtained by keeping the sum of the Saturation and Value components unchangeable. There are many hundreds of pictures for the test dataset. Our method works very well, and the recall rate, accuracy, and false alarm are separately 100%, 100%, and 0%, improved by 5%, 9%, and 58% compared with the fixed thresholds. And to evaluate the location precision in the application of an automatic picking system, we address two metrics: the ratio of the overlap area between the detection region and the ideal region, and the location error. The ratio of the overlap area of our method is 54%, and the location error is about 11%.
- Open Access
- 1 September 2022
- Published by American Dairy Science Association in Journal of Dairy Science
- Vol. 105 (9) , 7242-7252
Simultaneous detection for adulterations of maltodextrin, sodium carbonate, and whey in raw milk using Raman spectroscopy and chemometrics
To achieve rapid on-site identification of raw milk adulteration and simultaneously quantify the levels of various adulterants, we combined Raman spectroscopy with chemometrics to detect 3 of the most common adulterants. Raw milk was artificially adulterated with maltodextrin (0.5-15.0%; wt/wt), sodium carbonate (10-100 mg/kg), or whey (1.0-20.0%; wt/wt). Partial least square discriminant analysis (PLS-DA) classification and a partial least square (PLS) regression model were established using Raman spectra of 144 samples, among which 108 samples were used for training and 36 were used for validation. A model with excellent performance was obtained by spectral preprocessing with first derivative, and variable selection optimization with variable importance in the projection. The classification accuracy of the PLS-DA model was 95.83% for maltodextrin, 100% for sodium carbonate, 95.84% for whey, and 92.25% for pure raw milk. The PLS model had a detection limit of 1.46% for maltodextrin, 4.38 mg/kg for sodium carbonate, and 2.64% for whey. These results suggested that Raman spectroscopy combined with PLS-DA and PLS model can rapidly and efficiently detect adulterants of maltodextrin, sodium carbonate, and whey in raw milk.
- 1 September 2022
- Published by American Dairy Science Association in Journal of Dairy Science
- Vol. 105 (9) , 7242-7252
Open AccessSimultaneous detection for adulterations of maltodextrin, sodium carbonate, and whey in raw milk using Raman spectroscopy and chemometrics
To achieve rapid on-site identification of raw milk adulteration and simultaneously quantify the levels of various adulterants, we combined Raman spectroscopy with chemometrics to detect 3 of the most common adulterants. Raw milk was artificially adulterated with maltodextrin (0.5-15.0%; wt/wt), sodium carbonate (10-100 mg/kg), or whey (1.0-20.0%; wt/wt). Partial least square discriminant analysis (PLS-DA) classification and a partial least square (PLS) regression model were established using Raman spectra of 144 samples, among which 108 samples were used for training and 36 were used for validation. A model with excellent performance was obtained by spectral preprocessing with first derivative, and variable selection optimization with variable importance in the projection. The classification accuracy of the PLS-DA model was 95.83% for maltodextrin, 100% for sodium carbonate, 95.84% for whey, and 92.25% for pure raw milk. The PLS model had a detection limit of 1.46% for maltodextrin, 4.38 mg/kg for sodium carbonate, and 2.64% for whey. These results suggested that Raman spectroscopy combined with PLS-DA and PLS model can rapidly and efficiently detect adulterants of maltodextrin, sodium carbonate, and whey in raw milk.
- 20 July 2022
- Published by SAGE Publications in Journal of Near Infrared Spectroscopy
- Vol. 30 (4) , 227-233
Determination of ash content in silicon dioxide filled epoxy-phenolic prepreg using near infrared spectroscopy
This paper presents an application of near infrared spectroscopy associated with partial least squares regression calibration, for ash content analysis of prepreg in the manufacturing progress of copper clad laminate for printed circuited boards. The performance of the model was assessed by cross validation and external validation. The correlation coefficient and the root mean squared error of calibration and validation were 0.99, 0.25% and 0.98, 0.34%, and the measurement process was accomplished in less than 2 min compared to over 60 min for traditional thermo gravimetric analyzsis. The paired t-test results revealed that there was no significant difference between the two methods.
- 20 July 2022
- Published by SAGE Publications in Journal of Near Infrared Spectroscopy
- Vol. 30 (4) , 227-233
Determination of ash content in silicon dioxide filled epoxy-phenolic prepreg using near infrared spectroscopy
This paper presents an application of near infrared spectroscopy associated with partial least squares regression calibration, for ash content analysis of prepreg in the manufacturing progress of copper clad laminate for printed circuited boards. The performance of the model was assessed by cross validation and external validation. The correlation coefficient and the root mean squared error of calibration and validation were 0.99, 0.25% and 0.98, 0.34%, and the measurement process was accomplished in less than 2 min compared to over 60 min for traditional thermo gravimetric analyzsis. The paired t-test results revealed that there was no significant difference between the two methods.
