Silvia Guillén-Climent
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Silvia Guillén-Climent has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Fernando Jesús Mayordomo-Riera
Interlevel Clinical Management Unit of Physical Medicine and Rehabilitation, Reina Sofía University Hospital, Guadalquivir Health District
3 shared publicationsManuela Mejías-Ruiz
Interlevel Clinical Management Unit of Physical Medicine and Rehabilitation, Reina Sofía University Hospital, Guadalquivir Health District
3 shared publicationsPablo Casado-Adam
Interlevel Clinical Management Unit of Physical Medicine and Rehabilitation, Reina Sofía University Hospital, Guadalquivir Health District
3 shared publicationsAinara Garzo
Neurorehabilitation area, Health Division of TECNALIA, Basque Research and Technology Alliance (BRTA), San Sebastián, Spain
2 shared publicationsMaría Nieves Muñoz-Alcaraz
Maimonides Biomedical Research Institute of Cordoba (IMIBIC), Reina Sofia University Hospital, University of Cordoba, Cordoba, Spain
2 shared publicationsAitor Martín-Odriozola
Fesia Technology
1 shared publication
Latest Publications
- Open Access
- 11 September 2026
- Published by Frontiers Media SA in Frontiers in Rehabilitation Sciences
- Vol. 7, 1920617
Feasibility and safety of multi-field functional electrical stimulation for distal upper-limb rehabilitation after subacute stroke: a randomised controlled feasibility trial
Background: Functional electrical stimulation (FES) is recommended for upper-limb rehabilitation after stroke but remains underused in routine clinical practice. Multi-field FES may simplify clinical application and improve selective muscle activation, although evidence generated under real-world rehabilitation conditions remains limited. Objective: To assess the feasibility, usability, and safety of multi-field FES for distal upper-limb rehabilitation after subacute stroke and to generate preliminary effect estimates to inform a future definitive trial. Methods: We conducted a single-centre, parallel-group, randomised controlled feasibility trial with blinded outcome assessment. Sixteen adults with subacute stroke (≤6 months) and unilateral upper-limb impairment were randomised 1:1 to FES-assisted therapy or conventional rehabilitation ( n = 8 per group). Both groups received two 40-minute upper-limb therapy sessions per week for 6 weeks (12 sessions); the experimental group received treatment using the Fesia Grasp multi-field stimulation device. Primary outcomes were retention, adherence, usability, motivation, and safety. Secondary exploratory outcomes included the Fugl-Meyer Assessment for Upper Extremity, modified Medical Research Council scale, grip strength, and Box and Block Test, assessed at baseline and post-intervention by blinded evaluators. Results: Of 20 participants screened between April 2022 and August 2023, 16 were recruited and randomised (8 per group) and received 12 sessions of 40 minutes over 6 weeks. All participants completed the study, resulting in 100% retention and adherence (16/16; 95% CI 79.4–100% for both outcomes). In the FES group, usability and motivation scores were high, indicating good acceptability of the intervention. Two FES participants experienced minor, transient skin erythema after electrode application; no serious adverse events were observed. Exploratory analyses yielded point estimates that favoured the FES group for distal upper-limb motor outcomes; however, confidence intervals were wide and findings should not be interpreted as evidence of clinical efficacy. Conclusion: Multi-field FES for distal upper-limb rehabilitation after subacute stroke was feasible and well accepted in routine clinical practice, with no serious adverse events observed. These findings provide preliminary data to support the design of future adequately powered efficacy trials. Clinical Trial Registration: https://clinicaltrials.gov/study/NCT04992910 , identifier: NCT04992910.
