Robert E. Morales
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Robert E. Morales has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- David Jeffrey Eisenman
Department of Otorhinolaryngology‐Head and Neck Surgery University of Maryland School of Medicine Baltimore Maryland USA
1 shared publication - David M. Yousem
Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
1 shared publication - Dheeraj Gandhi
Division of Neurointerventional Surgery, Department of Neurosurgery, University of Maryland Medical Center, Baltimore (H.C., D.G.).
1 shared publication - Elham Beheshtian
Department of Radiology and Biomedical Imaging, University of California–San Francisco, San Francisco, CA
1 shared publication - Elizabeth A. Krupinski
Department of Radiology & Imaging Sciences Emory University, 1364 Clifton Rd NE, Atlanta, GA, 30322, USA.
1 shared publication - Henry Zhan
Emory University, Atlanta, GA
1 shared publication
Latest Publications
- 16 March 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11316, 1131605-4
Where’s WALDO: a potential tool for training radiology residents?
We investigated the effects of using games to identify hidden abnormalities to enhance visual diagnostic skills in radiology residents. Radiology residents viewed 50 chest images while their eye position was recorded. They were then given a Where’s WALDO book to study over 3 weeks. They then reviewed the 50 chest images again. Performance in detecting abnormalities and visual search parameters were analyzed. There was no significant difference as a function of Waldo vs control for pre vs post testing. With respect to the eye-tracking data, the first measure considered was total viewing time. Overall there was a significant difference as a function of Waldo vs control group (z = 2.332, p = 0.0197) and pre vs post (F = 43.48, p < 0.0001) with those in the Waldo group experiencing a larger drop in viewing time from pre (mean = 20.65, sd = 15.29 Waldo; mean = 12.43, sd = 6.91 control) to post (mean = 14.62, sd = 10.32 Waldo; mean = 10.86, sd = 6.11 control). Fixation durations were significantly shorter (F = 16.51, p < 0.0001) pre (mean = 332.31, sd = 232.47 Waldo; mean = 378.32, sd = 234.88 control) than post (mean = 328.36, sd = 210.41 Waldo; mean = 359.45, sd = 228.17 control) and for control vs Waldo (F = 188.56, p < 0.0001). Practicing Where’s WALDO or similar nonradiology search task images may facilitate the acquisition of radiology image interpretation skills.
- 16 March 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11316, 1131605-4
Where’s WALDO: a potential tool for training radiology residents?
We investigated the effects of using games to identify hidden abnormalities to enhance visual diagnostic skills in radiology residents. Radiology residents viewed 50 chest images while their eye position was recorded. They were then given a Where’s WALDO book to study over 3 weeks. They then reviewed the 50 chest images again. Performance in detecting abnormalities and visual search parameters were analyzed. There was no significant difference as a function of Waldo vs control for pre vs post testing. With respect to the eye-tracking data, the first measure considered was total viewing time. Overall there was a significant difference as a function of Waldo vs control group (z = 2.332, p = 0.0197) and pre vs post (F = 43.48, p < 0.0001) with those in the Waldo group experiencing a larger drop in viewing time from pre (mean = 20.65, sd = 15.29 Waldo; mean = 12.43, sd = 6.91 control) to post (mean = 14.62, sd = 10.32 Waldo; mean = 10.86, sd = 6.11 control). Fixation durations were significantly shorter (F = 16.51, p < 0.0001) pre (mean = 332.31, sd = 232.47 Waldo; mean = 378.32, sd = 234.88 control) than post (mean = 328.36, sd = 210.41 Waldo; mean = 359.45, sd = 228.17 control) and for control vs Waldo (F = 188.56, p < 0.0001). Practicing Where’s WALDO or similar nonradiology search task images may facilitate the acquisition of radiology image interpretation skills.
- Open Access
- 1 October 2015
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 37 (1) , 136-142
Postoperative Imaging Findings following Sigmoid Sinus Wall Reconstruction for Pulse Synchronous Tinnitus
BACKGROUND AND PURPOSE: Transmastoid sigmoid sinus wall reconstruction is a surgical technique increasingly used for the treatment of pulsatile tinnitus arising from sigmoid sinus wall anomalies. The imaging appearance of the temporal bone following this procedure has not been well-characterized. The purpose of this study was to evaluate the postoperative imaging appearance in a group of patients who underwent this procedure. MATERIALS AND METHODS: The medical records of 40 consecutive patients who underwent transmastoid sigmoid sinus wall reconstruction were reviewed. Thirteen of 40 patients underwent postoperative imaging. Nineteen CT and 7 MR imaging examinations were assessed for the characteristics of the materials used for reconstruction, the impact of these on the adjacent sigmoid sinus, and complications. RESULTS: Tinnitus resolved in 38 of 40 patients. Nine patients were imaged postoperatively for suspected complications, including dural sinus thrombosis, facial swelling, and wound drainage. Two patients underwent imaging for persistent tinnitus, and 2, for development of tinnitus on the side contralateral to the side of surgery. The materials used for reconstruction (NeuroAlloderm, HydroSet, bone pate) demonstrated characteristic imaging appearances and could be consistently identified. In 5 of 13 patients, there was extrinsic compression of the sigmoid sinus by graft material. Dural sinus thrombosis occurred in 2 patients. CONCLUSIONS: The imaging findings following sigmoid sinus wall repair are characteristic. Graft materials may result in extrinsic compression of the sigmoid sinus, and this finding may be confused with dural venous thrombosis. Awareness of the imaging characteristics of the graft materials used enables this differentiation.
- 1 October 2015
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 37 (1) , 136-142
Open AccessPostoperative Imaging Findings following Sigmoid Sinus Wall Reconstruction for Pulse Synchronous Tinnitus
BACKGROUND AND PURPOSE: Transmastoid sigmoid sinus wall reconstruction is a surgical technique increasingly used for the treatment of pulsatile tinnitus arising from sigmoid sinus wall anomalies. The imaging appearance of the temporal bone following this procedure has not been well-characterized. The purpose of this study was to evaluate the postoperative imaging appearance in a group of patients who underwent this procedure. MATERIALS AND METHODS: The medical records of 40 consecutive patients who underwent transmastoid sigmoid sinus wall reconstruction were reviewed. Thirteen of 40 patients underwent postoperative imaging. Nineteen CT and 7 MR imaging examinations were assessed for the characteristics of the materials used for reconstruction, the impact of these on the adjacent sigmoid sinus, and complications. RESULTS: Tinnitus resolved in 38 of 40 patients. Nine patients were imaged postoperatively for suspected complications, including dural sinus thrombosis, facial swelling, and wound drainage. Two patients underwent imaging for persistent tinnitus, and 2, for development of tinnitus on the side contralateral to the side of surgery. The materials used for reconstruction (NeuroAlloderm, HydroSet, bone pate) demonstrated characteristic imaging appearances and could be consistently identified. In 5 of 13 patients, there was extrinsic compression of the sigmoid sinus by graft material. Dural sinus thrombosis occurred in 2 patients. CONCLUSIONS: The imaging findings following sigmoid sinus wall repair are characteristic. Graft materials may result in extrinsic compression of the sigmoid sinus, and this finding may be confused with dural venous thrombosis. Awareness of the imaging characteristics of the graft materials used enables this differentiation.