Marwa Wahsh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Marwa Wahsh has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Ahmad Aboelfadl
Faculty of Dentistry Ain Shams University, Cairo Cairo Governorate Egypt
3 shared publications - Fatma Adel Mohamed Ahmed
Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
3 shared publications - Hoda M. Abdel Sadek
Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
3 shared publications - Amr El-Etreby
Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
2 shared publications - Manar Ahmed El-Mahdy
Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
2 shared publications - Tarek Salah Morsi
Department of Fixed Prosthodontics, Ain-Shams University, Egypt
2 shared publications
Latest Publications
- Open Access
- 27 March 2026
- Published by Springer Nature in BMC Oral Health
- Vol. 26  (1)
Fracture strength and failure patterns of different restoration approaches in endodontically treated maxillary premolars: an in vitro study with fractographic analysis
Background: The restoration of endodontically treated premolars has been a controversial topic. Whether a post or a more conservative option should be used remains inconclusive. The present in vitro study aimed to evaluate the fracture strength and failure pattern of different partial coverage restoration approaches for endodontically treated upper premolars in comparison to the post, core and crown approach. Methods: Thirty-five maxillary premolars were endodontically treated and assigned to five groups ( n = 7): endocrown (E), endocrown with buccal veneer (EB), overlay (O), overlay with buccal veneer (OB), and post, core, and crown (P). All restorations were fabricated from lithium disilicate ceramics and subjected to vertical static loading until failure. Fracture strength was recorded, and failure patterns were examined using a stereomicroscope and scanning electron microscopy. Data were analyzed with Welch one-way ANOVA and Games–Howell post hoc test (α = 0.05). Results: Significant differences were found among groups (p < 0.001) with a large effect size (partial eta squared = 0.83 (95% CI; 0.59 to 0.91). The highest mean fracture strength was observed in group P (1676.29 ± 191.25 N), followed by OB (1475.00 ± 198.72 N), E (1374.71 ± 371.91 N), EB (1047.41 ± 163.90 N), and O (987.99 ± 125.01 N). Groups P and OB demonstrated significantly higher strength than EB and O. Group P exhibited only repairable restoration fractures, whereas the other groups predominantly showed catastrophic failures. Conclusions: Within the limitations of this in vitro study, post, core, and crown restorations provided superior fracture strength and the most favorable failure patterns under static axial loading. While overlays with buccal veneers demonstrated promising mechanical resistance thresholds, their clinical application should be considered with caution. These designs may serve as a potential conservative alternative, although further research involving dynamic fatigue and oblique loading is required to confirm their long-term clinical durability in the complex oral environment. Clinical relevance: The findings of this in-vitro study provide insight into the fracture strength and failure tendencies of different restorative approaches for endodontically treated maxillary premolars. While post, core, and crown restorations demonstrated high load-bearing capacity and predominantly favourable failure patterns, overlay designs with a buccal veneer showed comparable strength but a greater tendency toward catastrophic fractures. These observations highlight a potential balance between structural preservation and failure reparability. Given that static axial loading was used, direct clinical interpretation should be approached cautiously. Treatment planning should integrate these biomechanical considerations with patient-specific factors, functional demands, and clinical judgment when selecting restorative approaches.
