Jan Christoph Thiele
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jan Christoph Thiele has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
- Philipp Kukura
University of Oxford
11 shared publications - Jörg Enderlein
Third Institute of Physics – Biophysics Georg August University Friedrich‐Hund‐Platz 1 37077 Göttingen Germany
8 shared publications - Justin L. P. Benesch
Department of Chemistry, Physical and Theoretical Chemistry Laboratory, University of Oxford, Oxford, UK
6 shared publications - Oleksii Nevskyi
Third Institute of Physics—Biophysics, Georg August University, Göttingen, Germany
6 shared publications - Roman Tsukanov
III. Institute of Physics - Biophysics, University of Göttingen, Göttingen, Germany
6 shared publications - Dan Loewenthal
University of Oxford
4 shared publications
Latest Publications
- Open Access
- 26 October 2026
- Published by Springer Nature in Nature Methods
- Vol. 23 (11) , 2151-2154
Continuous mass photometry by single-molecule trapping
The dynamic choreography of biomolecular interactions underpins the processes of life, but its direct observation remains challenging. Here we introduce continuous mass photometry, enabling hour-long, mass-resolved observation of individual biomolecules tethered to supported lipid bilayers, their complexes and interactions, with up to sub-kilodalton mass precision and millisecond temporal resolution. Our approach represents a quantitative time-resolved single-molecule measurement modality for studying complex biomolecular mechanisms in action.
- 26 October 2026
- Published by Springer Nature in Nature Methods
- Vol. 23 (11) , 2151-2154
Open AccessContinuous mass photometry by single-molecule trapping
The dynamic choreography of biomolecular interactions underpins the processes of life, but its direct observation remains challenging. Here we introduce continuous mass photometry, enabling hour-long, mass-resolved observation of individual biomolecules tethered to supported lipid bilayers, their complexes and interactions, with up to sub-kilodalton mass precision and millisecond temporal resolution. Our approach represents a quantitative time-resolved single-molecule measurement modality for studying complex biomolecular mechanisms in action.
- Open Access
Modular DNA nanosensors enable state-aware multiplexed single-molecule mass photometry in complex media
Proteins exist in diverse biochemical states, including oligomers, complexes, heterogeneous proteoforms and shed fragments that encode functional and regulatory information. Yet, these molecular states remain difficult to resolve with existing analytical techniques, which typically require labelling, immobilisation or amplification and collapse this information into a single readout. Here, we introduce a modular platform that integrates programmable DNA nanostructures with single-molecule mass photometry for rapid, label-free and multiplexed protein analysis in native and complex media, without washing, enrichment or immobilisation, making native biochemical states observable directly in serum and plasma. DNA nanostructures act as nanosensors whose mass and mobility on supported lipid bilayers provide orthogonal identifiers for target identity and biochemical state, thereby decoupling recognition from readout. We define the analytical specificity and response window, demonstrate quantitative affinity determination, and resolve oligomeric and proteoform differences under native conditions. The nanosensors are rapidly reprogrammable to new targets, support multiplexed detection with internal controls for non-specific interactions, and enable selective resetting via strand displacement. Together, these capabilities establish nanoscale programmability as a route to state-resolved single-molecule protein profiling adaptable to both diagnostic and mechanistic applications.
Open AccessModular DNA nanosensors enable state-aware multiplexed single-molecule mass photometry in complex media
Proteins exist in diverse biochemical states, including oligomers, complexes, heterogeneous proteoforms and shed fragments that encode functional and regulatory information. Yet, these molecular states remain difficult to resolve with existing analytical techniques, which typically require labelling, immobilisation or amplification and collapse this information into a single readout. Here, we introduce a modular platform that integrates programmable DNA nanostructures with single-molecule mass photometry for rapid, label-free and multiplexed protein analysis in native and complex media, without washing, enrichment or immobilisation, making native biochemical states observable directly in serum and plasma. DNA nanostructures act as nanosensors whose mass and mobility on supported lipid bilayers provide orthogonal identifiers for target identity and biochemical state, thereby decoupling recognition from readout. We define the analytical specificity and response window, demonstrate quantitative affinity determination, and resolve oligomeric and proteoform differences under native conditions. The nanosensors are rapidly reprogrammable to new targets, support multiplexed detection with internal controls for non-specific interactions, and enable selective resetting via strand displacement. Together, these capabilities establish nanoscale programmability as a route to state-resolved single-molecule protein profiling adaptable to both diagnostic and mechanistic applications.
