Yeji Han
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yeji Han has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Dongchan Kim
College of Medicine, Gachon University, Incheon, Republic of Korea
2 shared publications - HyunWook Park
School of Electrical Engineering KAIST Daejeon
2 shared publications - Chang-Hyun Oh
Department of Electronics and Information Engineering, Korea University, Sejong 30019, Republic of Korea
1 shared publication Hyunseok Seo
Department of Electrical Engineering, Korea Advanced Institute of Science and Technology, Guseong-dong, Yuseong-gu, Daejeon, Republic of Korea
1 shared publicationJaejin Cho
Department of Electrical Engineering, Korea Advanced Institute of Science and Technology, Guseong-dong, Yuseong-gu, Daejeon, Republic of Korea
1 shared publication- Joonsung Choi
Department of Radiology, St. Vincent’s Hospital, School of Medicine, The Catholic University of Korea, Suwon, Korea
1 shared publication
Latest Publications
- 5 June 2017
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 79 (2) , 779-788
Non‐contrast‐enhanced peripheral MR angiography using velocity‐selective excitation
Purpose: To develop a new non‐contrast‐enhanced peripheral MR angiography that provides a high contrast angiogram without using electrocardiography triggering and saturation radiofrequency pulses.Methods: A velocity‐selective excitation technique is used in conjunction with the golden‐angle radial sampling scheme. The signal amplitude varies according to the velocity of the flow by the velocity‐selective excitation technique. Because the arterial blood velocity varies depending on the cardiac phase, the acquired data can be classified into systolic and diastolic phase based on the signal amplitude of the artery. Two images are then reconstructed from the systolic and diastolic phase data, respectively, and an image reflecting the differences between the two images is obtained to eliminate background and vein signals. The performance of the proposed method was compared with the quiescent‐interval single shot (QISS) in eight healthy subjects and an elderly subject.Results: The proposed method generated fewer residual venous and background signals than the QISS. Furthermore, the maximum intensity projection images, the relative contrast, and the apparent contrast‐to‐noise ratio results showed that the proposed method produced a better contrast than the QISS.Conclusions: The proposed non‐contrast‐enhanced peripheral MR angiography technique can provide a high contrast angiogram without the use of electrocardiography triggering and saturation radiofrequency pulses. Magn Reson Med 79:779–788, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
- 5 June 2017
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 79 (2) , 779-788
Non‐contrast‐enhanced peripheral MR angiography using velocity‐selective excitation
Purpose: To develop a new non‐contrast‐enhanced peripheral MR angiography that provides a high contrast angiogram without using electrocardiography triggering and saturation radiofrequency pulses.Methods: A velocity‐selective excitation technique is used in conjunction with the golden‐angle radial sampling scheme. The signal amplitude varies according to the velocity of the flow by the velocity‐selective excitation technique. Because the arterial blood velocity varies depending on the cardiac phase, the acquired data can be classified into systolic and diastolic phase based on the signal amplitude of the artery. Two images are then reconstructed from the systolic and diastolic phase data, respectively, and an image reflecting the differences between the two images is obtained to eliminate background and vein signals. The performance of the proposed method was compared with the quiescent‐interval single shot (QISS) in eight healthy subjects and an elderly subject.Results: The proposed method generated fewer residual venous and background signals than the QISS. Furthermore, the maximum intensity projection images, the relative contrast, and the apparent contrast‐to‐noise ratio results showed that the proposed method produced a better contrast than the QISS.Conclusions: The proposed non‐contrast‐enhanced peripheral MR angiography technique can provide a high contrast angiogram without the use of electrocardiography triggering and saturation radiofrequency pulses. Magn Reson Med 79:779–788, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
- 15 April 2013
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (9) , 2969-2988
An iterative reconstruction method of complex images using expectation maximization for radial parallel MRI
In MRI (magnetic resonance imaging), signal sampling along a radial k-space trajectory is preferred in certain applications due to its distinct advantages such as robustness to motion, and the radial sampling can be beneficial for reconstruction algorithms such as parallel MRI (pMRI) due to the incoherency. For radial MRI, the image is usually reconstructed from projection data using analytic methods such as filtered back-projection or Fourier reconstruction after gridding. However, the quality of the reconstructed image from these analytic methods can be degraded when the number of acquired projection views is insufficient. In this paper, we propose a novel reconstruction method based on the expectation maximization (EM) method, where the EM algorithm is remodeled for MRI so that complex images can be reconstructed. Then, to optimize the proposed method for radial pMRI, a reconstruction method that uses coil sensitivity information of multichannel RF coils is formulated. Experiment results from synthetic and in vivo data show that the proposed method introduces better reconstructed images than the analytic methods, even from highly subsampled data, and provides monotonic convergence properties compared to the conjugate gradient based reconstruction method.
- 15 April 2013
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (9) , 2969-2988
An iterative reconstruction method of complex images using expectation maximization for radial parallel MRI
In MRI (magnetic resonance imaging), signal sampling along a radial k-space trajectory is preferred in certain applications due to its distinct advantages such as robustness to motion, and the radial sampling can be beneficial for reconstruction algorithms such as parallel MRI (pMRI) due to the incoherency. For radial MRI, the image is usually reconstructed from projection data using analytic methods such as filtered back-projection or Fourier reconstruction after gridding. However, the quality of the reconstructed image from these analytic methods can be degraded when the number of acquired projection views is insufficient. In this paper, we propose a novel reconstruction method based on the expectation maximization (EM) method, where the EM algorithm is remodeled for MRI so that complex images can be reconstructed. Then, to optimize the proposed method for radial pMRI, a reconstruction method that uses coil sensitivity information of multichannel RF coils is formulated. Experiment results from synthetic and in vivo data show that the proposed method introduces better reconstructed images than the analytic methods, even from highly subsampled data, and provides monotonic convergence properties compared to the conjugate gradient based reconstruction method.