- 27 March 2026
- Published by Springer Nature in BMC Oral Health
- Vol. 26  (1)
Open AccessFracture strength and failure patterns of different restoration approaches in endodontically treated maxillary premolars: an in vitro study with fractographic analysis
Background: The restoration of endodontically treated premolars has been a controversial topic. Whether a post or a more conservative option should be used remains inconclusive. The present in vitro study aimed to evaluate the fracture strength and failure pattern of different partial coverage restoration approaches for endodontically treated upper premolars in comparison to the post, core and crown approach. Methods: Thirty-five maxillary premolars were endodontically treated and assigned to five groups ( n = 7): endocrown (E), endocrown with buccal veneer (EB), overlay (O), overlay with buccal veneer (OB), and post, core, and crown (P). All restorations were fabricated from lithium disilicate ceramics and subjected to vertical static loading until failure. Fracture strength was recorded, and failure patterns were examined using a stereomicroscope and scanning electron microscopy. Data were analyzed with Welch one-way ANOVA and Games–Howell post hoc test (α = 0.05). Results: Significant differences were found among groups (p < 0.001) with a large effect size (partial eta squared = 0.83 (95% CI; 0.59 to 0.91). The highest mean fracture strength was observed in group P (1676.29 ± 191.25 N), followed by OB (1475.00 ± 198.72 N), E (1374.71 ± 371.91 N), EB (1047.41 ± 163.90 N), and O (987.99 ± 125.01 N). Groups P and OB demonstrated significantly higher strength than EB and O. Group P exhibited only repairable restoration fractures, whereas the other groups predominantly showed catastrophic failures. Conclusions: Within the limitations of this in vitro study, post, core, and crown restorations provided superior fracture strength and the most favorable failure patterns under static axial loading. While overlays with buccal veneers demonstrated promising mechanical resistance thresholds, their clinical application should be considered with caution. These designs may serve as a potential conservative alternative, although further research involving dynamic fatigue and oblique loading is required to confirm their long-term clinical durability in the complex oral environment. Clinical relevance: The findings of this in-vitro study provide insight into the fracture strength and failure tendencies of different restorative approaches for endodontically treated maxillary premolars. While post, core, and crown restorations demonstrated high load-bearing capacity and predominantly favourable failure patterns, overlay designs with a buccal veneer showed comparable strength but a greater tendency toward catastrophic fractures. These observations highlight a potential balance between structural preservation and failure reparability. Given that static axial loading was used, direct clinical interpretation should be approached cautiously. Treatment planning should integrate these biomechanical considerations with patient-specific factors, functional demands, and clinical judgment when selecting restorative approaches.
- Open Access
- 22 April 2025
- Published by Wroclaw Medical University in Dental and Medical Problems
- No. 3,p. 961-967
Effect of the contamination and cleaning methods on the tensile bond strength of the polyetheretherketone restorative material cemented with dual-cure resin cement
These days, computer-aided design/computer-aided manufacturing (CAD/CAM) resinbased materials are being used daily in clinical practice for restorations in prosthetic dentistry. In comparison with ceramic materials, they are characterized by better stress distribution and decreased abrasion of the enamel of the opposing teeth. Consequently, they have been applied as alternative materials to ceramics in various dental restorations. The contamination of the indirect restorative material, which occurs at the clinical and dental laboratory stages, might deteriorate the bonding strength. The ideal surface treatment of the novel polyetheretherketone (PEEK) material for decontamination is yet unknown. The present study was conducted to evaluate the tensile bond strength (TBS) between PEEK and dual-cure self-adhesive resin cement, and determine the effect of contaminants, like temporary cement, artificial saliva and a fit checker, as well as the cleaning methods, like ultrasonic cleaning, phosphoric acid etching and universal cleaning paste (Ivoclean), on the bond. Eighty PEEK disks were milled, having the final dimensions of 12 mm × 4 mm. The specimens were air-abraded with 50-micrometer aluminum oxide particles at a pressure of 2.8 bar for 15 s at a fixed distance of 10 mm, and then divided into 4 groups according to the contaminant used: temporary cement; artificial saliva; a fit checker; and a control group with no contamination. Furthermore, the first 3 groups were subsequently subdivided into 3 subgroups each according to the cleaning method applied: ultrasonic cleaning; phosphoric acid etching; and universal cleaning paste Ivoclean. The bonding of the specimens was done using dual-cure self-adhesive resin cement. The TBS of the different groups and subgroups was then measured at a crosshead speed of 2 mm/min in a universal testing machine (UTM), using a special test configuration. There was a significant interaction between both tested variables (the contamination and cleaning methods) (p < 0.001). The samples contaminated with artificial saliva showed a significantly higher TBS value than the samples subjected to other contaminants (p = 0.005). For the samples contaminated with temporary cement and a fit checker, there were significant differences between the different cleaning methods, with ultrasonic cleaning providing the highest TBS values, followed by phosphoric acid etching, and finally Ivoclean (p < 0.001). Under the conditions of the present study, temporary cement and a fit checker adversely affected the TBS of PEEK, and ultrasonic cleaning was most effective for decontamination.