- 11 September 2026
- Published by Frontiers Media SA in Frontiers in Rehabilitation Sciences
- Vol. 7, 1920617
Open AccessFeasibility and safety of multi-field functional electrical stimulation for distal upper-limb rehabilitation after subacute stroke: a randomised controlled feasibility trial
Background: Functional electrical stimulation (FES) is recommended for upper-limb rehabilitation after stroke but remains underused in routine clinical practice. Multi-field FES may simplify clinical application and improve selective muscle activation, although evidence generated under real-world rehabilitation conditions remains limited. Objective: To assess the feasibility, usability, and safety of multi-field FES for distal upper-limb rehabilitation after subacute stroke and to generate preliminary effect estimates to inform a future definitive trial. Methods: We conducted a single-centre, parallel-group, randomised controlled feasibility trial with blinded outcome assessment. Sixteen adults with subacute stroke (≤6 months) and unilateral upper-limb impairment were randomised 1:1 to FES-assisted therapy or conventional rehabilitation ( n = 8 per group). Both groups received two 40-minute upper-limb therapy sessions per week for 6 weeks (12 sessions); the experimental group received treatment using the Fesia Grasp multi-field stimulation device. Primary outcomes were retention, adherence, usability, motivation, and safety. Secondary exploratory outcomes included the Fugl-Meyer Assessment for Upper Extremity, modified Medical Research Council scale, grip strength, and Box and Block Test, assessed at baseline and post-intervention by blinded evaluators. Results: Of 20 participants screened between April 2022 and August 2023, 16 were recruited and randomised (8 per group) and received 12 sessions of 40 minutes over 6 weeks. All participants completed the study, resulting in 100% retention and adherence (16/16; 95% CI 79.4–100% for both outcomes). In the FES group, usability and motivation scores were high, indicating good acceptability of the intervention. Two FES participants experienced minor, transient skin erythema after electrode application; no serious adverse events were observed. Exploratory analyses yielded point estimates that favoured the FES group for distal upper-limb motor outcomes; however, confidence intervals were wide and findings should not be interpreted as evidence of clinical efficacy. Conclusion: Multi-field FES for distal upper-limb rehabilitation after subacute stroke was feasible and well accepted in routine clinical practice, with no serious adverse events observed. These findings provide preliminary data to support the design of future adequately powered efficacy trials. Clinical Trial Registration: https://clinicaltrials.gov/study/NCT04992910 , identifier: NCT04992910.
- Open Access
- 1 January 2024
- Published by AVES YAYINCILIK A.Ş. in Acta Orthopaedica et Traumatologica Turcica
- Vol. 58 (1) , 77-79
Ultrasonography-guided percutaneous release of A3 pulley of the fifth finger to treat trigger finger: Description of the technique, with reference to a specific case
Trigger finger causes pain and a persistent functional limitation of the hand, which can lead to permanent blockage of the flexor tendon. Ultrasonography-guided percutaneous release has been widely reported as a successful technique for trigger finger involving the A1 pulley. This article describes for the first time the use of this technique in an unusual location, the A3 pulley of the fifth finger. A 71-year-old patient presented with a 3-month history of pain and blockage in the fifth finger of the right hand and was diagnosed with a grade III trigger finger, according to the Froimson scale. We performed an ultrasonography-guided percutaneous release technique on the A3 pulley to release the flexor tendon of the fifth finger. Ultrasonography-guided percutaneous polectomy to treat trigger finger in the A1 pulley is an effective alternative treatment to surgery and even has certain advantages over it. The anatomical similarity between the A1 and A3 pulleys was the key factor that supported the use of this technique in this clinical case. Based on past experience in similar cases, we conclude that ultrasonography-guided percutaneous polectomy of the A3 pulley of the fifth finger was a surgical technique which could lead to a satisfactory outcome in the treatment of this condition. Cite this article as: Montes-Comino M, De la Torre-López LE, Guillén-Climent S, Mayordomo-Riera FJ. Ultrasonography-guided percutaneous release of A3 pulley of the fifth finger to treat trigger finger: Description of the technique, with reference to a specific case. Acta Orthop Traumatol Turc., 2024;58(1):77-79.
- 1 January 2024
- Published by AVES YAYINCILIK A.Ş. in Acta Orthopaedica et Traumatologica Turcica
- Vol. 58 (1) , 77-79
Open AccessUltrasonography-guided percutaneous release of A3 pulley of the fifth finger to treat trigger finger: Description of the technique, with reference to a specific case
Trigger finger causes pain and a persistent functional limitation of the hand, which can lead to permanent blockage of the flexor tendon. Ultrasonography-guided percutaneous release has been widely reported as a successful technique for trigger finger involving the A1 pulley. This article describes for the first time the use of this technique in an unusual location, the A3 pulley of the fifth finger. A 71-year-old patient presented with a 3-month history of pain and blockage in the fifth finger of the right hand and was diagnosed with a grade III trigger finger, according to the Froimson scale. We performed an ultrasonography-guided percutaneous release technique on the A3 pulley to release the flexor tendon of the fifth finger. Ultrasonography-guided percutaneous polectomy to treat trigger finger in the A1 pulley is an effective alternative treatment to surgery and even has certain advantages over it. The anatomical similarity between the A1 and A3 pulleys was the key factor that supported the use of this technique in this clinical case. Based on past experience in similar cases, we conclude that ultrasonography-guided percutaneous polectomy of the A3 pulley of the fifth finger was a surgical technique which could lead to a satisfactory outcome in the treatment of this condition. Cite this article as: Montes-Comino M, De la Torre-López LE, Guillén-Climent S, Mayordomo-Riera FJ. Ultrasonography-guided percutaneous release of A3 pulley of the fifth finger to treat trigger finger: Description of the technique, with reference to a specific case. Acta Orthop Traumatol Turc., 2024;58(1):77-79.