- Open Access
Effects of Peroxide Initiator on the Structure and Properties of Ultralow Loss Thermosetting Polyphenylene Oxide-Based Composite
Although thermosetting polyphenylene oxide- (PPO) based composites with excellent dielectric properties have been widely accepted as superior resin matrices of high-performance copper clad laminate (CCL) for 5G network devices, there has been limited information regarding the composition–process–structure–property relationships of the systems. In this work, the effects of peroxide initiator concentration on the structure and dielectric properties of a free radical cured ultralow loss PPO/Triallyl isocyanate (TAIC) composite system were studied. As expected, the glass transition temperature (Tg) and storage modulus increased with the advancing of crosslinking, whereas the dielectric loss showed an “abnormal” rise with the increase in crosslink density. Extensive studies were carried out by varying the initiator contents and characterizing the structure with spectroscopy, thermal analysis, and positron annihilation lifetime spectrum (PALS) techniques. The results show that the competition of polarity, crosslink density, free volume, and free TAIC are the key factors determining the dielectric properties of the composites.
Open AccessEffects of Peroxide Initiator on the Structure and Properties of Ultralow Loss Thermosetting Polyphenylene Oxide-Based Composite
Although thermosetting polyphenylene oxide- (PPO) based composites with excellent dielectric properties have been widely accepted as superior resin matrices of high-performance copper clad laminate (CCL) for 5G network devices, there has been limited information regarding the composition–process–structure–property relationships of the systems. In this work, the effects of peroxide initiator concentration on the structure and dielectric properties of a free radical cured ultralow loss PPO/Triallyl isocyanate (TAIC) composite system were studied. As expected, the glass transition temperature (Tg) and storage modulus increased with the advancing of crosslinking, whereas the dielectric loss showed an “abnormal” rise with the increase in crosslink density. Extensive studies were carried out by varying the initiator contents and characterizing the structure with spectroscopy, thermal analysis, and positron annihilation lifetime spectrum (PALS) techniques. The results show that the competition of polarity, crosslink density, free volume, and free TAIC are the key factors determining the dielectric properties of the composites.
- Open Access
- 1 January 2022
- Published by Walter de Gruyter GmbH in Reviews in Analytical Chemistry
- Vol. 41 (1) , 74-82
Analysis of initiator content of prepreg by near-infrared spectroscopy
During the production process of some copper clad laminate (CCL), the content of 3,3,5,7,7-pentamethyl-1,2,4-trioxepane in prepreg can affect the cross-linking and curing degree of resin directly, and thereby affect the properties of CCL. In this article, near-infrared (NIR) spectroscopy combined with partial least square regression using high performance liquid chromatography as a reference method were used for the determination of 3,3,5,7,7-pentamethyl-1,2,4-trioxepane in the CCL production progress. 160 spectra of prepreg samples randomly formed the calibration set, and 50 spectra of prepreg samples formed the validation set. The value of the root mean square error of calibration (w/w) and root mean square error of prediction (w/w) were 0.011% and 0.013% for 3,3,5,7,7-pentamethyl-1,2,4-trioxepane content (%, w/w), and the calculation and validation of the regression equation resulted in high correlation coefficients of 0.99 and 0.98, respectively. The scatter plot value of calibration set which was obtained from the root mean square error of cross-validation (w/w) was 0.015%, and the regression equation resulted in high correlation coefficient of 0.98. The results of the paired t-test revealed that there was no significant difference between NIR and HPLC method. Thus, the results obtained in this study reflect that NIR could be used as a rapid, accurate, and simultaneous technique to determine 3,3,5,7,7-pentamethyl-1,2,4-trioxepane content of prepreg in the production process.
- 1 January 2022
- Published by Walter de Gruyter GmbH in Reviews in Analytical Chemistry
- Vol. 41 (1) , 74-82
Open AccessAnalysis of initiator content of prepreg by near-infrared spectroscopy
During the production process of some copper clad laminate (CCL), the content of 3,3,5,7,7-pentamethyl-1,2,4-trioxepane in prepreg can affect the cross-linking and curing degree of resin directly, and thereby affect the properties of CCL. In this article, near-infrared (NIR) spectroscopy combined with partial least square regression using high performance liquid chromatography as a reference method were used for the determination of 3,3,5,7,7-pentamethyl-1,2,4-trioxepane in the CCL production progress. 160 spectra of prepreg samples randomly formed the calibration set, and 50 spectra of prepreg samples formed the validation set. The value of the root mean square error of calibration (w/w) and root mean square error of prediction (w/w) were 0.011% and 0.013% for 3,3,5,7,7-pentamethyl-1,2,4-trioxepane content (%, w/w), and the calculation and validation of the regression equation resulted in high correlation coefficients of 0.99 and 0.98, respectively. The scatter plot value of calibration set which was obtained from the root mean square error of cross-validation (w/w) was 0.015%, and the regression equation resulted in high correlation coefficient of 0.98. The results of the paired t-test revealed that there was no significant difference between NIR and HPLC method. Thus, the results obtained in this study reflect that NIR could be used as a rapid, accurate, and simultaneous technique to determine 3,3,5,7,7-pentamethyl-1,2,4-trioxepane content of prepreg in the production process.