- 22 April 2025
- Published by Wroclaw Medical University in Dental and Medical Problems
- No. 3,p. 961-967
Open AccessEffect of the contamination and cleaning methods on the tensile bond strength of the polyetheretherketone restorative material cemented with dual-cure resin cement
These days, computer-aided design/computer-aided manufacturing (CAD/CAM) resinbased materials are being used daily in clinical practice for restorations in prosthetic dentistry. In comparison with ceramic materials, they are characterized by better stress distribution and decreased abrasion of the enamel of the opposing teeth. Consequently, they have been applied as alternative materials to ceramics in various dental restorations. The contamination of the indirect restorative material, which occurs at the clinical and dental laboratory stages, might deteriorate the bonding strength. The ideal surface treatment of the novel polyetheretherketone (PEEK) material for decontamination is yet unknown. The present study was conducted to evaluate the tensile bond strength (TBS) between PEEK and dual-cure self-adhesive resin cement, and determine the effect of contaminants, like temporary cement, artificial saliva and a fit checker, as well as the cleaning methods, like ultrasonic cleaning, phosphoric acid etching and universal cleaning paste (Ivoclean), on the bond. Eighty PEEK disks were milled, having the final dimensions of 12 mm × 4 mm. The specimens were air-abraded with 50-micrometer aluminum oxide particles at a pressure of 2.8 bar for 15 s at a fixed distance of 10 mm, and then divided into 4 groups according to the contaminant used: temporary cement; artificial saliva; a fit checker; and a control group with no contamination. Furthermore, the first 3 groups were subsequently subdivided into 3 subgroups each according to the cleaning method applied: ultrasonic cleaning; phosphoric acid etching; and universal cleaning paste Ivoclean. The bonding of the specimens was done using dual-cure self-adhesive resin cement. The TBS of the different groups and subgroups was then measured at a crosshead speed of 2 mm/min in a universal testing machine (UTM), using a special test configuration. There was a significant interaction between both tested variables (the contamination and cleaning methods) (p < 0.001). The samples contaminated with artificial saliva showed a significantly higher TBS value than the samples subjected to other contaminants (p = 0.005). For the samples contaminated with temporary cement and a fit checker, there were significant differences between the different cleaning methods, with ultrasonic cleaning providing the highest TBS values, followed by phosphoric acid etching, and finally Ivoclean (p < 0.001). Under the conditions of the present study, temporary cement and a fit checker adversely affected the TBS of PEEK, and ultrasonic cleaning was most effective for decontamination.
- Open Access
- 30 September 2023
- Published by Wroclaw Medical University in Dental and Medical Problems
- Vol. 60  (3) , 497-503
Strain gauge analysis and fracture resistance of implant-supported PEKK hybrid abutments restored with two crown materials: An in vitro study
Polyetherketoneketone (PEKK) was recently introduced as an alternative to titanium and ceramic implant abutments due to its apparent ability to dissipate excessive strain around dental implants. However, the biomechanical behaviors of implant abutment crown systems may change depending on the crown and abutment material combinations used. This study aimed to assess how the crown material affects strain generation and fracture resistance of PEKK hybrid abutment crowns. Sixteen dummy implants (Ø 3.7 x 11 mm), simulating maxillary first premolars, were restored with 16 milled PEKK hybrid abutments and randomly categorized into two groups according to the crown material (n = 8): Group C, milled composite crowns cemented on PEKK hybrid abutments; and Group Z, ultra-translucent zirconia crowns cemented on PEKK hybrid abutments. Before thermocycling, a cyanoacrylate-base adhesive was used to position two strain gauges on buccal and lingual crestal bone surfaces, and a vertical load (100 N) was applied to the central fossa to record the strain generated. Then, all samples were thermocycled between 5°C and 55°C before being loaded to fracture on a universal testing machine. Modes of failure were observed under an optical microscope, and representative samples were examined using a scanning electron microscope. Independent t-tests were used for intergroup comparisons. The significance level was set at (p < 0.05) for all tests.. The results showed a significant difference between both groups. The zirconia group recorded significantly higher strain and fracture resistance values than the composite group (p < 0.001). There was a positive correlation between the strain developed in peri-implant crestal bone and fracture resistance of the abutment crown complex. Strains developed in both groups were within the acceptable clinical range. The crown material substantially impacted the strain and fracture of the PEKK hybrid abutment crown system.