- Open Access
- 23 February 2021
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 18 (1) , 1-16
A usability study in patients with stroke using MERLIN, a robotic system based on serious games for upper limb rehabilitation in the home setting
Background: Neuroscience and neurotechnology are transforming stroke rehabilitation. Robotic devices, in addition to telerehabilitation, are increasingly being used to train the upper limbs after stroke, and their use at home allows us to extend institutional rehabilitation by increasing and prolonging therapy. The aim of this study is to assess the usability of the MERLIN robotic system based on serious games for upper limb rehabilitation in people with stroke in the home environment. Methods: 9 participants with a stroke in three different stages of recovery (subacute, short-term chronic and long-term chronic) with impaired arm/hand function, were recruited to use the MERLIN system for 3 weeks: 1 week training at the Maimonides Biomedical Research Institute of Cordoba (IMIBIC), and 2 weeks at the patients’ homes. To evaluate usability, the System Usability Scale (SUS), Adapted Intrinsic Motivation Inventory (IMI), Quebec User Evaluation of Satisfaction with assistive Technology (QUEST), and the ArmAssist Usability Assessment Questionnaire were used in the post-intervention. Clinical outcomes for upper limb motor function were assessed pre- and post-intervention. Results: 9 patients participated in and completed the study. The usability assessment reported a high level of satisfaction: mean SUS score 71.94 % (SD = 16.38), mean QUEST scale 3.81 (SD = 0.38), and mean Adapted IMI score 6.12 (SD = 1.36). The results of the ArmAssist Questionnaire showed an average of 6 out of 7, which indicates that MERLIN is extremely intuitive, easy to learn and easy to use. Regarding clinical assessment, the Fugl-Meyer scores showed moderate improvements from pre- to post-intervention in the total score of motor function (p = 0.002). There were no significant changes in the Modified Ashworth scale outcomes (p = 0.169). Conclusions: This usability study indicates that home-based rehabilitation for upper limbs with the MERLIN system is safe, useful, feasible and motivating. Telerehabilitation constitutes a major step forward in the use of intensive rehabilitation at home. Trial registration ClinicalTrials.gov, NCT04405609. Registered 06 January 2020—Retrospectively registered, https://clinicaltrials.gov/ct2/show/NCT04405609
- 23 February 2021
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 18 (1) , 1-16
Open AccessA usability study in patients with stroke using MERLIN, a robotic system based on serious games for upper limb rehabilitation in the home setting
Background: Neuroscience and neurotechnology are transforming stroke rehabilitation. Robotic devices, in addition to telerehabilitation, are increasingly being used to train the upper limbs after stroke, and their use at home allows us to extend institutional rehabilitation by increasing and prolonging therapy. The aim of this study is to assess the usability of the MERLIN robotic system based on serious games for upper limb rehabilitation in people with stroke in the home environment. Methods: 9 participants with a stroke in three different stages of recovery (subacute, short-term chronic and long-term chronic) with impaired arm/hand function, were recruited to use the MERLIN system for 3 weeks: 1 week training at the Maimonides Biomedical Research Institute of Cordoba (IMIBIC), and 2 weeks at the patients’ homes. To evaluate usability, the System Usability Scale (SUS), Adapted Intrinsic Motivation Inventory (IMI), Quebec User Evaluation of Satisfaction with assistive Technology (QUEST), and the ArmAssist Usability Assessment Questionnaire were used in the post-intervention. Clinical outcomes for upper limb motor function were assessed pre- and post-intervention. Results: 9 patients participated in and completed the study. The usability assessment reported a high level of satisfaction: mean SUS score 71.94 % (SD = 16.38), mean QUEST scale 3.81 (SD = 0.38), and mean Adapted IMI score 6.12 (SD = 1.36). The results of the ArmAssist Questionnaire showed an average of 6 out of 7, which indicates that MERLIN is extremely intuitive, easy to learn and easy to use. Regarding clinical assessment, the Fugl-Meyer scores showed moderate improvements from pre- to post-intervention in the total score of motor function (p = 0.002). There were no significant changes in the Modified Ashworth scale outcomes (p = 0.169). Conclusions: This usability study indicates that home-based rehabilitation for upper limbs with the MERLIN system is safe, useful, feasible and motivating. Telerehabilitation constitutes a major step forward in the use of intensive rehabilitation at home. Trial registration ClinicalTrials.gov, NCT04405609. Registered 06 January 2020—Retrospectively registered, https://clinicaltrials.gov/ct2/show/NCT04405609
- Open Access
- 2 February 2021
- Published by Springer Nature in Research Square
A usability study in patients with stroke using MERLIN, a robotic system based on serious games for upper limb rehabilitation in the home setting.