- Open Access
Mass-specific single molecule pull-down from complex mixtures with bilayer-assisted mass photometry
Determining the identity, quantity and interactions of proteins is fundamental to studies of biomolecular function and (dis)regulation in disease. Here, we combine mass photometry with supported lipid bilayers (SLBs) to specifically recruit proteins of interest from complex mixtures such as cell lysate and demonstrate sensitive detection and mass measurement of single biomolecules and their complexes without prior purification. Extending to heterologously expressed proteins, we provide rapid information on oligomerisation and concentration in lysate. Introduction of polyethylene glycol in the SLBs passivates against a variety of cell lysates and serum, allows specific recruitment of proteins from complex mixtures and mass-specific detection and affinity measurement at sub-nM concentrations. Our approach preserves the mass resolution and accuracy of mass photometry, thereby enabling visualisation and quantification of oligomeric states, interactions and complexes directly from cell lysates.
Open AccessMass-specific single molecule pull-down from complex mixtures with bilayer-assisted mass photometry
Determining the identity, quantity and interactions of proteins is fundamental to studies of biomolecular function and (dis)regulation in disease. Here, we combine mass photometry with supported lipid bilayers (SLBs) to specifically recruit proteins of interest from complex mixtures such as cell lysate and demonstrate sensitive detection and mass measurement of single biomolecules and their complexes without prior purification. Extending to heterologously expressed proteins, we provide rapid information on oligomerisation and concentration in lysate. Introduction of polyethylene glycol in the SLBs passivates against a variety of cell lysates and serum, allows specific recruitment of proteins from complex mixtures and mass-specific detection and affinity measurement at sub-nM concentrations. Our approach preserves the mass resolution and accuracy of mass photometry, thereby enabling visualisation and quantification of oligomeric states, interactions and complexes directly from cell lysates.
- Open Access
Continuous mass photometry by single molecule trapping
The dynamic choreography of biomolecular interactions underpins the processes of life, but its direct observation remains challenging. Here, we introduce confined diffusion mass photometry, enabling hour-long, mass-resolved observation of individual biomolecules, their complexes and interactions with up to sub-kDa mass precision and ms temporal resolution. Our approach represents a quantitative time-resolved single-molecule measurement modality for studying complex biomolecular mechanisms in action.
Open AccessContinuous mass photometry by single molecule trapping
The dynamic choreography of biomolecular interactions underpins the processes of life, but its direct observation remains challenging. Here, we introduce confined diffusion mass photometry, enabling hour-long, mass-resolved observation of individual biomolecules, their complexes and interactions with up to sub-kDa mass precision and ms temporal resolution. Our approach represents a quantitative time-resolved single-molecule measurement modality for studying complex biomolecular mechanisms in action.
- Open Access
- 19 January 2026
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 20 (4) , 3410-3422
Deep Learning-Based Event Classification of Mass Photometry Data for Optimal Mass Measurement at the Single-Molecule Level
Mass photometry (MP) is a powerful technique for studying biomolecular structures, interactions, and dynamics in solution. It detects and quantifies small reflectivity changes at a glass-water interface during protein (un)binding, with signals typically averaged over 100 ms. However, particle motion at the point of single-molecule measurement can compromise key metrics such as mass resolution, sensitivity, and concentration. We present a three-dimensional convolutional residual network trained via supervised learning to classify landing events based on their spatiotemporal dynamics. By analyzing 3D event thumbnails, our method isolates optimal single-molecule measurements, eliminating cumulative histogram artifacts and improving resolving power by up to a factor of 2. Validated across diverse experimental data sets, including resolved and partially resolved samples, and varying masses, concentrations, and integration times, our approach delivers robust performance under (sub)optimal conditions. Our approach also provides measurement-level data-driven feedback, facilitating high quality MP measurements in challenging scenarios.
- 19 January 2026
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 20 (4) , 3410-3422
Open AccessDeep Learning-Based Event Classification of Mass Photometry Data for Optimal Mass Measurement at the Single-Molecule Level
Mass photometry (MP) is a powerful technique for studying biomolecular structures, interactions, and dynamics in solution. It detects and quantifies small reflectivity changes at a glass-water interface during protein (un)binding, with signals typically averaged over 100 ms. However, particle motion at the point of single-molecule measurement can compromise key metrics such as mass resolution, sensitivity, and concentration. We present a three-dimensional convolutional residual network trained via supervised learning to classify landing events based on their spatiotemporal dynamics. By analyzing 3D event thumbnails, our method isolates optimal single-molecule measurements, eliminating cumulative histogram artifacts and improving resolving power by up to a factor of 2. Validated across diverse experimental data sets, including resolved and partially resolved samples, and varying masses, concentrations, and integration times, our approach delivers robust performance under (sub)optimal conditions. Our approach also provides measurement-level data-driven feedback, facilitating high quality MP measurements in challenging scenarios.