- 30 September 2023
- Published by Wroclaw Medical University in Dental and Medical Problems
- Vol. 60  (3) , 497-503
Open AccessStrain gauge analysis and fracture resistance of implant-supported PEKK hybrid abutments restored with two crown materials: An in vitro study
Polyetherketoneketone (PEKK) was recently introduced as an alternative to titanium and ceramic implant abutments due to its apparent ability to dissipate excessive strain around dental implants. However, the biomechanical behaviors of implant abutment crown systems may change depending on the crown and abutment material combinations used. This study aimed to assess how the crown material affects strain generation and fracture resistance of PEKK hybrid abutment crowns. Sixteen dummy implants (Ø 3.7 x 11 mm), simulating maxillary first premolars, were restored with 16 milled PEKK hybrid abutments and randomly categorized into two groups according to the crown material (n = 8): Group C, milled composite crowns cemented on PEKK hybrid abutments; and Group Z, ultra-translucent zirconia crowns cemented on PEKK hybrid abutments. Before thermocycling, a cyanoacrylate-base adhesive was used to position two strain gauges on buccal and lingual crestal bone surfaces, and a vertical load (100 N) was applied to the central fossa to record the strain generated. Then, all samples were thermocycled between 5°C and 55°C before being loaded to fracture on a universal testing machine. Modes of failure were observed under an optical microscope, and representative samples were examined using a scanning electron microscope. Independent t-tests were used for intergroup comparisons. The significance level was set at (p < 0.05) for all tests.. The results showed a significant difference between both groups. The zirconia group recorded significantly higher strain and fracture resistance values than the composite group (p < 0.001). There was a positive correlation between the strain developed in peri-implant crestal bone and fracture resistance of the abutment crown complex. Strains developed in both groups were within the acceptable clinical range. The crown material substantially impacted the strain and fracture of the PEKK hybrid abutment crown system.
- Open Access
- 1 January 2023
- Published by Egyptian Knowledge Bank in Egyptian Dental Journal
- Vol. 69  (1) , 683-695
Surface Roughness and Color stability of Provisional Restorative Materials Fabricated Using Different Methods After Immersion in Various Storage Media
Objectives: To investigate and compare the color stability and surface roughness of provisional restorative materials fabricated by 3D printing, milling and conventional techniques after immersion in different storage media. Materials and methods: The 84-disc specimens were fabricated and divided into 3 groups according to the technique of fabrication (n=28), group C: Conventional techniques, group M: milled technique, group P: 3d printed technique. Each group was divided into 4 subgroups according to storage media (n=7), Subgroup D: distilled water, subgroup C: coffee solution, subgroup Co: cola, and subgroup O: orange juice. Baseline color was measured using spectrophotometer then measured after 2 and 4 weeks of immersion in different storage media. Color change (ΔE) was assessed using of the CIE L*a*b* system. Surface roughness was also measured using profilometer for all specimens before and after immersion in staining solutions. The data was then collected and statistically analyzed using two-way ANOVA. The significance level was set at p < 0.05 within all tests. Results: Two-way ANOVA showed that the fabrication technique and interaction between variables had a significant effect on surface roughness. There was a significant interaction between fabrication method, solution type and storage time on color stability. Conclusions: The surface roughness of 3D printed materials was higher than milled and conventional groups. 3D printed and CAD-CAM milled materials had better color stability compared to conventional group.
- 1 January 2023
- Published by Egyptian Knowledge Bank in Egyptian Dental Journal
- Vol. 69  (1) , 683-695
Open AccessSurface Roughness and Color stability of Provisional Restorative Materials Fabricated Using Different Methods After Immersion in Various Storage Media
Objectives: To investigate and compare the color stability and surface roughness of provisional restorative materials fabricated by 3D printing, milling and conventional techniques after immersion in different storage media. Materials and methods: The 84-disc specimens were fabricated and divided into 3 groups according to the technique of fabrication (n=28), group C: Conventional techniques, group M: milled technique, group P: 3d printed technique. Each group was divided into 4 subgroups according to storage media (n=7), Subgroup D: distilled water, subgroup C: coffee solution, subgroup Co: cola, and subgroup O: orange juice. Baseline color was measured using spectrophotometer then measured after 2 and 4 weeks of immersion in different storage media. Color change (ΔE) was assessed using of the CIE L*a*b* system. Surface roughness was also measured using profilometer for all specimens before and after immersion in staining solutions. The data was then collected and statistically analyzed using two-way ANOVA. The significance level was set at p < 0.05 within all tests. Results: Two-way ANOVA showed that the fabrication technique and interaction between variables had a significant effect on surface roughness. There was a significant interaction between fabrication method, solution type and storage time on color stability. Conclusions: The surface roughness of 3D printed materials was higher than milled and conventional groups. 3D printed and CAD-CAM milled materials had better color stability compared to conventional group.