Background: Neuroscience and neurotechnology are transforming stroke rehabilitation. Robotic devices, in addition to telerehabilitation, are increasingly being used to train the upper limbs after stroke, and their use at home allows us to extend institutional rehabilitation by increasing and prolonging therapy. The aim of this study is to assess the usability of the MERLIN robotic system based on serious games for upper limb rehabilitation in people with stroke in the home environment.Methods: 9 participants with a stroke in three different stages of recovery (subacute, short-term chronic and long-term chronic) with impaired arm/hand function, were recruited to use the MERLIN system for 3 weeks: one week training at the Maimonides Biomedical Research Institute of Cordoba (IMIBIC), and 2 weeks at the patients’ homes. To evaluate usability, the System Usability Scale (SUS), Adapted Intrinsic Motivation Inventory (IMI), Quebec User Evaluation of Satisfaction with assistive Technology (QUEST), and the ArmAssist Usability Assessment Questionnaire were used in the post-intervention. Clinical outcomes for upper limb motor function were assessed pre- and post-intervention.Results: 9 patients participated in and completed the study. The usability assessment reported a high level of satisfaction: mean SUS score 71.94 % (SD=16.38), mean QUEST scale 3.81 (SD=0.38), and mean Adapted IMI score 6.12 (SD=1.36). The results of the ArmAssist Questionnaire showed an average of 6 out of 7, which indicates that MERLIN is extremely intuitive, easy to learn and easy to use. Regarding clinical assessment, the Fugl-Meyer scores showed moderate improvements from pre- to post-intervention in the total score of motor function (p = 0.002). There were no significant changes in the Modified Ashworth scale outcomes (p = 0.169).Conclusions: This usability study indicates that home-based rehabilitation for upper limbs with the MERLIN system is safe, useful, feasible and motivating. Telerehabilitation constitutes a major step forward in the use of intensive rehabilitation at home.Trial registration: ClinicalTrials.gov, NCT04405609. Registered 06 January 2020 - Retrospectively registered, https://clinicaltrials.gov/ct2/show/NCT04405609
- 2 February 2021
- Published by Springer Nature in Research Square
Open AccessA usability study in patients with stroke using MERLIN, a robotic system based on serious games for upper limb rehabilitation in the home setting.
Background: Neuroscience and neurotechnology are transforming stroke rehabilitation. Robotic devices, in addition to telerehabilitation, are increasingly being used to train the upper limbs after stroke, and their use at home allows us to extend institutional rehabilitation by increasing and prolonging therapy. The aim of this study is to assess the usability of the MERLIN robotic system based on serious games for upper limb rehabilitation in people with stroke in the home environment.Methods: 9 participants with a stroke in three different stages of recovery (subacute, short-term chronic and long-term chronic) with impaired arm/hand function, were recruited to use the MERLIN system for 3 weeks: one week training at the Maimonides Biomedical Research Institute of Cordoba (IMIBIC), and 2 weeks at the patients’ homes. To evaluate usability, the System Usability Scale (SUS), Adapted Intrinsic Motivation Inventory (IMI), Quebec User Evaluation of Satisfaction with assistive Technology (QUEST), and the ArmAssist Usability Assessment Questionnaire were used in the post-intervention. Clinical outcomes for upper limb motor function were assessed pre- and post-intervention.Results: 9 patients participated in and completed the study. The usability assessment reported a high level of satisfaction: mean SUS score 71.94 % (SD=16.38), mean QUEST scale 3.81 (SD=0.38), and mean Adapted IMI score 6.12 (SD=1.36). The results of the ArmAssist Questionnaire showed an average of 6 out of 7, which indicates that MERLIN is extremely intuitive, easy to learn and easy to use. Regarding clinical assessment, the Fugl-Meyer scores showed moderate improvements from pre- to post-intervention in the total score of motor function (p = 0.002). There were no significant changes in the Modified Ashworth scale outcomes (p = 0.169).Conclusions: This usability study indicates that home-based rehabilitation for upper limbs with the MERLIN system is safe, useful, feasible and motivating. Telerehabilitation constitutes a major step forward in the use of intensive rehabilitation at home.Trial registration: ClinicalTrials.gov, NCT04405609. Registered 06 January 2020 - Retrospectively registered, https://clinicaltrials.gov/ct2/show/NCT04405609