- 13 October 2025
- Published by Springer Nature in Nature Protocols
- Vol. 21 (7) , 2894-2918
Best practice mass photometry: a guide to optimal single-molecule mass measurement
Mass photometry (MP) has emerged as a powerful approach to study quaternary biomolecular structure, dynamics and interactions. The capabilities of the method ultimately hinge on the ability to accurately measure the tiny optical contrast generated by individual molecules at a glass–water interface, which enables mass-resolved quantification of biomolecular mixtures. Ideally, this capability is limited only by photon shot noise, but in practice depends on additional parameters and details of the assay. Here, we focus on the key factors affecting MP performance and present simple steps that can be taken to achieve optimal MP measurements in terms of mass resolution, quantitative detection limit, reproducibility and analyte concentration range without compromising the speed and simplicity of the technique. Each sample takes <10 min to analyse, with an additionial 2 h if amination of the glass surface is desired.
- 13 October 2025
- Published by Springer Nature in Nature Protocols
- Vol. 21 (7) , 2894-2918
Best practice mass photometry: a guide to optimal single-molecule mass measurement
Mass photometry (MP) has emerged as a powerful approach to study quaternary biomolecular structure, dynamics and interactions. The capabilities of the method ultimately hinge on the ability to accurately measure the tiny optical contrast generated by individual molecules at a glass–water interface, which enables mass-resolved quantification of biomolecular mixtures. Ideally, this capability is limited only by photon shot noise, but in practice depends on additional parameters and details of the assay. Here, we focus on the key factors affecting MP performance and present simple steps that can be taken to achieve optimal MP measurements in terms of mass resolution, quantitative detection limit, reproducibility and analyte concentration range without compromising the speed and simplicity of the technique. Each sample takes <10 min to analyse, with an additionial 2 h if amination of the glass surface is desired.
- Open Access
Deep learning-based event classification of mass photometry data for optimal mass measurement at the single-molecule level
Mass photometry (MP) is a powerful technique for studying biomolecular structure, interactions, and dynamics in solution. It detects and quantifies small reflectivity changes at a glass-water interface during protein (un)binding, with signals typically averaged over 100 milliseconds. However, particle motion at the point of single-molecule measurement can compromise key metrics such as mass resolution, sensitivity, and concentration. We present a three-dimensional convolutional residual network trained via supervised learning to classify landing events based on their spatiotemporal dynamics. By analysing 3D event thumbnails, our method isolates optimal single-molecule measurements, eliminating cumulative histogram artifacts and improving resolving power by up to a factor of 2. Validated across diverse experimental datasets—including resolved and partially resolved samples, and varying masses, concentrations, and integration times—our approach delivers robust performance under (sub)optimal conditions. Our approach provides measurement-level data-driven feedback, facilitating high quality MP measurements in challenging scenarios.
Open AccessDeep learning-based event classification of mass photometry data for optimal mass measurement at the single-molecule level
Mass photometry (MP) is a powerful technique for studying biomolecular structure, interactions, and dynamics in solution. It detects and quantifies small reflectivity changes at a glass-water interface during protein (un)binding, with signals typically averaged over 100 milliseconds. However, particle motion at the point of single-molecule measurement can compromise key metrics such as mass resolution, sensitivity, and concentration. We present a three-dimensional convolutional residual network trained via supervised learning to classify landing events based on their spatiotemporal dynamics. By analysing 3D event thumbnails, our method isolates optimal single-molecule measurements, eliminating cumulative histogram artifacts and improving resolving power by up to a factor of 2. Validated across diverse experimental datasets—including resolved and partially resolved samples, and varying masses, concentrations, and integration times—our approach delivers robust performance under (sub)optimal conditions. Our approach provides measurement-level data-driven feedback, facilitating high quality MP measurements in challenging scenarios.