- Open Access
- 1 January 2023
- Published by Egyptian Knowledge Bank in Egyptian Dental Journal
- Vol. 69  (1) , 497-504
The Effect of Surface Grinding and Finishing on the Surface Roughness And Flexural Strength of Cubic Zirconia
Statement of problem: The translucency of cubic zirconia is improved on the expense of its strength. The effect of grinding and finishing on its mechanical properties is still unclear. Purpose: The aim of this study was to evaluate the influence of glazing and polishing protocols on the surface roughness and flexural strength of monolithic cubic zirconia after dry and wet grinding. Materials and methods: Super translucent multilayer zirconia (STML) disks were cut, sintered, and glazed according to the manufacturer’s recommendations. Samples were randomly divided into three groups according to surface grinding: Group (C): control (no grinding-as glazed), Group (D)grinding under dry condition and group (W) grinding under wet condition. Each group of (D)and(W) was subdivided into two subgroups according to surface finishing whether glazing or polishing. The roughness average (Ra) was measured using contact profilometer. Biaxial flexural strength test was done using a universal testing machine. Statistical analysis was performed. Results: The glazing showed a statistically significantly higher mean Ra (P<0.05) than polishing whether after wet or dry grinding. The dry ground groups showed a statistically significantly higher mean Ra (P<0.05) than wet ground groups. The glazing showed a statistically significantly lower mean biaxial flexural strength than Polishing (P0.05) after wet grinding. Conclusion: Adequate polishing can produce a smoother surface than reglazing. Dry grinding can increase the surface roughness to a degree that can affect the flexural strength of STML zirconia.
- 1 January 2023
- Published by Egyptian Knowledge Bank in Egyptian Dental Journal
- Vol. 69  (1) , 497-504
Open AccessThe Effect of Surface Grinding and Finishing on the Surface Roughness And Flexural Strength of Cubic Zirconia
Statement of problem: The translucency of cubic zirconia is improved on the expense of its strength. The effect of grinding and finishing on its mechanical properties is still unclear. Purpose: The aim of this study was to evaluate the influence of glazing and polishing protocols on the surface roughness and flexural strength of monolithic cubic zirconia after dry and wet grinding. Materials and methods: Super translucent multilayer zirconia (STML) disks were cut, sintered, and glazed according to the manufacturer’s recommendations. Samples were randomly divided into three groups according to surface grinding: Group (C): control (no grinding-as glazed), Group (D)grinding under dry condition and group (W) grinding under wet condition. Each group of (D)and(W) was subdivided into two subgroups according to surface finishing whether glazing or polishing. The roughness average (Ra) was measured using contact profilometer. Biaxial flexural strength test was done using a universal testing machine. Statistical analysis was performed. Results: The glazing showed a statistically significantly higher mean Ra (P<0.05) than polishing whether after wet or dry grinding. The dry ground groups showed a statistically significantly higher mean Ra (P<0.05) than wet ground groups. The glazing showed a statistically significantly lower mean biaxial flexural strength than Polishing (P0.05) after wet grinding. Conclusion: Adequate polishing can produce a smoother surface than reglazing. Dry grinding can increase the surface roughness to a degree that can affect the flexural strength of STML zirconia.
- Open Access
- 1 October 2022
- Published by Egyptian Knowledge Bank in Egyptian Dental Journal
- Vol. 68  (4) , 3553-3558
Effect of different ceramic materials on debonding time with dentin using Er, Cr:YSGG laser
Objectives: Comparing debonding time of three different ceramic materials lithium disilicate, ultra-translucent zirconia and hybrid-ceramic with dentin using Er, Cr:YSGG laser application. Materials and methods: Thirty recently extracted human mandibular molars were selected for study. They were fixed in acrylic resin blocks and their buccal surfaces were ground to expose dentin to provide flat surface for bonding then stored in distilled water at room temperature. Three different ceramic materials used in this study, lithium disilicate glass ceramics, hybrid-ceramic, ultra-Translucent Zirconia. A total of thirty square shaped Samples 4x4mm and 1mm thickness resembling crowns prepared from CAD/CAM (computer aided design/computer aided manufacture) ceramic blocks of these ceramic materials, 10 samples for each material. Samples bonded to dentin using dual cure self-adhesive resin cement (TOTALCEM ITENA, France). Laser debonding of ceramic samples of all three materials using Er,Cr:YSGG laser (Waterlase by Biolase). Data were parametric and showed variance homogeneity, so they were analyzed using independent t-test. The significance level was set at p < 0.05 within all tests. Results: Results showed that there was a significant difference between different groups (p < 0.001). The highest value was found in Vita Enamic samples (160.00±22.91) followed by BruxZir (21.57±5.26), while the lowest value was found in Emax samples (7.00±1.29). Conclusions: The Ultra translucent zirconia and Lithium disilicate were deboned from dentin using Er,Cr:YSGG laser. Using laser for debonding Ultra translucent Zirconia consumses higher time than for Lithium disilicate. Destruction of hybrid ceramics when it was exposed to Er,Cr:YSGG laser to debond it from dentin.