- 6 August 2021
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 57 (70) , 8810-8813
Gas-cycle-assisted headspace solid-phase microextraction coupled with gas chromatography for rapid analysis of organic pollutants
Herein, a new gas-cycle-assisted (GCA) headspace solid-phase microextraction (HS-SPME) device was designed to rapidly extract organic pollutants with high Kow and boiling points, which have difficulty in volatilization from matrix to headspace. Organic pollutants, including three polycyclic aromatic hydrocarbons (PAHs), four polychlorinated biphenyls (PCBs), and five phthalate esters (PAEs), were selected to evaluate the performance of GCA HS-SPME. Compared with conventional HS-SPME, the equilibrium times of GCA HS-SPME for extraction of PAHs, PCBs, and PAEs were greatly shortened from 70–90 to 5–11 min. Moreover, the limits of detection for analysis of PAHs were achieved at pg mL−1 level by GCA HS-SPME coupled with gas chromatography-flame ionization detection.
- 6 August 2021
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 57 (70) , 8810-8813
Gas-cycle-assisted headspace solid-phase microextraction coupled with gas chromatography for rapid analysis of organic pollutants
Herein, a new gas-cycle-assisted (GCA) headspace solid-phase microextraction (HS-SPME) device was designed to rapidly extract organic pollutants with high Kow and boiling points, which have difficulty in volatilization from matrix to headspace. Organic pollutants, including three polycyclic aromatic hydrocarbons (PAHs), four polychlorinated biphenyls (PCBs), and five phthalate esters (PAEs), were selected to evaluate the performance of GCA HS-SPME. Compared with conventional HS-SPME, the equilibrium times of GCA HS-SPME for extraction of PAHs, PCBs, and PAEs were greatly shortened from 70–90 to 5–11 min. Moreover, the limits of detection for analysis of PAHs were achieved at pg mL−1 level by GCA HS-SPME coupled with gas chromatography-flame ionization detection.
- 9 October 2020
- Published by SAGE Publications in Journal of Near Infrared Spectroscopy
- Vol. 29 (1) , 5-10
Determination of gel time of prepreg in copper clad laminate industry by near infrared spectroscopy
Gel time of prepreg is an important quality determinant in the manufacturing process of copper clad laminate (CCL). Prepreg consists of a glass fiber reinforcement impregnated to a predetermined level with a resin matrix. In this work, near infrared spectroscopy associated with partial least squares (PLS) regression has been applied to analyse the gel time of prepreg samples in the manufacturing process. A total of 250 prepreg samples were randomly divided into a calibration set and a validation prediction set with a ratio of 4:1. The values of root mean square error of leave-one-out cross-validation (RMSECV) and the coefficient of determination (R2) of the calibration model was 2.95 s and 0.92 respectively, with eight PLS factors used. The results of the paired t-test revealed that there was no significant difference between the NIR method and the reference method. The analytical result showed that, NIR spectroscopy was a rapid, nondestructive, and accurate method for real-time prediction of prepreg quality in the CCL manufacturing process.
- 9 October 2020
- Published by SAGE Publications in Journal of Near Infrared Spectroscopy
- Vol. 29 (1) , 5-10
Determination of gel time of prepreg in copper clad laminate industry by near infrared spectroscopy
Gel time of prepreg is an important quality determinant in the manufacturing process of copper clad laminate (CCL). Prepreg consists of a glass fiber reinforcement impregnated to a predetermined level with a resin matrix. In this work, near infrared spectroscopy associated with partial least squares (PLS) regression has been applied to analyse the gel time of prepreg samples in the manufacturing process. A total of 250 prepreg samples were randomly divided into a calibration set and a validation prediction set with a ratio of 4:1. The values of root mean square error of leave-one-out cross-validation (RMSECV) and the coefficient of determination (R2) of the calibration model was 2.95 s and 0.92 respectively, with eight PLS factors used. The results of the paired t-test revealed that there was no significant difference between the NIR method and the reference method. The analytical result showed that, NIR spectroscopy was a rapid, nondestructive, and accurate method for real-time prediction of prepreg quality in the CCL manufacturing process.