- Open Access
- 9 April 2025
- Published by American Chemical Society (ACS) in ACS Photonics
- Vol. 12 (5) , 2647-2655
Enhanced Interferometric Imaging by Rotating Coherent Scattering Microscopy
Label-free microscopy on the nanoscale requires high-sensitivity imaging. The challenge of visualizing very small objects, such as nanoparticles, arises from their weak interaction with light. As a result, a combination of high signal-to-noise ratio imaging and background rejection is needed for detection and quantification. Here, we combine concepts from interferometric scattering (iSCAT) microscopy and rotating coherent scattering (ROCS) microscopy to optimize both background rejection and high-sensitivity imaging. Total internal reflection produces a background light intensity more than 2 orders of magnitude stronger than in iSCAT. Despite this, we successfully image 20 nm gold nanoparticles using our combined approach while achieving a signal-to-noise ratio (SNR) comparable to iSCAT at incident power densities as low as 0.04 kW/cm2. We experimentally characterize the effect of different incident polarizations and achieve maximal optical contrast using s-polarized illumination. We further demonstrate that ROCS-based illumination at or near total internal reflection yields an approximate 4-fold contrast enhancement and 2-fold background suppression, producing substantially improved SNR compared to iSCAT for the same illumination power entering the microscope objective and integration time. We attribute this to the increased spatial resolution, enhanced incident power density, and rotational averaging of surface-generated speckle. These advantages highlight the potential to achieve and exceed the sensitivity levels attained by related interferometric imaging techniques.
- 9 April 2025
- Published by American Chemical Society (ACS) in ACS Photonics
- Vol. 12 (5) , 2647-2655
Open AccessEnhanced Interferometric Imaging by Rotating Coherent Scattering Microscopy
Label-free microscopy on the nanoscale requires high-sensitivity imaging. The challenge of visualizing very small objects, such as nanoparticles, arises from their weak interaction with light. As a result, a combination of high signal-to-noise ratio imaging and background rejection is needed for detection and quantification. Here, we combine concepts from interferometric scattering (iSCAT) microscopy and rotating coherent scattering (ROCS) microscopy to optimize both background rejection and high-sensitivity imaging. Total internal reflection produces a background light intensity more than 2 orders of magnitude stronger than in iSCAT. Despite this, we successfully image 20 nm gold nanoparticles using our combined approach while achieving a signal-to-noise ratio (SNR) comparable to iSCAT at incident power densities as low as 0.04 kW/cm2. We experimentally characterize the effect of different incident polarizations and achieve maximal optical contrast using s-polarized illumination. We further demonstrate that ROCS-based illumination at or near total internal reflection yields an approximate 4-fold contrast enhancement and 2-fold background suppression, producing substantially improved SNR compared to iSCAT for the same illumination power entering the microscope objective and integration time. We attribute this to the increased spatial resolution, enhanced incident power density, and rotational averaging of surface-generated speckle. These advantages highlight the potential to achieve and exceed the sensitivity levels attained by related interferometric imaging techniques.
- Open Access
Best practice mass photometry: A guide to optimal single molecule mass measurement
Mass photometry (MP) has emerged as a powerful approach to study biomolecular structure, dynamics and interactions. The capabilities of the method ultimately hinge on the ability to accurately measure the tiny optical contrast generated by individual molecules landing at a glass-water interface, which enables mass-resolved quantification of biomolecular mixtures. Ideally, this capability is only limited by shot noise inherent to photon detection, but in practice depends on additional parameters and details of the assay. Here, we focus on the key parameters affecting MP performance, and present simple steps that can be taken to achieve optimal MP performance in terms of mass resolution, quantitative detection limit and analyte concentration range without compromising the ease and simplicity of the technique.
Open AccessBest practice mass photometry: A guide to optimal single molecule mass measurement
Mass photometry (MP) has emerged as a powerful approach to study biomolecular structure, dynamics and interactions. The capabilities of the method ultimately hinge on the ability to accurately measure the tiny optical contrast generated by individual molecules landing at a glass-water interface, which enables mass-resolved quantification of biomolecular mixtures. Ideally, this capability is only limited by shot noise inherent to photon detection, but in practice depends on additional parameters and details of the assay. Here, we focus on the key parameters affecting MP performance, and present simple steps that can be taken to achieve optimal MP performance in terms of mass resolution, quantitative detection limit and analyte concentration range without compromising the ease and simplicity of the technique.
- 2 August 2024
- Published by Springer Nature in Nature Photonics
- Vol. 18 (10) , 1059-1066
Doubling the resolution of fluorescence-lifetime single-molecule localization microscopy with image scanning microscopy
- 2 August 2024
- Published by Springer Nature in Nature Photonics
- Vol. 18 (10) , 1059-1066
Doubling the resolution of fluorescence-lifetime single-molecule localization microscopy with image scanning microscopy