- 1 October 2022
- Published by Egyptian Knowledge Bank in Egyptian Dental Journal
- Vol. 68  (4) , 3553-3558
Open AccessEffect of different ceramic materials on debonding time with dentin using Er, Cr:YSGG laser
Objectives: Comparing debonding time of three different ceramic materials lithium disilicate, ultra-translucent zirconia and hybrid-ceramic with dentin using Er, Cr:YSGG laser application. Materials and methods: Thirty recently extracted human mandibular molars were selected for study. They were fixed in acrylic resin blocks and their buccal surfaces were ground to expose dentin to provide flat surface for bonding then stored in distilled water at room temperature. Three different ceramic materials used in this study, lithium disilicate glass ceramics, hybrid-ceramic, ultra-Translucent Zirconia. A total of thirty square shaped Samples 4x4mm and 1mm thickness resembling crowns prepared from CAD/CAM (computer aided design/computer aided manufacture) ceramic blocks of these ceramic materials, 10 samples for each material. Samples bonded to dentin using dual cure self-adhesive resin cement (TOTALCEM ITENA, France). Laser debonding of ceramic samples of all three materials using Er,Cr:YSGG laser (Waterlase by Biolase). Data were parametric and showed variance homogeneity, so they were analyzed using independent t-test. The significance level was set at p < 0.05 within all tests. Results: Results showed that there was a significant difference between different groups (p < 0.001). The highest value was found in Vita Enamic samples (160.00±22.91) followed by BruxZir (21.57±5.26), while the lowest value was found in Emax samples (7.00±1.29). Conclusions: The Ultra translucent zirconia and Lithium disilicate were deboned from dentin using Er,Cr:YSGG laser. Using laser for debonding Ultra translucent Zirconia consumses higher time than for Lithium disilicate. Destruction of hybrid ceramics when it was exposed to Er,Cr:YSGG laser to debond it from dentin.
- 5 February 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 127  (4) , 599.e1-599.e7
Effect of combining different surface treatments on the surface characteristics of polyetheretherketone-based core materials and shear bond strength to a veneering composite resin
- 5 February 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 127  (4) , 599.e1-599.e7
Effect of combining different surface treatments on the surface characteristics of polyetheretherketone-based core materials and shear bond strength to a veneering composite resin
- Open Access
- 1 October 2021
- Published by Editora Cubo in Brazilian Dental Science
- Vol. 24  (4)
Resin Nano-Ceramic Material Surface Roughness, Color Stability, and Bacterial Adhesion Evaluation After Different Scaling Methods
Objectives: The study evaluated in vitro the changes in roughness, color stability, and bacterial count of a CAD/CAM Resin Nano-Ceramic material surface treated by various scaling procedures. Material and Methods: 70 disks (5mm diameter, 0.5 mm thickness) of Resin Nano-Ceramic (Lava â„¢Ultimate, 3M, ESPE) material were cemented in standardized cavities prepared in bovine teeth. A custom-made scaling apparatus of a double pan balance was used for different scaling methods, simulating standard clinical conditions. The specimens were assigned to three main groups: no scaling(C), ultrasonic scaling (U), and manual scaling (M). Each group was then divided into three subgroups according to scaling tip material; stainless steel tip (St), plastic tip (P), and titanium tip (Ti). The surface texture was analyzed quantitatively and qualitatively with a tactile profilometer and atomic force microscopy. A spectrophotometer was used for color measurement. Streptococcus mutans were counted in a colony counter. All the data were tabulated and statistically analyzed. Results: Two-way ANOVA was used to study the effect while One-way ANOVA was performed to compare between study groups. The significance level was set at p 0.05. The ultrasonic titanium tip(UTi) revealed the significant highest mean value of alterations (p < 0.001). The integrity of the material surface was altered in the form of deep scratches on the ultrasonically scaled surfaces and numerous smaller scratches on the hand-scaled surfaces. Conclusion: The plastic instrument would appear to be the instrument of choice during a routine maintenance procedure for Resin Nano-Ceramic materials. Keywords Bacterial biofilm; Dental ceramics; Color stability; Scaling; Surface roughness.
- 1 October 2021
- Published by Editora Cubo in Brazilian Dental Science
- Vol. 24  (4)
Open AccessResin Nano-Ceramic Material Surface Roughness, Color Stability, and Bacterial Adhesion Evaluation After Different Scaling Methods
Objectives: The study evaluated in vitro the changes in roughness, color stability, and bacterial count of a CAD/CAM Resin Nano-Ceramic material surface treated by various scaling procedures. Material and Methods: 70 disks (5mm diameter, 0.5 mm thickness) of Resin Nano-Ceramic (Lava â„¢Ultimate, 3M, ESPE) material were cemented in standardized cavities prepared in bovine teeth. A custom-made scaling apparatus of a double pan balance was used for different scaling methods, simulating standard clinical conditions. The specimens were assigned to three main groups: no scaling(C), ultrasonic scaling (U), and manual scaling (M). Each group was then divided into three subgroups according to scaling tip material; stainless steel tip (St), plastic tip (P), and titanium tip (Ti). The surface texture was analyzed quantitatively and qualitatively with a tactile profilometer and atomic force microscopy. A spectrophotometer was used for color measurement. Streptococcus mutans were counted in a colony counter. All the data were tabulated and statistically analyzed. Results: Two-way ANOVA was used to study the effect while One-way ANOVA was performed to compare between study groups. The significance level was set at p 0.05. The ultrasonic titanium tip(UTi) revealed the significant highest mean value of alterations (p < 0.001). The integrity of the material surface was altered in the form of deep scratches on the ultrasonically scaled surfaces and numerous smaller scratches on the hand-scaled surfaces. Conclusion: The plastic instrument would appear to be the instrument of choice during a routine maintenance procedure for Resin Nano-Ceramic materials. Keywords Bacterial biofilm; Dental ceramics; Color stability; Scaling; Surface roughness.
- 1 July 2021
- Published by Egyptian Knowledge Bank in Egyptian Dental Journal
- Vol. 67  (3) , 2509-2517
The Effect of Ceramic Material and Preparation Design on the Fracture Resistance of Onlay Restorations
Objectives: Evaluating the fracture resistance and failure mode of human maxillary premolars restored with two ceramic onlay materials prepared with two preparation designs. Materials and methods: A total of 40 extracted, human maxillary premolars were selected and divided into two groups according to preparation design; Group A: MOD cavity with anatomical reduction of functional cusp and Group F: MOD cavity with flat reduction of the functional cusp. Each group was divided into two subgroups according to the material of construction; Subgroup S: restored using zirconia-reinforced glass-ceramic and Subgroup E: restored using hybrid ceramic. The finished onlay restorations were luted to prepared teeth using self-adhesive resin cement. Specimens were exposed to thermocycling for 5000 cycles. Fracture resistance was assessed using a Universal testing machine. Failure mode was evaluated using a stereomicroscope. Two-way ANOVA was used to assess the effect of different tested variables and their interaction. Intergroup comparison was done using one-way ANOVA followed by Tukey’s post hoc test. The significance level was set at p≤0.05 within all tests. Results: Two-Way ANOVA showed that ceramic material had no significant effect on the fracture resistance of restored teeth. While the preparation design had a statistically significant effect. The interactions between the independent variables, ceramic materials, and preparation designs had a significant effect on the fracture resistance of teeth. Conclusion: Both preparation designs and materials showed clinically acceptable fracture resistance of onlay restorations. All subgroups showed high fracture resistance and favorable failure modes except VITA SUPRINITY with anatomical reduction of the functional cusp.
- 1 July 2021
- Published by Egyptian Knowledge Bank in Egyptian Dental Journal
- Vol. 67  (3) , 2509-2517
The Effect of Ceramic Material and Preparation Design on the Fracture Resistance of Onlay Restorations
Objectives: Evaluating the fracture resistance and failure mode of human maxillary premolars restored with two ceramic onlay materials prepared with two preparation designs. Materials and methods: A total of 40 extracted, human maxillary premolars were selected and divided into two groups according to preparation design; Group A: MOD cavity with anatomical reduction of functional cusp and Group F: MOD cavity with flat reduction of the functional cusp. Each group was divided into two subgroups according to the material of construction; Subgroup S: restored using zirconia-reinforced glass-ceramic and Subgroup E: restored using hybrid ceramic. The finished onlay restorations were luted to prepared teeth using self-adhesive resin cement. Specimens were exposed to thermocycling for 5000 cycles. Fracture resistance was assessed using a Universal testing machine. Failure mode was evaluated using a stereomicroscope. Two-way ANOVA was used to assess the effect of different tested variables and their interaction. Intergroup comparison was done using one-way ANOVA followed by Tukey’s post hoc test. The significance level was set at p≤0.05 within all tests. Results: Two-Way ANOVA showed that ceramic material had no significant effect on the fracture resistance of restored teeth. While the preparation design had a statistically significant effect. The interactions between the independent variables, ceramic materials, and preparation designs had a significant effect on the fracture resistance of teeth. Conclusion: Both preparation designs and materials showed clinically acceptable fracture resistance of onlay restorations. All subgroups showed high fracture resistance and favorable failure modes except VITA SUPRINITY with anatomical reduction of the functional cusp.
- Open Access
- 1 July 2021
- Published by Editora Cubo in Brazilian Dental Science
- Vol. 24  (3)
Fracture Resistance of Anterior CAD/CAM Nanoceramic Resin Endocrowns with Different Preparation Designs
Objective: The aim of the study was to evaluate the effect of extension of endocrown in pulp space and the effect of ferrule on the fracture resistance of anterior endocrowns made of nano-ceramic resin blocks. Material and Methods: Twenty-eight freshly extracted human upper central incisor teeth were prepared to receive CAD/CAM nanoceramic resin endocrowns with four different designs. The specimens were divided into two groups (n = 14) according to the extension of the endocrown inside root canal (A:short and B:long), then each group was further subdivided into another two subgroups (n = 7) according to the presence or absence of ferrule effect (1:ferrule and 2: no ferrule). Endocrowns were then fabricated using CEREC in lab and nanoceramic resin blocks (DENTSPLY Sirona, Germany) and LAVA ultimate (3M ESPE, Germany) blocks size 14L. Results: Two-way ANOVA showed that the ferrule (P > 0.0001) had statistically significant effect on the fracture resistance. However, the extension of the endocrown into the canal had no statistical significant effect on the fracture resistance (P = 0.837). The interactions between the independent variables (extension into the canal and ferrule) had statistically significant effect on the fracture resistance(P = 0.029). Load to fracture for group 1A was 439.53 N, 1B was 306.46 N, 2A was 516.29 N and 2B was 242.04 N. Conclusions: Fracture resistance was not improved by the long or short extensions of the endocrowns in the pulp space, however, the ferrule effect shows significant improvement of the fracture resistance of the nanoceramic resin endocrowns. Keywords Anterior endocrowns; Endocrown extensions; Fracture resistance; Nanoceramic resin blocks.
- 1 July 2021
- Published by Editora Cubo in Brazilian Dental Science
- Vol. 24  (3)
Open AccessFracture Resistance of Anterior CAD/CAM Nanoceramic Resin Endocrowns with Different Preparation Designs
Objective: The aim of the study was to evaluate the effect of extension of endocrown in pulp space and the effect of ferrule on the fracture resistance of anterior endocrowns made of nano-ceramic resin blocks. Material and Methods: Twenty-eight freshly extracted human upper central incisor teeth were prepared to receive CAD/CAM nanoceramic resin endocrowns with four different designs. The specimens were divided into two groups (n = 14) according to the extension of the endocrown inside root canal (A:short and B:long), then each group was further subdivided into another two subgroups (n = 7) according to the presence or absence of ferrule effect (1:ferrule and 2: no ferrule). Endocrowns were then fabricated using CEREC in lab and nanoceramic resin blocks (DENTSPLY Sirona, Germany) and LAVA ultimate (3M ESPE, Germany) blocks size 14L. Results: Two-way ANOVA showed that the ferrule (P > 0.0001) had statistically significant effect on the fracture resistance. However, the extension of the endocrown into the canal had no statistical significant effect on the fracture resistance (P = 0.837). The interactions between the independent variables (extension into the canal and ferrule) had statistically significant effect on the fracture resistance(P = 0.029). Load to fracture for group 1A was 439.53 N, 1B was 306.46 N, 2A was 516.29 N and 2B was 242.04 N. Conclusions: Fracture resistance was not improved by the long or short extensions of the endocrowns in the pulp space, however, the ferrule effect shows significant improvement of the fracture resistance of the nanoceramic resin endocrowns. Keywords Anterior endocrowns; Endocrown extensions; Fracture resistance; Nanoceramic resin blocks.